• 제목/요약/키워드: Axial Data

검색결과 1,059건 처리시간 0.026초

Solution to Slow Down Myopia Progression

  • Jung, Ji-Won
    • 한국임상보건과학회지
    • /
    • 제8권1호
    • /
    • pp.1386-1397
    • /
    • 2020
  • Purpose: To examine the effectiveness of various treatments; bifocal spectacles, orthokeratology, atropine, and time spent in outdoors; in slowing down the myopia progression for Asian adolescents (6-18age). Methods: The research focused on examining the most effective treatment in controlling myopia based on the literature sources that have been published. Through meta-analysis of various research papers that already has been done in this field, a lot of data was collected. For each treatment, the difference in axial length and spherical equivalent over time was measured and recorded. To quantitatively record the difference, both axial length and spherical equivalent was determined by value of control group value of treatment group. The paper compared the effectiveness of each treatment based on the data that was measured. Results: Adolescents who chose to spend time outdoors in order to slow down myopia progression had axial length difference of 0.03 mm and spherical equivalent difference of 0.17 D. Adolescents that used atropine had axial length difference of 0.36 mm and spherical equivalent difference of 0.92 D. Bifocal spectacle resulted in axial length difference of 0.21 mm and spherical equivalent difference of 0.59 D, and for orthokeratology 0.23 mm and 0.04 D, respectively. Axial length wise, myopia was most controlled by the atropine since there was a greatest difference between the group that got the treatment and the group that did not have the treatment. According to the spherical equivalent difference data, myopia was most controlled by atropine. Conclusion: Atropine showed the most effective result in controlling myopia among the four treatment. Again, compared to other three treatment, using atropine appeared to have greatest ability in slowing down myopia progression since adolescents who were treated with atropine had greatest difference from adolescents in the control group that had the same condition but didn't get the treatment. However, every treatment was only used for 2 or 3 years which is quite short time period to measure the long term effect of the four treatments. Also, since atropine is a pharmaceutical method to control myopia, it may harm adolescents' eyes compared to optical or environmental treatment.

두경부 전산화 단층촬영시의 주요 장기선량, 유효선량 및 위험도 (ORGAN DOSE, EFFECTIVE DOSE AND RISK ASSESSMENT FROM COMPUTED TOMOGRAPHY TO HEAD AND NECK REGION)

  • 김애지;조봉혜;나경수
    • 치과방사선
    • /
    • 제25권1호
    • /
    • pp.27-38
    • /
    • 1995
  • The organ or tissue doses were determined with head and neck phantom measurement for multiple axial scans (36 slices), multiple coronal scans (13 slices), 3 types of single axial scans(orbit, maxillary sinus and mandibular canal) and single coronal scan (maxillary sinus). For each scan sequence 30 TLDs were placed in selected sites(16 internal sites and 14 external sites) in a tissue-equivalent phantom. The exposure was made at 120kVp, 500mAs with 5 mm slice width. The results were as follows : 1. In multiple axial scans, the greatest effective dose recorded was that delivered to the thyroid glands(2.77 mSv) and the least was that received by the skin(0.05 mSv). From these data, stochastic effects were 202.2x10/sup -6/ and 3.7×10/sup -6/, respectively. 2. In multiple coronal scans, the greatest effective dose recorded was that delivered to the salivary glands(0.58 mSv) and the least was that received by the skin(0.01 mSv). From these data, stochastic effects were 42.2×10/sup -6/ and 0.7×10/sup -6/, repectively. 3. Among single axial scans, the greatest effective dose recorded was that delivered to the salivary gland(0.38 mSv) in maxillary sinus scan. From this data, stochastic effect was 27.7×10/sup -6/. 4. In single coronal scan, the greatest effective dose recorded was that delivered to the salivary gland(0.01 mSv). From this data, stochastic effect was 1.0×10/sup -6/. 5. The equivalent dose measured that delivered to the lens of the eyes was 69.64 mSv in multiple axial scan, 39.32 mSv in multiple coronal scan and 36.77 mSv in single axial scan(orbit).

