• Title/Summary/Keyword: Automatic Measuring System

Search Result 356, Processing Time 0.029 seconds

Conceptual Design for a Diagnosis System of Vehicle Performance using the Satellite Telemetry Technology (위성 원격측정기술을 이용한 차량 성능진단시스템 개념 설계)

  • Eun, Jong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4576-4582
    • /
    • 2010
  • Because most of vehicle provide users with the very limited information regarding the performance of vehicle, it is quite difficult for users to drive vehicles safe, and to maintain and repair vehicles properly. In order to solve the above-mentioned problems, several ways of research and development for the vehicle control and diagnosis system have been recently carried out. However, a lot of complicated problems and difficulties were arising due to the complexity of the developed system, degradation of the reliability for the vehicle performance control system, operational malfunction and so on. In this paper, for the purpose of solving the difficult problems and technical limitations, a system for vehicle performance which might be able to diagnose the reliability of vehicle performance by measuring and analyzing the real time performance of vehicle using the satellite telemetry technology was conmance oly defined and deehiced.hihe results derived from the cormance ofdvehiclactivities in this study shall be used as not only fundamental data but also materials for the detailed design for the implementation of vehicle performance diagnosis system in the near future.

Exophthalmometric values using White-light Scanning Interferometer (백색광 간섭계를 이용한 안구 돌출 값 측정)

  • Chang, Jung-soo;Kim, Young-kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.12
    • /
    • pp.2341-2346
    • /
    • 2017
  • The relative position of the eyeballs in the orbit can be a criterion for estimating multiple pathological conditions. Especially, it is useful to diagnose orbital fracture, thyroid eye disease, orbital tumor, and to evaluate the result of drug and surgical treatment. The Hertel and Naugle exophthalmometer, which are the most commonly used measuring instruments for measuring the prominence of the eye, are different from each other. Even if the same examiner repeatedly measures, it is inevitable. Also, even if the same exophthalmometer is different from the manufacturing company, the design of the fixed part of the orbit is different, and a measurement error is caused by the inspectors. In this paper, we propose a method of automatic measurement that can increase the accuracy and repeatability of measurement of exophthalmos using white light scanning interferometer, which is a 3D image measurement technique.

Comparison of Magnetocardiogram Parameters Between a Ischemic Heart Disease Group and Control Group (정상군 및 허혈성 심질환 환자군에서의 심자도 파라미터 비교)

  • Park, Jong-Duk;Huh, Young;Jin, Seung-oh;Jeon, Sung-chae
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.11
    • /
    • pp.680-688
    • /
    • 2005
  • The electrical current generated by heart creates not only electric potential but also a magnetic field. We have observed electrophysiological phenomena of the heart by measuring components of magnetocardiogram(MCG) using 61 channel superconducting quantum interference device(SQUD) system. We have analyzed the possibility and characteristics of MCG parameters for diagnosis of ischemic heart disease. A technique for automatic analysis of MCG signals in time domain was developed. The methods for detecting the position, the interval, the amplitude ratio, and the direction of single current dipole were examined in the MCG wave. The position and interval parameters were obtained by calculating the gradients of a envelope curve which could be formed by the difference between the maximum and minimum envelope of multi-channel MCG signals. We show some differences of the frequency contour map between the normal MCG and the abnormal (ischemic heart disease) MCG. The direction of single current dipole can be defined by rotating the magnetic field according to Biot-Savart's law at each point of MCG signals. In this study, we have examined the direction of single current dipole from searching for the centroids of positive and negative magnetic fields. The amplitude ratio parameters for measuring 57 deviation consisted of A$_{T}$/A$_{R}$ and other ratios. and We developed a new analysis method, which is based on the frequency contour map of electromagnetic field. Using theses parameters, we founded significant differences between normal subjects and ischemic patients in some parameters.

Performance Evaluation of Automatic Exercise Weight and Repetition Measuring Device Add-on for Existing Fitness Machines (기존 운동기기 부착용 운동중량/횟수 자동측정기기의 성능평가)

  • Kim, Jung Gi;Lee, Yongkoo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.4
    • /
    • pp.329-332
    • /
    • 2017
  • In this study, a performance evaluation was carried out to develop a new add-on device with an algorithm for automatically measuring the exercise weight and repetitions when using an existing fitness machine. The developed device was designed to be simply attached to an exercise machine to measure the exercise weight and repetitions. The measured data are transferred to a smartphone using Bluetooth. As result, it is possible to detect the weights and repetitions from three users with different exercise habits with little error. The system can measure the user's motion and transfer the data to various devices capable of utilizing the workout data, giving it the advantage of being applicable to personalized health care and rehabilitation therapy.

