• Title/Summary/Keyword: Auditory Evaluation

Search Result 186, Processing Time 0.025 seconds

Characteristics of the auditory evaluation of good impression using speech manipulation scripts (말소리 변조 스크립트를 이용한 호감도 청취평가 특징)

  • Kwon, Soonbok
    • Phonetics and Speech Sciences
    • /
    • v.8 no.4
    • /
    • pp.131-138
    • /
    • 2016
  • This study analyzes the characteristics of good impression using speech manipulation scripts and investigates the characteristics of preferred speech voice. Fourty male and female college students participated in this study. They have been exposed to the Gyeongsang dialect spoken by their friends and family for more than 15 years. Two sample voices(1 male and 1 female), considered as giving good impression, were subject to voice analysis. Two students were asked to read the sample paragraph of 'Walking' and their voice samples were analyzed through Praat. The collected speech data were manipulated into 4 different sets by changing pitch level, degree of loudness and speech rate. First, both men and women received good impression more from pitch-lowered sound than from the original one. Second, men tended to receive good impression more from slightly louder voice than from the natural-pitched one. Third, it was shown that men often felt more drowned to a voice at slightly faster speech rate than at the original speech rate. Overall, both male and female listeners favored lower pitch over the original pitch. Men tended to prefer louder voice sound while women preferred less loud one. Men received better impression at a lower speech rate but women at a faster speech rate.

Establishing Evaluation Modifiers for the Annoyance Responses to Heavyweight Impact Noise (Annoyance 반응에 의한 중량충격음 평가척도 구성)

  • Kim, Kyoung-Ho;Jeong, Jeong-Ho;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.917-917
    • /
    • 2003
  • The auditory experiments based on the subjective annoyance responses were undertaken for the establishment of the adverb modifiers of the heavy-weight impact noises. The standard heavy weight impact noise, impact ball noise and adult walking noise were recorded by dummy head at a newly-built apartment and were presented to the subjects by headphones. The levels of the three impact noises were varied from 30 to 60㏈(A) and the subjects matched one of the adverb modifiers to each level of the noise sources. As a result, seven scale modifiers were established and the intervals between the modifiers were found as equal. In addition, it was found that the lower annoyance noise limits for the heavyweight impact, impact ball and walking were 40-45㏈ (L$\sub$I, Fmax. AW), which is 6㏈ lower than in the previous study. The background noise level was as low as 21㏈(A) in the test booth, therefore, the testing conditions need to be concerned for evaluation of floor impact noise.

  • PDF

EVALUATION OF AUDITORY EVOKED POTENTIALS IN WHITE NEW ZEALAND RABBITS WITH SIMULATED SUBDURAL HEMATOMA AND INCREASED INTRACRANIAL PRESSURE (경막혈종 및 뇌내압 증가에 따른 청각 유발전위의 분석)

  • Im, Jae-Joong
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.171-174
    • /
    • 1992
  • Development of a noninvasive intensive care system calls for the use of evoked potentials (EPs), as a means of diagnosing traumatic head-injured patients. The experiment entails surgically plating two subarachnoid bolts and a subdural balloon through the skull to simulate a subdural hematoma. Using various levels of intracranial pressure (ICP) and/or different sizes of balloons, auditory evoked potentials (AEPs) were recorded from a rabbit. Six positive peat latencies ($P_1-P_6$) and five negative peak latencies ($N_1-N_5$) were extracted from an averaged AEP waveform. Multiple regression analyses were performed for determining a relationship between the ICP and AEP peak latencies. The results indicate that a major correlation of changes on AEP peak latencies is due to mechanical forcer of a mass (inflated balloon simulating a hematoma) in the distortion of the brain matter rather than increased ICP.

