• Title/Summary/Keyword: B-20 drops

Search Result 20, Processing Time 0.025 seconds

Attenuation of streptozotocin mediated oxidative stress, hyperglycemia and toxicity in rats by treatment with B-20 drpos - a homoeopathic preparation

  • Pillai, KK;Najmi, Abul K;Anwer, Tarique;Sultana, Yasmin;Sharma, Manju
    • Advances in Traditional Medicine
    • /
    • v.7 no.1
    • /
    • pp.94-99
    • /
    • 2007
  • The present study is aimed at finding the effect of B-20 drops, a homoeopathic formulation, in streptozotocin (STZ) induced diabetic rats. B-20 drops comprises of the constituents derived from plants and other natural sources, and are generally prescribed by the homoeopathic physician, in cases of hyperglycemia and diabetes. The elevated levels of fasting blood glucose and pancreatic lipid peroxides observed in rats treated with STZ were significantly reduced by the treatment of B-20 drops. The reduced liver glycogen contents were also brought back to near normal level by B-20 drops treatment in STZ diabetic rats. STZ induced histopathological changes in pancreas and liver was also partially reversed by B-20 drops. The findings indicate that B-20 drops help in improving the glycogen stores in the liver and prevents STZ induced damage through free radicals by decreasing the pancreatic lipid peroxides levels.

Study on the Detection of Artificial Dyes in the Commercial Drops by Use of Thin-Layer Chromatography (Thin-Layer Chromatography에 의한 시판 알사탕류의 착색료에 관한 고찰)

  • 구성회;우세홍;한식일;이성호
    • Journal of Environmental Health Sciences
    • /
    • v.1 no.1
    • /
    • pp.14-17
    • /
    • 1974
  • A study was carried out to detect of illegal artificial dyes, and to confirm the used rate of illegal dyes in the production process of commercial drops (candy), from Dec. 10, 1972 to Feb. 10, 1973. In this study, it was used thin layer chromatography, the samples were divided into two groups, group A of inscribed trade name and group B of not inscribed trade name. To contrast with group A and group B, 100 samples were randomly collected in the market places, 50 samples from group A and 50 samples from group B. The following conclusions were obtained: 1) used rate of illegal dyes were 2% of group A and 9% of group B. 2) used rate of illegal dyes were 2% of red, 2% of yellow, 1% of violet and 6% of green, not in blue. 3) used rate of illegal dyes 3% of Rhodamine B, 3% of Auramine and 6% of Light green S.F. Yellowish. 4) Out of 20 cases those used mixed dyes, only one case was confirmed as two illegal dyes, and 4 cases were used one illegal dye.

  • PDF

Particle Laden Flows Around Orifice Plates for Pressure Control in Pulverized Coal Pipe Lines (분체 이송관내 압력 조절을 위한 오리피스 주위에서의 입자 유동 및 마모 해석)

  • Cho, Hyung-Hee;Lee, Jae-Keun;Park, Ho-Dong;Seo, Tae-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.11
    • /
    • pp.1499-1508
    • /
    • 1998
  • A numerical study is performed to investigate pressure drops, particle trajectories and erosion around orifice plates in pulverized coal pipe lines. Particle impaction rates change significantly with orifice shapes and Stokes numbers. At Reynolds number of $5{\times}10^5$, the pulverized coal flows well with streamlines and do not collide at the orifice plates at small sizes (${\sim}20{\mu}m$). However, the large particles (over $70{\mu}m$) impact on the front face of the orifice and erode the orifice surface. The pressure loss coefficients around the erode orifice are largely different from the designed original orifice.

A novel wavelength selectable multichannel Optical Add/Drop Multiplexer using sampled grating (샘플격자를 이용한 새로운 파장가변형 다채널 OADM)

  • Lee, Jong-Hun;Cho, Joon-Yong;Lee, Kyung-Shik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.12
    • /
    • pp.43-49
    • /
    • 2000
  • In this paper, a novel wavelength selectable multi-channel OADM(Optical Add/Drop Multiplexers) is proposed and experimentally demonstrated. The proposed OADM drops simultaneously more than one channel among many channels with small wavelength tuning by using one sampled grating and FBGs, Interchannel crosstalk (or interchannel rejection ratio) better than 20[dB] has been shown experimentally.

