• Title/Summary/Keyword: Average Capacity

Search Result 1,631, Processing Time 0.025 seconds

Cancer survivor's dietary safety management awareness and competency type (암 생존자의 식생활 안전관리 인식과 역량 유형)

  • Kim, Yun Hwa
    • Journal of Nutrition and Health
    • /
    • v.53 no.5
    • /
    • pp.532-546
    • /
    • 2020
  • Purpose: Although the number of cancer survivors is increasing because of early diagnosis and better treatment, they are worried about relapses and metastasis. This study examined the dietary safety management awareness, capacity, and behavior of cancer survivors. Methods: Data were collected from 233 cancer survivors in Daegu and Gyeongbuk areas using a self-administered 5-Likert questionnaire from March to May 2018. Frequency analysis, one-way analysis of variance, factor analysis, reliability analysis, and correlation analysis were analyzed using the SPSS. Results: The average score for each factor was as follows: importance of weight management (3.83), education requirement (3.79), unhealthy diet (reverse, 3.64), food safety anxiety (3.34), lack of awareness of over and malnutrition (reverse, 3.26), obsession (3.23), cooking capacity (3.16), health-function pursuit (3.04), balanced diet (2.93), and chronic disease anxiety (2.64). The average dietary safety competency factors were significantly lower among the male survivors, aged 60-80 years, lower economic condition, and less nutritional supplement intake. Female survivors comprised the highest proportion with high health management and cooking capacity, while men had the lowest of all the factors (p < 0.001). The group that was low in all three capacity factors had a significantly lower average score of difficulty in acquiring knowledge (reverse), lack of awareness of over- and malnutrition (reverse), importance of weight management, education requirement, knowledge, balanced diet, and health-functional pursuit compared to the other groups (p < 0.001). Conclusion: To effectively manage health, dietary safety management education should be differentiated and actively conducted according to sex, age, cancer diagnosis time, economic status, nutritional supplement intake, and the capacity cluster of cancer survivors.

Studies on Physicochemical and Biological Properties of Depolymerized Alginate from Sea tangle, Laminaria japonicus by Thermal Decomposition -2. Changes in Antimutagenicity Effects and Cholesterol, Glucose and Cadmium(Cd) Binding Capacity of Depolymerized- (다시마(Laminaria japonicaus) Alginate의 가열가수분해에 따른 물리${\cdot}$화학적 및 생물학적 특성에 관한 연구 -2. 저분자 alginate의 항돌연변이효과와 Cholesterol, Glucose 및 카드뮴(Cd) 결합능의 변화-)

  • KIM Yuck-Yong;LEE Keun-Woo;KIM Geon-Bae;CHO Young Je
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.33 no.5
    • /
    • pp.388-392
    • /
    • 2000
  • To improve functionality and characteristics of alginate from the sea tangle, Laminaria japonicus, partially depolymerized alginates (HAG-10, average molecular weight 10,000; HAG-50, average molecular weight 50,000; HAG-100, average molecular weight 100,000) were obtained with hydrolysis of alginate by heating at $12^{\circ}C$. Effects of the depolymerization on physicochemical properties were investigated in the antimutagenicity and binding capacity of cholesterol, glucose and cadmium. In the Ames mutagenicity test using Salmonella typhimurium TA 100, HAG-10, HAG-50, HAG-100 and intact alginate reduced effectively the mutagenicities induced by aflatoxin $B_1 (AFB_1)$ and N-methyl-N'-nitro-N-nitrosoguanidine(MNNG) and HAG-10 showed the strongest antimutagenicity among the tested samples. The binding capacity of cholesterol, glucose and cadmium at different pH in vitro depended highly on molecular weight of alginate, and the changes in binding capacity at different pH was not different.

  • PDF

Storm-Water CSOs for Reservoir System Designs in Urban Area (도시유역 저류형 시스템 설계를 위한 CSOs 산정)

  • Jo, Deok-Jun;Kim, Myoung-Su;Lee, Jung-Ho;Park, Moo-Jong;Kim, Joong-Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1199-1203
    • /
    • 2005
  • Combined sewer overflows(CSOs) are themselves a significant source of water pollution. Therefore, the control of urban drainage for CSOs reduction and receiving water quality protection is needed. Examples in combined sewer systems include downstream storage facilities that detain runoff during periods of high flow and allow the detained water to be conveyed by an interceptor sewer to a centralized treatment plant during periods of low flow. The design of such facilities as stormwater detention storage is highly dependant on the temporal variability of storage capacity available(which is influenced by the duration of interevent dry periods) as well as the infiltration capacity of soil and recovery of depression storage. As a result, a contiunous approach is required to adequately size such facilities. This study for the continuous long-term analysis of urban dranage system used analytical Probabilistic model based on derived probability distribution theory. As an alternative to the modeling of urban drainage system for planning or screening level analysis of runoff control alternatives, this model have evolved that offer much ease and flexibility in terms of computation while considering long-term meteorology. This study presented rainfall and runoff characteristics or the subject area using analytical Probabilistic model. Runoff characteristics manifasted the unique characteristics of the subject area with the infiltration capacity of soil and recovery of depression storage and was examined appropriately by sensitivity analysis. This study presented the average annual COSs and number of COSs when the interceptor capacity is in the range 3xDWF(dry weather flow). Also, calculated the average annual mass of pollutant lost in CSOs using Event Mean Concentration. Finally, this study presented a dicision of storage volume for CSOs reduction and water quality protection.

