• Title/Summary/Keyword: Automatic flow control

Search Result 182, Processing Time 0.021 seconds

Spring Length Effect on the Flow Capacity of automatic Flow-Temperature Control Valve (자동 정유량 온도조절밸브의 스프링 길이가 밸브 용량에 미치는 영향)

  • Yoo, Seon-Hak;Kang, Seung-Duk;Park, Kyung-Am
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.174-177
    • /
    • 2003
  • The automatic temperature control valve is used to control the flow rate of heating water in the large apartment complex and buildings. It is important to have simillar heating flow rate in the apartments, even though the apartment is top or bottom floors. To achieve those purposes, the automatic flow-temperature control valve was developed. The perfromance of this control valve is effected by the catridge shape and spring length. The flow capacity of this control valve is obtained with the different shape of catridges and with change of spring length.

  • PDF

Internal Flow Analysis and Structural Design in Plastic Automatic Control Valve for the Semiconductor Chemical Liquid (반도체 약액용 자동제어 플라스틱 밸브의 내부 유동해석)

  • Lee, Gyu-Hoon;Lee, Eung-Suk;Lee, Min-Ki;Kim, Jin-Su;Bae, Il-Jin
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.2
    • /
    • pp.311-315
    • /
    • 2012
  • Diaphragm type noncontact automatic control valve is a valve for controling acidic PR(Photo Resist) liquid used in the semiconductor process. PR is photosensitive liquid that changes phases depending on light transmittance. PR is very toxic and expensive; the purpose of this paper is to address methods that prevent loss due to leaks. The design of noncontact precise automatic control valve is expected to play an important role in controlling fluid flow, therefore influencing energy conservation and environmental improvement. In this paper, diaphragm type automatic control valve's part design, assembly and simulation are introduced. Also, through the analysis of fluid flow the valve's internal velocity, pressure, and turbulent intensity are interpreted. This paper proposes to contribute to the improvement of the valve's performance.

Development of automatic flow control system for the practice of Ziegler-Nichols and Cohen-Coon control theory (Ziegler-Nichols와 Cohen-Coon 제어 이론의 실습을 위한 자동 유량제어 시스템의 구축)

  • Kang, Tae-Won;Lee, Ho-Gyun
    • Journal of Engineering Education Research
    • /
    • v.20 no.4
    • /
    • pp.61-66
    • /
    • 2017
  • Automatic flow control system composed by hardware and software was designed and fabricated to be used as teaching tool of feedback control theory in university experimental class. This system includes hardwares like data acquisition board, flow measuring device, transmitters, and the pneumatic valve, and software like LabView program for the monitoring and control of flow rates. The system was designed as the student can see the control effect of not only set point but also disturbance changes. Also the LabView program was composed for the calculation of controller parameters of both Ziegler-Nichols and Cohen-Coon tuning. The students can apply both tuning constants and compare the control performances. This system will provide the easy way for the students to understand the function and specification of control hardwares, and to raise the programing ability of control software.

Automatic Flow Control and Network Monitoring of IV Injection (자동 IV 주사 유량 자동 제어 및 네트워크 모니터링)

  • Kim, Jin-Nam;Kwon, Won-Tae;Lee, Kang-Hee
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.1
    • /
    • pp.161-166
    • /
    • 2012
  • Intravenous (IV) injection is widely used to supply Ringer solution directly into a vein in hospital. Generally, a passive injection method has been used, which causes the inconsistent flow rate of fluid and inappropriate control of injection time by a patient. It leads to an unnecessary nurse's overwork and decrement of IV injection's effect. To solve these problems, flow control infusion pumps have been developed. But because of relatively heavy weight and high price, its usage has been limited. In the present study, a new automatic IV injection system is developed. It is installed with a small pressing mechanism driven by a small electric motor to regulate the flow rate by pressing tube. Proportional integral derivative (PID) feedback control algorithm is applied to control the electric motor. The system is smaller in size and uses lower power than the existing commercial product. The newly developed system is also installed with networking capability, which enables monitoring the status of several automatic IV injection system at the same time.

