• 제목/요약/키워드: Automatic check

검색결과 300건 처리시간 0.025초

슬라브 내부 크랙 및 중심편석 자동 판정 시스템 개발 (Automatic Measuring System Developement of Slab Inner Crack and Center Segregation)

  • 김성용;이수현;안인석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2009년도 정보 및 제어 심포지움 논문집
    • /
    • pp.332-334
    • /
    • 2009
  • This thesis puts forward a suggestion of measuring inner crack and center segregation in steel processing by using scanner and image processing with sulfur printer. This is a system to scan according to the program, to choose the size of the specimen and to press the 'Measurement' button, come to a check result, to send the result to the server, and to save the data and check the measurement result in web. To sum up, there are three points in this system.

  • PDF

A study about Embodying an AMR Based on Power Line Communication.

  • Yoon, Gun;Park, Hong-Seong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.119.2-119
    • /
    • 2001
  • The inspection of a meter is an action that measures the amount of electricity, water and gas used to impose user on a charge. In past days, a meter who visit consumer to look over meter and write data to the ledger and then go back his office to calculates the inspection of a meter. On the other hand, the AMR(Automatic Meter Reading) is remote control system to measure the amount of utility used and monitor a condition of the meter. A study about AMRS is started at 1960 all over the world and a successful application example is presented continuously in American, Europe and Japan etc. In this paper we use a check meter that is used in past days and we add an AMR to it. AMR receives data that is the amounts of electricity from the check meter and stores those ...

  • PDF

CAD 시스템에 의하여 작성된 기계도면의 자동검증시스템에 관한 연구 (A Computer Aided Automatic Verification System for Mechanical Drawings Drawn with CAD System)

  • Lee, S.S.
    • 한국정밀공학회지
    • /
    • 제13권8호
    • /
    • pp.60-71
    • /
    • 1996
  • Mostof existing CAD systems do not provide the advanced function for systematic checking of design and drafting errors in mechanical drawings. We have reported a computer aided drawing check system to single plane projection drawings made by a CAD system. This paper describes a checking method of dimensioning errors in mechanical drawings. The checking items are deficiency and redundancy of dimensions, input-errors in dimension figures and symbols, etc. Checking for deficiency and redundancy of global dimensions has been performed applying Graph Theory. This system has been applied to several examples and we have confirmed the feasibility of this checking method.

  • PDF

통신위성 중계기 시험을 위한 EGSE 설계 및 구현 (Design and Implementation of EGSE for the CBS Transponder Testing)

  • 조진호;정용길;최완식;박종홍;이성팔
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(1)
    • /
    • pp.235-238
    • /
    • 2002
  • In this paper we describe the design and implementation of Electrical Ground Support Equipment(EGSE) for the CBS transponder testing. The main task of EGSE is to check out satellite systems, at system or subsystem level, during integration and validation phases of their life-cycle. Through a combination of hardware and software elements, EGSE supports manual, semi-automatic and fully automated testing. Automation is achieved by offering users simple, yet powerful means to write their own test application programs (test sequences) in high-level, test-oriented language and to run them in a strict real-time environment. The core of this environment is a user-configurable real-time database, containing all the information needed to calibrate acquired data, check them against predefined thresholds, automatically react to out-of-range conditions, display data using animated graphics or synoptic windows, and so on.

  • PDF

Quantitative Accuracy Assessment of a SPOT DEM along the Coast-Donghae City Area

  • Kim, Seung-Bum;Lee, Hae-Yeoun
    • 대한원격탐사학회지
    • /
    • 제16권2호
    • /
    • pp.177-188
    • /
    • 2000
  • Quantitative accuracy assessment of a SPOT DEM (Digital Elevation Model) generated by a fully automatic software is performed along the 90km long coast around Donghae city. The theoretical requirement on the layout of the CPS (Global Positioning System) check points is derived: the Nyquist sampling. Since in practice the Nyquist frequency of a terrain is difficult to determine, the relaxed requirements are introduced and 31 check points are collected accordingly. Accuracy of the SPOT DEM is calculated to be 8.9, 11.5 and 12.0m r.m.s. in latitudinal, longitudinal and elevation directions. The bias is distinguishable from zero only for elevation and is 2.2m. The simple comparison with the world's leading commercial softwares reveals the similar accuracy level.

