• Title/Summary/Keyword: B mode

Search Result 2,448, Processing Time 0.025 seconds

Comparison of Characteristics between $L_1-B_4$ mode and $L_1-B_8$ mode Ultrasonic Motors ($L_1-B_4$모드와 $L_1-B_8$모드 초음파 선형 전동기의 특성 비교)

  • U, Sang-Ho;Kim, Dong-Yeon;Kim, Jin-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1518-1520
    • /
    • 2002
  • Purpose of this research compares best transfer speed about applied frequency and voltage using characteristic of $L_1-B_4$ mode and $L_1-B_8$ mode linear ultrasonic motor that use piezoelectric effect. By method of study, analyzed best transfer speed measuring and comparison load status that use actuality telephone card in $L_1-B_4$ mode linear ultrasonic motor and no-load status of $L_1-B_8$ mode linear ultrasonic motor. Experiment result is applied frequency(58.4Hz) in $L_1-B_4$ mode linear ultrasonic motor (load state) and the best transfer speed by 19.8[cm/s] at applied voltage(56V) point. Also, $L_1-B_8$ mode linear ultrasonic motor (no-load state) is best transfer speed by applied frequency(27.9kHz) and 32.96[cm/s] at applied voltage (50V) point.

  • PDF

Effects of Refraction of Ultrasonic Beam on B-mode Tomograms (B-mode 단층상에서의 초음파 빔의 굴절 영향)

  • 최종수
    • Journal of Biomedical Engineering Research
    • /
    • v.2 no.2
    • /
    • pp.141-144
    • /
    • 1981
  • This paper descirbes about effects of refraction of ultrasonic beam on B-mode tomogram. Both compution based on Snell's law and the experiments performed using B-mode scanner and schlieren optical method are discussed on a circular phantom immersed in water. In these results, if the discrepancy of sound velocity is more than 0. 6%, the distortion of the B-mode image becomes conspicuous and a target beyound the phantom may disappear or displayed as two targets depending on the velocity of the phantom.

  • PDF

Evaluation of Skin Dose and Image Quality on Cone Beam Computed Tomography (콘빔CT 촬영 시 mAs의 변화에 따른 피부선량과 영상 품질에 관한 평가)

  • Ahn, Jong-Ho;Hong, Chae-Seon;Kim, Jin-Man;Jang, Jun-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose: Cone-beam CT using linear accelerator attached to on-board imager is a image guided therapy equipment. Because it is to check the patient's set-up error, correction, organ and target movement. but imaging dose should be cause of the secondary cancer when taking a image. The aim of this study is investigation of appropriate cone beam CT scan mode to compare and estimate the image quality and skin dose. Materials and Methods: Measurement by Thermoluminescence dosimeter (TLD-100, Harshaw) with using the Rando phantom are placed on each eight sites in seperately H&N, thoracic, abdominal section. each 4 methods of scan modes of are measured the for skin dose in three time. Subsequently, obtained average value. Following image quality QA protocol of equipment manufacturers using the catphan 504 phantom, image quality of each scan mode is compared and analyzed. Results: The results of the measured skin dose are described in here. The skin dose of Head & Neck are measured mode A: 8.96 cGy, mode B: 4.59 cGy, mode C: 3.46 cGy mode D: 1.76 cGy and thoracic mode A: 9.42 cGy, mode B: 4.58 cGy, mode C: 3.65 cGy, mode D: 1.85 cGy, and abdominal mode A: 9.97 cGy, mode B: 5.12 cGy, mode C: 4.03 cGy, mode D: 2.21 cGy. Approximately, dose of mode B are reduced 50%, mode C are reduced 60%, mode D are reduced 80% a point of reference dose of mode A. the results of analyzed HU reproducibility, low contrast resolution, spatial resolution (high contrast resolution), HU uniformity in evaluation item of image quality are within the tolerance value by recommended equipment manufacturer in all scan mode. Conclusion: Maintaining the image quality as well as reducing the image dose are very important in cone beam CT. In the result of this study, we are considered when to take mode A when interested in soft tissue. And we are considered to take mode D when interested in bone scan and we are considered to take mode B, C when standard scan. Increasing secondary cancer risk due to cone beam CT scan should be reduced by low mAs technique.