  • PDF

A Case Study of Monitored Natural Attenuation at a Military Site Contaminated by Petroleum Hydrocarbon in Korea (국내 유류오염 군부지 내 자연저감기법 적용 사례 연구)

  • Lee, Hwan;Kang, Seonhong
    • Journal of Environmental Impact Assessment
    • /
    • v.25 no.5
    • /
    • pp.333-344
    • /
    • 2016
  • In this study, the efficiency of natural attenuation was evaluated through the hydrogeological characteristics such as monitoring and analyses, tracer tests, chemical composition analysis of the groundwater at a military site contaminated by petroleum hydrocarbon in korea. Also, based on the results, the natural attenuation rate by distance and the expressed biodegradation capacity(EBC) was evaluated. The regression slope of -0.0248($K/V_x$) and bulk attenuation rate of $1.7{\times}10^{-3}/day$ were calculated respectively. The range of total expressed biodegradation capacity(EBC) of BTEX was shown from 9.1 mg/L to 10.0 mg/L(average 9.7 mg/L). It was confirmed that the denitrification which was expressed about 63.6% in the total EBC is the largest influence redox process. Consequently, the biodegradation capacity is considered to be sufficient for remediation in the BTEX average concentration of 1.326 mg/L.

On the Capacity for the Secondary User with Primary Full Duplex Relay Network in Spectrum Sharing Systems (주파수 공유 시스템에서 일차 사용자가 양방향 중계기를 사용할 때의 이차 사용자의 통신 용량 분석)

  • Kim, Hyung-Jong;Hong, Dae-Sik
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.8
    • /
    • pp.39-45
    • /
    • 2012
  • This paper investigates the capacity for the secondary user with the primary full duplex relay (FDR) network in spectrum sharing systems. For sharing the spectrum of the primary user, sharing scheme under the various primary network should be investigated. However, the conventional works only consider the point-to-point primary communication system. When the FDR node is used for the primary networks, both primary relay and destination suffer the interference from the secondary transmitter simultaneously. Thus, the strict interference constraint should be considered to share the spectrum of the primary user. Therefore, we investigate the capacity of the secondary user with the primary FDR network under the average and peak received-power constraints. In addition, we analyze the performance degradation by the selection of the worst interference channels to consider interference constraint in this system. Through the numerical results, the capacities of the primary and secondary users under the average received-power is superior to the that under the peak received-power constraint.

Analysis of the Korean Filatures Management (우리나라 제사공장의 경영분석)

  • 최병희;남중희
    • Journal of Sericultural and Entomological Science
    • /
    • v.10
    • /
    • pp.99-105
    • /
    • 1969
  • The results of investigation and management analysis for the silk filatures in Korea until 1968 are evaluated as followings. (1) The average cocoon purchasing amount for a filature was found as 10,800kg and they are processed 105kg per man on the cocoon assorting process, 8,683kg per day during the drying process of which 42 percent are dried with low temperature drying system. (2) The average cocoon cooking capacity is 50 g, cocoon per minute, but the cooking capacity per man is smaller in case of larger factory. (3) The silk production capacity per month per a filature is 6,000kg and the amount gets smaller in case of larger factory. (4) The employee cost per one kg of raw silk production was found as high in smaller factory and it was found that 200~300 sets size was the optimum capacity for operation. (5) In case of multiends silk reeling machine, the employee cost for the silk reeling process acts as the most peculier factor among six different cocoon processes and it is reached to conclued to deduct the number of employees for this process in order to deduct the production cost. (6) The correlation coefficients between cost factors and total labour cost was found as 46 percent, therefore the rest (54%) will be the production cost other than labour cost.

  • PDF

Partial CSI-Based Cooperative Power Allocation in Multi-Cell Dual-Hop MISO Relay Systems (다중-셀 이중-홉 MISO 릴레이 시스템에서 부분 채널 정보를 이용한 협력 전력 할당 기법)

  • Cho, Hee-Nam;Kim, Ah-Young;Lee, Jin-Woo;Lee, Young-Hwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.9C
    • /
    • pp.887-895
    • /
    • 2009
  • This paper proposes a cooperative power allocation with the use of partial channel information (e.g., the average signal-to-noise ratio (SNR) and transmit correlation) in multi-cell dual-hop multi-input single-output (MISO) relay systems. In a dual-hop MISO relay channel, it is desirable to allocate the transmit power between dual-hop links to maximize the end-to-end capacity. We consider the maximization of the end-to-end capacity of a dual-hop MISO relay channel under sum-power constraint. The proposed scheme adaptively allocates the transmit power considering the average channel gain of the target relay and the transmit correlation of the desired and inter-relay interference channel from adjacent relays. It is shown by means of upper-bound analysis that the end-to-end capacity can be maximized by making the angle difference of the principal eigenvectors of the desired and inter-relay interference channel orthogonal in highly-correlated channel environments. Finally, the performance of the proposed scheme is verified by computer simulation.

