Seismic performance of exterior R/C beam-column joint under varying axial force

  • Hu, Yanbing;Maeda, Masaki;Suzuki, Yusuke;Jin, Kiwoong
    • Structural Engineering and Mechanics
    • /
    • 제78권5호
    • /
    • pp.623-635
    • /
    • 2021
  • Previous studies have suggested the maximum experimental story shear force of beam-column joint frame does not reach its theoretical value due to beam-column joint failure when the column-to-beam moment capacity ratio was close to 1.0. It was also pointed out that under a certain amount of axial force, an axial collapse and a sudden decrease of lateral load-carrying capacity may occur at the joint. Although increasing joint transverse reinforcement could improve the lateral load-carrying capacity and axial load-carrying capacity of beam-column joint frame, the conditions considering varying axial force were still not well investigated. For this purpose, 7 full-scale specimens with no-axial force and 14 half-scale specimens with varying axial force are designed and subjected to static loading tests. Comparing the experimental results of the two types of specimens, it has indicated that introducing the varying axial force leads to a reduction of the required joint transverse reinforcement ratio which can avoid the beam-column joint failure. For specimens with varying axial force, to prevent beam-column joint failure and axial collapse, the lower limit of joint transverse reinforcement ratio is acquired when given a column-to-beam moment capacity ratio.

콘크리트 충전강관 기둥과 PC 철근 콘크리트 보 접합부의 개발에 관한 연구(2) -콘크리트 강도, 판넬죤의 크기, 축력비를 변수로 한 접합부의 거동 특성- (A Study on Development for Joint of Concrete Filled Steel Tube Column and P.C Reinforced Concrete Beam(2) -The Behaviors Properties of Joint with Key Parameter, such as Strength of Concrete, size of Panel Zone and Axial Force ratio-)

  • 박정민;이승조;김화중
    • 한국강구조학회 논문집
    • /
    • 제9권1호통권30호
    • /
    • pp.107-120
    • /
    • 1997
  • The purpose of this study is to develop composite structural system which is to have versatility in plan design and to improve economical efficieney, to maximise structural capacity than existing structural system. In this viewpoint, it was investigated to the properties of structural behaviors for i oint consisting of concrete filled steel square tube column and P.C reinforced concrete beam through a series of hysteretic behavior experiment. In the previous report, researched to the properties of joints with key parameters. such as Axial Force ratio and section types. From the based on previous results, this study investigated the properties of this joints with key parameters, such as strength of concrete, size of panel zone and Axial Force ratio. The obtained results are summarised as follows. (1) Investigating for the failure mode of the beam-to-column joint, the specimens of S,LL and LH series(except for L5H) presented flexural failure mode. (2) The initial stiffness of joint was increasd as the decrease of axial force ratio and increase of the concrete strength. (3) The rotation resisting capacity was effective as the increment of the concrete strength and decrement of the axial force ratio. (4) The emprical formula to predict the ultimate capacity of joint model to introduce decrease coefficient according to the axial force ratio to superimpose shearing strength of steel web(H section) and bending strength of reinforced concrete beam was expected.

  • PDF

Shear behavior of exposed column base connections

  • Cui, Yao
    • Steel and Composite Structures
    • /
    • 제21권2호
    • /
    • pp.357-371
    • /
    • 2016
  • Column base connections are critical components in steel structures because they transfer axial forces, shear forces and moments to the foundation. Exposed column bases are quite commonly used in low- to medium-rise buildings. To investigate shear transfer in exposed column base plates, four large scale specimens were subjected to a combination of axial load (compression or tension) and lateral shear deformations. The main parameters examined experimentally include the number of anchor rod, arrangement of anchor rod, type of lateral loading, and axial force ratio. It is observed that the shear resisting mechanism of exposed column base changed as the axial force changed. When the axial force is in compression, the resisting mechanism is rotation type, and the shear force will be resisted by friction force between base plate and mortar layer. The specimens could sustain inelastic deformation with minimal strength deterioration up to column rotation angle of 3%. The moment resistance and energy dissipation will be increased as the number of anchor rods increased. Moreover, moment resistance could be further increased if the anchor rods were arranged in details. When the axial force is in tension, the resisting mechanism is slip type, and the shear force will be resisted by the anchor rods. And the shear resistance was reduced significantly when the axial force was changed from compression to tension. The test results indicated that the current design approach could estimate the moment resistance within reasonable acceptance, but overestimate the shear resistance of exposed column base.

