• 제목/요약/키워드: Average Surface Roughness

검색결과 329건 처리시간 0.024초

Cemented Carbide기판의 레이저 표면 개질이 다이아몬드 박막의 접합력에 미치는 영향 (Effect of Laser Surface Modification of Cemented Carbide Substrates on the Adhesion of Diamond Films)

  • 이동구
    • 열처리공학회지
    • /
    • 제13권3호
    • /
    • pp.170-176
    • /
    • 2000
  • A novel method for improving the adhesion of diamond films on cemented carbide tool inserts has been investigated. This method is based on the formation of a compositionally graded interface by developing a microrough surface structure using a pulsed laser process. Residual stresses of diamond films deposited on laser modified cemented carbides were measured as a function of substrate roughness using micro-Raman spectroscopy. The surface morphology and roughness of diamond films and cemented carbides were also investigated at different laser modification conditions. It was found that the increasing interface roughness reduced the average residual stress of diamond films, resulting in improved adhesion of diamond films on cemented carbides.

  • PDF

Ni기 내열합금의 표면조도에 의한 전해가공조건의 설정 (Determination of ECM parameter Base on surface Roughness for Ni base Heat Resistant Alloy)

  • 이상준;정윤교
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1999년도 춘계학술대회 논문집
    • /
    • pp.256-262
    • /
    • 1999
  • By development of heat resistant alloy, there are much improvement of gas turbine engines. But heat resistant alloy has difficulty of machining. therefore, ECM (Electrochemical Machining) is used for Machining of 3 dimensional curved surface of Ni-base alloy. The purpose of this paper is to investigate ECM parameters that make tile good surface for Ni-base alloy blade. For this purpose, we have been investigated that center line average surface roughness(R$\sub$a/), average R$\sub$a/, Maximum R$\sub$a/ and Standard deviation of R$\sub$a/ for measuring positions is influenced on ECM parameters such as electrolyte types, dwell time, electrolyte pressure and sort of electrolyte for Inconel 718 and Waspaloy.

  • PDF

직사각형 형상의 표면조도 변화에 의한 난류변동분 해석 (Analysis of Turbulent Velocity Fluctuations of Rectangular Shape of the Surface Roughness Change)

  • 오대균;오우준;김도정;이경우
    • 해양환경안전학회지
    • /
    • 제17권2호
    • /
    • pp.167-172
    • /
    • 2011
  • 표면조도에 의해 발생하는 난류유동은 공학적, 물리적 분야에서 매우 중요하게 다루어지고 있다. 표면조도는 선박에서도 설계, 용접, 도장 등 각각의 단계에서 다양한 측면으로 고려되어야 할 중요한 요소이다. 본 연구는 표면조도 형상을 일반화하여 PIV기법을 적용하여 수조실험을 수행하였다. 표면조도 조건은 거칠기 형상의 간격에 대해 변화를 주었으며, 실험유속은 Re = $1.1{\times}10^4$, Re = $2.0{\times}10^4$, Re = $2.9{\times}10^4$ 에서 시간평균에 대한 난류강도를 알아보았다. 거칠기 계수 증가에 따라 표면 거칠기 형상 근처에서 발생한 난류성분에 의해 난류강도는 강하게 나타났으며, 자유흐름 영역으로 갈수록 유동 방향의 변동이 전혀 없는 흐름이 나타났다. 실험유속 조건 변화에 대한 난류강도의 편차는 크게 영향을 받지 않았다.

Evaluation of efficiency of manual polishing over autoglazed and overglazed porcelain and its effect on plaque accumulation

  • Haralur, Satheesh B.
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권4호
    • /
    • pp.179-186
    • /
    • 2012
  • PURPOSE. The aim of this study was to evaluate the efficiency of manual polishing over autoglazed and overglazed porcelain and their effect on plaque accumulation. MATERIALS AND METHODS. Thirty-six porcelain discs were fabricated out of which 18 each was subjected for autoglazing and overglazing. Half surface of the discs was left intact; the remaining half was roughened with medium grit diamond bur. Roughened surfaces were repolished by porcelain polishing kits (Shofu, DFS, Eve). All the surfaces were evaluated by the perthometer and SEM. Six discs from each sample were placed in human volunteer's mouth for 72 hours to evaluate the plaque accumulation. Acquired data was subjected to ANOVA comparative evaluation. RESULTS. Roughened surfaces had average roughness value of $2.88{\pm}0.1935{\mu}m$. The repolished surfaces by porcelain correction kits Shofu, DFS and Eve, average roughness value reduced to $0.6250{\pm}0.1036$, $0.9192{\pm}0.0953$, $0.9017{\pm}0.1305$ respectively. Autoglazed and overglazed surfaces showed the mean roughness value (Ra) of $0.4217{\pm}0.0685$, $0.3450{\pm}0.0729$. SEM study showed the improved surfaces when subjected for polishing. Plaque accumulation percentage was the highest on roughened surface ($93.83{\pm}6.2552%$), followed by porcelain discs polished by commercial kits. Autoglazed surfaces found to be the best surfaces with the least plaque accumulation ($0.5237{\pm}0.4209%$). CONCLUSION. All the polishing kits used in the study reduced the average roughness by approximately 77%. Corrected porcelain surfaces should ideally be reglazed, alternatively, polish the surfaces before final cementation.

