• 제목/요약/키워드: Automated Measurement

검색결과 374건 처리시간 0.026초

측정 횟수 및 방문 횟수에 따른 혈압 변화 (The Change of Blood Pressure according to the Number of Measurements and the Number of Visits)

  • 박지은;이민희;류연희;류연;정희정;홍상훈;이승덕;김남권;최선미
    • 한국한의학연구원논문집
    • /
    • 제18권3호
    • /
    • pp.111-118
    • /
    • 2012
  • Objective : The aim of this study was to investigate the number of measurements and visits for blood pressure measurement. We also analyzed the change of blood pressure based on the measurement method and measurement interval. Methods : Data of three clinical trials evaluating the effect of acupuncture, moxibustion, and qigong for pre and mild essential hypertension were used. Blood pressure was measured 3 times each visit with 1 or 5 minutes interval, and it was checked until $3^{rd}$ visit. Two trials used sphygmomanometer and another one trial used automatic device for blood pressure measurement. Results : The mean difference between $1^{st}$ and $2^{nd}$, and $2^{nd}$ and $3^{rd}$ measurement were significant in systolic (p<0.001) and diastolic blood pressure (p<0.001). However, in automated measurement or measuring with 1 minute interval, the difference between $2^{nd}$ and $3^{rd}$ was not significant. The mean of $1^{st}$ and $2^{nd}$ measurements was also significantly different from the mean of all three measurements in both systolic (p<0.001) and diastolic blood pressure (p<0.001). While the difference between each visit was not significant in diastolic blood pressure, the systolic blood pressure difference was significant between $1^{st}$ and $2^{nd}$ visit in automated and manual measurement. Conclusion : The mean of two measurements and three measurements were significantly different. The change of blood pressure was different according to the method and interval of blood pressure measurement.

건설진도율 산정을 위한 진도관리단위에 관한 연구 (Standardized Progress Measurement Package)

  • 정영수;강승희;진상윤;김예상;정문헌;박순찬
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2004년도 제5회 정기학술발표대회 논문집
    • /
    • pp.565-570
    • /
    • 2004
  • 건설진도율은 프로젝트 성과 측정 및 진행관리의 중요한 요소 중의 하나로서 이용되고 있으나, 작업 진도 산출기준 및 방법이 현장 상황에 따라 다르게 운영되기 때문에 진도 산출의 정확성이 각 현장 특성에 크게 의존되고 있는 실정이다. 즉, 현장별 공사 진행 상태 비교 시 상당한 오류-가 발생될 수 있으며, 그 신뢰도 역시 매우 떨어질 수 있다는 것을 의미한다 따라서 본 연구에서는 모든 현장의 공사 진행 상태를 같은 기준으로 파악이 가능한 전사 차원으로서의 공통 기준인 진도관리단위 및 평가요소를 정의하며, 이와 더불어 진도관리단위 적정성 평가 방안 및 진도산정모델의 프로세스를 제안하고자 한다.

  • PDF

연약지반 계측 정보관리 및 자동분석.재설계 시스템 개발 (A Development of Automated Monitoring Technique and Feedback Design System for Embankment on Soft Ground)

  • 한영철;윤동덕;김주용
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.103-108
    • /
    • 1999
  • This paper describes development of a new automated real-time system which preforms measurement data reduction and management, geotechnical backanalysis, and feedback design for embankment construction on soft ground. Such a system can be an effective, useful and economical tool for managing a large site development on soft ground. The system consists of data base system to characterize soil properties and identify instrumentation, analysis system for ground behavior and stability coupled with automatic monitoring system, and feedback design system which is a new technique to reflect the analysis of measured ground behavior against original design.

  • PDF

Development of an Automated Diffusion Scrubber-Conductometry System for Measuring Atmospheric Ammonia

  • Lee, Bo-Kyoung;Lee, Chong-Keun;Lee, Dong-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권6호
    • /
    • pp.2039-2044
    • /
    • 2011
  • A semi-continuous and automated method for quantifying atmospheric ammonia at the parts per billion level has been developed. The instrument consists of a high efficiency diffusion scrubber, an electrolytic on-line anion exchange device, and a conductivity detector. Water soluble gases in sampled air diffuse through the porous membrane and are absorbed in an absorbing solution. Interferences are eliminated by using an anion exchange devises. The electrical conductivity of the solution is measured without chromatographic separation. The collection efficiency was over 99%. Over the 0-200 ppbv concentration range, the calibration was linear with $r^2$ = 0.99. The lower limit of detection was 0.09 ppbv. A parallel analysis of Seoul air over several days using this method and a diffusion scrubber coupled to an ion chromatography system showed acceptable agreement, $r^2$ = 0.940 (n = 686). This method can be applied for ambient air monitoring of ammonia.

Improved prediction of Pump Turbine Dynamic Behavior using a Thoma number dependent Hill Chart and Site Measurements

  • Manderla, Maximilian;Kiniger, Karl N.;Koutnik, Jiri
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권2호
    • /
    • pp.63-72
    • /
    • 2015
  • Water hammer phenomena are important issues for the design and the operation of hydro power plants. Especially, if several reversible pump-turbines are coupled hydraulically there may be strong unit interactions. The precise prediction of all relevant transients is challenging. Regarding a recent pump-storage project, dynamic measurements motivate an improved turbine modeling approach making use of a Thoma number dependency. The proposed method is validated for several transient scenarios and turns out to improve correlation between measurement and simulation results significantly. Starting from simple scenarios, this allows better prediction of more complex transients. By applying a fully automated simulation procedure broad operating ranges of the highly nonlinear system can be covered providing a consistent insight into the plant dynamics. This finally allows the optimization of the closing strategy and hence the overall power plant performance.

