• Title/Summary/Keyword: Automatic Level Control

Search Result 314, Processing Time 0.027 seconds

An Efficient Control Sy7stem for Intelligent LED Indoor Lighting (지능형 LED 실내조명을 위한 효율적인 제어 시스템)

  • Hong, Sung-Il;Yoon, Su-Jeong;Lin, Chi-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.6
    • /
    • pp.235-243
    • /
    • 2014
  • In this paper, we propose an efficient control system for intelligent LED indoor lighting. The proposed an efficient control system for intelligent LED indoor lighting were included to elements such as daylight intensity measured through the PIR sensor and illuminance sensor at lighting style by the schedule defined and the occupancy detection. And it was controlled lighting through to the wireless sensor network, and was designed for the energy savings. Also, the lighting control of indoor lighting based on occupancy detection detect fine movements using a PIR sensor. And an unnecessary lighting intensity control of the window-side and the inside were controlled according to daylight level measurement result using the light sensor. In daylight inflow many case, the window-side lighting was to automatically darker, and in daylight inflow less case, was designed to be automatically bright. The efficiency validate results of an efficient control system for intelligent LED indoor lighting, the brightness of the indoor light were to maximize the energy saving by controlling in real time when entering as indoor a little that external lighting or daylight.

Serum Tumor Markers, Hypoxia-Inducible factor-1α HIF-1α and Vascular Endothelial Growth Factor, in Patients with Non-small Cell Lung Cancer Before and after Intervention

  • Liang, Jun;Qian, Ying;Xu, Dan;Yin, Qun;Pan, Hui-Juan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.6
    • /
    • pp.3851-3854
    • /
    • 2013
  • Objective: To explore changes in the serum tumor makers, hypoxia-inducible factor-$1{\alpha}$ (HIF-$1{\alpha}$) and vascular endothelial growth factor (VEGF) level and their relations in patients with non-small cell lung cancer (NSCLC) before and after intervention. Materials and Methods: Forty patients with NSCLC and 40 healthy individuals undergoing physical examination in our hospital provided the observation and control groups. HIF-$1{\alpha}$ and VEGF levels in serum were detected by enzyme-linked immuno-sorbent assay (ELISA) in the observation group before and after intervention and in control group on the day of physical examination, along with serum carcino-embryonic antigen (CEA), neuron-speci ic enolase (NSE) and squamous cell carcinoma antigen (SCC) levels in the observation group with a fully automatic biochemical analyzer. Clinical effects and improvement of life quality in the observation group were also evaluated. Results: The total effective rate and improvement of life quality after treatment in observation group were 30.0% and 32.5%, respectively. Serum HIF-$1{\alpha}$ and VEGF levels in the control group were lower than that in observation group (p<0.01), but remarkably elevatedafter intervention (p<0.01). In addition, serum CEA, NSE and SCC levels were apparently lowered by treatment (p<0.01). Serum HIF-$1{\alpha}$ demonstrated a positive relation with VEGF level (p<0.01) and was inversely related with CEA, NSE and SCC levels (p<0.01). Conclusions: Significant correlations exist between marked increase of serum HIF-$1{\alpha}$ and VEGF levels and decrease of indexes related to hematological tumor markers in NSCLC patients after intervention.

A Study on an Efficient VDES Gain Control Method Conforming to the International Standard (국제 표준 규격에 부합하는 효율적인 VDES 이득제어 방안 연구)

  • Yong-Duk Kim;Min-Young Hwang;Won-Yong Kim;Jeong-Hyun Kim;Jin-Ho Yoo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2022.06a
    • /
    • pp.339-343
    • /
    • 2022
  • In this study, a method for simplifying the structure of the VDES RF receiver, and the gain control method of the receiver to comply with the international standard in this structure was described. The input level of the wanted signal and unwanted signal to the receiver was defined, and when the two signals were input, the saturation state at the ADC was checked at the receiver output. As a result of the simulation by the circuit simulator, it was satisfied that the output power of the receiver was in the SFDR region of ADC with respect to the adjacent channel interference ratio, intermodulation, and blocking level. Through this study, it was found that the structure of th proposed RF receiver conforms to the international standard.

  • PDF

Control of dissolved Oxygen Concentration and Specific Growth Rate in Fed-batch Fermentation (유가식 생물반응기에서의 용존산소농도 및 비성장속도의 제어)

  • Kim, Chang-Gyeom;Lee, Tae-Ho;Lee, Seung-Cheol;Chang, Yong-Keun;Chang, Ho-Nam
    • Microbiology and Biotechnology Letters
    • /
    • v.21 no.4
    • /
    • pp.354-365
    • /
    • 1993
  • A novel control method with automatic tuning of PID controller parameters has been developed for efficient regulation of dissolved oxygen concentration in fed-batch fermentations of Escherichia coli. Agitation speed and oxygen partial pressure in the inlet gas stream were chosen to be the manipulated variables. A heuristic reasoning allowed improved tuning decisions from the supervision of control performance indices and it coule obviate the needs for process assumptions or disturbance patterns. The control input consisted of feedback and feedforword parts. The feedback part was determined by PID control and the feedforward part is determined from the feed rate. The proportional gain was updated on-line by a set of heuristics rules based on the supervision of three performance indices. These indices were output error covariance, the average value of output error, and input covariance, which were calculated on-line using a moving window. The integral and derivative time constants were determined from the period of output response. The specific growth rate was maintained at a low level to avoid acetic acid accumulation and thus to achieve a high cell density. The specific growthe rate was estimated from the carbon dioxide evolution rate. In fed-batch fermentation, the simutaneous control of dissolved oxygen concentration (at 0.2; fraction of saturated value) and specific growth rate (at 0.25$hr^{-1}$) was satisfactory for the entire culture period in spite of the changes in the feed rate and the switching of control input.