3D 프린터로 출력된 치과용 레진의 자동바렐연마공정에 따른 표면 거칠기 및 연마도 관찰 (Observation of surface roughness and grinding angle by automatic barrel finishing process of dental 3D printed resin)

  • 박유진;정안나
    • 대한치과기공학회지
    • /
    • 제45권2호
    • /
    • pp.39-47
    • /
    • 2023
  • Purpose: This study aimed to confirm the applicability of gloss polishing using automatic barrel finishing with respect to three-dimensional (3D)-printed resin specimens. The surface roughness and grinding angle of the 3D-printed resin specimens were observed with respect to gloss polishing time using automatic dental barrel finishing. Methods: Herein, experiments were conducted on four types of 3D-printed resin specimens. The specimens, with a thickness of 100 ㎛ each, were printed using a 3D printer. Subsequently, light polymerization was performed on these specimens for 15 min. Post this surface treatment, the specimens underwent grinding for 25 min. This process was followed by gloss polishing at 5-min intervals for up to 25 min using automatic dental barrel finishing. The specimens were photographed using a 3D optical microscope, and their surface roughness and grinding angle were measured. Results: The Ra (centerline average roughness) values of all the specimens, except for crown & bridge 10 group and those in the control group that were not polished using automatic barrel finishing, were <0.2 ㎛. However, polishing time needs to be controlled to realize the desired surface roughness and grinding amount considering the hardness of the resin used. Conclusion: Gloss polishing of 3D-printed resin can be realized using automatic dental barrel finishing. However, polishing time needs to be controlled to realize the desired surface roughness and grinding amount considering the hardness of the resin used.

Comparison of the effect of hand instruments, an ultrasonic scaler, and an erbium-doped yttrium aluminium garnet laser on root surface roughness of teeth with periodontitis: a profilometer study

  • Amid, Reza;Kadkhodazadeh, Mahdi;Fekrazad, Reza;Hajizadeh, Farzin;Ghafoori, Arash
    • Journal of Periodontal and Implant Science
    • /
    • 제43권2호
    • /
    • pp.101-105
    • /
    • 2013
  • Purpose: The present study aimed to measure root surface roughness in teeth with periodontitis by a profilometer following root planning with ultrasonic and hand instruments with and without erbium-doped yttrium aluminium garnet (Er:YAG) laser irradiation. Methods: Sixty single-rooted maxillary and mandibular teeth, extracted because of periodontal disease, were collected. The crowns and apices of the roots were cut off using a diamond bur and water coolant. The specimens were mounted in an acrylic resin block such that a plain root surface was accessible. After primary evaluation and setting a baseline, the samples were divided into 4 groups. In group 1, the samples were root planned using a manual curette. The group 2 samples were prepared with an ultrasonic scaler. In group 3, after scaling with hand instrumentation, the roots were treated with a Smart 1240D plus Er:YAG laser and in group 4, the roots were prepared with ultrasonic scaler and subsequently treated with an Er:YAG laser. Root surface roughness was then measured by a profilometer (MahrSurf M300+RD18C system) under controlled laboratory conditions at a temperature of $25^{\circ}C$ and 41% humidity. The data were analyzed statistically using analysis of variance and a t-test (P<0.05). Results: Significant differences were detected in terms of surface roughness and surface distortion before and after treatment. The average reduction of the surface roughness after treatment in groups 1, 2, 3, and 4 was 1.89, 1.88, 1.40, and 1.52, respectively. These findings revealed no significant differences among the four groups. Conclusions: An Er:YAG laser as an adjunct to traditional scaling and root planning reduces root surface roughness. However, the surface ultrastructure is more irregular than when using conventional methods.

다양한 치은 연하 수복물에 대한 치은 섬유아 세포 부착 연구 (Attachment of Human Gingival Fibroblast to Various Subgingival Restorations;A Comparative Study in Vitro)

