• Title/Summary/Keyword: Auto Exposure

Search Result 91, Processing Time 0.039 seconds

Evaluation of the Usefulness for Air Gap Technique in Digital Magnification Mammography (디지털 유방확대촬영술에서 Air gap technique의 유용성 평가)

  • Kim, Mi-Young
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.101-107
    • /
    • 2014
  • The purpose of this study was investigated optimal exposure condition in digital magnification mammography to decrease radiation dose and increase image quality of the examinee. Auto mode, the average glandular dose is higher than the manual mode. Average glandular dose and image quality were many differences on between grid and air gap technique in auto mode. However, Average glandular dose and signal-to-noise ratio were not different on between grid and air gap technique in manual mode. The signal-to-noise ratio was increased when using the air-gap technique in both mode. According to result, air gap technique may reduce average glandular dose and increase signal-to-noise ratio in digital magnification mammography.

An Analysis on the Status of Inappropriate Material Posting and Personal Information Exposure in Elementary Schools' Web Sites (초등학교 홈페이지에서의 불건전 정보 유통 및 개인정보 노출 실태 분석)

  • Kim, Min-Ki
    • Journal of The Korean Association of Information Education
    • /
    • v.8 no.4
    • /
    • pp.489-500
    • /
    • 2004
  • In this paper, an investigation on internet safety of 244 national or public elementary schools' web sites was performed with two points of view : inappropriate material posting and personal information exposure. The investigation results showed that obscene materials and commercial advertisements were uploaded into the bulletin board(67.2%) and students' personal information such as photograph, address, telephone number were exposed(87.3%). Most of the inappropriate materials were posted by auto-register programs. This problem was occurred due to reckless bulletin board opening and inappropriate management. On the contrary, personal information was exposed by teachers and students. They didn't not care about their personal information. It shows the fact that they have not recognized the danger of personal information exposure. Therefore managing real-name membership and enforcing permission to bulletin board were required to construct and use a safe school web site. Teachers have to understand not only negative effects appeared in a school web site but also latent dangerous factors.

  • PDF

Research on the actual vibration exposure of workers engaging in vibration induced works (진동작업 종사 근로자의 진동노출 실태에 관한 연구)

  • Kim, Kab-Bae;Chung, Eun-Kyo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.178-185
    • /
    • 2012
  • In Korea, researches on the exposure assessment of the hand-transmitted vibration started from the mid-90, however, they were performed in the limited industries such as auto-assembly plants and the evaluation of the vibration was mostly conducted by ISO 5349(1986). Therefore, it was necessary to assess hand-transmitted vibration levels of workplace such as ship building/repairing industry or mining industry where occupational injuries are largely occurred and to evaluate the vibration levels using revised ISO 5349(2001). The SVAN 949 Four Channels Sound & Vibration Analyser was used for the measurement. The workers using a chain saw were exposed to $1.7{\sim}2.8m/s^2$ of daily vibration level. Workers using a rock drill in a coal mining were exposed to the highest vibration acceleration among workers and the levels were $7.1{\sim}10.8m/s^2$. Vibration levels of grinders were different according to the types of grinders. The hand-transmitted vibration of 3 types of grinders were measured and the levels were $3.3{\sim}11.1m/s^2$. Workers using a impact wrench were exposed to $1.5{\sim}1.6m/s^2$ of vibration. Out of 20 kinds of machines, only 4 tools provided the information of vibration acceleration on the instructions. In addition, the current condition of workplaces to control vibration was not much different from the past because there are no vibration exposure limit.

  • PDF

Assessment on the Actual Vibration Exposure of Workers Engaging in Vibration Induced Works (일부 진동작업 종사 근로자의 진동노출 수준 평가)

  • Kim, Kab-Bae;Chung, Eun-Kyo;You, Ki-Ho;Jang, Jae-Kil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.10
    • /
    • pp.940-948
    • /
    • 2012
  • In Korea, researches on the exposure assessment of the hand-transmitted vibration started from the mid-90, however, they were performed in the limited industries such as auto-assembly plants and the evaluation of the vibration was mostly conducted by ISO 5349(1986). Therefore, it was necessary to assess hand-transmitted vibration levels of workplace such as ship building/repairing industry or mining industry where occupational injuries are largely occurred and to evaluate the vibration levels using revised ISO 5349(2001). The SVAN 948 Four Channels Sound & Vibration Analyser was used for the measurement. The workers using a chain saw were exposed to 1.7~2.8 $m/s^2$ of daily vibration level. Workers using a rock drill in a coal mining were exposed to the highest vibration acceleration among workers and the levels were 7.1~10.8 $m/s^2$. Vibration levels of grinders were different according to the types of grinders. The hand-transmitted vibration of 3 types of grinders were measured and the levels were 3.3~11.1 $m/s^2$. Workers using a impact wrench were exposed to 1.5~1.6 $m/s^2$ of vibration. Out of 20 kinds of machines, only 4 tools provided the information of vibration acceleration on the instructions. In addition, the current condition of workplace to control vibration was not much different from the past because there are no vibration exposure limit.

