측정 횟수 및 방문 횟수에 따른 혈압 변화

The Change of Blood Pressure according to the Number of Measurements and the Number of Visits

  • 박지은 (한국한의학연구원 의료연구본부 침구경락연구그룹) ;
  • 이민희 (한국한의학연구원 의료연구본부 침구경락연구그룹) ;
  • 류연희 (한국한의학연구원 의료연구본부 침구경락연구그룹) ;
  • 류연 (한국한의학연구원 의료연구본부 침구경락연구그룹) ;
  • 정희정 (한국한의학연구원 의료연구본부 침구경락연구그룹) ;
  • 홍상훈 (동의대학교 한의과대학 내과학교실) ;
  • 이승덕 (동국대학교 한의과대학 침구학교실) ;
  • 김남권 (원광대학교 한의과대학 안이비인후피부과) ;
  • 최선미 (한국한의학연구원 의료연구본부 침구경락연구그룹)
  • Park, Ji-Eun (Department of Medical Research, Korea Institute of Oriental Medicine) ;
  • Lee, Min-Hee (Department of Medical Research, Korea Institute of Oriental Medicine) ;
  • Ryu, Yeon-Hee (Department of Medical Research, Korea Institute of Oriental Medicine) ;
  • Liu, Yan (Department of Medical Research, Korea Institute of Oriental Medicine) ;
  • Jung, Hee-Jung (Department of Medical Research, Korea Institute of Oriental Medicine) ;
  • Hong, Sang-Hoon (Department of Internal Medicine, College of Oriental Medicine, Dongeui University) ;
  • Lee, Seung-Deok (Department of Acupuncture and Moxibustion, College of Oriental Medicine, Dongguk University) ;
  • Kim, Nam-Kwen (Sanbon Oriental Medical Center, Wonkwang University) ;
  • Choi, Sun-Mi (Department of Medical Research, Korea Institute of Oriental Medicine)
  • 투고 : 2012.10.31
  • 심사 : 2012.11.29
  • 발행 : 2012.12.31

초록

Objective : The aim of this study was to investigate the number of measurements and visits for blood pressure measurement. We also analyzed the change of blood pressure based on the measurement method and measurement interval. Methods : Data of three clinical trials evaluating the effect of acupuncture, moxibustion, and qigong for pre and mild essential hypertension were used. Blood pressure was measured 3 times each visit with 1 or 5 minutes interval, and it was checked until $3^{rd}$ visit. Two trials used sphygmomanometer and another one trial used automatic device for blood pressure measurement. Results : The mean difference between $1^{st}$ and $2^{nd}$, and $2^{nd}$ and $3^{rd}$ measurement were significant in systolic (p<0.001) and diastolic blood pressure (p<0.001). However, in automated measurement or measuring with 1 minute interval, the difference between $2^{nd}$ and $3^{rd}$ was not significant. The mean of $1^{st}$ and $2^{nd}$ measurements was also significantly different from the mean of all three measurements in both systolic (p<0.001) and diastolic blood pressure (p<0.001). While the difference between each visit was not significant in diastolic blood pressure, the systolic blood pressure difference was significant between $1^{st}$ and $2^{nd}$ visit in automated and manual measurement. Conclusion : The mean of two measurements and three measurements were significantly different. The change of blood pressure was different according to the method and interval of blood pressure measurement.

키워드

참고문헌

  1. Whitworth JA. 2003 World Health Organization(WHO)/International Society of Hypertension (ISH) statement on management of hypertension. J Hypertens. 2003;21(11):1983-1992. https://doi.org/10.1097/00004872-200311000-00002
  2. Chobanian AV, Bakris GL, Black HR, Cushman WC, Green LA, Izzo JL et al.. Seventh report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure. Hypertension. 2003;42(6):1206-1252. https://doi.org/10.1161/01.HYP.0000107251.49515.c2
  3. Pickering TG, Hall JE, Appel LJ, Falkner BE, Graves J, Hill MN, et al.. Recommendations for blood pressure measurement in humans and experimental animals: Part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Hypertension. 2005;45(1):142-161. https://doi.org/10.1161/01.HYP.0000150859.47929.8e
  4. Brueren MM, Petri H, van Weel C, van Ree JW. How many measurements are necessary in diagnosing mild to moderate hypertension? Family practice. 1997;14(2):130-135. https://doi.org/10.1093/fampra/14.2.130
  5. Youn CH, Kwon TJ, Kim DH, Lee JB. The variability of blood pressure according to the number of measurements for diagnosis of hypertension. J Korean Acad Fam Med. 2002;23(1):33-39.
  6. Ogedegbe G, Pickering T. Principles and techniques of blood pressure measurement. Cardiology clinics. 2010;28(4):571-586. https://doi.org/10.1016/j.ccl.2010.07.006
  7. Vera-Cala LM, Orostegui M, Valencia-Angel LI, Lopez N, Bautista LE. Accuracy of the Omron HEM-705 CP for blood pressure measurement in large epidemiologic studies. Arq Bras Cardiol. 2011;96(5):393-398. https://doi.org/10.1590/S0066-782X2011005000038
  8. Myers MG, Godwin M, Dawes M, Kiss A, Tobe SW, Grant FC, et al.. Conventional versus automated measurement of blood pressure in primary care patients with systolic hypertension: randomised parallel design controlled trial. BMJ. 2011;342:d286. https://doi.org/10.1136/bmj.d286
  9. Wong WC, Shiu IK, Hwong TM, Dickinson JA. Reliability of automated blood pressure devices used by hypertensive patients. J R Soc Med. 2005;98(3):111-113. https://doi.org/10.1258/jrsm.98.3.111
  10. Lee K, Choi J, Lee J, Shin Z, Jung J, Sohn J, et al.. Evaluation of Correlation between Automatic Oscillometric Sphygmomanometer and Standard Korokoff Auscultatory Sphygmomanometer. Korean Circulation Journal. 1997;27(5):501-507. https://doi.org/10.4070/kcj.1997.27.5.501
  11. Figueiredo D, Azevedo A, Pereira M, de Barros H: Definition of hypertension: the impact of number of visits for blood pressure measurement. Revista portuguesa de cardiologia : orgao oficial da Sociedade Portuguesa de Cardiologia = Portuguese journal of cardiology : an official journal of the Portuguese Society of Cardiology. 2009;28(7-8):775-783.
  12. The Korean Society of Hypertension. Blood pressure monitoring guidelines. 2007.