• Title/Summary/Keyword: Average of Floor

Search Result 378, Processing Time 0.032 seconds

Effects of Water Restriction on the Growth Performance, Carcass Characteristics and Organ Weights of Naked Neck and Ovambo Chickens of Southern Africa

  • Chikumba, N.;Chimonyo, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.7
    • /
    • pp.974-980
    • /
    • 2014
  • In semi-arid areas of Southern Africa, dehydration can compromise the performance and welfare of local chickens, particularly during the growing period when confinement is curtailed and birds are left to scavenge for feed and water. The effect of water restriction on the growth performance was compared in Naked Neck (NNK) and Ovambo (OVB) chickens that are predominant in Southern Africa. A total of 54 eight-wk-old pullets each of NNK and OVB chickens with an initial average weight of $641{\pm}10g/bird$ were randomly assigned to three water intake treatments, each having six birds for 8 wk. The water restriction treatments were ad libitum, 70% of ad libitum and 40% of ad libitum intake. Nine experimental pens with a floor space of $3.3m^2$ per strain were used. The pens were housed in an open-sided house with cement floor deep littered with a 20 cm layer of untreated wood shavings. Feed was provided ad libitum. Average daily water intake (ADWI), BW at 16 weeks of age (FBW), ADG, ADFI, feed conversion ratio (FCR) and water to feed ratios (WFR) were determined. Ovambo chickens had superior (p<0.05) FBW, ADG and ADWI than NNK chickens. Body weight of birds at 16 weeks of age, ADG, ADFI, ADWI, and WFR declined progressively (p<0.05) with increasing severity of water restriction while FCR values increased (p<0.05) as the severity of water restriction increased. Naked Neck chickens had better FCR at the 40% of ad libitum water intake level than Ovambo chickens. The dressing percentage per bird was higher in water restricted birds than those on ad libitum water consumption, irrespective of strain. Heart weight was significantly lower in birds on 40% of ad libitum water intake than those on ad libitum and 70% of ad libitum water intake, respectively. In conclusion, NNK chickens performed better than OVB chickens under conditions of water restriction and would be ideal to raise for meat and egg production in locations where water shortages are a major challenge.

Effects of Mannan-oligosaccharides and Live Yeast in Diets on the Carcass, Cut Yields, Meat Composition and Colour of Finishing Turkeys

  • Konca, Yusuf;Kirkpinar, Figen;Mert, Selim
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.22 no.4
    • /
    • pp.550-556
    • /
    • 2009
  • This study was designed to evaluate the effects of dietary prebiotic (mannan oligosaccharide = MOS) and probiotic (Saccharomyces cerevisiae = SC) in finishing turkey diets on carcass, cut yield, meat composition and colour. A total of 72 ten-weeksold Big6 male turkey poults were used in the trial. There were eight replicate floor pens per floor with three birds in each. The experiment lasted up to 20 wks of age. The trial was set up as a completely randomized design with 3 dietary treatments. The treatments were: i) negative control (C, no additive); ii) MOS 1 g per kg of diet and iii) SC 1 g per kg of diet (strain SC47, $300{\times}10^{10}$ CFU/kg). Body weight (BW) and feed intake were determined for each of the two week intervals. Twenty-four birds were slaughtered and eviscerated to determine carcass, carcass parts and internal organ weights at 20 wks of age. Meat colour and pH levels were measured 24 h after slaughter. The dietary treatments did not affect BW and average daily gain during the trial (p>0.05). The average daily feed intake and feed conversion ratio of turkey toms fed with MOS were higher than those of control and SC groups during the overall period (p<0.05). The dietary treatments did not affect carcass yield, breast meat, thigh, wing, liver, heart, empty gizzard, intestine, and abdominal fat pad proportions and meat pH, composition and pigmentation (p>0.05). These results suggest that the addition of MOS and SC is not likely to produce any performance or carcass characteristics in finishing turkeys at 10 to 20 wks of age.