Auto-Guiding System for McDonald Otto Struve Telescope

  • Kim, Eun-Bin;Park, Won-Kee;Kim, Jin-Young;Oh, Hee-Young;Choi, Chang-Su;Pak, Soo-Jong;Im, Myung-Shin;Kuehne, John
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.38.1-38.1
    • /
    • 2010
  • McDonald 2.1m Otto Struve Telescope is located in the Davis Mountains, 450 miles west of Austin, Texas. The telescope was built in 1938, but it is still in demand today. CQUEAN (Camera for QUasar in Early uNiverse) will be attached on this telescope and perform Y-band imaging observations. Dynamics study of the telescope shows that tracking errors are 0.1 arcsec/100sec in declination direction and 0.4 arcsec/100sec in R.A. direction. In order to allow a long exposure (> a few minutes) of a target field, we are making auto-guiding system for the 2.1m telescope. The auto-guiding system of CQUEAN will be connected with TCS of the telescope. The expected number of stars on the CCD field (2.97 square arcminutes) is about 1.2 stars which are brighter than magnitude 17.5 in 2.97 square arcminutes. For more effective observation, we plan to implement moving mechanism in guiding system so that guide CCD camera can see wider off-axis fields.

  • PDF

An Auto-range Fast Bilateral Filter Using Adaptive Standard Deviation for HDR Image Rendering (HDR 영상 렌더링을 위한 적응적 표준 편차를 이용한 자동 레인지 고속 양방향 필터)

  • Bae, Tae-Wuk;Lee, Sung-Hak;Kim, Byoung-Ik;Sohng, Kyu-Ik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.4C
    • /
    • pp.350-357
    • /
    • 2010
  • In this paper, we present an auto-range fast bilateral filter (FBF) for high-dynamic-range (HDR) images, which increases computation speed by using adaptive standard deviations for range filter (RF) of FBF in iCAM06. Many images that cover the entire dynamic range of the scene with different exposure times are fused into one High Dynamic Range (HDR) image. The representative algorithm for HDR image rendering is iCAM06, which is based on the iCAM framework, such as the local white point adaptation, chromatic adaptation, and the image processing transform (IPT) uniform color space. FBF in iCAM06 uses constant standard deviation in RF. So, it causes unnecessary FBF computation in high stimulus range with broad and low distribution. To solve this problem, the low stimulus image and high stimulus image of CIE tri-stimulus values (XYZ) divided by the threshold are respectively processed by adaptive standard deviation based on its histogram distribution. Experiment results show that the proposed method reduces computation time than the previous FBF.

Auto-Exposure Control using Loop-Up Table Based on Scene-Luminance Curve in Mobile Phone Camera (입.출력 특성곡선에 기초한 Look-Up Table 방식의 자동노출제어)

  • Lee, Tae-Hyoug;Kyung, Wang-Jun;Lee, Cheol Hee;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.4
    • /
    • pp.56-62
    • /
    • 2010
  • Auto-exposure control automatically calculates and adjusts the exposure for consecutive input image. Recently, this is usually controlled by the sensor gain, however, unsuitable control causes oscillation of luminance for sonsecutive input images, called as flickering. Also, in mobile phone cameras, only simple information, such as the average luminance value, can be utilized due to coarse performance. Therefore, this paper presents a new real-time AE control method using a Look Up Table(LUT) based on Scene-Luminance curves to avoid the generation of flickering. Prior to the AE control, a LUT is constructed, which illustrates the characteristic of outputs for input patches corresponding to sensor gains. The AE control is first performed by estimating a current scene as a patch using the proposed LUT. A new sensor gain is then estimated using also LUT with previously estimated patch. The entire estimation process is performed using linear interpolation to achieve real-time execution. Based on experimental results, the proposed AE control is demonstrated with real-time, flicker-free.

