• Title/Summary/Keyword: B 계통

Search Result 876, Processing Time 0.025 seconds

Demonstration Analysis of 3kW Grid Connected PV System (3kW급 계통연계형 태양광발전시스템 실증연구)

  • Choi Y.O.;Piao Z.G.;Jeong S.B.;Cho G.B.;Baek H.L.
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.558-560
    • /
    • 2006
  • Solar cell converts sunlight into the electricity that one of the most versatile forms of energy. It has been developed and applied on residental electric power system by urbanized countries as a alternative energy source to overcome energy problem after oil shock. This paper summarizes the results of these efforts by offering a snapshot of the configuration of photovoltaic in residential applications. The status of PV system components and inter-connection and safety equipment will be summarized. Hence this paper discusses only points that might be useful for application.

  • PDF

A New Control Algorithm of Series Active Power Filter for Harmonic Reduction in Power System (전력계통 시스템에서 고조파 저감을 위한 새로운 직렬형 능동전력필터의 제어법)

  • Lim, Seung-Won;Han, Yoon-Seok;Kim, Young-Seok;Won, Chung-Yuen;Choi, Se-Wan
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.5
    • /
    • pp.221-228
    • /
    • 2001
  • In this paper, a new control algorithm of series active power filter is proposed to reduce harmonic generated from nonlinear load in power system. In conventional control algorithm, harmonic current must be calculated firstly, and then compensation voltage was calculated by using the results but the proposed control algorithm can calculate compensation voltage directly. Compensating principle of proposed control algorithm is presented in detail. A combined system of series active filter and passive filter is composed in order to experiment. Experiment was carried out to verify proposed control algorithm of series active filter and experimental results are analyzed.

  • PDF

Analysis of ANSI/IEEE Standard & Short-Circuit Calculations according to RTDS (ANSI/IEEE 기술규격 분석 및 RTDS에 의한 고장전류 계산 비교)

  • Cha, S.T.;Choo, J.B.;Yoon, Y.B.;Kim, J.C.;Kim, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.231-233
    • /
    • 2002
  • 본 논문에서는 국제기술규격인 ANSI/IEEE의 고장전류 계산기준을 분석하였고, 외국 전력사의 고장전류 계산 기준을 정리하였다. 계통에서의 차단기 용량 선정은 고장전류 크기가 시간 경과에 따라 다르게 됨으로 차단기 차단시간(interrupting time)특성을 복합적으로 고려하여야 한다. 그러나, 현재 한전에서 사용하고 있는 고장전류 계산은 별도의 차단기 차단시간을 고려한 배수(multiplying factor)를 고려하지 않고 동기발전기 차과도 임피던스만 고장전류 공급원으로 취급하여 계산하고 있다. 이에 본 논문에서는 ANSI/IEEE규격에서 권장하는 내용과 외국 전력사의 고장전류 계산 기준을 종합 정리하였고, 고장전류 계산 예를 한전사용(PSS/E) 및 RTDS를 이용한 경우로 나누어 수행하고 모의 결과를 제시하고자 한다.

  • PDF

Development of Power System Sensitivity Program for Enhanced Energy Management System (EMS 기능고도화의 실현을 위한 계통 민감도 계산 프로그램 개발)

  • Choi, Heung-Kwan;NamKung, Jae-Yong;Moon, Young-Hwan;Nam, Hae-Kon
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.297-299
    • /
    • 1999
  • The B-coefficient method is well-known and universally used method for its simplicity and computation speed. However, the B-coefficient method has a weak point of accuracy when it is applied to the ill-conditioned systems where generators produce excessive reactive power. This paper describes the developed module to be applied to commercial program package of calculating the penalty factors by Jacobian method. The effectiveness of the proposed program has been demonstrated using the IEEE 30 bus system.