  • PDF

Effect of liquid viscosity on internal flow and spray characteristics of Y-jet atomizers (액체 점도에 따른 Y-jet 노즐 내부 유동 및 분무 특성의 변화)

  • Song, Si-Hong;Lee, Sang-Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.12
    • /
    • pp.4053-4061
    • /
    • 1996
  • Internal flow characteristics within Y-jet atomizers and the local drop size distribution and cross-sectional averaged drop size at the outside were investigated with the liquid and air injection pressures, mixing port length of atomizers, and the liquid properties taken as parameters. To examine the effect of the liquid viscosity, glycerin-water mixtures were used in this study. The liquid viscosity plays only a minor role in determining the internal flow pattern and the spatial distribution shape of drops, but the drop sizes themselves generally increase with increasing of the liquid viscosity. An empirical correlation for the liquid discharge coefficient at the liquid port was deduced from the experimental results; the liquid discharge coefficient strongly depends on the liquid flow area at the mixing point which is proportional to the local volumetric quality(.betha.$_{Y}$), and the volumetric quality was included in the correlation. Regardless of the value of the liquid viscosity, the compressible flow through the gas port was well represented by the polytropic expansion process(k=1.2), and the mixing point pressure could be simply correlated to the aspect ratio( $l_{m}$/ $d_{m}$) of the mixing port and the air/liquid mass flow rate ratio( $W_{g}$/ $W_{f}$) as reported in the previous study.udy.udy.y.

An Experimental Study on Pressure Drop of Boiling Flow within Horizontal Rectangular Channels with Small Heights (미세 수평 사각 유로 내에서의 비등 유동 압력강하에 관한 실험적 연구)

  • Lee, Sang-Yong;Lee, Han-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.9
    • /
    • pp.1219-1226
    • /
    • 2001
  • Pressure drops were measured for the flow boiling process within horizontal rectangular channels. The gap between the upper and the lower plates of each channel ranges from 0.4 to 2mm while the channel width being fixed to 20mm. Refrigerant 113 was used as the test fluid. The mass flux ranges from 50 to 200kg/㎡s and the channel walls were uniformly heated up to 15kW/㎡. The quality range covers from 0.15 to 0.75. The present experimental conditions coincide with the operating conditions of compact heat exchangers in which the liquid and gas flows are laminar and turbulent. The measured results were well represented by the two-phase frictional multiplier of Lee (2001) which has been developed for air-water two-phase flows within the deviation of $\pm$20%.

A Study on the Amendments of the Cathodic Protection Criteria Considering IR Drops (전압강하를 고려한 전기방식 기준 개정에 관한 연구)

  • Ryou, Young-don;Lee, Jin-han;Jo, Young-do;Kim, Jin-Jun
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.4
    • /
    • pp.50-57
    • /
    • 2016
  • According to the urban gas business legislation, cathodic protection systems should be applied for buried steel gas pipelines to prevent corrosion. In advanced countries including United States, the criteria for Cathodic Protection Potential is at least -850mV with respect to a saturated copper/copper sulfate electrode(CSE) when the CP applied, and the IR drops must be considered for valid interpretation. However, the IR drop through the pipe to soil boundary has been neglected in Korea. According to KGS code, a reference electrode must be placed in proximity to gas pipelines possible when measuring the CP potential. In this study, we have installed several solid reference electrodes around the buried pipeline(1.2m depth), lower surface(0.5m depth), and the surface individually in order to measure the CP potentials through the each reference electrode and find out the IR drops according to the location of each reference electrode. We have found the IR drop is the greatest when measuring the CP potential through the electrode placed on the ground and the IR drop is the smallest through the electrode installed near pipeline. Therefore, we have suggested the solid reference electrode should be installed as close as possible to buried pipeline in order to measure the correct CP potential without IR drop. We have also suggested the amendment of CP criteria considering IR drop.

