• Title/Summary/Keyword: Average Illumination

Search Result 203, Processing Time 0.021 seconds

Color recovery of a chromatic digital image based on estimation of spectral distribution of illumination (장원의 분광분포 추정에 기반한 유색 디지털 영상의 색복원)

  • 이철희;이응주
    • Journal of Korea Multimedia Society
    • /
    • v.4 no.2
    • /
    • pp.97-107
    • /
    • 2001
  • In this paper, an illuminant estimation algorithm of a chromatic digital images proposed. The proposed illumination estimation method has two phases. First, the surface spectral reflectances are recovered. In this case, the surface spectral reflectances recovered are limited to the maximum highlight region (MHR) which is the most achromatic and highly bright region of an image after applying intermediate color constancy process using a modified gray world algorithm. Next, the surface reflectances of the maximum highlight region are estimated using the principal component analysis method along with a set of given Munsell samples. Second, the spectral distribution of reflected lights of MHR is selected from the spectral database. That is a color difference is compared between the reflected lights of the MHR and the spectral database that is the set of reflected lights built by the given Munsell samples and a set of illuminants. Then the closest colors from the spectral database are selected. Finally, the illuminant of an image can be calculated dividing the average spectral distributions of reflected lights of MHR by the average surface reflectances of the MHR. In order to evaluate the proposed algorithm, experiments with artificial and real captured color-biased scenes were performed and numerical comparison examined. The proposed method was effective in estimating the spectral of the given illuminant sunder various illuminants.

  • PDF

Color Image Acquired by the Multispectral Near-IR LED Lights (다중 파장 근적외선 LED조명에 의한 컬러영상 획득)

  • Kim, Ari;Kim, Hong-Suk;Park, Youngsik;Park, Seung-Ok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.2
    • /
    • pp.1-10
    • /
    • 2016
  • A system which provides multispectral near-IR and visible gray images of objects is constructed and an algorithm is derived to acquire a natural color image of objects from the gray images. A color image of 24 color patches is obtained by recovering their CIE (International Commission on Illumination) LAB color coordinates $L^*$, $a^*$, $b^*$ from their gray images using the algorithm based on polynomial regression. The system is composed of a custom-designed LED illuminator emitting multispectral near-IR illuminations, fluorescent lamps and a monochrome digital camera. Color reproducibility of the algorithm is estimated in CIELAB color difference ${\Delta}E^*_{ab}$. And as a result, if yellow and magenta color patches with around 10 ${\Delta}E^*_{ab}$ are disregarded, the average ${\Delta}E^*_{ab}$ is 2.9, and this value is within the acceptability tolerance for quality evaluation for digital color complex image.

Histogram Specification Method Development for Accurate Visual Inspection (정확한 비전 검사를 위한 히스토그램 지정 기법 개발)

  • Park, Se-Hyuk;Kang, Su-Min;Han, Kwang-Hee;Huh, Kyung-Moo
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.145-146
    • /
    • 2008
  • The appearance inspection of various electronic products and parts has been executed by the eyesight of human. But inspection by eyesight cannot bring about uniform inspection result. Because the appearance inspection result by eyesight of human is changed by condition of physical and spirit of the checker. So machine vision inspection system is currently used to many appearance inspection fields instead of the checker. However the inspection result of machine vision is changed by the illumination of workplace. Therefore we proposed histogram specification in this paper for machine vision inspection accuracy. As a result of histogram specification algorithm, we could increase the exactness of visual inspection and prevent system error from physical and spirit condition of human. More specifically, average inspection error rate was 7.5[%] in existing inspection method but we could see 0.6[%] error rate after applying the algorithm which is presented in this paper.

