• Title/Summary/Keyword: Auto drop

Search Result 40, Processing Time 0.045 seconds

Location of Auto Transformer in AC AT Feeding System (교류 AT 급전계통에서의 단권변압기 설치위치의 최적화)

  • Han, M.S.;Lee, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1248-1250
    • /
    • 2002
  • AC AT feeding system is possible to do the long distance feeding due to compensate the voltage drop. Nowaday this is a typical and efficient type all over the world in high speed train and heavy transport capacity. Normally a Auto-transformer is installed at regular internal (5 to 10km) between Substation and Sectioning post, this study is reviewed the voltage drop according to train movement and the optimal location of auto transformer, and provided the efficient feeding configuration.

  • PDF

Shock Resistance Characteristic of Auto Focus Actuator using Finite Element Method and Drop Impact Test (유한요소해석과 낙하충격 실험을 통한 자동초점 액추에이터의 내충격 특성 향상)

  • Shin, Min-Ho;Kim, Hyo-Jun;Park, Gyusub;Kim, Young-Joo
    • Transactions of the Society of Information Storage Systems
    • /
    • v.9 no.2
    • /
    • pp.56-61
    • /
    • 2013
  • The recent increased use of mobile phone has resulted in a technical focusing on reliability issues related to drop performance. Since mobile phone may be dropped several times during their use, it is required to survive common drop accidents. The plastic injection parts such as base stopper and carrier in the encoder type actuator can be broken easily in the actual reliability test of 1.5m free drop. So, we analyzed the shock resistance characteristics of auto focus actuator with variables in the material properties using finite element method. By applying the new resin materials, we can decrease the breakage of plastic injection parts and improve the reliability of mobile phone.

KEY TECHNIQUES IN DEVELOPMENT OF VEHICLE GLASS DROP DESIGN SYSTEM

  • Liu, B.;Jin, C.N;Hu, P.
    • International Journal of Automotive Technology
    • /
    • v.8 no.3
    • /
    • pp.327-335
    • /
    • 2007
  • A new optimization scheme and some key techniques are proposed in the development of a vehicle glass drop design software system. The key issues of the design system are how to regenerate the glass surface and make the vehicle glass drop down along the glass channels. To resolve these issues, a parameterized model was created at first, in which the optimizing method and Knowledge Fusion techniques were adopted the optimized process was then written into the glass drop design system by coding with C language and UGS/Open Application Programme Interface functions etc. Therefore, the designer or engineer can simulate the process of glass dropping along the channels to assess the potential interference between glass and door accessory by using this software system. All of the testing results demonstrate the validity of the optimizing scheme, and the parametric design software effectively solves the key issues on development of the door accessory package.

Deformation of multiple non-Newtonian drops in the entrance region

  • Kim, See-Jo;Kim, Sang-Dae;Youngdon Kwon
    • Korea-Australia Rheology Journal
    • /
    • v.15 no.2
    • /
    • pp.75-82
    • /
    • 2003
  • In this study, with the finite element method we numerically investigate the deformation of liquid drops surrounded by Newtonian or non-Newtonian viscous medium in the axisymmetric contraction flow. 1, 2 or 4 Newtonian or non-Newtonian drops are considered and the truncated power-law model is applied In order to describe non-Newtonian viscous behavior for both fluids. In this type of flow the drop exhibits considerably large deformation, and thus techniques of unstructured mesh generation and auto-remeshing are employed to accurately express the fluid mechanical behavior. We examine the deformation pattern of liquid drops with viscosity dependence different from that of the surrounding medium and also explain their interactions by comparing relative position or speed of drop front.

Study on the upgrade reliability of inkjet droplet measurement using machine vision (머신비젼을 이용한 잉크젯 드랍 측정 시스템의 신뢰성 향상에 대한 연구)

  • Kim, Dong-Eok;Lee, Jun-Ho;Jeong, Seong-Uk
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2007.07a
    • /
    • pp.365-366
    • /
    • 2007
  • Micro jetting drop inspection system is essential to measuring micro drop volume. Measuring pico-liter drop volume is useful for new LCD color filter product process that is based on inkjet printing technology. To upgrade the reliability in drop measurement system, we use the auto focusing & multi drop reiteration & blurring average algorism. First of all we used standard mark for gage R&R in the vision system. Finding the most suitable threshold for multi blurring drop, is the main key of this research. Sensitivity of vision system is a standard in measuring the upgrade system level. So, suitable threshold can upgrade the performance of jetting drop inspection system.

  • PDF

Auto detect inspection system for single lens product of mobile phone camera (휴대폰 카메라용 렌즈단품 이물 자동검사장비)

  • Song C.H.;Jung Y.W.;Bae S.S.;Song J.Y.;Kim Y.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.432-435
    • /
    • 2005
  • The Mega-pixel camera phones become main trends in mobile phone market. The lens modules used in mesa-pixel camera phones need high resolution. One of the main factors of resolution drop is the defects of bare lens. Though there are many advantages in auto-inspection of defects of bare lens, high technical problems take the defect inspections to be done with manual process. In this paper, the type and the source of defects were described and bare lens defect auto-inspection system design was explained. The designed auto-inspection system is composed of illumination optics part, focusing optics part and auto-moving system. With the proposed auto-inspection system, fast and uniform inspection of bare lens can be achieved.

  • PDF

A Study on the Voltage Drop and Earth Leakage Current according to Interval of AT in the AT Feeding Method (AT급전방식에서 AT간격에 따른 전압강하 및 대지누설전류에 대한 연구)

  • Kim, Min-Seok;Choe, Seung-Hyuk;Lee, Jong-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.9
    • /
    • pp.1708-1714
    • /
    • 2011
  • AT feeding system of the electric railway system is installed every about 10km at between the feeder and catenary in parallel and the mid-point of the transformer is connected to the rail The supply voltage of this system is doubled than rolling stock voltage. So the voltage drop is smaller than usual. And the other merit of this system is the decreasing inductive disturbance to the communication line because of the reduced current in rail which runs reversed in a point of view of rolling stock. Also, ATP(Auto Transformer Post) is installed to reduce the voltage drop and to mitigate the inductive disturbance, but still now the proper distance between the ATP and AT feeding system is not established which ranges from 2 to 10[km]. The stable result of simulation(which is set that the end of the line AT is installed) to the voltage drop and inductive disturbance can not analyzes the effect to the supply system due to the ATP. This paper analyzes the effect to the system depending on the location of ATP by forecasting the voltage drop and inductive disturbance.

Applying New Algorithm on AC Auto-Transformer Feeding System under Multiple Trains Operating (AT 교류 철도급전계통 내 다수 열차 운행시 새로운 계통해석 알고리즘 연구)

  • 전용주;추동욱;전명수;임성정;김재철
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.712-719
    • /
    • 2000
  • This paper presents a new algorithm to analyze a train voltages of multi-trains in auto-transformer-fed AC railway systems, using electrical equivalent change. The train current will be divided into circulation and return currents, and these current values are the same. By evaluating each current independently, the result will be more precise. The train current flows through the all auto-transformer corresponding to track impedance. In analyzing the railway system, the algorithm is based on the K.C.L, K.V.L, superposition and circuit separation method. Multi-train's voltages are determined by calculating the catenary voltage at each train's position and adding up these train's voltage drop. Case studies use a field operational data, show that tile proposed method is easily applied.

  • PDF