  • PDF

Evaluation of Stimulus Strategy for Cochlear Implant Using Neurogram (Neurogram을 이용한 인공와우 자극기법 평가 연구)

  • Yang, Hyejin;Woo, Jihwan
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.47-54
    • /
    • 2013
  • Electrical stimulation is delivered to auditory nerve (AN) through the electrodes in cochlear implant system. Neurogram is a spectrogram that includes information of neural response to electrical stimulation. We hypothesized that the similarity between a neurogram and an input-sound spectrogram could show how well a cochlear implant system works. In this study, we evaluated electrical stimulus configuration of CIS strategy using the computational model. The computational model includes stochastic property and anatomical features of cat auditory nerve fiber. To evaluate similarity between a neurogram and an input-sound spectrogram, we calculated Structural Similarity Index (SSIM). The results show that the dynamic range and the stimulation rate per channel influenced SSIM. Finally, we suggested the optimal configuration within the given stimulus CIS. We expect that the results and the evaluating procedure could be employed to improve the performance of a cochlear implant system.

Design Considerations of Auditory Feedback for Enhancing The Usability of Portable Digital Electronic Products (휴대용 디지털 전자제품의 사용성 향상을 위한 청각적 피드백의 고려)

  • Kim, Hyeong-Seok;Park, Min-Yong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.19 no.3
    • /
    • pp.51-60
    • /
    • 2000
  • Non-verbal sound feedback, called earcon, has been used for portable digital electronic products to give appropriate information for the selected function. This study evaluated usability based on user cognition time, error rate, and subjective satisfaction using 20 male and female subjects. The study compared five major user functions from a portable digital electronic product with currently available earcons and the same functions from the product with the new earcons (suggested by this study) which considered user cognitive characteristics, such as loudness, pitch, melody, and length. For subjective evaluation, the study assessed various earcons by subjective impression of sounds using the seven-point rating scales. Major statistical results indicated that the new earcons significantly reduced user error rates and generally improved user performance functions, such as 'play, off, stop, fast forward, and rewind.'

  • PDF

The Effects of Visual Input on the Evaluation of the Acoustics in the Opera Houses (오페라하우스의 객석음향평가에 대한 시지각의 영향)

  • Kim, Su-Yeon;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.772-777
    • /
    • 2004
  • Opera house acoustics were subjectively evaluated in order to investigate the effect of performance stage views on the audience's perception of the seat acoustics in an opera house. Nine seats from an existing opera house were selected for the auditory and/or visual experiments according to seating area distribution and acoustical parameters such as RT and $1-IACC_{E3}$. The recorded music, convolved from the impulse response, was presented with and without visual images of the stage. Subjects were asked to assess the auditory/visual descriptors and overall impression of the music at each seat. The results showed that good visual input helps produce a favorable impression of the acoustics, but a limited view degrades acoustical impression. The acoustical parameters in the tested seats were also investigated to find the relationship between the acoustical parameters and the visual/sound impression.

  • PDF

A Reading Trainning Program offering Visual-Auditory Cue with Noise Cancellation Function (잡음제거 기능을 갖춘 시-청각 단서 제공 읽기 훈련 프로그램)

  • Bang, D.H.;Kang, H.D.;Kil, S.K.;Lee, S.M.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.2 no.1
    • /
    • pp.35-43
    • /
    • 2009
  • In this paper, we introduce a reading training program offering visual-auditory cue with noise cancellation function (RT program) developed by us. The RT program provides some training sentences with visual-auditory cues. Motor speech disorder patients can use the visual and/or auditory cues for reading training. To provide convenient estimation of training result, we developed a noise cancellation algorithm. The function of the algorithm is to remove noise and auditory-cues which are recorded with reading speech at the same time while patient read the sentences in PC monitor. In addition, we developed a function for finding out the first starting time of reading sound after a patient sees a sentence and begins to read the sentence. The recorded speeches are acquired from six people(three male, three female) in four noisy environments (interior noise, white noise, car interior noise, babble noise). We evaluated the timing error for starting time between original recorded speech and processed speech in condition of executing noise cancellation function and not executing. The timing error was improved as much as $4.847{\pm}2.4235[ms]$ as the effect of noise cancellation. It is expected that the developed RT program helps motor speech disorder patient in reading training and symptom evaluation.