Development of an automated system for water-hydraulic and leakage test of pressure vessels

  • Kim, Dong-Soo;Lee, Won-Hee
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제5권1호
    • /
    • pp.55-59
    • /
    • 2004
  • This study developed a fully automated test system for pressure vessels, containing such as oxygen, nitrogen, which is widely used in many industries. The pressure vessel test has three major parts including weight measurement test, water-hydraulic test and leakage test followed by cleaning and drying. The control system for these tests consists of three parts: a PLC, a monitoring system and a database management system. The PLC oversees overall control of test machines, while the monitoring system measures and displays weight, pressure, flow etc. for every situations, and the database management system stores test data. These three modules are designed to communicate with one another at 1 Hz frequency alerting problematic situations to the operator. The system has gone through actual field tests for verification of performances.

IVHS에서의 Fuzzy 논리를 이용한 차량의 차선 변경 제어 (Control of Lane Change of Vehicles using Fuzzy Logic for the Intelligent Vehicle Highway System(IVHS))

  • 임형순;김명중;이창구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.465-467
    • /
    • 1998
  • A lane change maneuver is a part of lateral control of an automated highway system. Assuming no direct measurement of its position during transition from one lane to another. A vehicle is controlled to follow the virtual desired trajectory using only on-board sensors. This paper investigates the development of a fuzzy controller for automated lateral control during emergencies. The performance of the fuzzy controller is presented at 20m/s for a step lane change and a double lane change. The robustness of fuzzy controller is investigated with respect to change in tire parameters and the number of passengers.

  • PDF

2차원 영상 정보를 이용한 3차원 위치 측정 알고리즘 개발 (Development of a 3-D Position Measurement Algorithm using 2-D Image Information)

  • 이준호;정성호;김동현
    • 한국기계가공학회지
    • /
    • 제12권5호
    • /
    • pp.141-148
    • /
    • 2013
  • There are several problems in the conventional 2-D image processing and 3-D measurement systems. In the case of the 2-D image processing system, it is not possible to detect elevation data. In a 3-D measurement system, it requires a skillful operator and a lot of time for measuring data. Also, there exist data errors depending on operators. The limitation of detecting elevation data in the 2-D image processing system can be solved by laser diodes. In this study an algorithm that measures the accurate data in a subject face to be detected by combining laser diodes and a commercial CCD camera is developed. In the development process, a planar equation is developed using laser diodes and the equation is used to obtain a normal vector. Based on the results, an algorithm that transforms commercial CCD camera coordinates to 3-D coordinates is proposed. The completed measurement method will be applied to replace a manual measurement system for vehicle bodies and parts by an automated system.

소프트웨어 품질평가 도구(ESCORT)의 설계 및 구현 (Development of Software Quality Assessment Tool)

  • 양해술;권기현;이하용;조영식;이용근;박정호;허태경
    • 한국정보처리학회논문지
    • /
    • 제2권2호
    • /
    • pp.185-198
    • /
    • 1995
  • 본 연구는 소프테워어의 품질을 평가하기 위한 소프트웨어 품질평가 도구의 개발 에 관한 것으로 소프트웨어 품질을 평가하기 위한 체계를 구축하고 소프트웨어 품질 평가 활동을 지원하는 소프트웨어 품질평가도구를 개발하는 것을 목적으로 한다. 소 프트웨어 품질평가 체계는 GQM(Goal-Question-Metrics) 방법론에 의거하여 프로그램의 기능성, 유지보수성, 복잡성 및 객체지향성에 대한 부분을 포함하는 체계로 구성한다. 또한 소프트웨어 품질평가 도구는 개발자, 구매자 및 이용자간의 주관적인 요소를 배 제한 형태로 자동화된 평가를 행하는 것으로 소프트웨어 분석 시스템과 분석 과정을 일관성있게 지원하는 사용자 인터페이스에 대한 부분으로 구분된다. 본 논문의 목적은 소프트웨어 품질을 소프트웨어 개발 중이나 개발 완료후에 평가하여 소프트웨어 개발 비용과 유지보수 비용을 감소함으로써 소프트웨어의 생산성을 향상시키는 것이다.

  • PDF

영상 및 NFC 기반 실시간 시약 계량 등록 시스템 (Image and NFC based Real Time Reagent Measurement and Registration System)

  • 이근우;정상호;정회경
    • 한국정보통신학회논문지
    • /
    • 제23권6호
    • /
    • pp.652-658
    • /
    • 2019
  • 사물인터넷을 이화학, 약학, 생물학 및 의학 등 다양한 연구실험분야에 적용한 경우 다양한 센서와 기기를 부착하여 지능적으로 연구장비 및 환경을 모니터링하고 제어함으로써 연구실험자의 안전성과 편의성을 증대시킬 수 있다. 시약의 정확하고 편리한 기록관리 및 실험과정의 연구이력과 근거, 역추적성 등을 위해서는 실시간 시약 계량 및 등록의 연구지원 자동화 서비스를 제공해야 한다. 현재 기존 시약관리방법은 전산 관리방법을 이용하지만 시약등록과 관리가 일체화된 자동화가 많이 이루어져 있지 않다. 또한 수기에 의한 기록 관리가 대부분으로 실험에 대한 기록오류 및 많은 시약에 대한 계량 및 등록에 대한 소요시간이 큰 점 등 번거로움과 문제점들이 많다. 이에 본 논문에서는 영상인식 및 NFC(Near Field Communication) 방식에 의한 시약 등록과 동시에 전자저울로 계량 측정된 시약정보를 자동으로 관리할 수 있는 IoT 기반 실시간 시약 계량 및 등록 방법을 연구하였다.