A Study on the Hydraulic Automatic Gauge Control System of Adaptive Mass Flow Method (Adaptive mass flow method 유압압하식 자동 두께제어 장치에 관한 연구)

  • 윤순현;김문경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.101-107
    • /
    • 1996
  • This test was performed on the hydraulic automatic gauge control(AGC) system of adaptive mass flow method. Fundamental purpose of this study are performance evaluation of this AGC system under the actual rolling condition. It was concluded that the response of AGC system depends on the dynamic characteristics of a reel motor or roll position. The test results are as follows : 1) The control method of reel motor current is better than than of the roll position as AGC system. 2) The more steel strip thickness of delivery side is thick, the larger the gauge deviation is large, and the more it is thin, the larger the gauge deviation rate is large. 3) Because the gauge deviation is large at acceleration and deceleration speed than steady speed, so AGC system is better to adopt over 50m/min. By applying this AGC system, not only the accurary in strip thickness were improved but also productivity was improved dramatically.

  • PDF

Study of data flow control algorithm for automatic fault estimation in SCADA (SCADA 자동고장판단을 위한 데이터 흐름제어 알고리즘 연구)

  • Park, Jeong-Jin;Kim, Kern-Joong;Hwang, In-Jun;Yang, Min-Uk;Lee, Jae-Won;Cho, Hui-Chang;Kim, Tae-Won
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.296-298
    • /
    • 2008
  • Currently SCADA System faces various fault situation. Operator must recognize all fault state and management plans. But it is not easy to recognize all category and acquired error data. So it is needed that automatic fault estimation. Automatic fault estimation is possible to data flow control. Data flow control method is two type. One is alarm processing and the other one is topology processing. This paper provide two type processing method in SCADA data flow control.

  • PDF

Application of UNIX System to Automatic Control (UNIX SYSTEM을 이용한 종합제어 장치)

  • Park, Sung-Sik;Shin, Young-Kil;Rho, Tae-Suk;Cho, Kyu-Bok
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.874-876
    • /
    • 1991
  • This paper deals with the topics when Unix based computer is applied to automatic manufacturing system. The total control of material flow in the automatic storage and retrieval system is taken as an example. And some technical issues are proposed for the wider application of UNIX to automatic control.

  • PDF

Implementation of Wind Power System and Development of a Automatic Tail Safety Controller (풍력발전시스템의 강풍제어기 개발 및 시스템 구성)

  • Choi, Jung-Hoon;Moon, Chae-Joo;Jang, Yung-Hak;Lee, Hyun-Ju
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.424-428
    • /
    • 2004
  • A wind turbine system converts wind energy into electric energy, the system operated under normal environmental conditions. In case of particular turbulent wind flow such as typhoon, hurricane etc, the control of a blade used to a yaw control and a pitch control method. A small wind turbine has not a speed control system to only a manual tail safety brake. This paper shows a automatic tail safety brake controller based on feedback control using wind velocity. The controller composed of wired motor, relay system, steel wired motor him down a perpendicular to wind flow and then the blade speed reduced high to zero. The operation of automatic tail safety controller verified by manual test.

  • PDF

Automatic Optimum Control of the Traffic Signal Lights (교통신호의 자동최적제어에 관한 연구)

  • 양흥석;김호윤
    • 전기의세계
    • /
    • v.20 no.4
    • /
    • pp.12-16
    • /
    • 1971
  • The electrical detector and computer systems for traffic flow and speed measurement are demonstrated in this paper. For the best traffic control optimization, linear and non-linear equations in the transition state are dealing with the perturbation of the linear car-following. In the conclusions, we construct a realizable system for the central automatic traffic control with a computer. Furthermore, fixed periodic switching system by manual with the automatic traffic control system is recommended for emergency perturbation.

  • PDF

Fuzzy-PI Cascade Control of Drum Level of Boiler in Thermal Power Plan (화력 발전소 드럼수위의 퍼지-PI 캐스케이드 제어)

  • Byun, S.H.;Cho, J.Y.;Kim, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.458-460
    • /
    • 1998
  • The drum level control is initiated by 1-element manual control, and then the control mode is changed to 1-element automatic control mode. Finally, the drum level control is changed to 3-element automatic control mode by the logic based on pre-defined threshold of main steam flow. In terms of plant automation, the automatic 1-element control mode is required from the start-up of boiler. In this paper, the fuzzy controller is adopted for automatic 1-element control of drum level from start-up. It is suggested that the fuzzy controller is used in 1-element control, and the fuzzy-PI cascade controller is used in 3-element control. Finally, the validity of suggested control scheme is shown via simulation.