• 제목/요약/키워드: Average Model Of Switch

검색결과 24건 처리시간 0.019초

스위치 평균 모델을 이용한 DC/DC 컨버터 모델링 및 임계특성에 관한 연구 (The DC/DC converter modeling using average model of switch and critical characterist)

  • 배진용;김용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.129-133
    • /
    • 2005
  • This paper discusses DC/DC converter modeling using average model of switch and critical characterist. Average model of switch approach is expended to the modeling of boundary conduction mode DC/DC converters that operate at the boundary between Continuous Conduction Mode(CCM) and Discontinuous Conduction Mode(DCM). Frequency responses predicted by the average model of switch are verified by simulation and experiment.

  • PDF

스위치 평균 모델을 이용한 DC/DC 컨버터의 전류불연속모드 모델링과 임계특성에 관한 연구 (The Discontinuous Conduction Mode(DCM) Modeling of DC/DC Converter and Critical Characteristic using Average Model of Switch)

  • 배진용;김용
    • 조명전기설비학회논문지
    • /
    • 제22권6호
    • /
    • pp.34-43
    • /
    • 2008
  • 상태 공간 평균화 모델은 강압형, 승압형 및 승 강압형 DC/DC 컨버터에 적용이 가능하며, 특별한 계산이 필요 없는 높은 정밀도가 증명된 모델이다. 이러한 모델은 전류연속모드(CCM) DC/DC 컨버터에서 확립되었으며, 본 논문에서는 컨버터의 전류연속모드(CCM) 모델로부터 의미 있는 결론을 유도하고자 한다. 본 논문에서는 스위치 평균모델을 이용한 DC/ DC 컨버터의 전류불연속모드(DCM) 모델링 및 임계특성에 관하여 논하였다. 스위치 평균 모델은 전류연속모드(CCM)와 전류불연속모드(DCM) 사이의 DC/DC 컨버터의 경계 조건에 대한 모델로부터 유추할 수 있으며, 시뮬레이션과 실험에 의해서 스위치의 평균 모델의 주파수 응답 특성을 예측할 수 있었다. 본 연구에서는 MOSFET를 사용하여 입력전압 15[V], 출력전압 24[V], 출력전력 24[W]급 시스템을 제작하여 실험하였다.

ATM 교환기를 위한 TMN 관리 대행 시스템의 구현 (Implementation of TMN Agent for ATM switch : considering integration of agent into ATM switch)

  • 황희산;이병윤;이길행;우왕돈
    • 한국통신학회논문지
    • /
    • 제23권5호
    • /
    • pp.1360-1371
    • /
    • 1998
  • ATM 교환기 관리를 위한 TMN 시스템의 개발에 있어, ATM 교환기와 관리 대행자간의 구조적 결합 방법에 따라 여러가지 형태의 구현 방법이 존재할 수 있다. Embedded Agent와 Gateway Agent와 같은 분류가 그 대표적인 것이라 하겠다. 지금까지의 TMN 시스템의 개발에 있어, 이들 구현 방법들에 대한 객관적 평가를 통한 적절한 구현 모델의 선택이 거의 이루어지지 않았다. 본 논문에서는 ATM 교환기를 위한 관리 대행자 시스템의 개발에 있어, 가장 먼저 선행되어져야 할 구현 모델 선택을 위해, 5가지의 구현 모델을 설정하고, 각 구현 모델에 대해 MIB 구현 측면, ATM 교환기 내부 프로토콜 측면, 구현의 용이성 측면을 평가한 후, 가장 적절한 구현 모델 하나를 선택하였다. 또한 이 선택된 모델을 기초로 관리 대행 시스템을 구현하였고, 구현 모델의 이점을 극대화하기 위한 관리 대행자와 교환기간의 인터페이스 모델을 제안, 구현하였다. 또한 구현된 관리 대행 시스템을 실제 TMN 관리 시스템에 적용하여 그 성능을 평가하였다.

  • PDF

광역 무선 Trunking 시스템의 통신용량 분석에 관한 연구 (A study on the capacity analysis of wide area radio trunking system)

  • 김낙명
    • 전자공학회논문지S
    • /
    • 제34S권4호
    • /
    • pp.1-11
    • /
    • 1997
  • In this paper, modeling of the communication channel occupancy characteristics at the base station in the wide area radio trunking syste has been performed. Using the results, mathematical analysis for the switching capacity at the network switch has also been done. Specificatlly, we propose a G/M/m queueing model for the single service area modeling, and analyze changes in call blockingprobabilities accoridng to changes in the burstness characteristics of group paging calls. As a result, we have observe dthat the channel occupancy variations become larger as the burstness characteristics become more apparent, to make the call blocking probability higher. Next, based on the single service area analysis, we have anayzed mathematically the average switching capacity required to serve mobile subscribers for a wide area radio trunking sytem, where multiple switching port assignments are required when the people in the same group are distributed over several base stations. Accordingly, we have observed that the average and the variance of switching channel occupancy are closely related to the mobility characteristics of subscribers, and that we need a netowrk switch having bigger capacity as subscribers show wider distribution. Especially, with the call dropping probability within 0.2%, a switch having about 5 to 6 times bigger can be required, compared with the one when the mobility of subscribers is mostly restricte dto a single service area.