  • 이은숙;송인택;임정수;김형섭
    • Journal of Periodontal and Implant Science
    • /
    • 제29권3호
    • /
    • pp.621-636
    • /
    • 1999
  • When mucoperiosteal flaps are positioned and sutured to desirable position, the wound contains several interface between tissues which differ fundamentally in composition & biological reaction. Thus the C-T surface of the flap will, on one hand, oppose another vascularized surface, and on the other, the avascular dental material for example, when root resoptions, fractured root, endodontic perforation, deep root carious lesions were filled with amalgam, glass ionomer, resin etc. Recently, a number of case report described the successful treatment of a subgingival root lesion with restorative material & free gingival graft, open flap surgery, but more objective research was needed . Most of study on restorative materials were concerned for cytotoxicity not for actual healing event on that materials and its influencing factors such as biocompatibility, surface wettability, surface topography . The aim of this in vitro study was to evaluate the effect of amalgam, resin modified glass ionomer, composite resin per se, and their surface roughness on the growth of human gingival fibroblast. The cells were obtained and placed on culture flask and incubated for 3 days with the prepared test materials. Then count the attached cell number with hemocytometer,(n=12) and 2 samples were examined with SEM about attachment cell morphology . Another 4 samples were evaluated on their surface roughness with Talysurf and average surface roughness value(Ra) were obtained. Statistical difference in attached cell number, roughness value were analyzed using ANOVA. The number of attached cell was as follows, for root dentin specimen 16.7${\pm}$4.41, resin modified glass ionomer 14.0${\pm}$4.15, resin 8.13${\pm}$3.63, amalgam 0.72${\pm}$3.33(${\times}10^3$). Between root dentin and resin-modified glass ionomer, no significant difference was observed, but resin, amalgam showed a significant less cell numbers than for root dentin, resin modified glass ionomer cement. SEM examination expressed many cell surface attachment apparatus in root dentin and resin modified glass ionomer specimens. For resin specimen, cell attachment was observed but exposed less appratus. The average surface roughness value are following results. Dentin specimen 0.6972${\pm}$ 0.104, resin modified glass ionomer 0.0822${\pm}$0.009, resin 0.0875${\pm}$0.005, amalgam 4.2145${\pm}$0.985(${\mu}m$). Between root dentin, resin-modified glass ionomer, and resin, no significant difference was observed, but amalgam showed a significant more rough surface than other groups. When evlauated the interrelationship between cell attachment and surface roughness, therefore, there was weak reverse correlation.(pearson correlation : - 0.593) These results suggest that resin modified glass ionomer have the favorable healing potential when used for subgingival restoration. And for relationship between cell attachment and surface characteristics, further investigations were needed.

  • PDF

초음파 진동판의 표면조도에 따른 분무특성에 관한 연구 (Characterization of Sprays used Ultrasonic Vibrant Plate with the Surface roughness)

  • 이준백;전인곤;전흥신
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.732-737
    • /
    • 2000
  • The purpose of this study is to compare the SMD(Sauter mean diameter) with different vibrant plates. Each vibrant plates have different surface roughness. Also liquid film thickness are measured for explanation how to concern atomization. Ultrasonic waves is used for vibration. Immersion liquid method is used for the measure of SMD and also liquid film thickness is measured using of point needle method. Distilled water and gasoline fuel are used to liquids. Supplied liquid flow rates are $18{\sim}296cc/min$. Centerline average roughness of vibrant plates are 0.5, 2.0, 4.7, $9.5\;{\mu}m$ and diameter of vibrant plate is 60mm. In result, good atomization of liquid is obtained in widen flow rates. The mean droplet size is increased in orders of 4.7, 2.0. 9.5, $0.5\;{\mu}m$ surface roughness. Distilled water has a big mean droplet size than gasoline fuel in low flow rate. Above the 78cc/min flow rates, distilled water has a small mean droplet size than gasoline fuel. Liquid films changes are measured with ultrasonic power. Also, cavitation effect on sprays is observed.

  • PDF

아노다이징 표면 처리된 항공기 저장조의 내면 정밀연마를 위한 제조공정의 개선 (Manufacturing Process Improvement for Precision Inner Surface Polishing of Anodizing Treated Airplane Reservoir)

  • 김웅범;조영태;정윤교;최정동
    • 한국기계가공학회지
    • /
    • 제15권2호
    • /
    • pp.72-77
    • /
    • 2016
  • Airplane reservoirs made of Al7075 are coated with an anodizing layer to maintain precision, air tightness and corrosion resistance. It is commonly required that the inner surface roughness of the reservoir be less than an average $0.2{\mu}m$ to maintain stable oil pressure. Even though precision polishing is necessary to achieve this quality it is not easy. Inner surface roughness is not uniform and the quality of the product is irregular because most of the work is done by hand. The purpose of this study is to design an exclusive polishing machine and to determine the standard cutting condition and polishing condition necessary for good inner surface roughness and to improve workefficiency.

반사판의 표면거칠기와 구조의 오정렬에 의한 파라볼라 반사판 안테나 패턴 일그러짐 계산 (Calculation for the pattern degradation of the parabolic reflector caused by both the surface roughness of the reflector and the structural misalignment)

  • 김주완;김병성;남상욱;이충웅
    • 전자공학회논문지A
    • /
    • 제32A권1호
    • /
    • pp.36-44
    • /
    • 1995
  • For a parabolic reflector antenna, a simple method is presented for computing efficiently the average power pattern degradations caused by the surface roughness of the reflector and misalignments between the reflector and the feed. In this procedure, both nonuniform surface errors and nonuniform illuminations are employed. The assumptions to derive the expressions are that in each annular region of the antenna, the rms value of the surface roughness is known, and in a zone in a annular region, the phase error by misalignments is constant, and can be taken to its value at the center of the zone. Detailed parametric studies are performed with derived expressions to determine the effects of those errors and illumination tapers on parameters such as gain and sidelobe levels.

  • PDF