The Field Measurement of Airtightness in the Apartment Buildings (신축공동주택의 기밀성능 실측에 관한 연구)

  • Park, Won seok;Yoon, Jae Ock
    • KIEAE Journal
    • /
    • v.3 no.3
    • /
    • pp.43-50
    • /
    • 2003
  • Nowdays the apartment is a main type of modernized residential buildings. According to the improvement of construction techniques and functions of windows and doors, recent apartments are enhanced air tightness of windows, doors and building envelopes. As Infiltration is decreased and natural ventilation is reduced, energy could be saved in winter. However, indoor air quality is bad. The air Infiltration of a building could be enlarged by physical actions, such as building designs, constructions and reduction of air tightness which is caused by aging. This research analyzes and measures with KNS-4000P (Sapporo air tightness measurement) the air tightness of the high rise apartments which is recently constructed and not occupied yet. With depressurization method, the KNS-4000 installed on the window and the indoor air-leakage was measured. At that time, Air come out from the edge of the windows and doors because of the pressure differences between indoor and outdoor. We measure the amount of the air as effective air leakage areas. This method of depressurization takes less time to measure than other methods and is less affected from other conditions. We measured infiltration of total 56 household, 29 households S apartment (total floor area : $64.42m^2$) in Balan and 29 households D apartment(total floor area : $78.21m^2$) in Chonan. As a result of the field measurements at October 2003, normalized leakage area of D apartment in Cheonan was $2.05cm^2/m^2{\sim}3.49cm^2/m^2$ (average: $2.77cm^2/m^2$) and normalized leakage area of S apartment in Balan is $1.23cm^2/m^2{\sim}1.68cm^2/m^2$ (average: $1.5cm^2/m^2$).

Organic Carbon Distribution of the Pinus densiflora Forest on Songgye Valley at Mt. Worak National Park

  • Jeon, In-Yeong;Shin, Chang-Hwan;Kim, Gwang-Hoon;Mun, Hyeong-Tae
    • Journal of Ecology and Environment
    • /
    • v.30 no.1
    • /
    • pp.17-21
    • /
    • 2007
  • The organic carbon (OC) distribution of Pinus densiflora forest in Songgye valley at Mt. Worak National Park were studied as a part of the National Long-Term Ecological Research in Korea. In order to investigate the OC distribution, OC in plant biomass, litterfall, litter layer on forest floor, and soil were estimated. The density of P. densiflora forest was 1,300 trees/ha, average DBH was $15.2{\pm}6.17\;cm$ and average tree height was $10.7{\pm}2.56\;m$. The shrub layer was dominated by shrubby Quercus variabilis, Fraxinus sieboldiana and lndigofera kirilowii with low frequency, and herb layer was dominated by Pteridium aquilinum and Miscanthus sinensis. Total amount of OC stored in this pine forest was 142.78 ton C/ha. Organic carbon stored in soil and plant biomass accounted for 59.2% and 37.8%, respectively. Amount of OC distributed in trees, shrubs, herbs and litter layer in this pine forest was 51.79, 2.03, 0.12 and 4.29 ton C/ha, respectively. Amount of OC returned to forest floor via litterfall was $1.50\;ton\;C\;ha^{-1}\;yr^{-1}$. Soil organic carbon (SOC) decreased along the soil depth. Total amount of SOC within 50cm soil depth was $84.55\;ton\;C\;ha^{-1}\;50\;cm-depth^{-1}$.

A Study on the Characteristics of Area and Spatial Elements Based on the Building Size of Childcare Center (보육시설 평면사례분석을 통한 시설규모별 소요실 및 면적특성 분석)

  • Park, Jung-A;Choi, Mock-Wha;Kim, Young-Aee
    • Journal of the Korean housing association
    • /
    • v.22 no.1
    • /
    • pp.65-73
    • /
    • 2011
  • The purpose of this study is to find out the characteristics of area and spatial elements according to the building size and provide the guidelines for space planning of the child care center. This study used the content analysis method and analysis was made on the floor plans for 51 cases and the floor plans were converted to Autocad drawings to analyze the area. The results of this study were as follows; 1) Child care centers over 70% were single-attached building types which made it possible for creating outdoor environments for children. However, most small-size centers which had under 50 children did not have the facilities for outdoor activities. 2) In terms of spatial elements, the basic spaces of the small-size center were the classroom, bathroom, kitchen, office and reference room. The medium or large size centers had extra rooms for special activities and service spaces in addition to the basic spaces. 3) Classroom area per child was 2.65 m2 on average. Space composition ratio on average for care, staff, and service was programmed by 57%, 9%, 34% respectively. Small-size center had relatively more care space when compared to the others. In the case of large-size centers, there was a tendency that service space was increased, but care space was decreased.

