• Title/Summary/Keyword: Automatic measuring system

검색결과 356건 처리시간 0.03초

Automatic Measurement of the Degree of Contamination with Electric Conductivity and Oscillating Frequency (발진주파수 및 전도도를 통한 오손도 자동측정)

  • 최남호;구경완;이명섭;한상옥;정재기
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.153-156
    • /
    • 2000
  • To reduce the maintenance expense, and the possibility of electric outage and accident, we should optimize the outdoor insulation system. And for the optimization, accurate measurement for the degree of contamination with climatic conditions, such as wind, rain, and drought, should be carried. However the classical measuring method, brush wiping, has some problems in the aspect of man power, reliability, and expense. In this paper, we propose two type apparatus, which could detect the degree of contamination on insulators in outdoor insulation system, such as transmission and distribution line insulator and bushing. One use the leakage current, and the other use the oscillating frequency to check the degree of contamination. To avoid the oxidation of electrode AC source, and the low degree of contamination was applied. From the result of this investigation we could get the good relationship between the degree of contamination and the leakage current and oscillating frequency

  • PDF

Development of Automatic Hole Position Measurement System using the CCD-camera (CCD-카메라를 이용한 홀 변위 자동측정시스템 개발)

  • 김병규;최재영;강희준;노영식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.127-130
    • /
    • 2004
  • For the quality control of the industrial products, an automatic hole measuring system has been developed. The measurement device allows X-Y movement due to contact forces between a hole and its own circular cone and the device is attached to an industrial robot. Its measurement accuracy is about 0.04mm. This movement of the plate is measured by two LVDT sensor system. But this system using the LVDT sensors is restricted by high cost and precision of measurement and correspondence of environment so particularly, a vision system with CCD-Camera is discussed in this paper for the above mentioned purpose. The device consists of two of two links jointed with hinge pins basically and, they guarantee free movement of the touch prove attached on the second link in the same plane. These links are returned to home position by the spring plungers automatically after each process for the next one. On the surface of the touch prove, it has a circular white mark for camera recognition. The system detect and notify the center coordinate of capture mark image through the image processing. Its measuring accuracy has been proved to be about $\pm$0.01mm through the repeated implementation over 200 times. This technique will shows the advantage of touch-indirect image capture idea using cone-shaped touch prove in various symmetrical shaped holes particulary, like tapped holes, chamfered holes, etc As a result, we attained our object in a view of the accuracy, economical efficiency, and functionality

  • PDF

The realtime measurement of burrs on sheet metal using the semiconductor laser (반도체 레이저를 이용한 박판 버의 실시간 측정)

  • 홍남표;신홍규;김헌영;김병희
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 한국소성가공학회 2003년도 추계학술대회논문집
    • /
    • pp.107-110
    • /
    • 2003
  • The sheet metal shearing process is normally used in the precision elements such as semi-conductor components. In precision elements, burrs usually reduce the quality of machined parts and cause interference, jamming and misalignment during assembly procedures and because of their sharpness, they can be safety hazard to personnel. Furthermore, not only burrs are hard to predict and avoid, but also deburring, the process of removing burrs, is time-consuming and costly. In order to get the burr-free parts, therefore, we developed the precise burr measuring system using the laser. Using the X-Y precious table, we used vertical measuring method. Through the laser measurement system, we gain the minute analog signal, so this signal was amplified by the electric circuit. Finally, we gained the realtime burr data using A/D converter, PC. By introducing the novel laser measuring method which employing vertical measurement mechanism, we could get fast and precious burr data. Through the experiments, the accuracy of the developed system is proved. The burr height measured during the punching process can be used for automatic deburring and in-situ aligning.

  • PDF

Development of Tunnel Convergence Measuring System (터널의 내공변위 계측 시스템 개발)

  • 정성혁;박찬홍;이재기
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 한국GIS학회 2004년도 GIS/RS 공동 춘계학술대회 논문집
    • /
    • pp.607-612
    • /
    • 2004
  • Together with the requirements of tunnels, its construction methods and technologies have been pretty much developed, but frequent accidents happened under the constructions are just one of important problems which should be improved. To detect the potential hazardous factors in or ahead of time, speedy and accurate measurement are absolutely required, but currently surveying method using tapes, level and total station, has been generally taken in measuring of tunnel convergence and crown. The purpose of this study is, as using of 'Industrial photogrammetry' system which is supplying more accuracy and speedy in the measure of tunnel convergence, aimed at promotion of tunnel measurement technique and development in unmanned automatic measuring system in the future finally.e finally.

  • PDF

Development of plane Motion Accuracy Measurement Unit of NC Lathe (NC 선반의 정면 운동정도 측정장치의 개발)

  • 김영석;한지희;정정표;윤원주;송인석
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제21권7호
    • /
    • pp.101-106
    • /
    • 2004
  • Measurements of linear motion accuracy for one axis of NC lathe have achieved with laser interferometer system, but measurement of plane motion accuracy for two axes on zx-plane of NC lathe have not achieved with the above system. Therefore in this study, measuring unit system is organized using two optical linear scales in order to acquire error. data during of plane motion of ATC(Automatic Tool Change.) of NC lathe by reading zx-plane coordinates. Two optical linear scales of measuring unit are fixed on zx-plane of NC lathe, and moving part of the scales are fixed to the ATC and then error motion data of z, x-coordinates of the ATC are received from the scales through the PC counter card inserted in computer at constant time intervals using tick pulses coming out from computer. And then, error motion data files acquired from measuring are saved in computer memory and the aspect of plane motion are modeled to plots, and range of the error data, means. average deviations, and standard deviations etc. are calculated by means of statistical treatments using computer programs.

