• Title/Summary/Keyword: Average Current Mode

Search Result 161, Processing Time 0.033 seconds

Small Signal Analysis and Controller Design for Interleaved DC-DC Dual Boost Converter in Discontinuous Current Mode (불연속전류모드에서 interleaved DC-DC dual boost 컨버터용 소 신호 해석 및 제어기 설계)

  • Park Joo Moon;Park Sang Eun;Kuk Jung Hyun;Hwang Young Seong;Kim Young Roc;Seong Se Jin
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.530-533
    • /
    • 2001
  • Interleaved Dual Boost(IDB) converter can reduce current ripple, switching loss and harmonics without filter in input power line. Moreover, this improve power factor. In this paper, we will use the state average methode and small signal analysis at the Interleaved dual boost converter. 4-type controllers were designed by using control transfer function. The result of these controller simulations is analyzed and proposed a proper controller at IDB

  • PDF

Implementation of a Digital Ballast for HID Lamps (HID 램프 디지털 안정기의 제작)

  • 이치환
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.31-35
    • /
    • 2003
  • This paper presents a microprocessor controlled digital ballast for HID lamps, which gives intelligent features such as a precise power control, optimum ignition voltage and detection of end of life. Average current mode PFC is employed for reducing EMI and a universal input. Direct spread spectrum is done by applying 1 KHz triangular wave for removing acoustic resonance. This frequency modulation of 1 KHz gives also low EMI level and no ripple on lamp current. The microprocessor controls the voltage of DC-bus, the voltage of ignition pulses, the power of output and the bandwidth of spread spectrum. A 250W digital ballast is implemented with an efficiency of 93% and a maximum EMI level of 55 ㏈${\mu}$V.

  • PDF

Analysis and Design of a Single-Phase Tapped-Coupled-Inductor Boost DC-DC Converter

  • Gitau, Michael Njoroge;Mwaniki, Fredrick Mukundi;Hofsajer, Ivan W.
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.636-646
    • /
    • 2013
  • A single-phase tapped-inductor boost converter has been proposed previously. However, detailed characterization and performance analysis were not conducted. This paper presents a detailed characterization, performance analysis, and design expressions of a single-phase tapped-coupled-inductor boost converter. Expressions are derived for average and RMS input current as well as for RMS input and output capacitor current ripple. A systematic approach for sizing the tapped-coupled inductor, active switch, and output diode is presented; such approach has not been reported in related literature. This study reveals that sizing of the inductor has to be based on current ripple requirement, turns ratio, and load. Conditions that produce discontinuous inductor current are also discussed. Analysis of a non-ideal converter operating in continuous conduction mode is also conducted. The expression for the voltage ratio considering the coupling coefficient is derived. The suitability of the converter for high-voltage step-up applications is evaluated. Factors that affect the voltage boost ratio are also identified. The effects of duty ratio and load variation on the performance of the converter are also investigated. The theoretically derived characteristics are validated through simulations. Experimental results obtained at a low power level are included to validate the analytical and simulation results. A good agreement is observed among the analytical, simulation, and experimental results.

Bayesian-theory-based Fast CU Size and Mode Decision Algorithm for 3D-HEVC Depth Video Inter-coding

  • Chen, Fen;Liu, Sheng;Peng, Zongju;Hu, Qingqing;Jiang, Gangyi;Yu, Mei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.4
    • /
    • pp.1730-1747
    • /
    • 2018
  • Multi-view video plus depth (MVD) is a mainstream format of 3D scene representation in free viewpoint video systems. The advanced 3D extension of the high efficiency video coding (3D-HEVC) standard introduces new prediction tools to improve the coding performance of depth video. However, the depth video in 3D-HEVC is time consuming. To reduce the complexity of the depth video inter coding, we propose a fast coding unit (CU) size and mode decision algorithm. First, an off-line trained Bayesian model is built which the feature vector contains the depth levels of the corresponding spatial, temporal, and inter-component (texture-depth) neighboring largest CUs (LCUs). Then, the model is used to predict the depth level of the current LCU, and terminate the CU recursive splitting process. Finally, the CU mode search process is early terminated by making use of the mode correlation of spatial, inter-component (texture-depth), and inter-view neighboring CUs. Compared to the 3D-HEVC reference software HTM-10.0, the proposed algorithm reduces the encoding time of depth video and the total encoding time by 65.03% and 41.04% on average, respectively, with negligible quality degradation of the synthesized virtual view.

