• Title/Summary/Keyword: Automatic recording system

Search Result 55, Processing Time 0.036 seconds

A Personal Videocasting System with Intelligent TV Browsing for a Practical Video Application Environment

  • Kim, Sang-Kyun;Jeong, Jin-Guk;Kim, Hyoung-Gook;Chung, Min-Gyo
    • ETRI Journal
    • /
    • v.31 no.1
    • /
    • pp.10-20
    • /
    • 2009
  • In this paper, a video broadcasting system between a home-server-type device and a mobile device is proposed. The home-server-type device can automatically extract semantic information from video contents, such as news, a soccer match, and a baseball game. The indexing results are utilized to convert the original video contents to a digested or arranged format. From the mobile device, a user can make recording requests to the home-server-type devices and can then watch and navigate recorded video contents in a digested form. The novelty of this study is the actual implementation of the proposed system by combining the actual IT environment that is available with indexing algorithms. The implementation of the system is demonstrated along with experimental results of the automatic video indexing algorithms. The overall performance of the developed system is compared with existing state-of-the-art personal video recording products.

  • PDF

A New Design of an ATF Block for DVCRs (DVCR용 ATF(Automatic Track Following) 블록의 새로운 설계)

  • Cho, Seong-Il;Kim, Sung-Wook;Ha, In-Joong;Kim, Jeong-Tae;Na, Il-Ju
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.8
    • /
    • pp.106-112
    • /
    • 1998
  • Recently, the amount of image and audio data has been increasing dramatically for high performance. According to this trend, a high-density magnetic recording system is necessitated and the tracks of magnetic tapes are getting narrower. This, in turn, requires the capstan servo system of the magnetic recording system such as DVCR to control precisely the speed and position of the capstan motor. Especially, in case of play-back, the capstan servo system should be able to position and maintain the head on the desired place of the track. To meet this requirement, digital camcorders use ATF (Automatic Track Following). In this paper, a new ATF block using discrete Fourier transform is proposed. The proposed ATF block was designed and implemented in ALTERA FPGA chips and fully tested in a real DVCR system. It is shown through experiments that the new ATF block is more cost-effective than other existing ATF blocks using digital lowpass filters. In particular, the number of logic gates can be reduced by 20% in average, compared to the existing ATF's.

  • PDF

Quantitative analysis of oculomotor system by automatic identification algorithm (자동판별 알고리즘에 의한 동안계의 정량적인 해석)

  • 장인호;이세현;박상희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.637-640
    • /
    • 1986
  • The design and use of a micro-computer-based system for quantitative study of ocular kinetics are described. An algorithm for microcomputer analysis of electro-oculographically recorded saccadic eye movement is presented. From a brief, 4-min recording session detailed statistical information about saccade amplitude, duration, and velocity can be obtained. Since this data is not significantly altered by practice of motivational factors, it provides a sensitive functional test of the oculomotor system and its brain control system.

  • PDF

Quantitative Analysis of Oculomotor System by Automatic Identification Algorithm (자동 판별 알고리즘에 의한 동안계의 정량적인 해석)

  • 장인호;이세현
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.151-158
    • /
    • 1986
  • In this paper, the design and implementation of a microcomputer-based measuring system for quantitative analysis of oculomotor system are described. An algorithm for microcomputer analysis of electro-oculographicaay recorded horizontal saccadic eye movements is presented. From a brief, 4-min recording session detailed statistical information about saccade amplitude, duration, and velocity can be obtained.

  • PDF

Automatic Switching System for The Impedance Analysis of Multichannel icroelectrode Arrays: Limits and Improvement Scheme (다채널 미세전극칩 임피던스 분석을 위한 자동 스위칭 시스템: 한계점 및 개선 방안)

  • Lee, Seok-Young;Nam, Yoon-Key
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.207-217
    • /
    • 2011
  • Electrode impedances are measured to quantitatively characterize the electrode-electrolyte or cell-electrode interfaces. In the case of high-density microelectrode arrays(MEAs) that have been developed for brainmachine interface applications, the characterization process becomes a repeating and time-consuming task; a system that can perform the measurement and analysis in an automated fashion with accuracy and speed is required. However, due to the large number of channels, parasitic capacitance and off-capacitance components of the switching system become the major factors that decreased the accuracy for the measurement of high impedance microelectrodes. Here we investigated the implementation of automatic impedance measurement system with analyzing the causes of possible measurement-related problems in multichannel switching configuration. Based on our multi-channel measurement circuit model, we suggest solutions to the problems and introduce a novel impedance measurement scheme using electro-mechanical relays. The implemented measurement system could measure |Z| < 700 $k{\Omega}$ of impedance in - 10% errors, which can be widely applicable to high density neural recording MEAs.