금속 V-벨트 CVT의 동력전달 특성과 변속비-부하토크-축력 관계 (Power Transmission Characteristics and Speed Ratio-Torque Load-Axial Force Relationship for a Metal V-Belt CVT)

  • 김광원;김현수
    • 대한기계학회논문집
    • /
    • 제14권2호
    • /
    • pp.349-357
    • /
    • 1990
  • Power transmission characteristics and speed ratio-torque load-axial force relationship for a metal V-belt CVT were investigated theoretically and experimentally. In the metal V-belt CVT drive, it was found that the power was transmitted by thrust force and that band tension should be greater than compression force between the metal blocks. The experimental results for the speed ratio-torque load-axial force relationship showed good agreement with those predicted using equations developed from theoretical considerations.

차량용 고무 및 금속 V-벨트 CVT의 변속비-부하토크-축력특성과 성능비교 (Comparison of speed ratio-torque load-axial force characteristics and their performance for automotive rubber and metal V-belt CVT)

  • 김현수;김광원
    • 오토저널
    • /
    • 제12권3호
    • /
    • pp.9-20
    • /
    • 1990
  • The speed ratio-torque load-axial force characteristics of a rubber V-belt (RVB) and a metal V-belt (MVB) CVT are investigated and their performances are compared. It is found that power is transmitted by tension difference in RVB, and by thrust difference in MVB. The nondimensional equations for speed ratio-torque load-axial force of RVB are exactly same as those of MVB. However, actual characteristics of axial forces of RVB and MVB are different depending on their power transmission methods. The torque capacity of MVB is 5-6 times higher than that of RVB due to MVB's higher strength, even if the required axial force of MVB CVT control is 3-4 times higher than that of RVB.

  • PDF

화재시 축력비에 따른 매입형 합성기둥의 내화성능에 대한 해석적 연구 (An Analytical Study on Encased Steel Composite Columns Fire Resistance According to Axial Force Ratio)

  • 김예솜;최병정
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권1호
    • /
    • pp.97-107
    • /
    • 2020
  • 본 연구에서는 화재시 매입형 합성기둥의 높은 축력비에 따른 내화성능을 알아보기 위해 유한요소해석 프로그램(ANSYS)을 통한 해석을 실시하였다. 온도에 따른 응력-변형률 곡선을 적용하여 ASTM E 119 가열곡선과 축력비 0.7, 0.6, 0.5에 따른 과도상태 열전달해석 및 정적구조해석을 실시하였으며, 해석조건과 동일한 조건에서의 재하가열실험을 실시하였다. 또한, 기준식(Eurocode 4)에 따라 가열시간에 따른 합성기둥의 공칭압축강도를 산정하고, 축력비로 나타내어 해석값 및 실험값과 비교하였다. 해석 및 실험과 기준(Eurocode 4)을 통해 가열시간에 따른 단면별 온도분포를 확인하고, 이에 따른 내화성능을 측정해 비교분석하였다. 유한요소해석 결과 축력비 0.5에서는 내화시간 180분으로 실험값과 유사한 값이 도출된 반면, 축력비 0.6, 0.7에서 내화시간 150분과 60분이 도출되어 실험결과에 비해 다소 높은 결과가 도출된 것을 알 수 있었다. 그리고 기준식(Eurocode 4)에 따라 산정한 축력비에 따른 내화시간이 실제 실험값에 비해 다소 낮게 평가하고 있다는 것을 확인하였다. 그러나 축력비 0.7에서는 기준(Eurocode 4)이 실험값에 비해 다소 높게 평가하는 것을 확인하였다. 이에 따라 고축력에서의 매입형 합성기둥의 내화특성(시간-축력비 관계)을 확인하고, 도출된 매입형 합성기둥의 실험 및 해석데이터를 Eurocode기준의 검증의 자료로 활용할 수 있을 것으로 보인다.