  • PDF

수직증축 공동주택 하부 기존말뚝의 열화를 고려한 축강성 제안 (Proposed Deterioration-induced Axial Stiffness of Existing Piles in Vertical Extension Structures)

  • 정상섬;김도현;조현철
    • 한국지반공학회논문집
    • /
    • 제35권12호
    • /
    • pp.25-33
    • /
    • 2019
  • 본 연구에서는 수직증축 구조물의 기존말뚝의 축강성(Kve)을 이론적인 접근과 현장 계측 결과를 바탕으로 추정하였다. 이론적인 접근에는 Randolph와 Wroth(1978)가 제안한 축강성 공식을 적용하여, 지중에 설치된 강성 및 연성말뚝의 세장비(L/D)에 따른 축강성의 범위를 도출하였다. 여기에, 1995 - 1997년 사이에 설치된 38본 말뚝의 계측된 시공 당시 축강성을 이론적으로 도출한 축강성 범위에 중첩해서 고려하였다. 이를 통하여, 노후화와 열화에 의하여 감소한 기존말뚝의 축강성의 최대값을 세장비에 따라 제안하였고, 도출된 값을 통계적인 기법을 통하여 상위 95% 값을 제안하여 신설 보강말뚝 설계 시 필요한 최소 축강성(Kvr)을 산정하는 데에 활용할 수 있도록 하였다.

국내도로 주행 시험을 통한 6축 진동시험 방법에 관한 연구 (MAST Vibration on MAST System with Field Data)

  • 김찬중;배철용;이봉현;권성진;나병철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.764-769
    • /
    • 2006
  • Vibration test on MAST(multi axial simulation table) system has several advantage over one-axial vibration test that could simulate 6-DOF, 3-axial translation and 3-axial moment, at the same time. Since field vibration motion can be fully represented with 6-DOF, multi-axial vibration test on vehicle component is widely conducted in technical leading companies to make sure its fatigue performance in vibration environment. On the way to fulfill the process, editing technique of obtained field data is key issue to success a reliable vibration testing with MAST system. Since the original signals are not only too large to fulfill it directly, but all of the measured data is not guarantee its convergency on generating its driving files, editing technique of the original signals are highly required to make some events that should meet the equal fatigue damage on the target component In this paper, key technique on editing a field data feasible for MAST system is described based on energy method in vibration fatigue. To explain its technique explicitly, author first introduced a process on field data acquisition of two vehicle component and then, representing events are produced to keep up with the editing strategy about a energy method. In the final chapter, a time information regarding a vibration test on MAST system is derived from the energy data which is critical information to perform a vibration test.

  • PDF

Validity assessment of aspect ratios based on Timoshenko-beam model: Structural design

  • Emad Ghandourah;Muzamal Hussain;Mohamed A. Khadimallah;Mashhour Alazwari;Mohamed R. Ali;Mohammed A. Hefni
    • Computers and Concrete
    • /
    • 제31권1호
    • /
    • pp.1-7
    • /
    • 2023
  • In this paper, Timoshenko-beam model is developed for the vibration of double carbon nanotubes. The resulting frequencies are gained for axial wave mode and length-to-diameter ratios. The natural frequency becomes more prominent for lower length-to-diameter ratios and diminished for higher ratios. The converse behavior is observed for axial wave mode with clamped-clamped and clamped-free boundary conditions. The frequencies of clamped-free are lower than that of clamped-clamped boundary condition. The eigen solution is obtained to extract the frequencies of double walled carbon nanotubes using Galerkin's method through axial deformation function. Computer softer MATLAB is used for formation of frequency values. The frequency data is compared with available literature and found to be in agreement.

공기조화기 축류팬의 공력소음 특성 연구 (The Study on the Aeroacoustic Characteristics of an Axial Fan for an Air-Conditioner)

  • 이수영;한재오;김태헌;이재권;전완호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.205-208
    • /
    • 2006
  • This paper proposes a new computational aeroacoustics method for an axial fan analysis. The major aeroacoustic noise source of an outdoor air-conditioner is the axial fan. It was revealed that the dominant noise source is the aerodynamic interactions between the rotating blade and stationary orifice. Many researches were focused on the fan only case. However, it does not fit to a real outdoor unit of air-conditioner. Especially, the inlet part of the axial fan of real system case is complex and not uniform. So, in order to identify the dominant noise source of axial fan, full outdoor unit analysis is important. Transient CFD analysis of full system was performed by commercial CFD code - SC/Tetra. Dominant noise source of the system was calculated by commercial CFN code - FlowNoise. The results show that not only BPF peaks but also broadband noise are similar to the measured data.

