• Title/Summary/Keyword: Automatic Measuring System

Search Result 356, Processing Time 0.024 seconds

A Study on the Automatic Fuel-Filling-Recognition system for a city bus (자동인식 주유량 처리 시스템에 관한 연구)

  • 김현수;안병원;박중순;박영산;배철오;김철홍
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.414-417
    • /
    • 2001
  • In this paper the fuel filling system for a city bus was investigated in order to improve the system. The suggested fuel filling system was designed to have functions of identifying a bus arrival tine, and measuring volume of fuel filled. The system consisted of four parts of bus identification, IBM PC, interface card, fuel filling control system and program for integrating all parts. It is believed that the information obtained by this system can be used for analysing driver's driving habits and performance of engine of a bus, and accordingly the prime cost can be reduced.

  • PDF

A Study on Automatic Inspection Technology of Machinery Parts Based on Pattern Recognition (패턴인식에 의한 기계부품 자동검사기술에 관한 연구)

  • Cha, Bo-Nam;Roh, Chun-Su;Kang, Sung-Ki;Kim, Won-il
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.17 no.2
    • /
    • pp.77-83
    • /
    • 2014
  • This paper describes a new technology to develop the character recognition technology based on pattern recognition for non-contacting inspection optical lens slant or precision parts, and including external form state of lens or electronic parts for the performance verification, this development can achieve badness finding. And, establish to existing reflex data because inputting surface badness degree of scratch's standard specification condition directly, and error designed to distinguish from product more than schedule error to badness product by normalcy product within schedule extent after calculate the error comparing actuality measurement reflex data and standard reflex data mutually. Developed system to smallest 1 pixel unit though measuring is possible 1 pixel as $37{\mu}m{\times}37{\mu}m$ ($0.1369{\times}10-4mm^2$) the accuracy to $1.5{\times}10-4mm$ minutely measuring is possible performance verification and trust ability through an experiment prove.

On Automatic Apparatus for Cryoscopy and Improvement in Experimental Method (Cryoscopy 裝置와 方法의 改良에 關한 硏究)

  • Shin, Yun-Kyong;Lee, Joon
    • Journal of the Korean Chemical Society
    • /
    • v.18 no.2
    • /
    • pp.143-149
    • /
    • 1974
  • The traditional cryoscopic measurement had performed by inconvenient manual operation which accompanies various unavoidable errors. For example, the irregularity of hand stirring, difference of visual angle in reading Beckmann thermometer and furthermore, its large heat capacity acts as the decreasing effect of the sensitivity. In these studies, the author devised new automatically measuring cryoscopic apparatus with temperature recording system in which temperature variation is changed to electric current. The light beam from the galvanometer is absorbed by the photographic paper on the rotating cylinder. On the other hand, the use of sodium sulfate decahydrate in cryoscopy causes considerable error, because small crystal particles adhere on the upper wall of the measuring tube. As an improvement, anhydrous sodium sulfate is used and then the desired amount of water is added.

  • PDF

A Study on the Control System of Myoelectric Hand Prosthesis (근전의수의 제어시스템에 관한 연구)

  • Choi, Gi-Won;Chu, Jun-Uk;Choe, Gyu-Ha
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.214-221
    • /
    • 2007
  • This paper presents a myoelectric hand prosthesis(MHP) with two degree of freedom(2-DOF), which consists of a mechanical hand, a surface myoelectric sensor(SMES) for measuring myoelectric signal, a control system and a charging battery. The actuation for the 2-DOF hand functions such as grasping and wrist rotation was performed by two DC-motors, and controlled by myoelectric signal measured from the residual forearm muscle. The grip force of the MHP was automatically changed by a mechanical automatic speed reducer mounted on the hand. The skin interface of SMES was composed of the electrodes using the SUS440 metal in order to endure a wet condition due to the sweat. The sensor was embedded with a amplifier and a filter circuit for rejecting the offset voltage caused by power line noises. The control system was composed of the grip force sensor, the slip sensor, and the two controllers. The two controllers were made of a RISC-type microprocessor, and its software was executed on a real-time kernel. The control system used Force Sensing Resistors, FSR, as slip pick-ups at the fingertip of a thumb and the grip force information was obtained from a strain-gauge on the lever of the MHP. The experimental results were showed that the proposed control system is feasible for the MHP.