A Study on the Design of D/A Converter based on Data Weighted Average Technique for enhancement of reliability (혼합형 전류 구동 D/A 컨버터 설계 제작에 있어서 데이터 가중평균기법을)

  • Kim, S.D.;Woo, Y.S.;Kim, D.G.;Sung, M.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3215-3217
    • /
    • 1999
  • In this paper, a new structure of realizing switching control logic for Data Weighted Average Technique is suggested. It uses memory and adder for summing past binary input and this summed data is used to select one switch in control logic. This control logic acts in parallel regardless of resolution so increasing resolution don't affect on converting speed. In this reason, high speed and high resolution D/A converter based on Data Weighted Average Technique could be made. In this paper, 4 bits current mode thermometer code D/A converter is degined and simulated by using HSPICE. Simulated results show that new structure of D/A converter has more than 250MHz converting speed and less than 0.0003[LSB] INL error. It is very useful in low power circuit because of using 3.3 V supply voltage.

  • PDF

Multi-channel Transimpedance Amplifier Arrays in Short-Range LADAR Systems for Unmanned Vehicles (무인차량용 단거리 라이다 시스템을 위한 멀티채널 트랜스임피던스 증폭기 어레이)

  • Jang, Young Min;Kim, Seung Hoon;Cho, Sang Bock;Park, Sung Min
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.40-48
    • /
    • 2013
  • This paper presents multi-channel transimpedance amplifier(TIA) arrays in short-range LADAR systems for unmanned vehicles, by using a 0.18um CMOS technology. Two $4{\times}4$ channel TIA arrays including a voltage-mode INV-TIA and a current-mode CG-TIA are introduced. First, the INV-TIA consists of a inverter stage with a feedback resistor and a CML output buffer with virtual ground so as to achieve low noise, low power, easy current control for gain and impedance. Second, the CG-TIA utilizes a bias from on-chip bandgap reference and exploits a source-follower for high-frequency peaking, yielding 1.26 times smaller chip area per channel than INV-TIA. Post-layout simulations demonstrate that the INV-TIA achieves 57.5-dB${\Omega}$ transimpedance gain, 340-MHz bandwidth, 3.7-pA/sqrt(Hz) average noise current spectral density, and 2.84mW power dissipation, whereas the CG-TIA obtains 54.5-dB${\Omega}$ transimpedance gain, 360-MHz bandwidth, 9.17-pA/sqrt(Hz) average noise current spectral density, and 4.24mW power dissipation. Yet, the pulse simulations reveal that the CG-TIA array shows better output pulses in the range of 200-500-Mb/s operations.

Lossless Compression for Hyperspectral Images based on Adaptive Band Selection and Adaptive Predictor Selection

  • Zhu, Fuquan;Wang, Huajun;Yang, Liping;Li, Changguo;Wang, Sen
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.8
    • /
    • pp.3295-3311
    • /
    • 2020
  • With the wide application of hyperspectral images, it becomes more and more important to compress hyperspectral images. Conventional recursive least squares (CRLS) algorithm has great potentiality in lossless compression for hyperspectral images. The prediction accuracy of CRLS is closely related to the correlations between the reference bands and the current band, and the similarity between pixels in prediction context. According to this characteristic, we present an improved CRLS with adaptive band selection and adaptive predictor selection (CRLS-ABS-APS). Firstly, a spectral vector correlation coefficient-based k-means clustering algorithm is employed to generate clustering map. Afterwards, an adaptive band selection strategy based on inter-spectral correlation coefficient is adopted to select the reference bands for each band. Then, an adaptive predictor selection strategy based on clustering map is adopted to select the optimal CRLS predictor for each pixel. In addition, a double snake scan mode is used to further improve the similarity of prediction context, and a recursive average estimation method is used to accelerate the local average calculation. Finally, the prediction residuals are entropy encoded by arithmetic encoder. Experiments on the Airborne Visible Infrared Imaging Spectrometer (AVIRIS) 2006 data set show that the CRLS-ABS-APS achieves average bit rates of 3.28 bpp, 5.55 bpp and 2.39 bpp on the three subsets, respectively. The results indicate that the CRLS-ABS-APS effectively improves the compression effect with lower computation complexity, and outperforms to the current state-of-the-art methods.