A One-Size-Fits-All Indexing Method Does Not Exist: Automatic Selection Based on Meta-Learning

  • Jimeno-Yepes, Antonio;Mork, James G.;Demner-Fushman, Dina;Aronson, Alan R.
    • Journal of Computing Science and Engineering
    • /
    • 제6권2호
    • /
    • pp.151-160
    • /
    • 2012
  • We present a methodology that automatically selects indexing algorithms for each heading in Medical Subject Headings (MeSH), National Library of Medicine's vocabulary for indexing MEDLINE. While manually comparing indexing methods is manageable with a limited number of MeSH headings, a large number of them make automation of this selection desirable. Results show that this process can be automated, based on previously indexed MEDLINE citations. We find that AdaBoostM1 is better suited to index a group of MeSH hedings named Check Tags, and helps improve the micro F-measure from 0.5385 to 0.7157, and the macro F-measure from 0.4123 to 0.5387 (both p < 0.01).

자동 캡 세척장치 개발에 관한 연구 (A Study on the Development of Automatic Cap-Washing M/C)

  • 신성우;김대성;이춘만
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1849-1852
    • /
    • 2005
  • An automatic cap-washing machine is developed for rinse and dry of synthetic resin cap which is used in spring water bottle. This machine should be achieved all processes washing and drying, array, transfer automatically. A cap is washed by an ozonized water and pure water first. Next, a cap is dried by a hot wind drying equipment. In this paper, structural and modal analysis for the cap-washing machine is carried out to check the design criterion of the machine. The analysis is carried out by FEM simulation using the commercial software, CATIA V5. And a fictitious mass properties was used for the analysis of the machine. Finally, the machine performance is shown to be satisfactory.

  • PDF

유무선 통신을 이용한 DCS 터미널 원격 감시 보드 설계 및 구현 (Design and Implementation of DCS Terminal Remote Monitoring Board using Wire and Wireless Communication)

  • 박해동;강전욱;김재환;이세훈
    • 한국컴퓨터정보학회지
    • /
    • 제14권2호
    • /
    • pp.117-122
    • /
    • 2006
  • 이 논문에서는 기존 개발된 일체형의 통합 터미널 보드의 유선방식을 배제하고 무선방식으로 자동제어시스템에서의 중요 신호에 대한 전체적 통합관리시스템 구축을 위한 DCS 터미널 원격 감시 보드를 설계 제작하고 제작된 보드의 동작을 테스트하기 위해 원격감시 프로그램을 구현하여 기능을 평가한다. 구현된 원격감시보드는 전원관리실의 각 릴레이들의 동작상태 및 릴레이와 퓨즈의 이상 유무를 실시간으로 확인이 가능하며 릴레이의 수명을 고려하여 릴레이의 고장을 사전에 예방함으로써 산업분야의 경제적인 효과가 기대된다.

  • PDF

식물을 이용한 실내공기조절시 이산화탄소의 영향에 관한 연구 (A Study on the Effect of CO2 in Condition of Indoor Air Quality Control Using Plants)

  • 이규인;권민재
    • KIEAE Journal
    • /
    • 제7권4호
    • /
    • pp.39-44
    • /
    • 2007
  • The purpose of this research is to study security of $CO_2$ exhaust at night in indoor air quality purifying system using plants. For this purpose, two same units for experiment were built, and difference of $CO_2$ exhaust by existence and nonexistence of plantation were measured. To reduce error by entrance of people, automatic measurement system were developed and used. At first, baseline were measured to check standard value, and next, $CO_2$ exhaust by plantation were measured. As a result, in baseline experiment, values of all spaces were steady as 400~500 ppm. When plantation was set-up, value of $CO_2$ at night was measured high as 150 ppm, and maximum value was around 600 ppm. This result is a lot lower than maximum standard of $CO_2$, 1000 ppm.

일본의 자동화 터미널 시설계 소개 (Instroduction of Automatic Container Terminal designed by Japan)

  • 정영석;진규호
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 1998년도 추계학술대회논문집:21세기에 대비한 지능형 통합항만관리
    • /
    • pp.19-49
    • /
    • 1998
  • I try to introduce three types of designs for automatic container operating system which are designed by Institute of Japan Port Research in 1996. Each types are designedto fit with the situations of Japan Port. 'A'type of these designs adapts Dual Container Crane, AGV, RMG, etc. 'B'type of these designs adapts Dual Container Crane, AGV, OHBC, RTG. And 'C'type of these designs adapts Single Container Crane, AGV, OHBC, etc. Even if three designs are introduced, they have some problems to solve for the future. They are Lashing work, Refeer container problem, check for container and seal in main gate, Establishing EDI NETWORK, etc. I expect that this paper will be a helps to development of our port industry.

  • PDF