A Study on the Tool Fracture Detection Algorithm Using System Identification (시스템인식을 이용한 공구파손검출 알고리듬에 관한 연구)

  • Sa, Seung-Yun;Yu, Eun-Lee;Ryu, Bong-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.6
    • /
    • pp.988-994
    • /
    • 1997
  • The demands for robotic and automatic system are continually increasing in manufacturing fields. There have been many studies to monitor and predict the system, but they have mainly focused upon measuring cutting force, and current of motor spindle, and upon using acoustic sensor, etc. In this study, digital image of time series sequence was acquired by taking advantage of optical technique. Mean square error was obtained from it and was available for useful observation data. The parameter was estimated using PAA(parameter adaptation algorithm) from observation data. AR(auto regressive) model was selected for system model and fifth order was decided according to parameter estimation. Uncorrelation test was also carried out to verify convergence of parameter. Through the proceedings, it was found that there was a system stability.

Study on Analytical and Empirical Methods for Assessing Geo-Heat Transfer Characteristics (지중열전달특성 평가에 관한 해석 및 실험적 방법에 관한 연구 - 지중 열물성치 및 보어 홀 열 저항 평가 -)

  • Park Jun-n;Baek Nam-Choon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.427-432
    • /
    • 2005
  • This study treats the advantage of in situ line source method measuring the heat transfer capacity of a borehole, using mobile equipment, to determine the thermal properties of the entire borehole system such as thermal conductivity, diffusiveity. volumetric heat capacity, and borehole thermal resistance. The results from the response test include not only the thermal properties of the ground and the borehole, but also conditions that are difficult to estimate, e,g. natural convection in the boreholes, asymmetry in the construction, etc. In this study, 1) theoretical in situ methods for assessing working fluid temperature variation in V-type PE tube have been introduced, and 2) TRTE(Thermal Response Test Equipment) has been built based on these kinds of theoretical in situ methods. Basically TRTE consists of a pump, a heater and temperature sensors for measuring the inlet and outlet temperatures of the borehole. In order to make equipment easily transportable it is set up on a small trailer. Since the response test takes above two days to execute, the test was fully automatic in recording measured data using Labview DAS(Data acquisition system) program. The test was demonstrated in the course of intensive research in this field through the one site at Ulsan city in Korea. From this kind of thermal properties test of borehole systems in situ, the design of the borehole system can be optimized regarding the total geological, hydro-geological and technical conditions at the location.

  • PDF

Slope Behavior Analysis Using the Measurement of Underground Displacement and Volumetric Water Content (지중 변위와 체적 함수비 계측을 통한 사면 거동 분석)

  • Kim, Yongseong;Kim, Manil;Bibek, Tamang;Jin, Jihuan
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.9
    • /
    • pp.29-36
    • /
    • 2018
  • Several studies have been conducted on monitoring system and automatic measuring instruments to prevent slope failure in advance in Korea and overseas. However, these studies have quite complex structure. Since most of the measurement systems are installed on the slope surface, the researches are carried on the measurement system that detects sign of slope collapse in advance and alerts are still unsatisfactory. In this study, slope collapse experiments were carried out to understand the slope failure mechanism according to rainfall conditions. The water content and displacement behavior at the early stage of the slope failure were analyzed through the measurement of the ground displacement and water content. The results of this study can be used by local government as a basic data for the design of slope failure alarm system to evacuate residents in case of slope failure or landslide due to heavy rainfall.

