• 제목/요약/키워드: B-mode ultrasound

검색결과 73건 처리시간 0.023초

Elastography for Breast Cancer Diagnosis: a Useful Tool for Small and BI-RADS 4 Lesions

  • Liu, Xue-Jing;Zhu, Ying;Liu, Pei-Fang;Xu, Yi-Lin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권24호
    • /
    • pp.10739-10743
    • /
    • 2015
  • The present study aimed at evaluating and comparing the diagnostic performance of B-mode ultrasound (US), elastography score (ES), and strain ratio (SR) for the differentiation of breast lesions. This retrospective study enrolled 431 lesions from 417 in-hospital patients. All patients were examined with both conventional ultrasound and elastography. Two experienced radiologists reviewed ultrasound and elasticity images. The histopathologic result obtained from ultrasound-guided core biopsy or operation excisions were used as the reference standard. Pathologic examination revealed 276 malignant lesions (64%) and 155 benign lesions (36%). A cut-off point of 4.15 (area under the curve, 0.891) allowed significant differentiation of malignant and benign lesions. ROC (receiver-operating characteristic) curves showed a higher value for combination of B-mode ultrasound and elastography for the diagnosis of breast lesions. Conventional ultrasound combined elastography showed high sensitivity, specificity, and accuracy for group II lesions (10mm${\leq}20mm$). Elastography combined with conventional ultrasound show high specificity and accuracy for differentiation of benign and malignant breast lesions. Elastography is particularly important for the diagnosis of BI-RADS 4 and small breast lesions.

Genetic Parameter Estimation of Carcass Traits of Duroc Predicted Using Ultrasound Scanning Modes

  • Salces, Agapita J.;Seo, Kang Seok;Cho, Kyu Ho;Kim, SiDong;Lee, Young Chang
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제19권10호
    • /
    • pp.1379-1383
    • /
    • 2006
  • A total of 6,804 records for Duroc breed were collected from three farms registered at the Korean Animal Improvement Association (KAIA) from 1998 to 2004 of which both records from two ultrasound modes (A and B) were analyzed to estimate the variance components of carcass traits. Three carcass traits backfat thickness (bf), loin eye muscle area (lma) and lean meat percentage (lmp) were measured. These traits were analyzed separately as bf1, lma1 and lmp1 for ultrasound mode A and bf2, lma2 and lmp2 for ultrasound mode B with multiple trait animal model by using MTDFREML (Boldman et al., 1993). All the traits revealed medium heritability values. Estimated heritabilities for bf1, bf2, lma1, lma2, lmp1 and lmp2 were 0.45, 0.39, 0.32, 0.25, 0.28 and 0.39, respectively. Estimated genetic correlations for traits bf1 and bf2, lma1 and lma2, lmp1 and lmp2 were positive but low. Specifically, genetic correlations between bf1 and bf2 was 0.30 while the estimates for lean traits between lma1 and lma2 and between lmp1 and lmp2 were 0.15 and 0.18, respectively. Conversely, high negative genetic correlations existed between bf1 and the lean traits lma2, lmp2. Likewise, the estimated genetic correlations between lma1 and lma2 and lmp1 and lmp2 were low.

저강도 초음파의 관절염 치료 적용성 평가 (An Evaluation of Low Intensity Ultrasonic Characteristics for Arthritis Healing)

  • 홍성민;한승무
    • 대한기계학회논문집A
    • /
    • 제29권6호
    • /
    • pp.787-794
    • /
    • 2005
  • Nowadays chronic degenerative diseases such as arthritis are increasing rapidly, even though acute infectious diseases are decreasing due to the advance of modern medicine. Although many of remedies are developed for arthritis healing, there is no precise medical prescription, and pathogenesis is not examined exactly. In this study, we confirmed gene expression of BMP 1A, BMP 2B, osteonectin and MGP which are genes related with bone formation in osteoblast by using ultrasonic stimulation. Through this study, we also evaluated the fact that ultrasound could be applied to arthritis healing by making activated osteoblast induce remodeling of cartilage. As a result of this research, BMP 2B and MGP have higher rates of expression in specific ultrasound mode. In conclusion, it is expected that ultrasound could be used efficiently for healing arthritis if we use ultrasounds according to symptoms of arthritis on reasonable terms.