A Study of Image Quality Improvement Through Changes in Posture and Kernel Value in Neck CT Scanning (경부 CT검사 시 Kernel 값과 검사자세 변화를 통한 화질개선에 관한 연구)

  • Kim, Hyeon-Ju;Chung, Woo-Jun;Cho, Jae-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.59-66
    • /
    • 2011
  • There is a difficulty because of classifying the anatomical structure in the neck CT scan by the beam hardening artifact no more than disease and it including the 6, 7 number cervical spine and intervertebral disk. In case of enforcing the neck CT scan cause of the inner diameter of beam artifact tried to be inquired by the image evaluation according to the change of the image evaluation according to the direction of the shoulder joint applying the variation method of a posture and location and Kernel value and it was most appropriate, the lion tax and Kernel value try to be searched for through an experiment. Somatom Sensation 16 (Siemens, Enlarge, Germany) equipment was used in a patient 30 people coming to the hospital for the neck CT scan. A workstation used the AW 4.4 version (GE, USA). According to a direction and location of the shoulder joint, the patient posture gave a change to the direction of the shoulder joint as the group S it gave a change as three postures and placed the both arms comfortably and helps a group N and augmented unipolar left in the wealthy merchant and group P it memorized the both hands and ordered the eversion and drops below to the utmost and enforced a scan. By using a reconstructing method as the second opinion, it gave and reconstructed the Kernel value a change based on scan data with B 10 (very smooth), B 20 (smooth), B 30 (medium smooth), B 40 (medium), B 50 (medium sharp), B 60 (sharp), and B 70 (very sharp). By using image data which gave the change of the examination posture and change of the Kernel value and are obtained, we analyzed through the noise value measurement and image evaluation of. The outside wire eversion orders the both hands and the examination posture is cost in the neck CT scan with the group P it drops below to the utmost. And in case of when reconstructing with B 40 (medium) or B 50 (medium sharp) being most analyzed into the inappropriate posture and Kernel value and applying the Kernel value to a clinical, it is considered to be very useful.

Study on Pressure Drop Characteristics in Multi-Channel Tubes for Automotive Condenser (자동차 응축기용 다채널관의 압력강하 특성에 관한 연구)

  • Jeon, Chang Duk;Chung, Jae Won;Lee, Jinho;Kang, Shin Hyung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.7
    • /
    • pp.881-892
    • /
    • 1999
  • Experiment was performed to study the characteristics of pressure drop of multi-channel tubes for automotive condenser using HFC-134a. Single phase liquid and two phase flow pressure drop were measured in one rectangular plain and three micro-fin tubes with 10 channels. Data are presented for the following range of variables: mass flux(200 to $600kg/m^2s$), and inlet saturation pressure of the refrigerant(1.0 and 1.6MPa). For subcooled flow, pressure drops are 10% and 12% higher than that predicted by the Petukhov equation with hydraulic diameter respectively. Two-phase flow pressure drop are compared with the previously proposed correlations, and well predicted by modified correlation that was derived from Traviss correlation. and correlated within -30~+20%. Also experimental data are correlated within -56%~+18% by Webb's prediction method based on the equivalent mass velocity concept originally proposed by Akers et al.

A study on the Acceptable Cap Torque for Processed Food Containers (고령자에 적합한 가공식품 마개의 Torque에 관한 연구)

  • Sin, Seung-Heon;Song, Byeong-Chang
    • Journal of the Ergonomics Society of Korea
    • /
    • v.20 no.2
    • /
    • pp.83-97
    • /
    • 2001
  • Korea has become an aged society according to the UN specifications. The number of the aged population will increase drastically, and the number of single aged people will also increase. Products used in our daily life are manufactured within the normal capabilities of people. Thus, aged people have encountering problems in using them. Numerous products are used in our daily lives. The purpose of this study is to find the acceptable torque for aged people to open the caps of processed food containers. Depending on the size and shape of the opening hand, hand operation has been classified into three categories. A total of one hundred and nine people participated in this study. Fifty nine people in the 20-30 year old range and fifty people in their 60-70's. Results of the study are as follows: 1) For all categories the acceptable cap torque data for the aged people are established. To satisfy 95% of the aged people, it was found that $74N{\cdot}cm$ for type A caps, and $141N{\cdot}cm$ for B type caps. and $214N{\cdot}cm$ for type C were the acceptable torque levels. 2) The appropriate level of torque for opening the cap was found to be 70% of the maximum torque for the aged people.(71.4% for type A. 71.4% for type B. 72.2% for type C). 3) Capabilities of the 70's drops sharply in function related to opening cap (maximum torque, gripping force, and wrist movement range). 4) Among aged subjects, 65.0% for type A, 42.0% for type B, and 68.8% for type C, had difficulties in opening the container caps.

  • PDF