• Title/Summary/Keyword: Auto M/T

Search Result 54, Processing Time 0.023 seconds

Study of the correlation between proton brain metabolites and perturbed magnetic field variations (양성자 뇌대사물질들과 섭동된 자장변화와의 상관관계에 관한 연구)

  • Baik, H.M.;Choe, B.Y.;Suh, T.S.;Lee, H.G.;Lee, H.K.;Kim, S.E.;Shin, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.121-122
    • /
    • 1998
  • To induce perturbed magnetic field variations in the range of auto prescans permitted, we chose artificially shim values and applied manualy as DC offsets to X, Y, Z gradient amplifiers. The STEAM spectra were obtained from a localized region (8ml) of phantom's center and a Marquart Algorithm is employed to quantify MRS spectra. Results indicated that Creatine (Cr) which had a good correlation between a signal intensity and an area, changed little bit and showed extremly a stabilized state in perturbed magnetic field variations. Therefore, during the MRS experiments, to minimize the SNR reduction by means of unavoidable inhomogeneous magnetic fields, the present study suggested that the quantification method of relative ratios produced by replacing Cr concentration with standard quantify was most desirable.

  • PDF

A Study on the Maneuvering Area of Ship in Moving at Single Point Mooring (SPM 이안 선박의 조종영역에 관한 연구)

  • Kim, Jin-Soo
    • Journal of Korea Ship Safrty Technology Authority
    • /
    • s.23
    • /
    • pp.78-97
    • /
    • 2007
  • SPM, which is an abbreviation of Single Point Mooring, also called as SBM(Single Buoy Mooring), is a special buoy besides the quays of the harbor for mooring ships, and is normally a 3m wide cone or cylinder shaped steel drum fixed underwater so it won't move, and is used for mooring cargo-work at outer port by laid-up ships and large crude oil carrier. The work of VLCC SPM mainly is accomplished on the open sea. On the open sea as a result of meteorological condition and the ocean wave influence, When the weather condition is get bed, peremptorily moving to the safety place, because of the gale and the billow, almost happened frequently, the pilot is unable to go on board and the tug is also unable to be used Now because of the bad weather the VLCC SPM moving to the other safety place frequently happened in the ulsan port. the construction of new harbor, it constructed many break water around SPM. So that it is necessary to propose the new standard about how to maneuvering area actually. The standard for handling ranges of the SPM operations was tested and verified by a simulation.. So that it is necessary to propose the new standard about how to maneuvering area actually.