Automatic Piped Water Meter Reading System Based on IEEE 802.15.4 Protocol (IEEE 802.15.4 Protocol 기반 원격 수도검침 System)

  • Seon, Yong-Ju;Lee, Ho-Eung;Park, Soo-Jin;Park, Hyun-Ju
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.304-308
    • /
    • 2008
  • In this paper, we present measurement method of the amount of used piped water and the communications environment for automatic piped water meter reading. The existing piped water meter reading which is carried out by the human in person by monitoring the amount of use and recording make the problem of an error of the figure and being short of staffed to carry out piped water meter reading. To solve the existing problem in this paper, the amount of used piped water is converted into data type by Photo Interrupt Sensor, and IEEE 802.15.4 Protocol is used to confirm the measurement in remote place.

  • PDF

A Study on the Significant Point Detection Algorithm and Design of Hardware for Pulse Automatic Diagnosis (맥파자동진단을 위한 하드웨어의 설계 및 특성점 검출 알고리즘에 관한 연구)

  • Lee, J.Y.;Lee, J.W.;Lee, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2255-2258
    • /
    • 1998
  • Method of diagnosis in oriental medicine, the unbalance of the physiological function of the five viscers and six bowels of the human body is determined from time immemorial with the condition of blood circulation which is performed through blood vessels by the vitality of the heart. In oriental medicine, treatment is largely attempted by adjusting this unbalance. The analysis of pulse wave, which mainly measures the changes in blood flows, is to evaluate the shapes of a pulse wave rather than the quantitative changes like rates and strength of the pulse. This paper presents the development of Hardware System and Pulse Diagnosis Algorithm for automatic diagnosis of the pulse wave. This system makes the precise diagnosis and the objective recording possible.

  • PDF

Teleoperate Temperature Calibration via Internet

  • Moonchaisook, Watakarn;Chaikla, Amphawan;Trisuwannawat, Thanit;Tammarungwattana, Narin;Julsereewong, Prasit
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1438-1442
    • /
    • 2003
  • This paper presents the calibration service for the temperature sensor via the Internet. The purpose of the calibration service is to provide the teleoperate calibration procedure without skillful technician requirement at the client site. Besides the automatic measurement equipment that eases the operation, the developed software emphasizes the reliability of operation, simplifying the measurement data recording and processing, and achieving quality of the temperature measurements.

  • PDF

A Study on the N Values Characteristics of Automatic Recording System of SPT (표준관입시험 자동기록장치의 N치 특성 연구)

  • Yoon, Won-Sub;Park, Myeon-Gu;Han, Jae-Woon;Shin, Seoung-Gu;Chae, Young-Su
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1168-1176
    • /
    • 2010
  • Currently drilling investigation and the SPT in parallel not only organization and peculation sincerity quality historian of test to be old the data was abundant with the site ground investigation test which is representative and the research of empirical formula in compliance with many scholar was accomplished and was come. The data which is like this wide is used with geotechnical engineering data of plan and space-time of the field which is various. SPT with tentative voluntary skillful degree record method of variety and technical expert of equipment, according to site conditional is consistent the quality of ground condition but cannot be made to show there is a tendency and specially the point whose is difficult actually accurately to follow the interval which decides in quality as a matter of tentative standard of drill and the test in parallel and a tentative method exists. From the research which sees consequently also the skill of variety and technical expert of equipment of SPT, strong point of the SPT automation logger will be able to complement the problem point of quality etc. of site condition under comparison analyzing should have been boiled about SPT of existing and tentative methods and N-value.

  • PDF