• Title/Summary/Keyword: B mode

Search Result 2,448, Processing Time 0.032 seconds

A Coding Mode Image Characteristics-based Fast Direct Mode Decision Algorithm (코딩 모드 영상 특성기반의 고속 직접모드 결정 알고리즘)

  • Choi, Yung-Ho;Han, Soo-Hee;Kim, Lark-Kyo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1199-1203
    • /
    • 2012
  • H.264 adopted many compression tools to increase image data compression efficiency such as B frame bi-directional predictions, the direct mode coding and so on. Despite its high compression efficiency, H.264 can suffer from its long coding time due to the complicated tools of H.264. To realize a high performance H.264, several fast algorithms were proposed. One of them is adaptive fast direct mode decision algorithm using mode and Lagrangian cost prediction for B frame in H.264/AVC (MLP) algorithm which can determine the direct coding mode for macroblocks without a complex mode decision process. However, in this algorithm, macroblocks not satisfying the conditions of the MLP algorithm are required to process the complex mode decision calculation, yet suffering a long coding time. To overcome the problem, this paper proposes a fast direct mode prediction algorithm. Simulation results show that the proposed algorithm can determine the direct mode coding without a complex mode decision process for 42% more macroblocks and, this algorithm can reduce coding time by up to 23%, compared with Jin's algorithm. This enables to encode B frames fast with a less quality degradation.

Bandpass Filter Using Dual-mode Resonator with Radial Stub (래디얼 스터브를 통해 구현된 이중 모드 공진기를 이용한 대역 통과 필터)

  • Yun, Tae-Soon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.3
    • /
    • pp.74-78
    • /
    • 2011
  • In this paper, the bandpass filter for ITS system of 5.8 GHz is proposed by using the dual-mode resonator with the radial stub. As alternating the open stub with the radial stub, the size of the dual mode resonator can be reduced about 39.6% and the out-of-band characteristics of the bandpass filter using dual mode resonator can be enhanced from 19.4 dB to 29.1 dB by using the stub of $6.9{\Omega}$ i.e. realized by parallel two radial stubs with $60^{\circ}$ angle. The fabricated bnadpass filter using the dual mode resonator has the center frequency of 5.72 GHz with the fractional bandwidth of 4.1%. Also, the filter has the insertion loss and return loss of 1.79 dB and 19.4 dB, respectively.

Genetic and of environmental effects for economic traits in pigs (돼지 주요 경제형질들에 영향을 미치는 유전 및 환경효과 추정)

  • Lee, Ill-Joo;Hong, Joon-Ki;Kim, Du-Wan;Sa, Soo-Jin;Kim, Young-Hwa;Cho, Kyu-Ho
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.4
    • /
    • pp.347-351
    • /
    • 2013
  • This study was conducted to estimate the effect of sex, breed and on the basis of the records on 300 pigs of Duroc, Landrace and Yorkshire breeds raised at the National Institute of Animal Science. Yorkshire was observed to be superior to other breeds between 90 to 110 kg of body weight. Thicker backfat was estimated in the B-mode than in A-mode of 110 kgs range than in 90 kgs. Loin eye muscle area was larger in the final weight of 110kg than in 90 and the Duroc had significantly (p<0.05) larger loin eye muscle area than other breeds. Thinner backfat was observed in males than in females in both modes of backfat measurements and in both of the final weights of test. Females had significantly larger loin eye muscle area than males, and the difference between the two sexes were larger in the final weight of 110 kg than in 90 kg. Analysis models concluded that backfat thickness certainly influences the body weight gain when at 90 kgs and 110 kgs analysed with A-mode and B-mode respectively.

26GHz 40nm CMOS Wideband Variable Gain Amplifier Design for Automotive Radar (차량용 레이더를 위한 26GHz 40nm CMOS 광대역 가변 이득 증폭기 설계)

  • Choi, Han-Woong;Choi, Sun-Kyu;Lee, Eun-Gyu;Lee, Jae-Eun;Lim, Jeong-Taek;Lee, Kyeong-Kyeok;Song, Jae-Hyeok;Kim, Sang-Hyo;Kim, Choul-Young
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.408-412
    • /
    • 2018
  • In this paper, a 26GHz variable gain amplifier fabricated using a 40nm CMOS process is studied. In the case of an automobile radar using 79 GHz, it is advantageous in designing and driving to drive down to a low frequency band or to use a low frequency band before up conversion rather than designing and matching the entire circuit to 79 GHz in terms of frequency characteristics. In the case of a Phased Array System that uses time delay through TTD (True Time Delay) in practice, down conversion to a lower frequency is advantageous in realizing a real time delay and reducing errors. For a VGA (Variable Gain Amplifier) operating in the 26GHz frequency band that is 1/3 of the frequency of 79GHz, VDD : 1V, Bias 0.95V, S11 is designed to be <-9.8dB (Mea. High gain mode) and S22 < (Mea. high gain mode), Gain: 2.69dB (Mea. high gain mode), and P1dB: -15 dBm (Mea. high gain mode). In low gain mode, S11 is <-3.3dB (Mea. Low gain mode), S22 <-8.6dB (Mea. low gain mode), Gain: 0dB (Mea. low gain mode), P1dB: -21dBm (Mea. Low gain mode).