  • PDF

Axial behavior of steel-jacketed concrete columns

  • Rupp, J.;Sezen, H.;Chaturvedi, S.
    • Steel and Composite Structures
    • /
    • 제16권1호
    • /
    • pp.59-75
    • /
    • 2014
  • A new concrete confinement model is developed to predict the axial load versus displacement behavior of circular columns under concentric axial load. The new confinement model is proposed for concrete filled steel tube columns as well as circular reinforced concrete columns with steel tube jacketing. Existing confinement models were evaluated and improved using available experimental data from different sets of columns tested under similar loading conditions. The proposed model is based on commonly used confinement models with an emphasis on modifying the effective confining pressure coefficient utilizing the strength of the unconfined concrete and the steel tube, the length of the column, and the thickness of the steel tube. The proposed model predicts the ultimate axial strength and the corresponding strain with an acceptable degree of accuracy while also highlighting the importance of the manner in which the steel tube is used.

GIS 도로 데이터의 일반화를 이용한 Axial map 구현 방법에 관한 연구 (Axial map Implementation Using Linear Generalization of GIS data)

  • 권순일;박수홍;주용진
    • Spatial Information Research
    • /
    • 제18권4호
    • /
    • pp.99-108
    • /
    • 2010
  • 방향전환의 횟수를 변인으로 공간구조를 정량적으로 산출하고 분석 할 수 있는 Space Syntax 방법론은 안전한 길, 활기 있는 길 등 연간의 '심리적 거리' 특성을 반영 할 수 있어 기존의 GIS 기반 공간정보 서비스에서의 '물리적 최단 거리'에 기반 한 공간정보 서비스에 교통사고 및 야간의 범죄로부터의 안전성 등을 훨씬 중시하는 결과를 보여줄 수 있다. 이처럼 Space Syntax 방법론을 이용한 방법을 위해 기본적으로 Axial map(축선도)을 구축해 작업하여야 하는데, 실제 축선도를 구현하는데 시간적, 물리적 제한을 많이 갖게 된다. 따라서 본 연구에서는 GIS 도로 데이터를 이용하여 축선도를 구현하는데 있어, 선행 사상의 일반화 원리를 이용하여 전통적인 축선도를 구축함에 있어 객관적인 근거를 바탕으로 알아보고, Space Syntax의 주요인자인 전체통합도와 실제 통행량 사이의 상관관계를 통해 결과를 비교하여 본다. 이러한 방법을 통하여 실제 통행량과 $R^2$=0.5387 수준까지의 상관관계의 결과를 얻을 수 있었다.

차량 로드 휠의 복합축 평가 프로세스 구축을 통한 내구신뢰성 강건화 및 주행안정성 향상 (Improvement of Durability and Reliability by Developing a Bi-axial Test Process of Road Wheel)

  • 정수식;유연상;김대성
    • 자동차안전학회지
    • /
    • 제8권1호
    • /
    • pp.26-30
    • /
    • 2016
  • The steel road wheel on ventilation holes was cracked in the vehicle durability test. But the component durability test by uni-axial, CFT(Cornering Fatigue Test) and RFT(Radial Fatigue Test) had been satisfied. That is, the uni-axial component test could not forecast the crack of vehicle. Therefore this study developed the bi-axial test mode to reflect a vehicle condition(to reflect both vertical and lateral force simultaneously) based on real load data which was measured in Europe and China and developed CAE simulation too. It reproduced the cracks same as vehicle's and verified by bi-axial test machine in the LBF(Fraunhofer Institute for Structural Durability and System Reliability) durability research center in Germany. Finally this the durability CAE simulation by using HMC(Hyundai Motor Company)'s the bi-axial test mode predicts feasibly the steel wheel's durability performance before vehicle durability test.

평균반경해석법을 이용한 축류압축기 성능해석 프로그램 개발 (Development of Performance Analysis Program for an Axial Compressor with Meanline Analysis)

  • 박준영;박무룡;최범석;송재욱
    • 대한기계학회논문집B
    • /
    • 제33권2호
    • /
    • pp.141-148
    • /
    • 2009
  • Axial-flow compressor is one of the most important parts of gas turbine units with axial turbine and combustor. Therefore, precise prediction of performance is very important for development of new compressor or modification of existing one. Meanline analysis is a simple, fast and powerful method for performance prediction of axial-flow compressors with different geometries. So, Meanline analysis is frequently used in preliminary design stage and performance analysis for given geometry data. Much correlations for meanline analysis have been developed theoretically and experimentally for estimating various types of losses and flow deviation angle for long time. In present study, meanline analysis program was developed to estimate compressor losses, incidence angles, deviation angles, stall and surge conditions with many correlations. Performance prediction of one stage axial compressors is conducted with this meanline analysis program. The comparison between experimental and numerical results show a good agreement. This meanline analysis program can be used for various types of single stage axial-flow compressors with different geometries, as well as multistage axial-flow compressors.