  • PDF

A STRAIN GAUGE ANALYSIS OF IMPLANT-SUPPORTED CANTILEVERED FIXED PROSTHESIS UNDER DISTAL STATIC LOAD

  • Sohn, Byoung-Sup;Heo, Seong-Joo;Chang, Ik-Tae;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.717-723
    • /
    • 2007
  • Statement of problem. Unreasonable distal cantilevered implant-supported prosthesis can mask functional problems of reconstruction temporarily, but it can cause serious strain and stress around its supported implant and surrounding alveolar bone. Purpose. The purpose of this study was to evaluate strain of implants supporting distal cantilevered fixed prosthesis with two different cantilevered length under distal cantilevered static load. Material and methods. A partially edentulous mandibular test model was fabricated with auto-polymerizing resin (POLYUROCK; Metalor technologies, Stuttgart, Swiss) and artificial denture teeth (Endura; Shofu inc., Kyoto, Japan). Two implants-supported 5-unit screw-retained cantilevered fixed prosthesis was made using standard methods with Type III gold alloy (Harmony C&B55; Ivoclar-vivadent, Liechtenstein, Germany) for superstructure and reinforced hard resin (Tescera; Ivoclar-vivadent, Liechtenstein, Germany) for occlusal material. Two strain gauges (KFG-1-120-C1-11L1M2R; KYOWA electronic instruments, Tokyo, Japan) were then attached to the mesial and the distal surface of each standard abutment with adhesive (M-bond 200; Tokuyama, Tokyo, Japan). Total four strain gauges were attached to test model and connected to dynamic signal conditioning strain amplifier (CTA1000; Curiotech inc., Paju, Korea). The stepped $20{\sim}100$ N in 25 N increments, cantilevered static load 8mm apart (Group I) or 16mm apart (Group II), were applied using digital push-pull gauge (Push-Pull Scale & Digital Force Gauge, Axis inc., Seoul, Korea). Each step was performed ten times and every strain signal was monitored and recorded. Results. In case of Group I, the strain values were surveyed by $80.7{\sim}353.8{\mu}m$ in Ch1, $7.5{\sim}47.9{\mu}m/m$ in Ch2, $45.7{\sim}278.6{\mu}m/m$ in Ch3 and $-212.2{\sim}718.7{\mu}m/m$ in Ch4 depending on increasing cantilevered static load. On the other hand, the strain values of Group II were surveyed by $149.9{\sim}612.8{\mu}m/m$ in Ch1, $26.0{\sim}168.5{\mu}m/m$ in Ch2, $114.3{\sim}632.3{\mu}m/m$ in Ch3, and $-323.2{\sim}-894.7{\mu}m/m$ in Ch4. Conclusion. A comparative statistical analysis using paired sample t-test about Group I Vs Group II under distal cantilevered load shows that there are statistical significant differences for all 4 channels (P<0.05).

The Effect to Inhibiting MIF Activation and Controlling of T Cell Specialization of Ulmus Davidiana Planchon Herbal Acupuncture on TypeII Collagen-induced Arthritis in Mice (유근피 약침이 제2형 Collagen 관절염에서 MIF 활성 억제 및 T세포 분화 조절에 미치는 영향)

  • Lee, Chang-Hwan;Cho, Jae-Yong;Lee, Seung-Deok;Kim, Kyung-Ho;Park, In-Shik;Kim, Kap-Sung
    • Journal of Acupuncture Research
    • /
    • v.25 no.4
    • /
    • pp.81-94
    • /
    • 2008
  • Rheumatoid arthritis(RA) is a general, chronic, inflammatory and auto-immune disease and it can lead to joint edema, pain, stiffness which are caused by an inflammation in synovium covering our joints. Ulmus davidiana Planchon is a traditional herb used for the treatment on various inflammations, gastrointestinal trouble, ENT(ear, nose, and throat) disease, edema, cancer etc. and it works effectively on arthritis as well. In these study to search for the treatment efficacy of Ulmus davidiana Planchon in RA, I measure manifestation of cytokine gene in synoviocyte treated with Ulmus davidiana Planchon herbal acupuncture and in EL-4 cell, manifestation of cytokine gene cell related to T-cell. And after Ulmus davidiana Planchon herbal acupuncture treatment in Collagen induced arthritis(CIA) which has been known by a general model of RA, DBA mice, I observed foot thickness, general shape of synovium, early cytokine induce CIA and, generation and mutation of cytokine related to the control of T-cell specialization. It comes to conclusion as belows. 1. In synovium treated with Ulmus davidiana Planchon herbal acupuncture, there was the decrease in MIF mRNA does-dependently. Incase of CIA mice treated with Ulmus davidiana Planchon herbal acupuncture, there were the decrease in the damage in synovium and generation of the MIF which is related to induction of the early RA cytokine and IL-6 proinflammatory cytokine. 2. In case of EL-4 treated with Ulmus davidiana Planchon herbal acupuncture, there were decrease in the manifestation of the IL-2 mRNA, but the increase in the manifestation of the IL-4 does-dependently. 3. In the synovium of CIA mice treated with Ulmus davidiana Planchon herbal acupuncture, there were the decrease in generation of IL-2, IL-12 and CD-28, but the increase in generation of IL-4. These result suggest that Ulmus davidiana Planchon can block the process of the early RA by Inhibiting MIF activation, and mitigate Rheumatoid Arthritis by controlling Tcell specialization.

