• Title/Summary/Keyword: B/C analysis

Search Result 6,323, Processing Time 0.048 seconds

Isolation and Identification of a Photosensitizer from Pueraria thunbergiana Leaves that Induces Apoptosis in SK-HEP-1 Cells (P. thunbergiana 잎으로부터 SK-HEP-1세포에 대한 apoptosis를 유도하는 광과민성물질의 분리 및 구조동정)

  • Lee, Jun Young;Kim, Mi Kyeong;Ha, Jun Young;Kim, Yong Gyun;Hong, Chang Oh;Kim, So Young;Kim, Chung-Hwan;Kim, Keun Ki
    • Journal of Life Science
    • /
    • v.24 no.3
    • /
    • pp.242-251
    • /
    • 2014
  • The objective of this study was to isolate a photosensitizer from Pueraria thunbergiana leaves that induces apoptosis in SK-HEP-1 cells. Column chromatography and thin layer chromatography were used to isolate active compounds from extracts of P. thunbergiana leaves. The structures of the isolated compounds were determined by 1D-NMR, 2D-NMR, and FAB-mass spectroscopy. A substance, named M4-3, was purified from the leaves of P. thunbergiana using various chromatography methods, and the absorbance of the substance was measured. The absorbance was highest at 410 nm, suggesting that the M4-3 substance was a different compound from chlorophyll a and b, which absorb at 410, 502, 533, and 607 nm. Further analyses revealed that the M4-3 compound was a $13^2$-hydoxy pheophorbide, a methyl ester with a molecular weight of 662. M4-3 was identified as a derivative compound of pheophorbide, with a structure that magnesium comes away from the porphyrin ring. The results of the analysis of the cytotoxicity of the M4-3 substance against the SK-HEP-1 cells revealed that it inhibited rates of cell growth by 40% and 80% at a concentration of 0.04 ${\mu}M$ and 0.08 ${\mu}M$, respectively. The M4-3 compound was found to be a photosensitizer for cytotoxicity because it was appeared only in light condition as examining activity in different irradiation conditions (light condition and nonlight condition) under the same concentration. Analysis of morphological changes in the cells following cell death induced by exposure to the M4-3 substance reveled representative phenomena of apoptosis (nuclear condensation, vesicle formation, and fragmentation of DNA). The induction of apoptosis was attributed to the compound's photodynamic activity.

The Brand Personality Effect: Communicating Brand Personality on Twitter and its Influence on Online Community Engagement (브랜드 개성 효과: 트위터 상의 브랜드 개성 전달이 온라인 커뮤니티 참여에 미치는 영향)

  • Cruz, Ruth Angelie B.;Lee, Hong Joo
    • Journal of Intelligence and Information Systems
    • /
    • v.20 no.1
    • /
    • pp.67-101
    • /
    • 2014
  • The use of new technology greatly shapes the marketing strategies used by companies to engage their consumers. Among these new technologies, social media is used to reach out to the organization's audience online. One of the most popular social media channels to date is the microblogging platform Twitter. With 500 million tweets sent on average daily, the microblogging platform is definitely a rich source of data for researchers, and a lucrative marketing medium for companies. Nonetheless, one of the challenges for companies in developing an effective Twitter campaign is the limited theoretical and empirical evidence on the proper organizational usage of Twitter despite its potential advantages for a firm's external communications. The current study aims to provide empirical evidence on how firms can utilize Twitter effectively in their marketing communications using the association between brand personality and brand engagement that several branding researchers propose. The study extends Aaker's previous empirical work on brand personality by applying the Brand Personality Scale to explore whether Twitter brand communities convey distinctive brand personalities online and its influence on the communities' level or intensity of consumer engagement and sentiment quality. Moreover, the moderating effect of the product involvement construct in consumer engagement is also measured. By collecting data for a period of eight weeks using the publicly available Twitter application programming interface (API) from 23 accounts of Twitter-verified business-to-consumer (B2C) brands, we analyze the validity of the paper's hypothesis by using computerized content analysis and opinion mining. The study is the first to compare Twitter marketing across organizations using the brand personality concept. It demonstrates a potential basis for Twitter strategies and discusses the benefits of these strategies, thus providing a framework of analysis for Twitter practice and strategic direction for companies developing their use of Twitter to communicate with their followers on this social media platform. This study has four specific research objectives. The first objective is to examine the applicability of brand personality dimensions used in marketing research to online brand communities on Twitter. The second is to establish a connection between the congruence of offline and online brand personalities in building a successful social media brand community. Third, we test the moderating effect of product involvement in the effect of brand personality on brand community engagement. Lastly, we investigate the sentiment quality of consumer messages to the firms that succeed in communicating their brands' personalities on Twitter.