  • PDF

Response of Rock Trout to the White Lights (백색광에 대한 쥐노래미의 반응)

  • 양용림
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.22 no.4
    • /
    • pp.56-60
    • /
    • 1986
  • The purpose of this study is to find the light intensity which induced maximum gathering rate and to observe the variation of the gathering rate both in daytime and at night by using rock trout, He.'~agrammos otakii (Jordan et starks). An experimental tank (360L x SOW x 55H cm) was set up in a dark room. An illumination system was attached to the end of one side of the tank to control horizontal light intensity. Six artificial light sources were prepared by combination of two light bulbs (5 W, 150 W) and seven filters. During the experiment water depth was maintained 50 em level in the tank. The tank was marked into six longitudinal sections each being 60 em long to observe the distribution of fish. The fish were acclimatized in dark condition for 50 minutes prior to the main experiment. Upon turning on the light, the number of fish in each section was counted 40 times every 30 seconds. and the gathering rate was obtained from the average number of fish in each section. The light intensity inducing maximum gathering rate was O. 7 lux (0. 5~1. 1 lux) in the daytime and 5. 2/ux (3.2-7.7 lux) at night. The variation of the gathering rate of fish in illumination time was sma II and showed the decreasing trend.

  • PDF

The Actual State of Indoor Environment in Solitary Elderly Houses at Rural District during Winter (농촌지역 독거노인주택의 겨울철 실내환경 실태)

  • Choi, Yoon-Jung;Kim, Yun-Hee;Kim, Lan-Hee
    • Journal of the Korean housing association
    • /
    • v.21 no.3
    • /
    • pp.1-9
    • /
    • 2010
  • The purposes of this study were to determine the actual state of indoor environments of solitary elderly houses in the rural district during winter and to analyze the relationship between the influencing factors and indoor physical elements. Field surveys consisted of measurements of physical elements, observations of living factors, and resident's responses in interviews. Field surveys were carried out in 4 houses from $28^{th}$ of February to $2^{nd}$ of March 2008. The elements measured were air temperature, relative humidity, floor temperature, seating-place temperature, CO2 concentration, CO concentration, and illumination. The results showed that the average indoor temperature for houses was $13.5{\sim}22.5^{\circ}C$, relative humidity was 30.6~55.4%, floor temperature was $13.9{\sim}24.0^{\circ}C$, temperature when seated was $27.6{\sim}51.1^{\circ}C$, $CO_2$ concentration was 1434.6~3305.5 ppm, CO concentration was 2.8~8.4 ppm, and illumination was 31.0~96.7 lux. The residents' clothing values were 1.10~1.78 clo. The environment was evaluated as being in an unsuitable state, and it was revealed that the main reason was the lack of heating and ventilation.

The Actual State of Indoor Environment in Solitary Elderly Houses at Rural District during Winter (농촌지역 독거노인주택의 겨울철 실내환경 실태)

  • Choi, Yoon-Jung;Kim, Yun-Hee;Kim, Lan-Hee
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.452-457
    • /
    • 2008
  • The purposes of this study were to determine the actual state of indoor environment and to analyze the relationship between the living factors and indoor physical elements in solitary elderly houses at rural district during winter. The field surveys were consisted of measurements of physical elements, observations of living factors, and interviews of resident's responses. The field surveys were fulfilled in 4 houses from February to March 2008. Measuring elements were air temperature, relative humidity, floor temperature, seated place temperature, $CO_2$, CO, and illumination. The results showed that the average of indoor temperature for houses was $13.5{\sim}22.5^{\circ}C$, relative humidity was $30.6{\sim}55.4%$, floor temperature was $13.9{\sim}24.0^{\circ}C$, seated place temperature was $27.6{\sim}51.1^{\circ}C$, $CO_2$ was $1434.6{\sim}3305.5ppm$, CO was $2.8{\sim}8.4ppm$, illumination was $31.0{\sim}96.7lux$. The residents' clothing values were $1.10{\sim}1.78clo$. Most of the residents' subjective responses were in discord with the physical elements. It was evaluated to be uncomfortable state, and the main reason was revealed lack of heating and ventilation.