Evaluation of High Absorption Photoconductor for Application to Auto Exposure Control Sensor by Screen Printing Method (자동노출제어장치 센서적용을 위한 스크린 프린팅 제작방식의 고흡수율 광도전체 특성평가)

  • Kim, Dae-Kuk;Kim, Kyo-Tae;Park, Jeong-Eun;Hong, Ju-Yeon;Kim, Jin-Seon;Oh, Kyung-Min;Nam, Sang-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.2
    • /
    • pp.67-72
    • /
    • 2015
  • In diagnostic radiology, the use of automatic exposure control device is internationally recommended for diagnosis and optimization. However, if exposed to prolonged radiation is a complicated manufacturing process, there is a problem that occurs decrease of various performance overall brightness sensor, which is commercially available conventional. Therefore, in this study, absorption of X-ray is high, and I want to evaluate the AEC applicability of the sensor of the photoconductor-based production has an easy advantage. Experimental results confirms the possibility of fabrication of the sensor through an increase in the SNR, with the detection efficiency superior, accurate turn-off. In addition, it is confirmed that the experimental results of the transmittance and the latent image, Ghost effect by the light conductor does not appear, in the case of a photoconductor with the exception of the PbO, 80% - and it was confirmed good transmittance of 90%. Therefore, excellent mechanical stability and poor performance due to a change of the doping concentration than the existing products that have been put to practical use, the sensor easy photoconductor based, fabrication and can be applied as AEC sensor is expected.

Effectiveness Evalution of 18F-FDG Auto Dispenser (RIID: Radiopharmaceutical Intelligent Dispenser) (18F-FDG 자동분주기 사용에 따른 유용성 평가)

  • Yoo, Moon-Gon;Moon, Jae-Seung;Kim, Su-Geun;Shin, Min-Yong;Kim, Seung-Chul;Lee, Tea-hun;An, Sung-Hyeun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.79-83
    • /
    • 2018
  • Purpose $^{18}F-FDG$, which is commonly used in PET-CT examinations, is low in capacity and it is difficult to keep the amount of radioactivity busy when the specific activity is high, increasing the amount of space dose and radioactive contamination in the distribution room. Therefore, while evaluating the actual dose administered to patients during the manual dispense process, the medical institution intends to assess the usefulness of the auto dispenser by comparing the differences from the actual dose administered to the patient using the new automatic dispense. Materials and Methods From July 2016 to December 2016, 846 patients were manually administered by workers using $^{18}F-FDG$ and $^{18}F-FDG$ 906 patients were using auto dispenser from July 2017 to December 2017. Results Capacity administered to patients during the manual dispense averaged $35.41{\pm}27.79%$ compared to the recommended dose, and the auto dispenser process showed a small difference of $-2.15{\pm}3.99%$ compared to the recommended dose(p<0.05). Conclusion Working people did not have to touch radioactive medicines directly while they were busy in the auto dispenser, and because of the availability of other tasks far away, the time and distance to receive the exposure were also advantageous. It is believed that future use by many medical institutions will not only reduce the dose to patients but also help reduce the exposure dose to workers.

Effect of Automatic Exposure Control Marker with Chest Radiography in Radiation Reduction (자동노출제어를 사용한 X선 흉부촬영에서 AEC 표지자 사용에 따른 환자 피폭선량 감소 효과)

  • Jung, Ji-Sang;Choi, Byoung-Wook;Kim, Sung-Ho;Kim, Young-Mo;Shim, Ji-Na;Ahn, Ho-Sik;Jin, Duk-Eun;Lim, Jae-Sik;Kang, Sung-Ho
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.177-185
    • /
    • 2014
  • This study focused on effects of patient exposure dose reduction with AEC (Auto Exposure Control) marker that is designed for showing location of AEC in X-ray Chest radiography. It included 880 adults who have to use Chest X-ray Digital Radiography system (DRS, LISTEM, Korea). AEC (Ion chambers are posited in top of both sides) are used to every adult and set X-ray system as Field size $17{\times}17inch$, 120kVp, FFD 180cm. 440 people of control group are posited on detector to include both sides of lung field and the other 440 people of experimental group are set to contact their lung directly to Ion chamber (making marker to shows location). Then, measured every DAP and, estimated patient effective dose by using PCXMC 2.0. The average age of control group (M:F=245:195) is 53.9 and the average BMI is 23.4. BMI ranges from under weight: 35, normal range: 279, over weight: 106 to obese: 20 and average DAP is 223.56mGycm2, Mean effective dose is 0.045mSv. The average age of experimental group (M:F=197:243) is 53.7 and the average BMI is 22.7. BMI ranges from under weight: 34, normal range: 315, over weight: 85 to obese: 6 and average DAP is 207.36mGycm2, Mean effective dose is 0.041mSv. Experimental group shows less Mean effective dose as 0.004mSv (9.7%) than control group. Also, patient numbers who got over exposure more than 0.056mSv (limit point to know efficiency of AEC marker) is 65 in control group (14.7%), 19 in experimental group (4.3%) and take statistics with t-Test. The statistical difference between two groups is 0.006. In order to use proper amount of X-ray in auto exposure controlled chest X-ray system, matching location between ion chamber and body part is needed, and using AEC marker (designed for showing location of ion chamber) is a way to reduce unnecessary patient exposure dose.