A Study on the Chemical Powdering Process of Polypropylene Resin for Anti-slip Floor Paint (미끄럼 방지 바닥 도료용 폴리프로필렌 수지의 화학적 분쇄에 관한 연구)

  • Kim, D.I.;Chung, H.Y.;Hwang, S.H.;Cho, I.S.;Youn, K.J.;Cho, B.S.;Kim, K.K.;Yun, K.J.
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.78-83
    • /
    • 2012
  • In this study, some experimental results of the peroxide-degradation process of polypropylene(PP) in a co-rotating twin-screw extruder to produce controlled rheology polypropylene(CRPP) are presented. The peroxide was dicumyl peroxide(DCP) and the concentration of DCP was in the range 0-0.3 wt%. It was found that the rheological properties of PP change significantly during reactive extrusion. Melt flow index(MFI) increased with DCP concentration. Intrinsic viscosity decreases with increasing DCP concentration. From dynamic rheological data, number average molecular weight(Mn), weight average molecular weight(Mn) and molecular weight distribution(MWD) were calculated. Results indicated that Mw decreases and MWD becomes narrower with increasing peroxide concentration. Especially, particle size distribution of CRPP decreases with increasing DCP concentration by chemical powdering process, and anti-slip floor paint, CRPP(DCP 0.2 wt%) powder by 10phr was friction coefficient 2.15 ${\mu}$, abrasion resistance 511.18%.

Laboratory Measurement to Provide Threshold of Visibility for Terrestrial 4K-UHDTV Broadcasting based on HEVC over DVB-T2 (HEVC over DVB-T2 기반 지상파 4K-UHDTV 방송을 위한 양시청 기준값 실험실 테스트 결과)

  • Jeon, Sungho;Kim, Sanghoon;Hahm, Sangjin;Yim, Zungkon;Suh, Young-Woo
    • Journal of Broadcast Engineering
    • /
    • v.21 no.4
    • /
    • pp.506-514
    • /
    • 2016
  • In this study, HEVC over DVB-T2 systems with a bandwidth of 6 MHz is considered, particularly for the terrestrial 4K-UHDTV broadcasting service in the Republic of Korea. The threshold of visibility carrier-to-noise power ratio (ToV C/N) and the receiver minimum required input level (sensitivity) for satisfying the subjective picture failure (SPF) condition are measured in the laboratory. It is observed, for transmitting 26.37 Mbps data stream correctly, that ToV C/N is 18.8 dB on average, and the receiver sensitivity is varied from minimum -84.2 dBm to maximum -80.0 dBm. Based on the results, the receiver noise floor is calculated by -100 dBm on average.

Evaluation of adenosine triphosphate testing for on-farm cleanliness monitoring compared to microbiological testing in an empty pig farrowing unit

  • Yi, Seung-Won;Cho, Ara;Kim, Eunju;Oh, Sang-Ik;Roh, Jae Hee;Jung, Young-Hun;Choe, Changyong;Yoo, Jae Gyu;Do, Yoon Jung
    • Journal of Animal Science and Technology
    • /
    • v.62 no.5
    • /
    • pp.682-691
    • /
    • 2020
  • Careful cleaning and disinfection of pigpens is essential to prevent disease spread and avoid the resultant economic losses. Hygiene in pigpens is generally evaluated by visual monitoring supplemented with bacteriological monitoring, which includes counting the total aerobic bacteria (TAB) and/or fecal indicator bacteria (FIB). However, these methods present drawbacks such as time and labor requirements. As adenosine triphosphate (ATP) is ubiquitous in all living organisms including microorganisms, this study aimed to directly compare the results of microbial assessment and ATP quantification, and to suggest possible detailed application methods of the ATP test for hygiene evaluation in pigpens of a farrowing unit. Before and after standard cleaning procedures, samples were collected from the floor corner, floor center, and feeding trough of four pigpens at different time points. No FIB were detected and both the TAB and ATP levels were significantly decreased in the floor center area after cleaning. FIB were continuously detected after cleaning and disinfection of the floor corners, and there was no significant ATP level reduction. The feeding trough did not show any significant difference in these values before and after cleaning, indicating insufficient cleaning of this area. The levels of TAB and ATP after cleaning were significantly correlated and the average ATP value was significantly lower in the absence of FIB than in their presence. In the absence of standard references, a more thorough hygiene management could be achieved evenly by supplementing cleaning or disinfection based on the lowest ATP results obtained at the cleanest test site, which in the present study was the floor center. Overall, these results indicate that the on-farm ATP test can be used to determine the cleanliness status, in addition to visual inspection, as an alternative to laboratory culture-based testing for the presence of microorganisms.