  • PDF

Design and Fabrication of Light-guiding Plate for a Photobioreactor by Using Sunlight and Linear Fresnel Lens (태양광과 선형 프레넬 렌즈를 이용한 광생물반응기용 도광판 설계 및 제작)

  • Kim, Hun;Shin, Seong Seon;Hwang, Min Yong;Lim, Hyon Chol;Kim, Gwang Ho;Kim, Jong Tye;Jeong, Sang Hwa;Park, Jong Rak
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.2
    • /
    • pp.143-147
    • /
    • 2013
  • We present results of the optical design and fabrication of a light-guiding plate (LGP) for a photobioreactor by using sunlight and a linear Fresnel lens. LGP patterns were designed by optical simulations with an illumination design tool, LightTools, and fabricated by using a computerized numerical control machine. Optical characteristics of average deviation of illuminance distribution and light throughput efficiency were measured and compared with simulation results.

LED Dimming Control Using Manchester-Code Duty Factor And Spike Detection in Visible Light Communication (가시광통신에서 맨체스터코드 듀티율과 스파이크 검출을 이용한 LED 조명제어)

  • Lee, Seong-Ho
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.571-579
    • /
    • 2019
  • Visible light communication (VLC) performs illumination and communication simultaneously, thus it is important to prevent the flicker due to the optical power variation during data transmission and at the same time to have dimming control capability. In this paper, we used Manchester code for flicker-prevention and dimming control. In the transmitter, the duty factor of the Manchester code was used for controlling the LED illumination. In the receiver, the edge-spike signals of an RC-high pass filter were used for recovering the Manchester code while preventing the adjacent noise light. In experiments, the LED light was kept flicker-free and the average optical power was controlled in the range of 8~68 % of the continuous wave (CW) LED light by changing the duty factor of the Manchester code.

A Vehicular License Plate Recognition Framework For Skewed Images

  • Arafat, M.Y.;Khairuddin, A.S.M.;Paramesran, R.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.11
    • /
    • pp.5522-5540
    • /
    • 2018
  • Vehicular license plate (LP) recognition system has risen as a significant field of research recently because various explorations are currently being conducted by the researchers to cope with the challenges of LPs which include different illumination and angular situations. This research focused on restricted conditions such as using image of only one vehicle, stationary background, no angular adjustment of the skewed images. A real time vehicular LP recognition scheme is proposed for the skewed images for detection, segmentation and recognition of LP. In this research, a polar co-ordinate transformation procedure is implemented to adjust the skewed vehicular images. Besides that, window scanning procedure is utilized for the candidate localization that is based on the texture characteristics of the image. Then, connected component analysis (CCA) is implemented to the binary image for character segmentation where the pixels get connected in an eight-point neighbourhood process. Finally, optical character recognition is implemented for the recognition of the characters. For measuring the performance of this experiment, 300 skewed images of different illumination conditions with various tilt angles have been tested. The results show that proposed method able to achieve accuracy of 96.3% in localizing, 95.4% in segmenting and 94.2% in recognizing the LPs with an average localization time of 0.52s.

Rotation Invariant Tracking-Learning-Detection System (회전에 강인한 실시간 TLD 추적 시스템)

  • Choi, Wonju;Sohn, Kwanghoon
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.5
    • /
    • pp.865-873
    • /
    • 2016
  • In recent years, Tracking-Learning-Detection(TLD) system has been widely used as a detection and tracking algorithm for vision sensors. While conventional algorithms are vulnerable to occlusion, and changes in illumination and appearances, TLD system is capable of robust tracking by conducting tracking, detection, and learning in real time. However, the detection and tracking algorithms of TLD system utilize rotation-variant features, and the margin of tracking error becomes greater when an object makes a full out-of-plane rotation. Thus, we propose a rotation-invariant TLD system(RI-TLD). we propose a simplified average orientation histogram and rotation matrix for a rotation inference algorithm. Experimental results with various tracking tests demonstrate the robustness and efficiency of the proposed system.