Displacement Measurement of Structure using Multi-View Camera & Photogrammetry (사진측량법과 다시점 카메라를 이용한 구조물의 변위계측)

  • Yeo, Jeong-Hyeon;Yoon, In-Mo;Jeong, Young-Kee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.1141-1144
    • /
    • 2005
  • In this paper, we propose an automatic displacement system for testing stability of structure. Photogrammetry is a method which can measure accurate 3D data from 2D images taken from different locations and which is suitable for analyzing and measuring the displacement of structure. This paper consists of camera calibration, feature extraction using coded target & retro-reflective circle, 3D reconstruction and analyzing accuracy. Multi-view camera which is used for measuring displacement of structure is placed with different location respectively. Camera calibration calculates trifocal tensor from corresponding points in images, from which Euclidean camera is calculated. Especially, in a step of feature extraction, we utilize sub-pixel method and pattern recognition in order to measure the accurate 3D locations. Scale bar is used as reference to measure. the accurate value of world coordinate..

  • PDF

Automatic Quality Evaluation with Completeness and Succinctness for Text Summarization (완전성과 간결성을 고려한 텍스트 요약 품질의 자동 평가 기법)

  • Ko, Eunjung;Kim, Namgyu
    • Journal of Intelligence and Information Systems
    • /
    • v.24 no.2
    • /
    • pp.125-148
    • /
    • 2018
  • Recently, as the demand for big data analysis increases, cases of analyzing unstructured data and using the results are also increasing. Among the various types of unstructured data, text is used as a means of communicating information in almost all fields. In addition, many analysts are interested in the amount of data is very large and relatively easy to collect compared to other unstructured and structured data. Among the various text analysis applications, document classification which classifies documents into predetermined categories, topic modeling which extracts major topics from a large number of documents, sentimental analysis or opinion mining that identifies emotions or opinions contained in texts, and Text Summarization which summarize the main contents from one document or several documents have been actively studied. Especially, the text summarization technique is actively applied in the business through the news summary service, the privacy policy summary service, ect. In addition, much research has been done in academia in accordance with the extraction approach which provides the main elements of the document selectively and the abstraction approach which extracts the elements of the document and composes new sentences by combining them. However, the technique of evaluating the quality of automatically summarized documents has not made much progress compared to the technique of automatic text summarization. Most of existing studies dealing with the quality evaluation of summarization were carried out manual summarization of document, using them as reference documents, and measuring the similarity between the automatic summary and reference document. Specifically, automatic summarization is performed through various techniques from full text, and comparison with reference document, which is an ideal summary document, is performed for measuring the quality of automatic summarization. Reference documents are provided in two major ways, the most common way is manual summarization, in which a person creates an ideal summary by hand. Since this method requires human intervention in the process of preparing the summary, it takes a lot of time and cost to write the summary, and there is a limitation that the evaluation result may be different depending on the subject of the summarizer. Therefore, in order to overcome these limitations, attempts have been made to measure the quality of summary documents without human intervention. On the other hand, as a representative attempt to overcome these limitations, a method has been recently devised to reduce the size of the full text and to measure the similarity of the reduced full text and the automatic summary. In this method, the more frequent term in the full text appears in the summary, the better the quality of the summary. However, since summarization essentially means minimizing a lot of content while minimizing content omissions, it is unreasonable to say that a "good summary" based on only frequency always means a "good summary" in its essential meaning. In order to overcome the limitations of this previous study of summarization evaluation, this study proposes an automatic quality evaluation for text summarization method based on the essential meaning of summarization. Specifically, the concept of succinctness is defined as an element indicating how few duplicated contents among the sentences of the summary, and completeness is defined as an element that indicating how few of the contents are not included in the summary. In this paper, we propose a method for automatic quality evaluation of text summarization based on the concepts of succinctness and completeness. In order to evaluate the practical applicability of the proposed methodology, 29,671 sentences were extracted from TripAdvisor 's hotel reviews, summarized the reviews by each hotel and presented the results of the experiments conducted on evaluation of the quality of summaries in accordance to the proposed methodology. It also provides a way to integrate the completeness and succinctness in the trade-off relationship into the F-Score, and propose a method to perform the optimal summarization by changing the threshold of the sentence similarity.

Development of An Automatic Classification System for Game Reviews Based on Word Embedding and Vector Similarity (단어 임베딩 및 벡터 유사도 기반 게임 리뷰 자동 분류 시스템 개발)

  • Yang, Yu-Jeong;Lee, Bo-Hyun;Kim, Jin-Sil;Lee, Ki Yong
    • The Journal of Society for e-Business Studies
    • /
    • v.24 no.2
    • /
    • pp.1-14
    • /
    • 2019
  • Because of the characteristics of game software, it is important to quickly identify and reflect users' needs into game software after its launch. However, most sites such as the Google Play Store, where users can download games and post reviews, provide only very limited and ambiguous classification categories for game reviews. Therefore, in this paper, we develop an automatic classification system for game reviews that categorizes reviews into categories that are clearer and more useful for game providers. The developed system converts words in reviews into vectors using word2vec, which is a representative word embedding model, and classifies reviews into the most relevant categories by measuring the similarity between those vectors and each category. Especially, in order to choose the best similarity measure that directly affects the classification performance of the system, we have compared the performance of three representative similarity measures, the Euclidean similarity, cosine similarity, and the extended Jaccard similarity, in a real environment. Furthermore, to allow a review to be classified into multiple categories, we use a threshold-based multi-category classification method. Through experiments on real reviews collected from Google Play Store, we have confirmed that the system achieved up to 95% accuracy.