  • PDF

A Comparative Study of Patient Dose and Image Quality according to the Presence or Absence of Grid During Chest PA Radiography using an Auto Exposure Control System (자동 노출 조절장치를 사용한 흉부 후·전 방향 방사선 검사 시 격자 유·무에 따른 환자 선량과 영상품질 비교 연구)

  • So-min Lee;Han-yong Kim;Dong-hwan Kim;Young-Cheol Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.573-579
    • /
    • 2023
  • This study compares dose difference between the presence or absence of grid in Chest PA radiography using auto exposure control and compares image quality among presence, absence or virtual grid, and proposes a new clinically useful grid combination for chest radiography. The human body phantom was placed Chest PA position and the dosimeter was placed at T6. The same irradiation conditions and field size were applied. 30 images were obtained in the state in which grid was applied and in the state in which grid was not applied, and an additional 30 images in which the virtual grid was applied to the image without the grid were obtained. Radiation dose was presented to entrance surface dose. The image quality was analyzed by comparing the signal-to-noise and contrast-to-noise ratio. ESD decreased by 48% when the grid was not used, compared to when the grid was used. SNR and CNR increased by 32% and 30% compared to grid use when grid was not used, respectively. In the case of using the virtual grid, it increased by 18% and 16% respectively, compared to the case of using the grid. As a result of this study, it is believed that when using a virtual grid instead of a grid, the quality of the image can be maintained while reducing the patient dose.

Effects of Dose and Image Quality according to Center Location in Lumbar Spine Lateral Radiography Using AEC Mode (자동노출제어장치를 이용한 요추 측면 방사선검사 시 환자 중심 위치 변화가 선량과 화질에 미치는 영향)

  • Jeong, Woon-Chan;Joo, Young-Cheol
    • Journal of radiological science and technology
    • /
    • v.44 no.2
    • /
    • pp.85-90
    • /
    • 2021
  • The purpose of this study is to consider usefulness of using AEC mode and importance of patient center location in L-spine lateral radiography by comparing dose and image quality according to the change of patient center location with using AEC mode or not. In this study, guide wire is attached to the human body phantom's lumbar spine and the lead ruler is attached to the bottom of the wall detector to find out center location in detector. ESD, mAs, and EI were selected as dose factors, and image quality was compared through SNR. With the lumbar spine located center of the detector, dose factors and image quality were compared according to using AEC mode or not. Afterwards, phantom moved 4 cm and 8 cm back and forth and compared dose factors and image quality. The exposure parameters were 85 kVp, 320 mA, x-ray field size 10×17 inch, and the distance between the center X-ray and the detector was fixed at 100 cm. The center X-ray was perpendicular to the fourth lumbar spine and the only bottom AEC chamber was used. All data were analyzed by independent t-test and ANOVA. As a result of this study, with AEC when the center is matched, ESD was 1.31±0.01 mGy, without AEC was 2.12±0.01 mGy. SNR was shown to be 22.81±1.83, and 23.44±1.87 respectively. When the phantom's center moves 4 cm, 8 cm forward, and 4 cm, 8 cm backward, ESD were 1.09±0.004 mGy, 0.32±0.003 mGy, 1.19±0.017 mGy, 1.11±0.006 mGy respectively, SNR were 18.29±0.60 dB, 11.11±0.22 dB, 18.98±0.80 dB, 17.71±0.82 dB. Using AEC in L-spine lateral radiography reduced ESD by 38%, EI by 35%, and mAs by 38%, without any difference in SNR(p<0.05). When the phantom's center moves 4 cm, 8 cm forward, and 4 cm, 8 cm backward, ESD was decreasing each 16%, 75%, 9%, 15%, EI was decreasing each 14%, 77%, 15%, 20%, mAs was decreasing each 15% 75% 9%, 15%. SNR was decreasing each 19%, 51%, 17%, 22%.