Morphological Detection of Carotid Intima-Media Region for Fully Automated Thickness Measurement by Ultrasonogram

  • Park, Hyun Jun;Kim, Kwang Baek
    • Journal of information and communication convergence engineering
    • /
    • 제15권4호
    • /
    • pp.250-255
    • /
    • 2017
  • In this paper, we propose a method of detecting the region for measuring intima-media thickness (IMT). The existing methods for IMT measurement are automatic, but the region used for measuring IMT is not detected automatically but often set by the user. Therefore, research on detecting the intima-media region is needed for fully automated IMT measurement. The proposed method uses a morphological feature of the carotid artery visible as two long high-brightness horizontal lines at the upper and lower parts. It uses Gaussian blurring, ends-in search stretching, color quantization using a color-importance-based self-organizing map, and morphological operations to emphasize and to detect the morphological feature. The experimental results for evaluating the performance of the proposed method showed a 97.25% (106/109) success rate. Therefore, the proposed method can be used to develop a fully automated IMT measurement system.

A Study on Machining Method of Multi-Electrode (다수의 전극의 동시가공 방법에 관한 연구)

  • Jung T. S.;Yoo S. W.;Yang J. S.;Heo Y. M.;Kim K. S.
    • Transactions of Materials Processing
    • /
    • 제14권3호
    • /
    • pp.200-206
    • /
    • 2005
  • In general, a lot of small electrode is needed for making precision injection molds, such as cell phone mold and precision connector mold, because of the limitations of NC milling process. Those small electrodes usually have very simple shapes and the actual cutting time is so short, but many NC programs and set-up process, a very complicated and time consuming Job, are needed for each electrode. This paper deals the method for increasing the productivity of machining electrodes. In this work, the process standardization of machining electrode was done and special jig fer machining small electrodes was developed. Automatic tool path optimization software was also developed to minimize tool changing time. In addition, in-line cutting tool measuring system was adopted. The productivity of machining for small electrode has been increased up to $100\%$.

Implementation of Measuring System for the Auto Focusing (자동 초점 조절 검사 시스템 설계 및 구현)

  • Lee, Young Kyo;Kim, Young Po
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • 제8권4호
    • /
    • pp.159-165
    • /
    • 2012
  • The accurate focusing position should be determined for accurate measurements In VMS. Camera lens focusing is an important problem in computer vision and video measuring systems (VMS) that use CCD cameras and high precision XYZ stages. Camera focusing is a very important step in high precision measurement systems that use computer vision technique. The auto focusing process consists of two steps, the focus value measurement step and the exact focusing position determination step. It is suitable for eliminating high frequency noises with lower processing time and without blurring. An automatic focusing technique is applied to measure a crater with a one-dimensional search algorithm for finding the best focus. Throughout this paper, the suggested algorithm for the Auto focusing was combined with the learning. As a result, it is expected that such a combination would be expanded into the system of recognizing voices in a noisy environment.

A Study on the Development of on-machine Automatic Measuring System (On-machine 자동 측정 시스템 개발에 관한 연구)

  • 구본권;류제구;김종호;이우철
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 한국소성가공학회 1998년도 금형가공 심포지엄
    • /
    • pp.1-7
    • /
    • 1998
  • 본 연구에서는 3차원 솔리드 모델러로부터 Modeling한 후 제작된 model 에 사용자가 원하는 측정 위치를 지정함으로써 자동적으로 측정용 NC Data를 얻을 수 있는 알고리즘을 설계하고 이를 Program화하였다. 3-D Modeler로서 Unigraphics를 사용하였으며, 공작기계는 FANUC Controller를 장착한 Machining Center이다. 측정용 센서는 접촉식 Probe를 사용하였다. 본 연구를 통하여 CAD시스템에서 구축된 Geomaatric Model로부터 직접 측정을 위한 NC data를 얻고 이 data를 가공후의 측정 Data와 비교하여 봄으로써 제품의 가공정밀도를 확인해 볼 수 있으며, 가공시의 간섭 check, 잔삭가공여유, 과절삭등 다양한 정보를 얻을 수 있을 것이다. 향수 지속적인 연구개발을 통하여 data의 통계처리 및 공작기계의 오차 보정등을 고려하여 줌으로써 기계상에서의 측정 data에 대한 신뢰도를 구축할 수 있을 것으로 사료된다.

  • PDF

Automatic Measuring Apparatus for Salt and Dust Contamination (염진해 오손도 자동측정장치)

  • 최남호;구경완;이명섭;한상옥;정재기;조성배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.187-190
    • /
    • 1999
  • To reduce the maintenance expence, and the possibility of electric outage and accident, accurate measurement should be carried. But the classical method has some problems in the aspect of man power, reliability, and expence. In this paper, we propose a new type apparatus, which could detect the degree of contamination on insulators on outdoor insulation system, such as transmission and distribution line insulator and bushing. The new type apparatus consists of Pelltier module, electrode system, and measuring part. At first leakage current detecting method was considered, then with the fault(oxidation of electrode) of that method we should propose a another method. We carried various test to prove the possiblity and reliability of the propoused apparatus. And we get some useful result with laboratory test.

  • PDF