  • PDF

Ductile Fracture Behaviour of SA 533B Pressure Vessel Steel Under Mixed Mode (I/II) Loading (혼합 모드(I/II) 하중에 의한 SA533B 압력용기강의 연성파괴 특성에 관한 연구)

  • O, Dong-Jun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.11
    • /
    • pp.1829-1834
    • /
    • 2001
  • The aim of this study is to investigate the ductile fracture behavior under mixed mode (I/II) loading using SA533B pressure vessel steel. Anti-symmetric 4-point (AS4P) bonding tests were performed to obtain the J-R curves under two different mixed mode (I/II) loadings. In addition, the fractographic examination of fracture surfaces was carried out to compare with those of pure Mode I and Mode II. In conclusions, the J-R curves under Mixed Mode (I/II) loading were located between those of Mode I and Mode II loadings. When the mixture ratio of mixed mode (I/II) loading was high, the J-R currie of mixed mode (I/II) loading approached that of pure mode I loading after some amount of crack propagation. In contrast with the above fact, if the mixture ratio was low, the J-R curve looked after that of pure mode II loading. The fractographic evidences such as the shape of dimples under different loading conditions supported these conclusions.

Study of Absorbed Dose and Effective Dose for Prostate Cancer Image Guided Radiation Therapy using kV Cone Beam Computed Tomography (kV Cone Beam Computed Tomography (CBCT)를 이용한 전립선암 영상유도방사선치료 시 흡수선량 및 유효선량에 관한 고찰)

  • Na, Jong-Eok;Lee, Do-Geun;Kim, Jin-Soo;Baek, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.67-74
    • /
    • 2009
  • Purpose: To evaluate the results of absorbed and effective doses using two different modes, standard mode (A-mode) and low-dose mode (B-mode) settings for prostate cancer IGRT from CBCT. Materials and Methods: This experimental study was obtained using Clinac iX integrated with On Board Imager (OBI) System and CBCT. CT images were obtained using a GE Light Speed scanner. Absorbed dose to organs from ICRP recommendations and effective doses to body was performed using A-mode and B-mode CBCT. Measurements were performed using a Anderson rando phantom with TLD-100 (Thermoluminescent dosimeters). TLD-100 were widely used to estimate absorbed dose and effective dose from CBCT with TLD System 4000 HAWSHAW. TLD-100 were calibrated to know sensitivity values using photon beam. The measurements were repeated three times for prostate center. Then, Evaluations of effective dose and absorbed dose were performed among the A-mode and B-mode CBCT. Results: The prostate absorbed dose from A-mode and B mode CBCT were 5.5 cGy 1.1 cGy per scan. Respectively Effective doses to body from A mode and B-mode CBCT were 19.1 mSv, 4.4 mSv per scan. Effective dose from A-mode CBCT were approximately 4 times lower than B-mode CBCT. Conclusion: We have shown that it is possible to reduce the effective dose considerably by low dose mode(B-mode) or lower mAs CBCT settings for prostate cancer IGRT. Therefore, we should try to select B-mode or low condition setting to decrease extra patient dose during the IGRT for prostate cancer as possible.

  • PDF

A novel mode shape converter for polymer Rib waveguide (폴리머 립 광도파로를 위한 새로운 모드 모양 변화기)

  • 김덕봉;조정환;이상윤;장우혁;이태형
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.2
    • /
    • pp.119-122
    • /
    • 2000
  • We proposed a novel mode shape converter (MSC) that can effectively reduce the coupling loss between polymer rib waveguide and single mode fiber. The double-nb geometry that was used in the novel MSC converted an elliptical mode to circular mode and an circular mode to elliptical mode. This structure can be easily realized by using the typical fabrication process for polymer wavegUide. Simulation using a three dimensional beam propagation method showed that the novel MSC has a coupling loss of 0.079 dB/facet and total lllsertioll loss of less than 0.2 dB. .2 dB.