A STUDY ON SURFACE ROUGHNESS OF COMPOSITE RESINS AFTER FINISHING AND POLISHING -an Atomic Force Microscope study (연마방법에 따른 복합레진의 활택도에 관한 연군 -Atomic Force Microscope를 이용한 연구)

  • Kim, Hyeong-Seob;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.719-741
    • /
    • 1997
  • This study was undertaken to compare by Atomic Force Microscope the effects of various finishing and polishing instruments on surface roughness of filling and veneering composite resins. Seven composite resins were studied : Silux Plus (3M Dental Products, U.S.A.), Charisma (Heraeus Kulzer, Germany), Prisma THP (L.D.Caulk, Dentsply, U.S.A.), Photoclearfil (Kuraray, Japan), Cesead (Kuraray, Japan), Thermoresin LC (GC, Japan), Artglass (Heraeus Kulzer, Germany). Samples were placed and polymerized in holes (2mm thick and 8.5mm in diameter) machined in Teflon mold under glass plate, ensuring excess of material and moulded to shape with polyester matrix strip. Except control group (Polyester matrix strip), all experimental groups were finished and polishied under manufacturer's instructions. The finishing and polishing procedure were : carbide bur (E.T carbide set 4159, Komet, Germany), diamond bur (composite resin polishing bur set, GC, Japan), aluminum-oxide disc (Sof-Lex Pop-On, 3M Dental Products, U.S.A.), diamond-particle disc (Dia-Finish, Renfert Germany), white stone bur & rubber point( composite finishing kit, EDENTA, Swiss), respectively. Each specimens were evaluated for the surface roughness with Atomic Force Microscope (AutoProbe CP, Park Scientific Instruments, U.S.A.) under contact mode and constant height mode. The results as follows : 1. Except Thermoresin LC, all experimental composite resin groups showed more rougher than control group after finishing and polishing(p<0.1). 2. A surface as smooth as control group was obtained by $Al_{2}O_{3}$ disc all filling composite resin groups except Charisma and all veneering composite resin groups except Thermoresin LC(p<0.05). 3. In case of Thermoresin LC, there were no statistically significant differences before and after finishing and polishing(p>0.1). 4. Carbide bur, diamond bur showed rough surfaces in all composite resin groups, so these were inappropriate for the final polishing instruments.

  • PDF

Report on the Effects Lipemic Specimen in Anti-ds DNA Antibody Test (Anti-ds DNA 항체 검사 시 Lipemic 검체의 영향에 관한 보고)

  • Cheon, Jun Hong;Kim, Whe Jung;Kim, Sung Ho;Moon, Hyoung Ho;Yoo, Seon Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.153-157
    • /
    • 2014
  • Purpose: SLE (systemic lupus erythematosus) is an inflammatory autoimmune disease, characterized by various autoantibody. The detection of Anti double-stranded DNA (Anti-ds DNA) is important in the diagnostics of SLE, and include the American College of Rheumatology (ACR) diagnostic criteria for SLE. Also SLE disease activity and correlativity with the level Anti-ds DNA antibody have been reported and Anti-ds DNA antibody quantitative test is very useful for tracing before and after SLE treatment. When These Anti-ds DNA antibody test (Farr assay: $^{125}I$ labeled ds-DNA and bound Anti-ds DNA antibodies complex in serum is precipitated by ammonium sulfate and used to centrifugation, measured it) inhaled supernatant after centrifugation, a lipemic specimen does not facilitate the formation of precipitate and also occurs situation was inhaled with precipitate. To solve these problems, The Influence of the degree of lipemic specimen was evaluated. Materials and Methods: September 2012 to February 2013, We selected lipemic samples (n=81) of specimen commissioned by Anti-ds DNA antibody test. Lipemic samples were done pre-treatment (high-speed centrifugation: 14,000 rpm 5 mins) used a micro-centrifuge (Eppendorf Model 5415D). At the same time lipemic specimen and pre-treatment samples were performed Anti-ds DNA antibody test (Anti-ds DNA kit, Trinity Biotech, Ireland). Statistical analysis were analyzed Pearson's correlation coefficients and regression and paired t-test, and Difference (%). Results: Experimental group 1 (Lipemic Specimen Anti-ds DNA Ab concentration ${\leq}7IU/mL$) at y=0.368X+4.732, $R^2=0.023$, Pearson's correlation coefficient was 0.154, paired t-test (P=0.003), Difference (%) mean 65.7 and showed a statistically significant difference. Experimental group 2 (Lipemic Specimen Anti-ds DNA Ab concentration ${\geq}8IU/mL$) at y=0.983X+0.298, $R^2=0.994$, Pearson's correlation coefficient showed 0.997, paired t-test (P=0.181), Difference (%) mean -5.53 made no statistically significant difference. Conclusion: Lipemic sample of low Anti-ds DNA Ab concentration (2.5-7 IU/mL) and the result is obtained pre-treatment (high-speed centrifugation: 14,000 rpm 5 mins) were made a significant difference statistically. Anti-ds DNA is one of the primary auto-antibodies present in patients with SLE, and remain an important diagnostic test for SLE. Therefore, we recommend preprocessing (high-speed centrifugation: 14,000 rpm 5 mins) in order to exclude the influence of lipemic specimen.