Effect of Floor Space Allowance on Pig Productivity across Stages of Growth: A Field-scale Analysis

  • Lee, Joon H.;Choi, Hong L.;Heo, Yong J.;Chung, Yoon P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.5
    • /
    • pp.739-746
    • /
    • 2016
  • A total of 152 pig farms were randomly selected from the five provinces in South Korea. During the experiment, the average temperature and relative humidity was $24.7^{\circ}C$ and 74% in summer and $2.4^{\circ}C$ and 53% in winter, respectively. The correlation between floor space allowance (FSA) and productivity index was analyzed, including non-productive sow days (NPD), number of weaners (NOW), survival rate (SR), appearance rate of A-grade pork (ARA), and days at a slaughter weight of 110 kg (d-SW) at different growth stages. The objectives of the present study were i) to determine the effect of FSA on the pig productivity index and ii) to suggest the minimum FSA for pigs based on scientific baseline data. For the pregnant sow, NPD could be decreased if pregnant sows were raised with a medium level (M) of FSA (3.10 to $3.67m^2/head$) while also keeping the pig house clean which improves hygiene, and operating the ventilation system properly. For the farrowing sows, the NOW tended to decrease as the FSA increased. Similarly, a high level of FSA (H) is significantly negative with weaner SR of farrowing sows (p-value = 0.017), indicating this FSA tends to depress SR. Therefore, a FSA of 2.30 to $6.40m^2/head$ (very low) could be appropriate for weaners because a limited space can provide a sense of security and protection from external interruptions. The opposite trend was observed that an increase in floor space (> $1.12m^2/head$ leads to increase the SR of growing pigs. For the fattening pigs, H level of FSA was negatively correlated with SR, but M level of FSA was positively correlated with SR, indicating that SR tended to increase with the FSA of 1.10 to $1.27m^2/head$. In contrast, ARA of male fattening pigs showed opposite results. H level of FSA (1.27 to $1.47m^2/head$) was suggested to increase productivity because ARA was most affected by H level of space allowance with positive correlation ($R^2=0.523$). The relationship between the FSA and d-SW of fattening pigs was hard to identify because of the low $R^2$ value. However, the farms that provided a relatively large floor space (1.27 to $1.54m^2/head$) during the winter period showed d-SW was significantly and negatively affected by FSA.

Evaluation of the Magnetic Field Exposure Level in 60 Hz High Voltage Transmission Lines Nearby Residential Area (60 Hz 고압송전선로 인접 주거지역의 자기장 노출수준 평가)

  • Hong, Seung-Cheol;Jung, Joon-Sig;Kim, Keun-Young;Park, Hyun-Ju;Choi, Sung-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.1
    • /
    • pp.27-33
    • /
    • 2008
  • In order to evaluate the magnetic field (MF) exposure level in residential areas near high voltage power lines, this research measured MF levels at 120 sites near high voltage transmission lines in the Busan region, Gwangju region, Daegu region and Changwon region from July to December, 2005, and compared and analyzed the efficiencies by measuring and applying the MF emission levels of underground cables and high voltage transmission lines. As a result of the investigation of the MF exposure level by the building usage, the average MF level of 17 locations at schools was $2.44{\pm}2.45mG;$ that of 10 locations at hospitals $6.21{\pm}12.39mG;$that of 76 locations at apartments $2.55{\pm}2.98mG;$ and that at kindergartens and infant houses $3.32{\pm}4.21mG$. MF exposure was analysed as a function of distance from the source and the MF levels directly below a source were $5.15{\pm}8.72mG$, those within 30 m were $3.10{\pm}3.32mG$, while those within 50 m were $2.45{\pm}2.38mG$, and within 100 m were $0.71{\pm}0.93mG$. In order to determine the difference of MF levels by the actual distance from high voltage transmission line within the same building, the evaluation of the floor position and the MF level has shown that the MF levels were highest in the order of roof, 4th floor, 3rd floor, 2nd floor and 1st floor. Comparison of MF emission intensity of underground cables and high voltage transmission lines, has shown that underground cables have an 86-94% of reduction ratio in MF compared to high voltage transmission lines, thus demonstrating higher efficiency.