  • PDF

THREE DIMENSIONAL CHARACTERISTICS OF WAKES OVER A CIRCULAR CYLINDER IN THE B-MODE USING HIGH ORDER SCHEME (고해상도 수치기법에 의한 B-Mode 영역에서 원형실린더 주위의 3차원 후류 유동특성 연구)

  • Kim, T.S.;Lee, S.S.;Kim, J.S
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03a
    • /
    • pp.50-56
    • /
    • 2008
  • 본 논문에서는 실린더 주위유동의 B-mode에 해당하는 레이놀즈 수 300${\sim}$1000범위에서 고차 고해상도기법(OHOC Scheme)을 이용하여 원형 실린더 주위의 유동장 및 음향장 특성에 대해서 연구하였다. B-mode 레이놀즈 수 범위에서 스팬방향 길이에 따른 3차원 원형실린더의 스트롤 수, 양 항력계수의 상관관계에 대해 수치계산 및 실험 결과와 비교 분석한 결과 매우 잘 일치하는 것을 보였다. 그리고 이 결과를 토대로 하여 B-mode 불안정성 영역에서 보다 정확한 2차 와류 모사를 위한 적절한 스팬방향을 찾고, 3차원 후류유동의 불안정성이 음향장의 변화에 미치는 영향을 정성적으로 고찰하여, 3차원 원형실린더의 공력소음 대한 기초적인 연구를 수행하였다.

  • PDF

THREE DIMENSIONAL CHARACTERISTICS OF WAKES OVER A CIRCULAR CYLINDER IN THE B-MODE USING HIGH ORDER SCHEME (고해상도 수치기법에 의한 B-Mode 영역에서 원형실린더 주위의 3차원 후류 유동특성 연구)

  • Kim, T.S.;Lee, S.S.;Kim, J.S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.50-56
    • /
    • 2008
  • 본 논문에서는 실린더 주위유동의 B-mode에 해당하는 레이놀즈 수 $300{\sim}1000$범위에서 고차 고해상도 기법(OHOC Scheme)을 이용하여 원형 실린더 주위의 유동장 및 음향장 특성에 대해서 연구하였다. B-mode 레이놀즈 수 범위에서 스팬방향 길이에 따른 3차원 원형실린더의 스트롤 수, 양 항력계수의 상관관계에 대해 수치계산 및 실험 결과와 비교 분석한 결과 매우 잘 일치하는 것을 보였다. 그리고 이 결과를 토대로 하여 B-mode 불안정성 영역에서 보다 정확한 2차 와류 모사를 위한 적절한 스팬방향을 찾고, 3차원 후류유동의 불안정성이 음향장의 변화에 미치는 영향을 정성적으로 고찰하여, 3차원 원형실린더의 공력소음 대한 기초적인 연구를 수행하였다.

  • PDF

0.18mm CMOS LNA/Mixer for UHF RFID Reader (UHF RFID 리더를 위한 0.18mm CMOS LNA/Mixer)

  • Woo, Jung-Hoon;Kim, Young-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.2
    • /
    • pp.45-49
    • /
    • 2009
  • In this paper, a direct down conversion LNA/Mixer has been designed and tested for 900Mhz UHF RFID application. The designed circuit has been implemented in 0.18um CMOS technology with 3.3V operation. In this work, a common gate input architecture has been used to cope with the higher input self jamming level. This LNA/Mixer is designed to support two operating modes of high gain mode and low gain mode according to the input jamming levels. The measured results show that the input referred P1dBs are 4dBm of high gain mode and 11dBm of low gain mode, and the conversion gains are 12dB and 3dB in high and low gain mode respectively The power consumptions are 60mW for high gain mode and 79mW for low gain mode. The noise figures are 16dB and 20dB in high gain mode and low gain mode respectively.

Fabrication and Characterization of Surface Plasmon Fiber-Optic Polarizers (표면 플라즈몬 광섬유 편광기의 제작 및 특성 조사)

  • 김진하;김병윤
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.311-318
    • /
    • 1994
  • We fabricated fiber-optic polarizers utilizing polarization selective mode coupling between the guided mode of a fiber and the surface plasmon mode supported by a thin aluminium film deposited on the polished side of a fiber. AI thin films with various thicknesses were coated onto the 633 nm, 830 nm, 1.3 fJITI single mode fibers. The maximum extinction ratio was higher than 30 dB for most of the samples and the best result was 42 dB at 90 A film thickness, with 1.3 fJITI single mode fiber. The insertion loss ranged from 0.2 dB to 1.5 dB.1.5 dB.

  • PDF