• Title/Summary/Keyword: Available Safety Egress Time (ASET)

검색결과 15건 처리시간 0.024초

목재연소시의 실내화재성상과 안전대피시간 (Fire Growth of Wood Cribs and Available Safe Egress Time)

  • 정길순;태순호;이병곤
    • 한국안전학회지
    • /
    • 제8권2호
    • /
    • pp.72-77
    • /
    • 1993
  • Available Safe Egress Time(ASET) is the time available for occupants to evacuate safely In compartment fire, and It depends on the time of fire detection and hazardous conditions. The purpose of thls study Is to provide an analytical basis and experimental data for estimating the fire growth in compartments and the available safe egress time, and to compare the experimental data with those proposed equations. As a result, hazard order Is poison to CO, descent of smoke layer, poison to $CO_2$, burn to hot smoke layer, and lack of $O_2$, ASET is lengthened in this order. Also, The more fire load is increased, the more ASET is shorted.

  • PDF

피난유도자 수와 배연설비를 고려한 요양병원의 피난안전성 평가 (Egress Safety of Nursing Hospital Considering Egress Guides and Smoke Exhaust System)

  • 최승호;할리오나;허인욱;김강수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권3호
    • /
    • pp.64-71
    • /
    • 2022
  • 이 연구에서는 요양병원의 피난안전성을 평가하기 위한 해석적 연구를 수행하였다. Fire Dynamics Simulator (FDS)를 활용하여 배연설비 유무을 변수로 화재 시뮬레이션을 수행하였으며, 요양병원의 피난허용시간을 산정하였다. 또한 Pathfinder를 활용하여 재실자의 특성과 피난지연시간을 고려한 요양병원의 피난 시뮬레이션을 수행하였으며, 피난요구시간을 산정하였다. 피난허용시간과 피난요구시간을 비교함으로써 피난유도자수, 피난지연시간, 배연설비 유무에 따른 요양병원의 피난안전성을 평가하였다. 시뮬레이션 결과에 따르면 피난지연 시간이 증가함에 따라 사상자의 수가 증가하였으며, 피난유도자의 수가 증가할수록 피난요구시간이 감소하는 것으로 나타났다. 또한 KFPA에서 제시하는 용량을 갖춘 배연설비가 확보된 경우 피난허용시간을 크게 늘릴 수 있으며, 사상자의 수도 크게 감소시킬 수 있는 것으로 나타났다.

Evacuation Safety Evaluation of High School according to Hydrogen Fluoride Leakage

  • Boohyun Baek;Sanghun Han;Hasung Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제16권2호
    • /
    • pp.255-266
    • /
    • 2024
  • The purpose is to evaluate evacuation safety by simulating the toxic effects of hydrogen fluoride leaks in areas surrounding national industrial complexes and to suggest alternatives for areas that do not satisfy evacuation safety. For human casualties caused by hydrogen fluoride leakage accidents, Available Safe Egress Time (ASET) is calculated by the toxic effects quantified with the Areal Locations of Hazardous Atmospheres (ALOHA), an off-site consequence assessment program. The Required Safe Egress Time (RSET) is calculated through Pathfinder, an evacuation simulation program. Evacuation safety is assessed by comparing ASET and RSET. The ALOHA program was used to evaluate the time to reach AEGL-2 concentration in 12 scenarios. The Pathfinder program was used to assess the total evacuation time of the high school among specific fire-fighting objects. Of the 12 accident scenarios, ASET was larger than RSET in the worst-case scenarios 1 and 9. For the remaining 10 accident scenarios, the ASET is smaller than the RSET, so we found that evacuation safety is not guaranteed, and countermeasures are required. Since evacuation safety is not satisfactory, we proposed to set up an evacuation area equipped with positive pressure equipment and air respirators inside specific fire-fighting objects such as the high school.

화재시뮬레이션에서 입력변수 및 모델 불확실도가 고려된 허용피난시간(ASET)에 관한 연구 (Study on the Available Safe Egress Time (ASET) Considering the Input Parameters and Model Uncertainties in Fire Simulation)

  • 한호식;황철홍
    • 한국화재소방학회논문지
    • /
    • 제33권3호
    • /
    • pp.112-120
    • /
    • 2019
  • 국내 PBD에서 화재시뮬레이션을 이용한 안전성 평가의 신뢰성을 개선시키기 위하여, 화재시뮬레이션의 입력변수 및 수치모델의 불확실도가 고려된 ASET의 평가방법에 대한 검토가 수행되었다. 이를 위해 영화관 및 오피스텔이 검토 대상으로 선정되었다. 주요 결과는 다음과 같다. 인명안전기준에 제시된 주요 물리량에 가장 큰 영향을 미치는 열발생률의 불확실도를 고려할 때, 온도, CO 및 가시도의 상당한 변화가 발생됨을 확인하였다. 또한 수치모델의 불확실도를 반영한 편향인자를 고려할 때, 온도 및 CO는 큰 변화가 없으나 FDS의 낮은 연기농도 예측성능으로 인하여 가시도는 크게 증가됨을 알 수 있었다. 마지막으로 국내 PBD에서 ASET이 대부분 가시도에 의해 결정되는 원인이 논의되었으며, 정확한 ASET 평가를 위해 화재시뮬레이션의 입력변수 및 수치모델의 불확실도 적용 방안이 제안되었다.