Study on precision improvement in weight measurement of an egg for the automatic egg sorting system (계란(鷄卵) 자동(自動) 선별기(選別機)의 난중측정(卵重測定) 정밀도(精密度) 향상(向上)에 관(關)한 기초연구(基礎硏究))

  • Kim, K.D.;Bok, J.S.
    • Korean Journal of Agricultural Science
    • /
    • v.27 no.1
    • /
    • pp.48-53
    • /
    • 2000
  • The various errors existing in a weight measurement system in most automatic egg sorting system available in Korean poultry farms have caused a large amount of economic losses to the egg producers. The object of this study was an importance of egg measurement system by changing both the number and the arrangements of load cells to reduce measuring errors. The results obtained were summarized as follow : 1. Four arrangements of load cells were selected as follows : layout I : Conventional one load cell method layout II : One load cell located as egg moving direction layout III : Two load cells located facing each other layout IV : Two load cells located as parallel with egg moving direction 2. The results of egg weight measurement according to four arrangements (Layout I, II, III, IV) showed that the average errors were 1.1218g, 0.5953g, 0.7786g, 0.2793g respectively. This indicated that the Layout IV (measuring by 2 load cells located parallel with the egg moving direction) caused the lowest average error and the best in precision. 3. The average vibration of axis X, y, Z were resulted as $5.1937{\times}10^{-3}G$, $9.3604{\times}10^{-3}G$, and $16.8657{\times}10^{-3}G$ respectively when sorting large sized egg. This indicated that the vibration of axis-Z was relatively higher than those of axis-X, and axis-Y.

  • PDF

A Study on the Application of the Apparel CAD System(II) (어패럴 CAD System의 활용화 방안 연구(II) - 테일러드 쟈켓 설계 과정을 중심으로 -)

  • Nam, Yun-Ja;Lee, Hyoung-sook;Jo, Yeong-A
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.18 no.1
    • /
    • pp.43-56
    • /
    • 1994
  • The Purpose of this study was to utilize of CAD System in pattern making process for women's apparel. The automation by the use of CAD System provides the higher accuracy and efficiency in pattern making process. AccuMark 300 System was used. for .this study. The results from this study were as follows . 1. New size spec chart and grading pitch chart were developed based on the data analysis and fitting tests for female college students. 2. New jacket block was developed based on the torso length sloper 3. Automatic grading of jacket block have been developed by creation and modification of grading rules of block pattern. 4. Pattern Design Systyem(P/D/S) were enabled to be constructed directly form a block pattern by modifications to existing styled pattern. 5. Original master pattern was generated by P/D/S menu option. 6. Production pattem added seam allowance, notchs was generated by P/D/S menu option. 7 Interative maker making process have enabled to save a wide range of time and space. 8. Measurement of garment by P/D/S measuring tools is to utilize in garment costing, quality control.

  • PDF

Precision Surface Profiling of Lens Molds using a Non-contact Displacement Sensor (비접촉 변위센서를 이용한 초소형렌즈 정밀금형 형상측정)

  • Kang, Seung-Hoon;Jang, Dae-Yoon;Lee, Joohyung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.2
    • /
    • pp.69-74
    • /
    • 2020
  • In this study, we proposed a method for surface profiling aspheric lens molds using a precision displacement sensor with a spatial scanning mechanism. The precision displacement sensor is based on the confocal principle using a broadband light source, providing a 10 nm resolution over a 0.3 mm measurable range. The precision of the sensor, depending on surface slope, was evaluated via Allan deviation analysis. We then developed an automatic surface profiling system by measuring the cross-sectional profile of a lens mold. The precision of the sensor at the flat surface was 10 nm at 10 ms averaging time, while 200 ms averaging time was needed for identical precision at the steepest slope at 25 deg. When we compared the measurement result of the lens mold to a commercial surface profiler, we found that the accuracy of the developed system was less than 90 nm (in terms of 3 sigmas of error) between the two results.