초음파 진단모드에 따른 체표면 온도변화와 열효과에 관한 고찰 (A Study on Changes in Body Surface Temperature and Thermal Effect According to Ultrasound Mode)

  • 양성희;이진수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권2호
    • /
    • pp.213-218
    • /
    • 2017
  • 최근 고위험 임신군이 증가함에 따라 과거에 비해 음향파워 세기가 높은 도플러초음파 이용이 산전 진단에서 점차 증가하고 있으며, 여러 기관에서 가이드라인을 설정하여 과도한 노출을 자제하고 있다. 따라서 본 연구에서는 장시간 초음파검사 실시에 따른 검사모드 별 체표면의 온도변화를 알아보고 열효과에 영향을 받지 않는 노출시간을 고찰해 보고자 하였다. 시간경과에 따른 B mode, C mode, PD mode 별 초음파를 조사한 부위와 조사하지 않은 부위의 온도변화를 측정하여 차이를 비교하였으며 B mode는 초음파 조사 후 10분, 50분에서, C mode는 20분부터, PD mode는 30분부터 온도변화에 유의한 차이를 나타내었다(p<0.01). 측정시점에 따라 3개의 mode에서 모두 온도상승에 차이를 보였으며(p<0.000), PD mode가 가장 온도변화에 민감한 반응을 나타내었다. 또한 초음파 노출시간이 증가함에 따라 온도상승 시간이 짧아짐을 알 수 있었다. 따라서 배아나 태아를 관찰하기 위한 초음파검사 시 과도한 검사시간을 피하여 진단목적으로만 신속하게 사용할 것을 권고한다.

Value of Ultrasound Elastography in Assessment of Enlarged Cervical Lymph Nodes

  • Teng, Deng-Ke;Wang, Hui;Lin, Yuan-Qiang;Sui, Guo-Qing;Guo, Feng;Sun, Li-Na
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권5호
    • /
    • pp.2081-2085
    • /
    • 2012
  • Background: To investigate the value of ultrasound elastography (UE) in the differentiation between benign and malignant enlarged cervical lymph nodes (LNs). Methods: B-mode ultrasound, power Doppler imaging and UE were examined to determine LN characteristics. Two kinds of methods, 4 scores of elastographic classification and a strain ratio (SR) were used to evaluate the ultrasound elastograms. Results: The cutoff point of SR had high utility in differential diagnosis of benign and malignant of cervical lymph nodes, with good sensitivity, specificity and accuracy. Conclusion: UE is an important aid in differential diagnosis of benign and malignant cervical LNs.

Ultrasound and clinical findings in the metacarpophalangeal joint assessment of show jumping horses in training

  • Yamada, Ana Lucia M.;Pinheiro, Marcelo;Marsiglia, Marilia F.;Hagen, Stefano Carlo F.;Baccarin, Raquel Yvonne A.;da Silva, Luis Claudio L.C.
    • Journal of Veterinary Science
    • /
    • 제21권3호
    • /
    • pp.21.1-21.14
    • /
    • 2020
  • Background: Physical exercise is known to cause significant joint changes. Thus, monitoring joint behavior of athletic horses is essential in early disorders recognition, allowing the proper management. Objectives: The aims of this study were to determine the morphological patterns, physical examination characteristics and ultrasound findings of show jumping horses in training and to establish a score-based examination model for physical and ultrasound follow-ups of metacarpophalangeal joint changes in these animals. Methods: A total of 52 metacarpophalangeal joints from 26 horses who were initially in the taming stage were evaluated, and the horses' athletic progression was monitored. The horses were evaluated by a physical examination and by B-mode and Doppler-mode ultrasound examinations, starting at time zero (T0), which occurred concomitantly with the beginning of training, and every 3 months thereafter for a follow-up period of 18 months. Results: The standardized examination model revealed an increase in the maximum joint flexion angles and higher scores on the physical and ultrasound examinations after scoring was performed by predefined assessment tools, especially between 3 and 6 months of evaluation, which was immediately after the horses started more intense training. The lameness score and the ultrasound examination score were slightly higher at the end of the study. Conclusions: The observed results were probably caused by the implementation of a training regimen and joint adaptation to physical conditioning. The joints most likely undergo a pre-osteoarthritic period due to work overload, which can manifest in a consistent or adaptive manner, as observed during this study. Thus, continuous monitoring of young athlete horses by physical and ultrasound examinations that can be scored is essential.

트랜스듀서의 음장 특성을 고려한 초음파 스펙클 패턴의 발생과 해석 (Generation and Analysis of Ultrasound Speckle Patterns considering Acoustic Field Characteristics of Transducer)

  • 박희영;최종호;최종수
    • 전자공학회논문지B
    • /
    • 제28B권10호
    • /
    • pp.822-830
    • /
    • 1991
  • In this paper, we propose a new process for ultrasonic B-mode image considering the sound field effects of a concave circuit focused transducer, and aim to remove the speckle pattern which cause the blurring on boundary in ultrasonic B-mode image. We discuss in detail the conception of speckle pattern generation, and the frequency compounding method which is applied to the process for getting a speckle reduced B-mode image. Through the computer simulation, we define the meaning of speckle region, and show the results of reduced speckle pattern. It is discovered in the results that the frequency compounding method is very effective for boundary detection and that the application of the method is limited by various conditions.