변환각 트러스 모델에 의한 축력을 받는 철근콘크리트 부재의 전단강도 예측 (Shear Strength Prediction of Reinforced Concrete Members Subjected In Axial force using Transformation Angle Truss Model)

  • 김상우;이정윤
    • 콘크리트학회논문집
    • /
    • 제16권6호
    • /
    • pp.813-822
    • /
    • 2004
  • 축하중을 받는 철근콘크리트 부재의 전단강도를 예측하기 위하여, 본 연구에서는 전단력과 축하중 및 휨모멘트를 받는 철근 콘크리트 부재의 전단거동을 예측할 수 있는 변환각 트러스 모델(TATM)을 제안하였다. TATM에서, 축력의 영향을 고려하기 위하여 축압축력이 증가할수록 고정각은 감소하며 균열 방향의 콘크리트 전단저항은 증가한다. TATM의 예측결과가 축력을 받는 철근콘크리트 부재에 대하여 정확성과 신뢰성을 가지는지 검증하기 위하여, 축력을 받는 총 67개의 전단실험 결과를 수집하였으며, TATM 및 기존의 트러스 모델(MCFT, RA-STM FA-STM)과 비교하였다. 수집한 실험결과와 해석결과를 비교한 결과, TATM에 의한 해석결과는 실험결과를 평균 0.95, 변동계수 $12.0\%$로 기존의 트러스 모델보다 더 정확히 예측하였으며, 철근능력비, 축력, 전단경간비 및 압축철근비의 영향을 받지 않았다.

Exposed Reinforced Concrete-Filled Steel Tubular (RCFST) column-base joint with high-strength

  • Mou, Ben;Wang, Zian;Qiao, Qiyun;Zhou, Wanqiu
    • Steel and Composite Structures
    • /
    • 제44권1호
    • /
    • pp.1-15
    • /
    • 2022
  • The weld quality has always been an important factor affecting the development of exposed CFT column-base joint. In this paper, a new type of exposed RCFST column-base joint is proposed, in which the high strength steel bars (USD 685) are set through the column and reinforced concrete foundation without any base plate and anchor bolts. Three specimens, the varying axial force ratio (0, 0.25 and 0.5), were tested under cyclic loadings. In addition, the bending moment capacity, energy dissipation capacity and deformation capacity of column-base joints were clarified. The experimental results indicated that the axial force ratio increases the stiffness and the bending moment and improves the energy dissipation capacity of column-base joints. This is because a large axial force can limit the slip between steel tubular and infilled concrete effectively. The specimens show stable hysteresis behavior.

Experimental study on fire performance of axially-restrained NSC and HSC columns

  • Wu, Bo;Li, Yi-Hai
    • Structural Engineering and Mechanics
    • /
    • 제32권5호
    • /
    • pp.635-648
    • /
    • 2009
  • This paper describes fire performance of eight axially restrained reinforced concrete (RC) columns under a combination of two different load ratios and two different axial restraint ratios. The eight RC columns were all concentrically loaded and subjected to ISO834 standard fire on all sides. Axial restraints were imposed at the top of the columns to simulate the restraining effect of the rest of the whole frame. The axial restraint was effective when the column was expanding as well as contracting. As the results of the experiments have shown, the stiffness of the axial restraint and load level play an important role in the fire behaviors of both HSC and NSC columns. It is found that (a) the maximum deformations during expanding phase were influenced mostly by load ratio and hardly by axial restraint ratio, (b) For a given load ratio, axial restraint ratio had a great impact on the development of axial deformation during contraction phase beyond the initial equilibrium state, (c) increasing the axial restraint increased the value of restraint force generated in both the NSC and HSC columns, and (d) the development of column axial force during the contracting and cooling phase followed nearly parallel trend for columns under the same load ratio.