Analysis of Hydrodynamics in a Directly-Irradiated Fluidized Bed Solar Receiver Using CPFD Simulation (CPFD를 이용한 태양열 유동층 흡열기의 수력학적 특성 해석)

  • Kim, Suyoung;Won, Geunhye;Lee, Min Ji;Kim, Sung Won
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.535-543
    • /
    • 2022
  • A CPFD (Computational particle fluid dynamics) model of solar fluidized bed receiver of silicon carbide (SiC: average dp=123 ㎛) particles was established, and the model was verified by comparing the simulation and experimental results to analyze the effect of particle behavior on the performance of the receiver. The relationship between the heat-absorbing performance and the particles behavior in the receiver was analyzed by simulating their behavior near bed surface, which is difficult to access experimentally. The CPFD simulation results showed good agreement with the experimental values on the solids holdup and its standard deviation under experimental condition in bed and freeboard regions. The local solid holdups near the bed surface, where particles primarily absorb solar heat energy and transfer it to the inside of the bed, showed a non-uniform distribution with a relatively low value at the center related with the bubble behavior in the bed. The local solid holdup increased the axial and radial non-uniformity in the freeboard region with the gas velocity, which explains well that the increase in the RSD (Relative standard deviation) of pressure drop across the freeboard region is responsible for the loss of solar energy reflected by the entrained particles in the particle receiver. The simulation results of local gas and particle velocities with gas velocity confirmed that the local particle behavior in the fluidized bed are closely related to the bubble behavior characterized by the properties of the Geldart B particles. The temperature difference of the fluidizing gas passing through the receiver per irradiance (∆T/IDNI) was highly correlated with the RSD of the pressure drop across the bed surface and the freeboard regions. The CPFD simulation results can be used to improve the performance of the particle receiver through local particle behavior analysis.

A Study on the Choice of Export Payment Types by Applying the Characteristics of the New Trade & Logistics Environment (신(新)무역물류환경의 특성을 적용한 수출대금 결제유형 선택연구)

  • Chang-bong Kim;Dong-jun Lee
    • Korea Trade Review
    • /
    • v.48 no.4
    • /
    • pp.303-320
    • /
    • 2023
  • Recently, import and export companies have been using T/T remittance and Surrender B/L more frequently than L/C when selecting the process and method of trade payment settlement. The new trade and logistics environment is thriving in the era of the Fourth Industrial Revolution (4IR). Document-based trade transactions are undergoing a digitalization as bills of lading or smart contracts are being developed. The purpose of this study is to verify whether exporters choose export payment types based on negotiating factors. In addition, we would like to discuss the application of the characteristics of the new trade and logistics environment. Data for analysis was collected through surveys. The collection method consisted of direct visits to the company, e-mail, fax, and online surveys. The survey distribution period is from February 1, 2023, to April 30, 2023. The questionnaire was distributed in 2,000 copies, and 447 copies were collected. The final 336 copies were used for analysis, excluding 111 copies that were deemed inappropriate for the purpose of this study. The results of the study are shown below. First, among the negotiating factors, the product differentiation of exporters did not significantly affect the selection of export payment types. Second, among the negotiating factors, the greater the purchasing advantage recognized by exporters, the higher the possibility of using the post-transfer method. In addition to analyzing the results, this study suggests that exporters should consider adopting new payment methods, such as blockchain technology-based bills of lading and trade finance platforms, to adapt to the characteristics of the evolving trade and logistics environment. Therefore, exporters should continue to show interest in initiatives aimed at digitizing trade documents as a response to the challenges posed by bills of lading. In future studies, it is necessary to address the lack of social awareness in Korea by conducting advanced research abroad.

Accuracy of HF radar-derived surface current data in the coastal waters off the Keum River estuary (금강하구 연안역에서 HF radar로 측정한 유속의 정확도)

  • Lee, S.H.;Moon, H.B.;Baek, H.Y.;Kim, C.S.;Son, Y.T.;Kwon, H.K.;Choi, B.J.
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.1
    • /
    • pp.42-55
    • /
    • 2008
  • To evaluate the accuracy of currents measured by HF radar in the coastal sea off Keum River estuary, we compared the facing radial vectors of two HF radars, and HF radar-derived currents with in-situ measurement currents. Principal component analysis was used to extract regression line and RMS deviation in the comparison. When two facing radar's radial vectors at the mid-point of baseline are compared, RMS deviation is 4.4 cm/s in winter and 5.4 cm/s in summer. When GDOP(Geometric Dilution of Precision) effect is corrected from the RMS deviations that is analyzed from the comparison between HF radar-derived and current-metermeasured currents, the error of velocity combined by HF radar-derived current is less than 5.1 cm/s in the stations having moderate GDOP values. These two results obtained from different method suggest that the lower limit of HF radar-derived current's accuracy is 5.4 cm/s in our study area. As mentioned in previous researches, RMS deviations become large in the stations located near the islands and increase as a function of mean distance from the radar site due to decrease of signal-to-noise level and the intersect angle of radial vectors. We found that an uncertain error bound of HF radar-derived current can be produced from the separation process of RMS deviations using GDOP value if GDOP value for each component is very close and RMS deviations obtained from current component comparison are also close. When the current measured in the stations having moderate GDOP values is separated into tidal and subtidal current, characteristics of tidal current ellipses analyzed from HF radar-derived current show a good agreement with those from current-meter-measured current, and time variation of subtidal current showed a response reflecting physical process driven by wind and density field.