Performance Improvement of an Energy Efficient Cluster Management Based on Autonomous Learning (자율학습기반의 에너지 효율적인 클러스터 관리에서의 성능 개선)

  • Cho, Sungchul;Chung, Kyusik
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.4 no.11
    • /
    • pp.369-382
    • /
    • 2015
  • Energy aware server clusters aim to reduce power consumption at maximum while keeping QoS(quality of service) compared to energy non-aware server clusters. They adjust the power mode of each server in a fixed or variable time interval to activate only the minimum number of servers needed to handle current user requests. Previous studies on energy aware server cluster put efforts to reduce power consumption or heat dissipation, but they do not consider energy efficiency well. In this paper, we propose an energy efficient cluster management method to improve not only performance per watt but also QoS of the existing server power mode control method based on autonomous learning. Our proposed method is to adjust server power mode based on a hybrid approach of autonomous learning method with multi level thresholds and power consumption prediction method. Autonomous learning method with multi level thresholds is applied under normal load situation whereas power consumption prediction method is applied under abnormal load situation. The decision on whether current load is normal or abnormal depends on the ratio of the number of current user requests over the average number of user requests during recent past few minutes. Also, a dynamic shutdown method is additionally applied to shorten the time delay to make servers off. We performed experiments with a cluster of 16 servers using three different kinds of load patterns. The multi-threshold based learning method with prediction and dynamic shutdown shows the best result in terms of normalized QoS and performance per watt (valid responses). For banking load pattern, real load pattern, and virtual load pattern, the numbers of good response per watt in the proposed method increase by 1.66%, 2.9% and 3.84%, respectively, whereas QoS in the proposed method increase by 0.45%, 1.33% and 8.82%, respectively, compared to those in the existing autonomous learning method with single level threshold.

A Study on the Operational Characteristics of PFC at Instantaneous Power Interrupt (순시 정전 시 역률 개선 회로의 동작 특성에 관한 연구)

  • 이해돈;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.390-396
    • /
    • 2004
  • Recently, there have been Increasing demands for high power factor and low harmonic distortion in the current drawn from utility. The harmonic limits imposed by international standards. It need the PFC techniques in order to reduce line current harmonics and comply with the standards. The average current control method that is the most proper PFC control method in a switching power supply of middle and high power has been used mostly to PFC control method. However, the switching device of PFC circuit has frequently destructed at power return after instantaneous power interrupt. Therefore, this paper have verified the cause of this problems and proposed the solution through simulation and experiment

pH-mediated Regulation of Pacemaker Activity in Cultured Interstitial Cells of Cajal

  • Kim, Byung-Joo;Lee, Jae-Hwa;So, In-Suk;Kim, Ki-Whan
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.10 no.1
    • /
    • pp.7-11
    • /
    • 2006
  • Interstitial cells of Cajal (ICCs) are pacemakers in gastrointestinal tracts, regulating rhythmicity by activating nonselective cation channels (NSCCs). In the present study, we investigated the general characteristics and pH-mediated regulation of pacemaker activity in cultured interstitial cells of Cajal. Under voltage clamp mode and at the holding potential of -60 mV, the I-V relationships and difference current showed that there was no reversal potential and voltage-independent inward current. Also, when the holding potentials were changed from +20 mV to -80 mV with intervals of 20 mV, there was little difference in inward current. In pacemaker activity, the resting membrane potential (RMP) was depolarized (In pH 5.5, $23{\pm}1.5$ mV depolarized) and the amplitude was decreased by a decrease of the extracellular pH. However, in case of increase of extracellular pH, the RMP was slightly hyperpolarized and the amplitude was decreased a little. The melastatin type transient receptor potential (TRPM) channel 7 has been suggested to be required for intestinal pacemaking activity. TRPM7 produced large outward currents and small inward currents by voltage ramps, ranging from +100 to -100 mV from a holding potential of -60 mV. The inward current of TRPM7 was dramatically increased by a decrease in the extracellular pH. At pH 4.0, the average inward current amplitude measured at -100 mV was increased by about 7 fold, compared with the current amplitude at pH 7.4. Changes in the outward current (measured at +100 mV) were much smaller than those of the inward current. These results indicate that the resting membrane potential of pacemaking activity might be depolarized by external acidic pH through TRPM7 that is required for intestinal pacemaking activity.