  • PDF

System Level Design of Multi-standard Receiver Using Reconfigurable RF Block

  • Kim, Chang-Jae;Jang, Young-Kyun;Yoo, Hyung-Joun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.4 no.3
    • /
    • pp.174-181
    • /
    • 2004
  • In this paper, we review the four receiver architectures and four methods for multi-standard receiver design. Propose reconfigurable RF block can be used for both low-IF and direct conversion architecture. Also, using reconfigurable mixer method, it can be operated at $2{\sim}6$ GHz range for multi-standard receiver. It consists of wideband mixer, filter, and automatic gain control amplifier and to get wide-band operation, $2{\sim}6$ GHz, wide-band mixer use flexible input matching method. Besides, to design multi-standard receiver, LNA bank that support each standard is necessary and it has good performance to compensate the performance of wide-band mixer. Finally, we design and simulate proposed reconfigurable RF block and to prove that it has acceptable performances for various wireless standards, the LNA bank that supports both IEEE 802.11a/b/g and WCDMA is also designed and simulated with it.

The development of Inspection Machine for a blood virus infection (바이러스 감염 판별용 혈액 검사기 개발)

  • Jun, Jae-Min;Seo, Kyu-Tae;Lee, Bo-Hee;Lee, In-Koo;Min, Seung-Ki;Kim, Hak-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.465-467
    • /
    • 2004
  • This paper deals with the design and analysis of automatic virus infection machine, which can be used in blood testing at veterinary hospital. It consists of the mechanical positioning parts and electrical control parts. Two of driving motor and ball screws are used to move the liquid container into the test position and mix the blood on litmus paper. In addition, a thermal controller is installed to keep the container temperature on constant level. The user interface using with a LCD and some keys are supplied with a 8-bit single chip controller. All of the designs issue related with the mechanism and controllers are discussed in detail. Finally the proposed machine is tested in real experiment with the formal processing to judge the virus infection, and also the usefulness of designed algorithm is verified through the experiments.

  • PDF

A Self -Tuning PID Controller for a System with Varying Time Delays (지연시간이 변하는 시스템을 고려한 자기동조 PID 제어기)

  • Lee, Chang-Goo
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.7
    • /
    • pp.475-483
    • /
    • 1988
  • One of the advantages of the well-known PID controller is that it is a sufficiently flexible controller for many applications. But, when the plant parameters and disturbances are unknown or change with time, it is desirable to make automatic tuning of PID controller in order to achieve an acceptable level of performance of the control system. This paper presents a reformulation of the self-tuning pole-zero placement controller subject to some conditions and restrictions. It has the structure of a digital PID controller and is based on Vogel and Edgar's pole-zero placement design method. Various properties of this self-tuning PID controller are described and illustrated by simulation examples.

  • PDF

Automatic acquisition of local fuzzy reasoning rules through DNA coding method (DNA 코딩 방법을 이용한 국소 퍼지 추론규칙의 자동획득)

  • Park, Jong-Gyu;Yun, Sung-Yong;Oh, Sung-Kwon;Ahn, Tae-Chon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.543-545
    • /
    • 1999
  • In this paper, the composition method of global and local fuzzy reasoning concepts is researched for reducing the number of rules, not losing the performance for fuzzy controller. A new method is proposed in details that controls the interaction between global reasoning and local reasoning. In order to automatically acquire and optimize the method, the DNA coding algorithm is introduced to the local fuzzy reasoning of the proposed composition fuzzy reasoning method. The method is applied to the real liquid level control system for the purpose of evaluating the Performance. The simulation results show that the proposed technique can produce the fuzzy rules with higher accuracy and feasibility than the conventional methods.

  • PDF

A Study on the Systems Engineering Management Plan for the Railway Safety Project (철도안전프로젝트에 적용한 시스템엔지니어링 관리계획서 작성에 관한 연구)

  • Choi Yo-Chul;Cho Yun-Ok
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.4 s.35
    • /
    • pp.482-486
    • /
    • 2006
  • The Systems Engineering Management Plan (SEMP) is the primary, top level technical management document for the integration of all engineering activities at the project plan phase. This document defined the activities to plan, control, and perform overall engineering integration. To develop the SEMP for Railway Safety System, several standards are reviewed and analyzed. And then a common requirement for SEMP preparation is derived from the results of analysis. Also, the SEMP example available practically applies to Railway Safety System. In particular, The SEMP focused on controling technical program management has been organized so far, but in this study the detailed contents of SEMP put stress on project management is derived. And it is related to each other between project management and technical engineering management. At the end, to continuously manage the items and contents of the SEMP, a database management and an automatic document generation system is presented using Computer-Aided Systems Engineering (CASE) tool.

A Study on the Systems Engineering Management Plan for the Railway Safety System (철도안전시스템에 적용한 시스템 엔지니어링 관리 계획 작성사례 연구)

  • Choi Yo-Chul;Park Young-Won;Cho Yun-Ok
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.64-69
    • /
    • 2005
  • The Systems Engineering Management Plan (SEMP) is the primary, top level technical management document for the integration of all engineering activities at the project plan phase. This document defined the activities to plan, control, and perform overall engineering integration. To develop the SEMP for Railway Safety System, several standards are reviewed and analyzed. And then a common requirement for SEMP preparation is derived from the results of analysis. Also, the SEMP example available practically applies to Railway Safety System. In particular, The SEMP focused on controling technical program management has been organized so far, but in this study the detailed contents of SEMP put stress on project management is derived. And it is related to each other between project management and technical engineering management. At the end, to continuously manage the items and contents of the SEMP, a database management and an automatic document generation system is presented using Computer-Aided Systems Engineering (CASE) tool.

  • PDF