Usefulness of Twinkling Artifacts in Color Doppler Ultrasonography (컬러 도플러 초음파에서 Twinkling artifacts의 유용성)

  • Sim, Hyun-Sun;Kwon, Kyung-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.10
    • /
    • pp.291-298
    • /
    • 2016
  • The aim of the study was to investigate the diagnostic value of the color Doppler twinkling artifact in disease of urinary system. The intensity of twinkling artifact(TA) with color Doppler was classified into 3 levels, 0(non-TA) to 3(distinct TA). In the in vitro study, acorn jelly with various materials on top was examined using color Doppler at B-mode sonography in a water bath for TA. 31 patients with diagnosis of urinary calculi(renal stones 16, urinary stones 15) based on B-mode sonography were studied in vivo for TA. The materials with rough surfaces such as salt, screw and cubics at B-mode sonography with color Doppler contributed to causing TA. At B-mode sonography without color Doppler 37% of renal stones and 60% of ureter stones were detected. but at B-mode sonography with color Doppler TA was demonstrated for all cases. Superficial roughness of materials affected occurrence of TA at B-mode sonography with color Doppler. Therefore, TA at B-mode sonography without color Doppler could play a role in confident diagnosis of the disease of urinary system.

Low Splicing Loss Technique between Standard Single Mode Fiber and High Δ Fiber (표준 단일모드 광섬유와 하이델타 광섬유사이의 저 손실 접속 기법)

  • Kim, Kwang-Taek;Yang, Byoung-Cheoul
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.3
    • /
    • pp.169-174
    • /
    • 2008
  • In this paper, we have presented techniques to reduce the splicing loss between standard single mode fiber and high ${\Delta}$ single mode fiber based on the mode expanding and mode evolution induced by thermal treatment of the fibers. The experimental results show that mechanical splicing loss can be reduced from 2.3 dB to 0.1 dB through proper thermal treatment of the high ${\Delta}$ fiber. Meanwhile, we achieved $0.2{\sim}0.4dB$ of low splicing loss between two fibers by heating the splicing region using electric arcing or an oxygen flame.

Design of Compact Common Mode Noise Absorption Filter (공통 모드 노이즈를 흡수하는 소형 공통 모드 필터 설계)

  • Jung, Hyeonjong;Jung, Jinwoo;Lim, Yeongseog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.12
    • /
    • pp.963-968
    • /
    • 2018
  • In this paper, a compact common mode filter using passive elements is designed and fabricated. To design a common mode filter with required frequency response, the equivalent circuits of the common mode filter in differential mode and common mode were analyzed. Compared with the former filter using a ${\lambda}/4$ resonator, the size of the proposed structure was reduced by 60 %. The fabricated common mode filter has a maximum differential mode insertion loss of 1.2 dB and a minimum common mode absorption efficiency of 78.2% in the CMA - bandwidth of 27.5 %.

Fast Macroblock Mode Selection Algorithm for B Frames in Multiview Video Coding

  • Yu, Mei;He, Ping;Peng, Zongju;Zhang, Yun;Si, Yuehou;Jiang, Gangyi
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.5 no.2
    • /
    • pp.408-427
    • /
    • 2011
  • Intensive computational complexity is an obstacle of enabling multiview video coding for real-time applications. In this paper, we present a fast macroblock (MB) mode selection algorithm for B frames which are based on the computational complexity analyses between the MB mode selection and reference frame selection. Three strategies are proposed to reduce the coding complexity jointly. First, the temporal correlation of MB modes between current MB and its temporal corresponding MBs is utilized to reduce computational complexity in determining the optimal MB mode. Secondly, Lagrangian cost of SKIP mode is compared with that of Inter $16{\times}16$ modes to early terminate the mode selection process. Thirdly, reference frame correlation among different Inter modes is exploited to reduce the number of reference frames. Experimental results show that the proposed algorithm can promote the encoding speed by 3.71~7.22 times with 0.08dB PSNR degradation and 2.03% bitrate increase on average compared with the joint multiview video model.

Classifying Midair Collision Risk in Airspace Using ADS-B and Mode-S Open-source Data (ADS-B와 Mode-S 오픈소스 데이터를 활용한 공중충돌 위험 양상 분류)

  • Jongboo Kim;Dooyoul Lee
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.5
    • /
    • pp.552-560
    • /
    • 2023
  • Aircraft midair collisions are dangerous events that can cause massive casualties. To prevent this, civil aviation has mandated the installation of TCAS (ACAS), which is becoming more sophisticated with the help of new technologies. However, there are institutional problems in collecting data for TCAS research in Korea, limiting the ability to obtain data for personal research. ADS-B and Mode-S automatic broadcast various information about the flight status of the aircraft. This data also contains information about TCAS RA, which can be used by anyone to find examples of TCAS RA operation. We used the databases of ADS-B Exchange and Opensky-Network to acquire data and visually represent three TCAS RA cases through Python coding. We also identified domestic TCAS cases in the first half of 2023 and analyzed their characteristics to confirm the usefulness of the data.

A Study on Changes in Body Surface Temperature and Thermal Effect According to Ultrasound Mode (초음파 진단모드에 따른 체표면 온도변화와 열효과에 관한 고찰)

  • Yang, Sung-Hee;Lee, Jin-Soo
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.213-218
    • /
    • 2017
  • Recently, as the number of high-risk pregnancies increases, the use of new techniques such as Doppler, which have higher acoustic power than in the past, has been increasingly used in prenatal diagnosis and guidelines have been set up by various organizations to prevent excessive exposure. Therefore, in this study, we tried to investigate the temperature change of the body surface for each test mode according to the long time ultrasound examination and to examine the exposure time which is not influenced by the thermal effect. B mode, C mode, and PD mode according to time, and the temperature difference between exposed and unexposed sites were compared. As a result, the B mode showed a significant difference in the temperature change from 10 minutes, 50 minutes after exposed, 20 minutes from the C mode, and 30 minutes from the PD mode (p<0.01). In all three modes, the temperature difference was different (p<0.000), and PD mode was the most sensitive to temperature change. Also, it was found that the temperature rise time was shortened with the increase of the ultrasonic exposure time. Therefore, it is recommended that ultrasonography to observe the embryo or fetus should be used only for diagnostic purposes, avoiding excessive test time.