Estimation of Storage Capacity for CSOs Storage System in Urban Area (도시유역 CSOs 처리를 위한 저류형시스템 설계용량 산정)

  • Jo, Deok Jun;Lee, Jung Ho;Kim, Myoung Su;Kim, Joong Hoon;Park, Moo Jong
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.490-497
    • /
    • 2007
  • A Combined sewer overflows (CSOs) are themselves a significant source of water pollution. Therefore, the control of urban drainage for CSOs reduction and receiving water quality protection is needed. Examples in combined sewer systems include downstream storage facilities that detain runoff during periods of high flow and allow the detained water to be conveyed by an interceptor sewer to a centralized treatment plant during periods of low flow. The design of such facilities as stormwater detention storage is highly dependant on the temporal variability of storage capacity available (which is influenced by the duration of interevent dry periods) as well as the infiltration capacity of soil and recovery of depression storage. As a result, a continuous approach is required to adequately size such facilities. This study for the continuous long-term analysis of urban drainage system used analytical probabilistic model based on derived probability distribution theory. As an alternative to the modeling of urban drainage system for planning or screening level analysis of runoff control alternatives, this model have evolved that offer much ease and flexibility in terms of computation while considering long-term meteorology. This study presented rainfall and runoff characteristics of the subject area using analytical probabilistic model. This study presented the average annual COSs and number of COSs when the interceptor capacity is in the range $3{\times}DWF$ (dry weather flow). Also, calculated the average annual mass of pollutant lost in CSOs using Event Mean Concentration. Finally, this study presented a decision of storage volume for CSOs reduction and water quality protection.

Effect of CPR Foundation Reinforcement Assessed by Compressive Loading Tests (CPR 공법의 압축재하시험을 통한 기초지반의 보강효과)

  • Kang, Seong-Seung;Kim, Jung-Han;Noh, Jeongdu;Ko, Chin-Surk
    • The Journal of Engineering Geology
    • /
    • v.29 no.3
    • /
    • pp.211-222
    • /
    • 2019
  • This study evaluates the yield load and allowable bearing capacity of ground in compressive loading tests to confirm the effect of CPR foundation reinforcement. The average compressive strength of the injection materials was higher than the planned compressive strength. Standard penetration tests for each stratum showed that foundation reinforcement improved the average N values, thereby increasing the bearing capacity of the ground. Compressive loading tests on two CPR piles revealed that the total and net settlement due to the maximum load exceed that permissible for the CPR pile diameter. The yield load and allowable bearing capacity calculated by the settlement criterion and the load-settlement curves varied greatly with the method applied. Therefore, it seems to be necessary to determine the optimum value through comprehensive analysis after applying various yield load calculation methods.

Relationship between Saliva Factors Measured Using the SILL-Ha Saliva Test System and Blood Cell Counts according to Perceived Stress Scale Scores in Female College Students

  • Lee, Sun-Mi;Jung, Eun-Ha;Jun, Mi-Kyoung
    • Journal of dental hygiene science
    • /
    • v.21 no.3
    • /
    • pp.150-157
    • /
    • 2021
  • Background: Stress as a cause of mental health problems is known to be more prevalent in women than in men and has a negative effect on several aspects of physical health, such as the composition of blood and saliva. This study investigated the relationship of perceived stress with blood cell counts, saliva flow rate, and saliva factors. Methods: We recruited women in their 20s with a high prevalence of stress. Stress was evaluated using the Korean version of the perceived stress scale. Blood tests included white blood cell, hemoglobin, and platelet. We then examined the saliva flow rate and cariogenic bacteria level, acidity, occult blood, buffer capacity, leukocyte level, protein level, and ammonia level using rinse water with the SILL-Ha saliva test system. Results: In a total of 70 participants, the average age was 21.64 years old, the average perceived stress score was 16.96±4.32, and high levels of stress were reported by 80% of the participants (n=56). The high-stress group had lower hemoglobin levels. In addition, the high-stress group showed a lower saliva flow rate than the low-stress group, and there was a difference in the salivary acidity and buffer capacity. The total perceived stress score showed a positive correlation with acidity and negative correlation with buffer capacity and the hemoglobin level. Conclusion: This study found that stress in female college students might affect the composition of blood and saliva. High levels of stress were positively correlated with the hemoglobin level, saliva flow rate, and acidity and negatively correlated with the buffer capacity.