  • PDF

Design of a Holter Monitoring System with Flash Memory Card (플레쉬 메모리 카드를 이용한 홀터 심전계의 설계)

  • 송근국;이경중
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.251-260
    • /
    • 1998
  • The Holter monitoring system is a widely used noninvasive diagnostic tool for ambulatory patient who may be at risk from latent life-threatening cardiac abnormalities. In this paper, we design a high performance intelligent holter monitoring system which is characterized by the small-sized and the low-power consumption. The system hardware consists of one-chip microcontroller(68HC11E9), ECG preprocessing circuit, and flash memory card. ECG preprocessing circuit is made of ECG preamplifier with gain of 250, 500 and 1000, the bandpass filter with bandwidth of 0.05-100Hz, the auto-balancing circuit and the saturation-calibrating circuit to eliminate baseline wandering, ECG signal sampled at 240 samples/sec is converted to the digital signal. We use a linear recursive filter and preprocessing algorithm to detect the ECG parameters which are QRS complex, and Q-R-T points, ST-level, HR, QT interval. The long-term acquired ECG signals and diagnostic parameters are compressed by the MFan(Modified Fan) and the delta modulation method. To easily interface with the PC based analyzer program which is operated in DOS and Windows, the compressed data, that are compatible to FFS(flash file system) format, are stored at the flash memory card with SBF(symmetric block format).

  • PDF

A Study on Filament Winding Process of A CNG Composite Pressure vessel (CNG 복합용기의 필라멘트 와인딩 공정에 관한 연구)

  • Kim, C.;Kim, E. S.;Kim, J. H.;Choi, J. C.;Park, Y. S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.656-660
    • /
    • 2002
  • The fiber reinforced composite material is widely used in the multi-industrial field where the weight reduction of the infrastructure is demanded because of their high specific modulus and specific strength. Pressure vessels using this composite material in comparison with conventional metal vessels can be applied in the field where lightweight and the high pressure is demanded from the defense and aerospace industry to rocket motor case due to the merits which are energy curtailment by the weight reduction and decrease of explosive damage precede to the sudden explosion which is generated by the pressure leakage condition. In this paper, for nonlinear finite element analysis of E-glass/epoxy filament winding composite pressure vessel receiving an internal pressure, the standard interpretation model is developed by using the ANSYS 5.7.1, the general commercial program, which is verified as the accuracy and useful characteristic of the solution based on Auto LISP and ANSYS APDL. Both the preprocessor for doing exclusive analysis of filament winding composite pressure vessel and postprocessor that simplifies result of analysis have been developed to help the design engineers.

  • PDF