환경에너지 시설내 화재 및 피난해석 (Fire and Evacuation Analysis in Environmental Energy Facilities)

  • 전용한;김종윤
    • 한국화재소방학회논문지
    • /
    • 제33권3호
    • /
    • pp.84-90
    • /
    • 2019
  • 본 연구에서는 환경에너지 시설내 전자기기실 내부의 화재 및 피난을 수치적 해석 방법을 통해 실시하고 평가하였다. 화재 시뮬레이션은 FDS을 이용하여 가시거리, 온도분포, CO의 농도분포 등을 분석하였다. 그 결과를 토대로 피난시뮬레이션인 Pathfinder프로그램을 사용하여, 재실자들의 피난시간을 계산하였으며 피난안전성 평가를 도출하였다. 그 결과 전자기기실 내부의 피난 허용시간은 P-01에서 203.3 s로 가장 단시간 내에 대피가 요구되었으며, P-05에서 398.6 s로 피난 허용시간이 가장 큰 값을 나타내었다. 피난 소요시간 분석 결과 모든 지점에서 모든 재실 인원이 대피가 이루어져 대피자의 안전성이 확보되는 것으로 판단되었다. 특히 이 시뮬레이션의 결과는 피난안전성능을 높이기 위하여 소방설비가 작동하지 않는 경우를 고려한 것으로서 실제 화재 발생 시 소방설비가 작동된다면 보다 우수한 안전을 확보할 수 있을 것으로 사료된다.

고등학교 복도 보행 장애물이 피난 안전성에 미치는 영향 (Effects of High School Corridor Walking Obstacles on Evacuation Safety)

  • 이순범
    • 한국안전학회지
    • /
    • 제38권2호
    • /
    • pp.112-119
    • /
    • 2023
  • This study analyzes the effects of personal lockers, drinking fountains, and all-in-one shutters (hereinafter referred to as "corridor walking obstacles") on evacuation safety to suggest the necessity of operating a more effective educational facility safety certification system. To achieve this purpose, the five-story high school building with the obstacles installed in the corridor has been chosen, and evacuation tests through the Pathfinder Simulation Program have been carried out. When the evacuation exit is designated in the current state, where the students are placed on the 2nd, 3rd, and 4th floors and the corridor walking obstacles are applied as a variable, the required safe egress time (RSET) is 322 seconds. This can lead to dangerous results in the event of a disaster by exceeding the available safe egress time (ASET) standard of 240 seconds by 82 seconds. When students are placed on the 1st, 2nd, and 3rd floors under the same conditions, the RSET is 214.5 seconds, 25.5 seconds lower than the ASET standard, indicating that it is effective in reducing the impact of walking obstacles on evacuation time. The safety management plan for walking obstacles in the corridors is discussed, considering the special characteristics of the school corridors. The results of this study can be used as the necessary data for optimizing evacuation routes in corridors and creating a safe, educational environment.

Performance-based Fire Protection Design of Domestic Super High-rise Buildings - Evaluation by ASET and RSET -

  • Roh, Hyeong-Ki
    • 한국방재학회 논문집
    • /
    • 제11권2호
    • /
    • pp.9-13
    • /
    • 2011
  • 초고층 빌딩 건설 시 요구되는 성능위주 소방설계는 인명 안전을 확보할 수 있는 능동적인 대책으로서 화재 위험성을 평가하고, 공학적 분석 결과를 토대로 하여 방재시스템을 구축하는 것으로 관련 법규 및 기준을 적용하여 수행하는 기존의 설계 방식보다 인명 안전의 확보에 있어서 매우 효율적이고 타당하다고 보여진다. 본 연구는 피난 요구 시간인 RSET과 피난이 가능한 시간인 ASET에 의한Time-line Analysis을 적용하였으며 또한 ASET과 RSET을 비교, 분석하기 위하여 화재 및 피난 시뮬레이션을 수행하였다. 연구 결과, 스프링클러설비가ASET을 증가시켰으며, 화재감지 및 경보시간의 단축이 RSET을 효과적으로 감소시켜 주고 있다. 단축된 시간은 인명의 안전을 확보하는데 많은 영향을 미치는 것으로 확인되었다. 또한 소화설비, 화재 감지 및 경보설비가 정상적으로 작동되도록 유지 관리되는 것도 중요한 것으로 파악되었다. 화재의 성상을 데이터 베이스화하고 피난 대응 프로그램 등이 구축되면 성능위주 설계에 유용한 자료로 이용될 수 있다.