  • PDF

Effects of vowel types and sentence positions in standard passage on auditory and cepstral and spectral measures in patients with voice disorders (모음 유형과 표준문단의 문장 위치가 음성장애 환자의 청지각적 및 켑스트럼 및 스펙트럼 분석에 미치는 효과)

  • Mi-Hyeon Choi;Seong Hee Choi
    • Phonetics and Speech Sciences
    • /
    • v.15 no.4
    • /
    • pp.81-90
    • /
    • 2023
  • Auditory perceptual assessment and acoustic analysis are commonly used in clinical practice for voice evaluation. This study aims to explore the effects of speech task context on auditory perceptual assessment and acoustic measures in patients with voice disorders. Sustained vowel phonations (/a/, /e/, /i/, /o/, /u/, /ɯ/, /ʌ/) and connected speech (a standardized paragraph 'kaeul' and nine sub-sentences) were obtained from a total of 22 patients with voice disorders. GRBAS ('G', 'R', 'B', 'A', 'S') and CAPE-V ('OS', 'R', 'B', 'S', 'P', 'L') auditory-perceptual assessment were evaluated by two certified speech language pathologists specializing in voice disorders using blind and random voice samples. Additionally, spectral and cepstral measures were analyzed using the analysis of dysphonia in speech and voice model (ADSV).When assessing voice quality with the GRBAS scale, it was not significantly affected by the vowel type except for 'B', while the 'OS', 'R' and 'B' in CAPE-V were affected by the vowel type (p<.05). In addition, measurements of CPP and L/H ratio were influenced by vowel types and sentence positions. CPP values in the standard paragraph showed significant negative correlations with all vowels, with the highest correlation observed for /e/ vowel (r=-.739). The CPP of the second sentence had the strongest correlation with all vowels. Depending on the speech stimulus, CAPE-V may have a greater impact on auditory-perceptual assessment than GRBAS, vowel types and sentence position with consonants influenced the 'B' scale, CPP, and L/H ratio. When using vowels in the voice assessment of patients with voice disorders, it would be beneficial to use not only /a/, but also the vowel /i/, which is acoustically highly correlated with 'breathy'. In addition, the /e/ vowel was highly correlated acoustically with the standardized passage and sub-sentences. Furthermore, given that most dysphonic signals are aperiodic, 2nd sentence of the 'kaeul' passage, which is the most acoustically correlated with all vowels, can be used with CPP. These results provide clinical evidence of the impact of speech tasks on auditory perceptual and acoustic measures, which may help to provide guidelines for voice evaluation in patients with voice disorders.

Investigating the Adequacy of Rubber Ball Impactor for Floor Impact Noise Evaluation (바닥충격을 평가를 위한 고무공 충격원의 타당성 검토)

  • Jeong, Jeong-Ho;Lee, Sung-Chan;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.468-473
    • /
    • 2002
  • The purpose of this study was to present the possible use of a new standard impactor, the rubber ball(so called, impact ball), and to assess its evaluation method as for heavy-weight impact in multi-story residential buildings, Several experiments were carried out to investigate the effect of the impact on noise propagation in reinforced concrete buildings. Then, the noise from the impact ball was psychoacoustically evaluated. The correlation between the L-value evaluation methods and auditory responses was also investigated. Results show that the ball noise is quite similar to the jumping noise. The noise level of ball is even higher than the bang machine noise, although it has much lower impact force. It was also found that L-indexing seems to bge inappropriate for evaluation of ball noise.

  • PDF

Development of Data Base System for the Human Sensibility Evaluation (감성평가 데이터베이스 구축을 위한 시스템 개발)

  • 이동형;임준묵;배기웅;고복수;강진규;이정훈;남경돈
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.04a
    • /
    • pp.277-281
    • /
    • 2000
  • This paper deals with the construction of database system for the human sensibility evaluation.Recently, although a great deal of research efforts have been made to find out the relationships between products and emotion, the main focus of studies have been on visual and auditory sense and less on human sensibility evaluation. Therefore, we think that continuous and systematic studies on odors and the construction of database system are strongly needed in order to enhance the competitive power of products related to them.In this paper, we developed a human sensibility evaluation database system fitted with the characteristics of our country. 쏜 design procedures of database system are presented. According to these procudures, a new database system is implemented on personal computer using MS Access and Visual and is validated.

  • PDF