Three-dimensional shape measurement using grating patterns form an optical spatial modulator

  • Tsujioka, Katsumi;Ito, Hiroshi;Furuhashi, Hideo;Higa, Shuntaro;Hayashi, Niichi;Yamada, Jun;Hatano, Kazuo;Uchida, Yoshiyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.561-565
    • /
    • 1994
  • An automatic measuring system of three dimensional shape by a projection method with grating pattern from in optical spatial modulator has been developed. The characteristics of the system were studied. This system is composed of a projector, an optical spatial modulator, a CCD camera, and computer. A liquid crystal is used as the optical spatial modulator. The grating patterns that ire projected on the surface of the object are controlled by the computer connected with the optical spatial modulator. The projector patterns are measured by the CCD camera. The data are transferred to the computer. After a transformation into line data, the data are analyzed to obtain the coordinate of the surface of the object. This system has advantages as follows. (1) It is possible to capture the surface topography without any contact. (2) The time required for the measurements is shorter than the light-section method. (3) An optical spatial modulator using a liquid crystal is possible to control the grating patterns accurately by a computer. Surfaces of a plate and a cylinder were measured. The threshold level had an influence on the measurement. It was shown that this system has adequae accuracy in the measurements.

  • PDF

The Study for the CMP Automation with Nova Measurement System (NOVA System을 이용한 CMP Automation에 관한 연구)

  • Kim, Sang-Yong;Chung, Hun-Sang;Park, Min-Woo;Kim, Chang-Il;Chang, Eui-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.176-180
    • /
    • 2001
  • There are several factors causing re-work in CMP process such as improper polish time calculation by operator. removal rate decline of the polisher, unstable in-suit pad conditioning, slurry supply module problem and wafer carrier rotation inconsistancy. And conclusively those fundimental reason for the re-work rate increasement is mainly from the cycle time delay between wafer polish and post measurement. Therefore, Wafer thickness measurement in wet condition could be able to remove those improper process conditions which may happen during the process in comparison with the conventional dried wafer measurement system and it can be able to reduce the CMP process cycle time. CMP scrap reduction by overpolish, re-work rate reduction, thickness control efficiency also can be easily achieved. CMP Equipment manufacturer also trying to develop integrated system which has multi-head & platen, cleaner, pre & post thickness measure and even control the polish time from the calculated removal rate of each polishing head by software. CMP re-work problem such as over & under polish by target thickness may result in the cycle time delay. By reducing those inefficient factors during the process and establish of the automatic process control, CLC system need to be adopted to maximize the process performance. Wafer to Wafer Polish Time Feed Back Control by measuring the wafer right after the polish shorten the polish time calculation for the next wafer and it lead to the perfact Post CMP target thickness control capability. By Monitoring all of the processed the wafer, CMP process will also be stabilize itself.

  • PDF

The Study for the CMP Automation wish Nova Measurement system (NOVA System을 이용한 CMP Automation에 관한 연구)

  • 김상용;정헌상;박민우;김창일;장의구
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.176-180
    • /
    • 2001
  • There are several factors causing re-work in CMP process such as improper polish time calculation by operator, removal rate decline of the polisher, unstable in-suit pad conditioning, slurry supply module problem and wafer carrier rotation inconsistency. And conclusively those fundimental reason for the re-work rate increasement is mainly from the cycle time delay between wafer polish and post measurement. Therefore, Wafer thickness measurement in wet condition could be able to remove those improper process conditions which may happen during the process in comparison with the conventional dried wafer measurement system and it can be able to reduce the CMP process cycle time. CMP scrap reduction by overpolish, re-work rate reduction, thickness control efficiency also can be easily achieved. CMP Equipment manufacturer also trying to develop integrated system which has multi-head & platen, cleaner, pre & post thickness measure and even control the polish time from the calculated removal rate of each polishing head by software. CMP re-work problem such as over & under polish by target thickness may result in the cycle time delay. By reducing those inefficient factors during the process and establish of the automatic process control, CLC system need to be adopted to maximize the process performance. Wafer to Wafer Polish Time Feed Back Control by measuring the wafer right after the polish shorten the polish time calculation for the next wafer and it lead to the perfect Post CMP target thickness control capability. By Monitoring all of the processed the wafer, CMP process will also be stabilize itself.

  • PDF