The Results of Hyperfractionated Radiotherapy on Locally Advanced Non-Small Cell Lung Cancer (국소적으로 진행된 비소세포 폐암에 대한 과분할 방사선 치료의 성적)

  • Hur, Won-Joo;Lee, Hyung-Sik;Kim, Jeong-Ki;Choi, Young-Min;Lee, Ho-Jun;Youn-Seon-Min;Kim, Jae-seok;Kim, Hyo-Jin;Woo-Jong-Soo;Choi, Pill-Jo;Lee, Ki-Nam
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.275-282
    • /
    • 1998
  • Purpose : The effect of hyperfractionated radiotherapy on locally advanced non-small lung cancer was studied by a retrospective analysis. Materials & Methods : We analyzed sixty one patients of biopsy-confirmed, IIIA and IIIB non-small cell lung cancer. Using the ECOG performance scale, all the patients were scored less than 2. They were treated by curative hyperfractionated radiotherapy alone from Oct. 1992 to Oct. 1995 at the Department of Radiation Oncology. All the patients received 120cGy b.i.d with more than 6 hours interval between each fraction. The total dose of radiation was reached up to 6400-7080 cGy with a mean dose of 6934 cGy. The results were analyzed retrospectively. Results : The overall survival rate was 53 1$\%$ in 1 year, 9.9$\%$ in 2 years with a median survival time (MST) of 13.9 months. The progression free survival (PFS) rate was 37.0$\%$ in 1 year, 8.9$\%$ in 2 years. Twenty two Patients were classified as complete responders to this treatment and their MST was 19.5 months When this was compared with that of partial responders (MST: 11 7months), it was statistically significant (p=0.0003). Twenty nine patients of stage IIIA showed a better overall survival rate (1yr 63.3$\%$, 2yr 16.8$\%$) than IIIB patients (1yr 43.3$\%$, 2yr 3.6$\%$), which was also statistically significant (p=0.003). Patients with adenocarcinoma showed a better survival rate (1yr 64.3$\%$, 2yr 21.4$\%$) than that of squamous cell counterpart (1yr 49.4$\%$, 2yr 7.4$\%$), although this was not significant statistically (p=0.61). Two patients developed fatal radiation-induced pneumonia right after the completion of the treatment which progressed rapidly and they all died within 2 months. One patient developed radiation-induced fibrosis after 13 months. He refused further treatment and died soon after the development of fibrosis. Conclusion : Among locally advanced NSCLC, hyperfractionated radiotherapy was effective on stage IIIA patients by increasing MST with acceptable toxicities. Acute radiation-induced pneumonia should be carefully monitored and must be avoided during or after this treatment.

  • PDF

Job importance, job performance, and job satisfaction in dietitians at geriatric hospitals or elderly healthcare facilities in Jeju (제주지역 요양 (병)원 영양사의 직무중요도, 직무수행도 및 직무만족도 분석)

  • Kang, Hye-Sook;Lee, Yunkyoung;Chae, In-Sook
    • Journal of Nutrition and Health
    • /
    • v.49 no.3
    • /
    • pp.189-200
    • /
    • 2016
  • Purpose: This study analyzed job importance, job performance, and job satisfaction in 38 dietitians working at geriatric hospitals and elderly healthcare facilities in Jeju surveyed from September 15-24, 2014 with the aim of providing basic data for improving the quality of meals and nutrition management for elderly patients. Methods: Data were analyzed using descriptive analysis, ${\chi}^2$-test, t-test, ANOVA, and Pearson's correlation coefficients using the SPSS Win program (version 12.0). Results: Regarding job importance, the average score was 4.29 (out of 5), indicating that hygiene and safety management scored the highest at 4.77 (out of 5), and nutrition management scored the lowest at3.86. In terms of job performance of subjects, the average score was 2.87 (out of 5), indicating that cooking operation management scored the highest at 4.42 (out of 5). Regarding the Importance-Performance Analysis (IPA) of job importance and job performance, hygiene and safety management and cooking operation management scored high for importance and performance (B quadrant) menu management, human resource management, and nutrition management scored low for importance and performance (C quadrant) and purchasing management and financial management were included inD quadrant and A quadrant, respectively. For the level of job satisfaction of subjects, the average score was 3.37 (out of 5), indicating that relationships with colleagues scored the highest at 3.72, and improving professionalism scored the lowest at 2.95. Additionally, job importance and performance of subjects were positively correlated withjob satisfaction (r = 0.395, r = 0.386, both p < 0.05). Conclusion: In conclusion, scores for job importance and job performance of nutrition management were low, and job satisfaction of improving professionalism scored low. Therefore, continuous training and education programs of nutrition management should be provided to improve professionalism of dietitians at geriatric hospitals and elderly healthcare facilities.