CFD기반 화재 대피 시뮬레이션 모델을 적용한 위험도 평가 분석 -인천터미널역 역사를 대상으로 (Risk Evaluation and Analysis on Simulation Model of Fire Evacuation based on CFD - Focusing on Incheon Bus Terminal Station)

  • 김민규;주용진;박수홍
    • Spatial Information Research
    • /
    • 제21권6호
    • /
    • pp.43-55
    • /
    • 2013
  • 최근 실내 공간에서의 재난, 화재와 테러 등 대피상황을 재현하여 이를 가시화하기 위한 연구가 주목 받고 있으며, 실내 공간에 대한 모델을 설계하고 인명 안전 평가를 통한 신뢰성 있는 분석이 요구되고 있다. 이에 본 연구에서는 실제적인 건물 화재 위험 요인을 고려하여 피난 안전성 분석과 피난 경로 안내가 가능한 시뮬레이션 모델을 개발하고자 하였다. 이를 위해 인천터미널역 역사를 대상으로 3차원 화재 및 피난 모델을 설계하고, 실내 내장재의 재질을 바탕으로 열 매개변수와 화재 인지 장치를 이용하여 화재 위험 분석을 수행하였다. 둘째, 인명안전을 위한 평가에 있어 화재 시뮬레이션인 FDS(Fire Dynamics Simulator)와 피난 시뮬레이션을 통해 재실자가 인체에 손상 없이 견딜 수 있는 피난허용시간(ASET: Available Safe Egress Time)을 산출하였다. 또한 화재를 감지하고 안전한 장소까지 완전하게 피난하는데 소요되는 피난요구시간(RSET: Required Safe Egress Time)을 계산하고 이를 비교 분석하였다. 결과적으로 연구대상의 3차원 공간적인 정보를 기반으로 한 실내 공간 모델과, 고시된 안전기준을 반영한 열차 내 화재 및 피난 위험도 측정 시뮬레이션 분석을 통해 보다 실제적인 안전성 평가를 수행 할 수 있었다.

화원면적 변화에 따른 격자 크기 의존도 및 예측결과 분석 (Analysis of Prediction Results and Grid Size Dependence According to Changes in Fire Area)

  • 윤홍석;황철홍
    • 한국화재소방학회논문지
    • /
    • 제33권6호
    • /
    • pp.9-19
    • /
    • 2019
  • 건축물의 화재안전성평가를 위한 화재시뮬레이션에서 화원면적 및 격자크기의 변화는 예측결과에 큰 영향을 미칠 수 있다. 따라서 동일한 최대 열발생률을 갖는 화원의 면적 변화가 구획화재의 예측결과에 미치는 영향이 검토되었으며, 동일한 화원면적의 조건에서 격자크기에 대한 예측결과의 의존도가 동시에 검토되었다. 주요 결과로서, 특성화재직경을 기준으로 6개 이상의 격자가 삽입되면 화원면적이 변화되더라도 격자크기는 화재의 열 및 화학적 특성에 큰 영향을 미치지 않았다. 또한 화원면적의 변화는 구획 내부에서 허용피난시간(ASET)과 관련된 주요 물리량의 예측결과에 상당한 차이를 야기하였다. 그러나 개구부를 기준으로 일정 거리 이상의 구획외부에서는 화원면적의 변화가 전반적 화재특성에 미치는 영향이 크지 않음이 확인되었다.

노인의료복지시설 화재 시 와상노인의 피난안전성 제고를 위한 피난허용시간 연장과 소방기관으로의 통보시간 연구 (A Study on ASET Elongation & Notification Time to Fire Stations for the Escape Safety of Aged Bedridden Patients in Elderly Long-term Medical Care)

  • 박형주;이영재
    • 한국화재소방학회논문지
    • /
    • 제32권4호
    • /
    • pp.50-59
    • /
    • 2018
  • 고령화 추세에 따라 최근 급속히 증가하고 있는 노인복지시설에서 화재가 빈번하게 발생하고 있으나, 거주하고 있는 와상노인에 대한 피난안전성이 확보되어 있지 않아 대규모 인명피해를 초래하고 있다. 이런 시설에 거주하는 와상노인에 대한 피난안전성의 실효성을 제고하기 위한 방법의 일환으로 비화재구역의 피난허용시간을 최대한 연장시키면서 발코니 등의 일시피난안전구역에 차례로 피난시키고, 소방기관에 통보하는 화재속보설비를 통해 소방대의 출동에 의한 외부 조력피난유도방법이 최선의 대책인 것으로 판명되었다. 따라서 이와 같은 조력피난을 수행하는데 있어 반드시 적용해야할 요소기술을 방화 소방공학적으로 개발하여 4가지로 분류 제시하였다. 방화공학적 요소기술로는 구조 구획의 내화성능확보와 구획의 소규모화 규제 조항과 마감재의 난연 불연성능의 확보 규제 조항인 2가지를 제시하였다. 또한 소방공학적 요소기술로는 스프링클러에 의한 냉각효과 부과 규제 조항과 소방기관으로의 자동화재속보기능의 부여 규제 조항인 2가지를 제시하였다. 제시된 규제 조항에 대하여 일본과 국내의 법조문을 상세히 비교분석하여 국내에서 개정한 법조문상 미흡한 부분을 고찰하고, 국내의 노인복지시설의 피난안전성의 제고를 위해 시급하게 개선되어야 할 안전기준 개정(안)을 제시하였다.