• Title/Summary/Keyword: Autogas

Search Result 4, Processing Time 0.02 seconds

A Comparative Study on the Safety Management Status of LP Gas Fueled Vehicles in Korea and Foreign Countries (LP가스 연료사용 자동차의 국내외 안전관리현황 비교 연구)

  • Tak, Song-Su;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.2
    • /
    • pp.49-56
    • /
    • 2009
  • This thesis suggests ways for ensuring the safety of domestic autogas (liquefied petroleum gas) vehicles by conducting comparison and analysis on the status of market diffusion and safety management scheme in foreign countries as well as in Korea. According to the result of the survey on the status of domestic autogas safety management, the national scheme to secure the safety of autogas vehicles seems neither well-organized nor sufficiently-controlled. Actually, the gas leakage check-ups conducted for 5,000 autogas cars revealed that about 4 percent of them had leakage problems. As a result, it was acknowledged that the autogas safety regulations being operated in advanced countries need to be selectively introduced for the domestic autogas industry. Consequently, in line with the recent permission to use autogas as a fuel for subcompact cars etc., this thesis is recommending some methods to enhance the safety management scheme for autogas cars such as the amendment of facility regulations including the ventilation of underground parking lots, mandatory attachment of labels claiming autogas cars and indicating periodical inspections etc.

  • PDF

A Survey of Autogas Car Driver's Attitude on Safe Driving (LPG 자동차 안전운행을 위한 운전자 의식조사)

  • Tak, Song-Su;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.2
    • /
    • pp.36-40
    • /
    • 2009
  • In this study, we surveyed 544 drivers, who had taken the education course for autogas car drivers, to figure out their safety awareness status including the recognition of hazards of gas leaking from autogas cars and response attitude toward them. As a result of the survey, we found out that 63% of the responders recognized the hazards of gas leakage and 79% preferred parking in the aboveground areas. For the necessity of introducing restrictions on autogas cars parking in underground lots, 58% of all responders answered yes while 71% of the responders aged over fifties and 73% of them who responded to have known the hazards of parking in underground answered in the affirmative. Furthermore, we found out that responders who had recognized the hazards preferred aboveground parking areas, and the responders who had preferred the aboveground recognized the hazards of parking autogas cars underground and felt the necessity of restricting them from parking in underground relatively high. Through the analysis of these results, we can analyse that the drivers who are aware of the hazards of gas leakage have higher safety attitude for hazards than the other drivers who are not aware of them.

  • PDF

A Study on Contaminants Analysis of Components in LPG Fuel System (LPG 연료계통 부품의 이물질 원인분석에 관한 연구)

  • Kim, Jae-Kon;Yim, Eui Soon;Jung, Choong-Sub
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.3
    • /
    • pp.126-133
    • /
    • 2013
  • Recently, it was reported that complaints about problems being experienced with the performance of vehicles operating on autogas in Korea. The problem was being assumed due to contaminants in LPG and an oily material which was being deposited in vaporizer, injector in LPG fuel system. This study is focused on the analysis of contaminant of automobile parts on LPG fuel system. The sampling points of contaminants are injectors, fuel filters, vaporizer in automobile equipment and it was also investigated by GC-MS, ICP-AES, SIMDIS and EDS. According to results, it was presumed that this contaminants had been analyzed plasticizers with hydrocarbons with high boiling point, Fe from steel corrosion, greases from gas station.

A Study on Liquified Petroleum Gas(LPG) Fuel Quantitative Method using Coriolis Mass Flowmeter (코리올리 질량유량계를 이용한 액화석유가스(LPG) 정량 측정 방법 연구)

  • Park, Tae-Seong;Seong, Sang-Rae;Yim, Eui-Soon;Lee, Joung-Min;Lee, Myung-Sig;Kang, Hyung-Kyu
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.109-122
    • /
    • 2018
  • Domestic LPG meters are being tested for LPG quantification in accordance with the "Measures Act". The LPG meter is re-tested every three years in accordance with the "Enforcement Decree of the Measures Act". The maximum permissible error within the test is within ${\pm}1.0%$, and the tolerance is within ${\pm}1.5%$. For the quantitative measurement of LPG, a hydrometer for LPG, a balance, and a pressure vessel are used. The volume of LPG varies in depending on the temperature and pressure. The current quantitative measurement method of LPG requires the measurement of temperature, pressure and density in order to determine the volume of LPG, respectively, and some equipments are needed accordingly. Coriolis mass flowmeter, on the other hand, measure the mass flow, density and temperature at the same time, and can be converted and calculated to the required values using a computer program, also it is widely applied in the industrial field. In this study, the volume of LPG was measured using a Coriolis mass flowmeter as a basic study of LPG quantitative measurement. In addition, it is shown that it is possible to apply for the LPG quantitative measurement using the Coriolis mass flowmeter by comparing it with the conventional LPG quantitative measurement method.