  • PDF

Qualification Test of a Main Coolant Pump for SMART Pilot (SMART 연구로 주냉각재펌프의 검증시험)

  • Park, Sang-Jin;Yoon, Eui-Soo;Oh, Hyoung-Woo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.9 s.252
    • /
    • pp.858-865
    • /
    • 2006
  • SMART Pilot is a multipurpose small capacity integral type reactor. Main coolant pump (MCP) of SMART Pilot is a canned-motor-type axial pump to circulate the primary coolant between nuclear fuel and steam generator in the primary system. The reactor is designed to operate under condition of $310^{\circ}C$ and 14.7MPa. Thus MCP has to be tested under same operating condition as reactor design condition to verify its performance and safety. In present wort a test apparatus to simulate real operating situations of the reactor has been designed and constructed to test MCP. And then functional tests, performance tests, and endurance tests have been carried out upon a prototype MCP. Canned motor characteristics, homologous head/torque curves, coast-down curves, NPSH curves and lift-time performance variations were obtained from the qualification test as well as hydraulic performance characteristics of MCP.

An EMTDC Analysis for Ground Faults with a Superconducting Fault Current Limiter (초전도 한류기를 포함한 계통의 지락사고에 대한 EMTDC 해석)

  • Choe, Hyo-Sang;Hyeon, Ok-Bae;Go, Tae-Guk
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.4
    • /
    • pp.161-166
    • /
    • 1999
  • We have performed an EMTDC simulation for the current limiting effects of a superconducting fault current limiter (SFCL). The fault currents in the 154 kV transmission line between the arbitrary S1 and S2 substations increased up to 39 kA during the single and double line-to-ground faults, respectively. The SFCL in the transmission line is sufficient.

  • PDF

Grid Connection Algorithm for Doubly-Fed Induction Generator Using Rotor Side PWM Inverter-Converter (회전자측 PWM 인버터-컨버터를 사용한 이중여자 유도형 풍력 발전기의 계통 투입 알고리즘)

  • 정병창;권태화;송승호;김일환
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.10
    • /
    • pp.528-534
    • /
    • 2003
  • A grid connection algorithm is proposed for the doubly-fed induction generator (DFIG) which is widely adopted in high power variable speed wind turbine. Before the stator of DFIG is connected to grid, rotor-side converter is used to control the induced stator voltage. As a result, the stator transient current is limited below the rate value during the connection by the proposed synchronization of the stator voltage to the grid voltage. A wind power generation simulator using DC motor and wound-rotor induction generator is built and the dynamic characteristics of proposed algorithm is verified experimentally.

Instantaneous Voltage Sag Corrector in Distribution Line Using Series Compensator (배전계통에서의 직렬보상을 이용한 순시전압강하 보상기)

  • Lee, Sang-Hoon;Choi, Jae-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.1
    • /
    • pp.15-22
    • /
    • 2001
  • In this paper, a VSC(Voltage Sag Corrector) is discussed for the purpose of power quality enhancement. A fast detecting technique of voltage sag is accomplished through the detection of instantaneous value on synchronous reference frame. A robust characteristic against the noise is available by inserting the first order low pass filter in the detection circuit. The formula and the filter design process is described properly with the mathematical equations. Because the VSC system supply the active power to load, it is required to design the proper size of the energy storage system, In this paper, the capacitor bank is used as an energy storage system, and the size of the capacitor is designed from the point of view of input/output energy as the output power rating and the amplitude and duration time of the voltage sag. The simulation is accomplished by PSCAD/EMTDC.

  • PDF

A fault location algorithm using current distribution factors for D/S (전류분배계수를 이용한 배전계통 고장점 표정 알고리즘)

  • Lee, D.S.;Jin, B.G.;Lee, S.J.;Choi, M.S.;Kang, S.H.;Ahn, B.S.;Yoon, N.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.275-277
    • /
    • 2001
  • This paper presents a fault location algorithm using current distribution factors for distribution feeder systems. When a fault occurs in distribution system, an accurate fault distance is important for fast fault restoration. The proposed algorithm achieves a high accuracy using negative sequence circuit with various fault conditions.

  • PDF

A fault location algorithm using iterative method at unbalance conditions for distribution feeder systems (불평형시 반복추정기법을 이용한 배전계통 고장점 표정 알고리즘)

  • Lee, D.S.;Jin, B.G.;Lee, S.J.;Choi, M.S.;Kang, S.H.;Ahn, B.S.;Yoon, N.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.121-123
    • /
    • 2001
  • This paper presents a fault location algorithm using iterative method at unbalance condition for distribution feeder systems. Distribution feeders include single phase and three phase laterals. The proposed algorithm achieves a high accuracy by continuously updating voltage and current phasor using the phase components and admittance load model.

  • PDF