The analysis of physical features and affective words on facial types of Korean females in twenties (얼굴의 물리적 특징 분석 및 얼굴 관련 감성 어휘 분석 - 20대 한국인 여성 얼굴을 대상으로 -)

  • 박수진;한재현;정찬섭
    • Korean Journal of Cognitive Science
    • /
    • v.13 no.3
    • /
    • pp.1-10
    • /
    • 2002
  • This study was performed to analyze the physical attributes of the faces and affective words on the fares. For analyzing physical attributes inside of a face, 36 facial features were selected and almost of them were the lengths or distance values. For analyzing facial contour 14 points were selected and the lengths from nose-end to them were measured. The values of these features except ratio values normalized by facial vortical length or facial horizontal length because the face size of each person is different. The principal component analysis (PCA) was performed and four major factors were extracted: 'facial contour' component, 'vortical length of eye' component, 'facial width' component, 'eyebrow region' component. We supposed the five-dimensional imaginary space of faces using factor scores of PCA, and selected representative faces evenly in this space. On the other hand, the affective words on faces were collected from magazines and through surveys. The factor analysis and multidimensional scaling method were performed and two orthogonal dimensions for the affections on faces were suggested: babyish-mature and sharp-soft.

  • PDF

Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period (호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증)

  • Jeon, Soo Dong;Bae, Sun Myung;Yoon, In Ha;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the patient's breathing cycle in Gated Volumetric Modulated Arc Therapy Materials and Methods : TrueBeam STxTM(Varian Medical System, Palo Alto, CA) was used in this experiment. The Computed tomography(CT) images that were acquired with RANDO Phantom(Alderson Research Laboratories Inc. Stamford. CT, USA), using Computerized treatment planning system(Eclipse 10.0, Varian, USA), were used to create VMAT plans using 10MV FFF with 1500 cGy/fx (case 1, 2, 3) and 220 cGy/fx(case 4, 5, 6) of doserate of 1200 MU/min. The regular respiratory period of 1.5, 2.5, 3.5 and 4.5 sec and the patients respiratory period of 2.2 and 3.5 sec were reproduced with the $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc), and it was set up to deliver radiation at the phase mode between the ranges of 30 to 70%. The results were measured at respective respiratory conditions by a 2-Dimensional ion chamber array detector(I'mRT Matrixx, IBA Dosimetry, Germany) and a MultiCube Phantom(IBA Dosimetry, Germany), and the Gamma pass rate(3 mm, 3%) were compared by the IMRT analysis program(OmniPro I'mRT system software Version 1.7b, IBA Dosimetry, Germany) Results : The gamma pass rates of Case 1, 2, 3, 4, 5 and 6 were the results of 100.0, 97.6, 98.1, 96.3, 93.0, 94.8% at a regular respiratory period of 1.5 sec and 98.8, 99.5, 97.5, 99.5, 98.3, 99.6% at 2.5 sec, 99.6, 96.6, 97.5, 99.2, 97.8, 99.1% at 3.5 sec and 99.4, 96.3, 97.2, 99.0, 98.0, 99.3% at 4.5 sec, respectively. When a patient's respiration was reproduced, 97.7, 95.4, 96.2, 98.9, 96.2, 98.4% at average respiratory period of 2.2 sec, and 97.3, 97.5, 96.8, 100.0, 99.3, 99.8% at 3.5 sec, respectively. Conclusion : The experiment showed clinically reliable results of a Gamma pass rate of 95% or more when 2.5 sec or more of a regular breathing period and the patient's breathing were reproduced. While it showed the results of 93.0% and 94.8% at a regular breathing period of 1.5 sec of Case 5 and 6, it could be confirmed that the accurate dose delivery could be possible on the most respiratory conditions because based on the results of 100 patients's respiratory period analysis as no one sustained a respiration of 1.5 sec. But, pretreatment dose verification should be precede because we can't exclude the possibility of error occurrence due to extremely short respiratory period, also a training at the simulation and careful monitoring are necessary for a patient to maintain stable breathing. Consequently, more reliable and accurate treatments can be administered.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.