  • PDF

Three-phase Three-level Boost-type Front-end PFC Rectifier for Improving Power Quality at Input AC Mains of Telecom Loads

  • Saravana, Prakash P.;Kalpana, R.;Singh, Bhim
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1819-1829
    • /
    • 2018
  • A three-phase, three-switch, and three-level boost-type PWM rectifier (Vienna rectifier) is proposed as an active front-end power factor correction (PFC) rectifier for telecom loads. The proposed active front-end PFC rectifier system is modeled by the switching cycle average model. The relation between duty ratios and DC link capacitor voltages is derived in terms of the system input currents. Furthermore, the feasible switching states are identified and applied to the proposed system to reduce the switching stress and DC ripples. A detailed equivalent circuit analysis of the proposed front-end PFC rectifier is conducted, and its performance is verified through simulations in MATLAB. Simulation results are verified using an experimental setup of an active front-end PFC rectifier that was developed in the laboratory. Simulation and experimental results demonstrate the improved power quality parameters that are in accordance with the IEEE and IEC standards.

Joint routing, link capacity dimensioning, and switch port optimization for dynamic traffic in optical networks

  • Khan, Akhtar Nawaz;Khan, Zawar H.;Khattak, Khurram S.;Hafeez, Abdul
    • ETRI Journal
    • /
    • 제43권5호
    • /
    • pp.799-811
    • /
    • 2021
  • This paper considers a challenging problem: to simultaneously optimize the cost and the quality of service in opaque wavelength division multiplexing (WDM) networks. An optimization problem is proposed that takes the information including network topology, traffic between end nodes, and the target level of congestion at each link/ node in WDM networks. The outputs of this problem include routing, link channel capacities, and the optimum number of switch ports locally added/dropped at all switch nodes. The total network cost is reduced to maintain a minimum congestion level on all links, which provides an efficient trade-off solution for the network design problem. The optimal information is utilized for dynamic traffic in WDM networks, which is shown to achieve the desired performance with the guaranteed quality of service in different networks. It was found that for an average link blocking probability equal to 0.015, the proposed model achieves a net channel gain in terms of wavelength channels (𝛾w) equal to 35.72 %, 39.09 %, and 36.93 % compared to shortest path first routing and 𝛾w equal to 29.41 %, 37.35 %, and 27.47 % compared to alternate routing in three different networks.

Asymptotic Performance Analysis of Free-Space Optical Links with Transmit Diversity

  • Feng, Jianfeng;Zhao, Xiaohui
    • Journal of the Optical Society of Korea
    • /
    • 제20권4호
    • /
    • pp.451-463
    • /
    • 2016
  • The misalignment errors and fluctuations in irradiance due to atmospheric turbulence can severely degrade the performance of free-space optical (FSO) systems. In this paper, we investigate the asymptotic bit error rate (BER) performance and diversity orders of FSO links using parallel transmit-diversity schemes. The BER expressions of FSO links with the switch-and-examine transmit (SET), switch-and-examine transmit with post-selection (SETps), dual-branch transmit laser selection (Dual-TLS), and group transmit laser selection (Group-TLS) schemes are derived, based on an approximate channel model. Then numerical simulations for these four schemes in the region of high average signal-to-noise ratio (SNR) are presented under different channel conditions. The results show that the four transmit-diversity schemes can reduce system complexity and overcome the limitation of peak power, without much BER deterioration.

자동차용 전동시스템 해석을 위한 평균값 인버터 모델 개발 (Development of Average Inverter Model for Analysis of Automotive Electric Drive System)

  • 최진철;배규태;이우택
    • 한국자동차공학회논문집
    • /
    • 제18권6호
    • /
    • pp.23-30
    • /
    • 2010
  • A detailed circuit level model requires a small sampling time to represent high frequency switching behaviors with proper resolution. The small sampling time leads a large execution time to obtain the system analysis results. As the alternative of the detailed circuit model, an averaged PWM switch model was proposed for the rapid system level analysis. There exists a voltage distortion between the reference and output voltage because of non-ideal switching characteristics, such as the dead-time, diode forward voltage drop and conduction resistance. This paper analyzed causes and effects of the voltage distortion. The average inverter model, which reflecting this voltage distortion, is developed for the rapid and accurate analysis of automotive electric drive system in MATLAB/Simulink environment. The rapidity and accuracy of the proposed inverter model is proved through comparison between simulation and experiment.

스위치 레벨 CMOS 지연시간 모델링과 파라미터 추출 (A Switch-Level CMOS Delay Time Modeling and Parameter Extraction)

  • 김경호;이영근;이상헌;박송배
    • 전자공학회논문지A
    • /
    • 제28A권1호
    • /
    • pp.52-59
    • /
    • 1991
  • An effective and accurate delay time model is the key problem in the simulation and timing verification of CMOS logic circuits. We propose a semi-analytic CMOW delay time model taking into account the configuration ratio, the input waveform slope and the load capacitance. This model is based on the Schichman Hodges's DC equations and derived on the optimally weighted switching peak current. The parameters necessary for the model calculation are automatically determined from the program. The proposed model is computationally effective and the error is typically within 10% of the SPICEA results. Compared to the table RC model, the accuracy is inproved over two times in average.

  • PDF

Finite Control Set Model Predictive Current Control for a Cascaded Multilevel Inverter

  • Razia Sultana, W.;Sahoo, Sarat Kumar
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1674-1683
    • /
    • 2016
  • In this paper, a Finite Control Set Model Predictive Control (FCS-MPC) for a five level cascaded multilevel inverter (CMLI) with reduced switch topology is proposed. Five switches are used here instead of conventionally used eight switches. The main contribution of this paper is to make the MPC controller work for the reduced switch topology using only 19 voltage vectors in place of conventional 61 voltage vectors for a five level CMLI. This simplifies the execution of the MPC algorithm, paving a way for the significant reduction in the computational time. The controller makes use of the excellent ability of MPC to multitask, by adding one more objective which is to reduce the average switching frequency in addition to controlling the load current. This is especially important, since switching losses and therefore switching frequency is significant for high-power applications. The trade-off of this MPC is that the current is not as smooth as the 61 vector scheme, but well within the limits of IEEE standards. The results shown prove that this MPC works well in steady state and dynamic conditions too.