  • PDF

탄성 영상법 개발을 위한 유연성 높은 초음파 시스템의 구현 (Development of Flexible Ultrasound System for Elastography)

  • 김동인;이수열;조민형
    • 대한의용생체공학회:의공학회지
    • /
    • 제33권1호
    • /
    • pp.32-38
    • /
    • 2012
  • Recently, several ultrasound imaging techniques for tissue characterization have been developed. Among them, ultrasound elastography is regarded as the most promising modality and has been rapidly developed. One of ultrasound elastography techniques is shear modulus imaging. Normal and cancerous tissues show big difference of shear moduli and they have good image contrast. However shear wave elastography requires more complicated hardware and more computations for image reconstruction algorithm. Therefore new efficient techniques are being developed. In this paper, we have developed a very flexible ultrasound system for elastography experiments. The developed system has capabilities to acquire ultrasound RF data of all channels and generate arbitrary ultrasound pulse sequences. It has a huge amount of memories for RF data acquisition and a simple and flexible pulse generator. We have verified the performance of the system showing conventional B-mode images and preliminary results of elastography. The developed system will be used to verify our own reconstruction algorithm and to develop more efficient elastography techniques.

초음파를 이용한 리도카인 수용성겔의 경피흡수 및 진통효과 (Transdermal Delivery and Analgesic Effects of Lidocaine Hydrogel by Phonophoresis)

  • 양재헌;김대근;송경숙;윤미영;안효초;김영일;김태열
    • Journal of Pharmaceutical Investigation
    • /
    • 제37권3호
    • /
    • pp.149-158
    • /
    • 2007
  • To investigate the permeability of lidocaine, percutaneous absorption studies were performed using excised hairless mouse skin and the penetration of lidocaine via the skin was determined. To increase the skin permeation of lidocine, the effects of $Labrasol^{(R)}$, $Labrafil^{(R)}$, $Labrafac^{(R)}$ and $Transcutol^{(R)}$ were investigated. The skin permeation of lidocaine was increased when $Labrasol^{(R)}$ and $Transcutol^{(R)}$ were used as permeation enhancer. To evaluate the influence of ultrasound, various factors such as application modes (continuous mode and pulsed mode), frequency (1.0 and 3.0 MHz) and intensity (1.0, 1.5 and 2.0 w/$cm^2$) were investigated with lidocaine hydrogel. The pronounced effect of ultrasound on the skin permeation of lidocaine was observed at all ultrasound energy levels. The influence of frequency having an effect on skin permeation rate was higher in the case of using 1 MHz, 2.0 w/$cm^2$ and continuous treatment. As the intensity of ultrasound increased, the permeation of lidocaine was accelerated. The in vivo anesthetic effects were evaluated by two aspects as mechanical threshold and electrical threshold. Six healthy volunteers consented to the randomized, double-blind, and cross-over designed study in each group. In each subject, 3 groups were adapted such as K group (ultrasound with gel base only), L group (lidocaine gel) and B group (ultrasound with lidocaine gel). In conclusion, lidocaine was potent anesthetic which could be block pain threshold effectively. And ultrasound could accelerate the skin penetration of lidocaine. The phonophoretic delivery system could be a good candidate for lidocaine as a local anaesthetic to improve the skin permeation and in vivo anaesthetic effect.

초음파를 이용한 한우의 조기임신진단에 관한 연구 (Studies on Early Pregnancy Diagnosis in Korean Native Cattle by Ultrasonography)

  • 전병준;윤기영;이은송;이우근;이병천;황우석
    • 한국수정란이식학회지
    • /
    • 제11권3호
    • /
    • pp.291-300
    • /
    • 1996
  • Real time B-mode ultrasound was used to detect the early conceptus in 187 Korean native cattles between days 10 and 60 after last insemination. The ultrasound diagnostic findings were systemically confirmed by palpation per rectum after the 60th day of last insemination. The embryonic vesicle and the embryo proper within the veside were first visible on mean day fl and 23, respectively. The heartbeat of the embryo proper could be detected on day 26, and the limb buds, placentomes, amnion, fetal movement, umbilical cord, optic area and split hooves were first visible on day 33, 34, 34, 44.5, 45, 32 and 48, respectively. The mean length of embryo proper was 3.8mm on day 23 which later increased to 56. 6rnrn on day 60. When ultrasound was used to detect the conceptus between days 20 and 30 after insemination and palpation per rectum after the 60th day of insemination, the accuracy rates of pregnancy detection by ultrasound scanning at days 20, 22, 24, 26, 28, 30 were 44.4, 69.2, 78.6, 87.5, 90.0, 93.3%. In summary, the early pregnancy diagnosis of Korean native cattle with ultrasound appears high accuracy rates. It is considered that ultrasound can be used in veterinary practice well.

  • PDF