• Title/Summary/Keyword: Attachment material

Search Result 267, Processing Time 0.022 seconds

THE EFFECTS OF PASTE TYPE CALCIUM SULFATE ON THE PERIODONTAL HEALING OF 3-WALL INTRABONY DEFECTS IN DOGS (성견 3면 골내낭에서 Paste형 Calcium Sulfate 가 치주조직 치유에 미치는 영향)

  • Hyun, Suk-Ju;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.2
    • /
    • pp.429-455
    • /
    • 2002
  • There are numerous kind of materials and techniques to regenerate the periodontal tissue which has been lost due to destructive periodontal disease, including bone graft material. Many bone graft materials have been reported and among these materials, synthetic material has been developed fin the long time because of its sufficient supply economically. Calcium sulfate which was evaluated as including much calcium, has been used in the clinical field. In the dental field calcium sulfate has been used as bone graft material and Kim reported that improved bone formation and more amount of new attachment after grafting calcium sulfate. but, because calcium sulfate has the problem that it generates the heat in setting period and resolves fast, we need to evaluate the effect of the improved calcium sulfate on periodontal tissue. The present study evaluates the effect of paste type calcium sulfate on the epithelial migration, alveolar bone regeneration, cementum formation and gingival connective tissue attachment in intrabony defect in dogs. Four millimeter deep and four millimeter wide 3-wall defects were surgically created in the mesial or distal aspects of premolars or molars. the test group received paste-type calcium sulfate with a flap procedure and the control group underwent flap procedure only. Histologic analysis after 8 weeks of healing revealed the following results : 1. The length of epithelial growth(the distance from CEJ to the apical end of JE) was 0.52${\pm}$0.26mm in the control and 0.56${\pm}$0.25mm in the test group. there was no statistically significant difference between the two groups. 2. The length of connective tissue adhesion was 1.74${\pm}$1.06mm in the control and 1.28${\pm}$0.57mm in the test group. there was no statistically significant difference between the two groups. 3. The length of new bone was 2.01${\pm}$0.95mm in the control and 2.62${\pm}$0.81mm in the test group. there was no statistically significant difference between the two groups. 4. The length of new cementum was 1.86${\pm}$0.80mm in the control and 2.77${\pm}$ 0.86mm in the test group. there was a statistically significant difference between the two groups.(P<0.01) These results suggest that the use of paste type calcium sulfate in 3-wall intrabony defects has significant effect on new cementum formation , but doesn't have any significant effect on the prevention of junctional epithelium migration and new bone formation. Finally, the paste type calcium sulfate that is used in this study is suggested to be the material that can have a significant effect on the periodontal healing, if its biocompatibility is improved.

Bond Characteristics of Scale According to the Drainage Pipe's Material in Tunnel (터널 배수공의 재질에 따른 스케일 부착 특성에 관한 연구)

  • Chu, Ickchan;Nam, Seunghyuk;Baek, Seungin;Jung, Hyuksang;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.11
    • /
    • pp.51-57
    • /
    • 2011
  • The calcium hydroxide($Ca(OH)_{2}$) which is flowed into the deteriorated tunnel by groundwater is reacted with carbon dioxide($CO_{2}$) and the vehicle's exhaust gas ($SO_{3}$). So its by-products are precipitated at the drainage pipe and these cause the drainage clogging. Most by-products are composed of $CaCO_{3}$ with calcite from a chemical experiment. The purpose of this study is mainly focused on comparison of attachment on each material of drainage pipe (teflon-coated steel pipe, silicon-Oil coated pipe, acrylic pipe and PVC pipe). The test was progressed to disembogue the CaO aqueous solution and tunnel outflow into each of the pipes. The experimental results show that the most produced scale pipe is PVC material and the followings are Acrylic pipe, Silicon-Oil coating pipe and Teflon coating pipe. But the long-term test results showed that teflon-coated steel pipe had a problem with durability because soil which was contained in the tunnel outflow occurred detachment of coating and corrosion of the steel pipe.

Development of the Aircap Module Attached to the Window Through Rolling (롤링을 통한 창호부착형 에어캡 모듈 개발)

  • Her, Ji Un;Seo, Jang Hoo;Kim, Yong Seong;Lee, Heang Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.11
    • /
    • pp.559-569
    • /
    • 2017
  • Various studies examining how to conserve building energy have been conducted recently. From such studies it has been determined that insulation performance of an aircap is viable and therefore aircaps are used as material for improving insulation performance of windows. However, the aircap for improving insulation performance of a window is attached on the front, causing infringement of the prospect right. Therefore, the purpose of this study is to develop an aircap module attached to the window through rolling, conducting performance verification throughfull-scale testbed and verifying its effectiveness. Findings of this study are as follow : 1) The module suggested in this study enables setting of an area wherein the aircap is attached through rolling so that the aircap rolls up using Velcro tape, and an insulation bar is suggested to block the gap between the aircap and window glass. 2) When the aircap is applied to the window, consumption of lighting energy increased during summer and winter by 2.8%~16.4% and 0%~76.2% respectively in comparison to no aircap application, indicating that it is unsuitable for conserving lighting energy. 3) In terms of conserving cooling and heating energy, an advantageous or effective aircap attachment method is the method whereby an aircap is attached to the front surface of a window. However, the method whereby an aircap is attached to a part of a window and where no aircap is attached increases consumption of cooling and heating energy during summer and winter by 6.0%~35.7% and 2.7%~41.6% respectively in comparison to the method wherein an aircap is attached to the front surface of a window. 4) In consideration of conserving cooling, heating and lighting energy, the attachment of an aircap to the front surface of window is the most appropriate method, and it is appropriate to attach the aircap at a position that is 1,500 mm or higher from the floor to secure the prospect right and minimize energy loss.

Effect of Extracelluar Matrix on Cell-Surface Interactions and Growth of Cardiomyocyte(HL-1) (세포외 기질 물질에 따른 심근세포(HL-1)의 성장 연구)

  • Hong, Yoon-Mi;Anwar, Khalid;Kim, Sun-Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.1
    • /
    • pp.83-87
    • /
    • 2010
  • We present here the effect of extracellular matrix (ECM) on the proliferation and physiology of HL-1 cardiac cells. HL-1 cell is from AT-1 mouse atrial cardiomyocyte tumor lineage. HL-1 cell can be serially passaged, yet they maintain the ability to contract which is a promising character of HL-1 cell for the cell based biosensors. HL-1 cells grow up on the ECM which can affect on the attachment and growth of HL-1. In this paper, we discuss HL-1 cell-ECM interactions with three different ECMs and non-treated surface. HL-1 cells are grown for 4 days after seeding then observed their attachment. Also they were immunostained by hoechst and EthD-1 for proliferation, phalloidin for Factin, and DAPI for nuclei. Fibronectin was revealed as the proper ECM material for HL-1 cell culture. This study can provide basic information for understanding the cell-ECM interactions and growth of HL-1 cells.

THE EFFECT OF PERMANENT MAGNET CONNECTING WITH DENTAL IMPLANT ON DISTRIBUTION AND ATTACHMENT OF OSTEOBLAST-LIKE CELL AROUND THE DENTAL IMPLANT (임플랜트에 연결한 영구자석이 임플랜트 주위 뼈모세포의 분포와 부착에 미치는 영향에 관한 연구)

  • Oh Na-Hee;Choi Boo-Byung;Kwon Kung-Rock;Baik Jin;Lee Sung-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.511-518
    • /
    • 2005
  • Purpose: The purpose of this study is to find the effect of rare earth magnet's magnetic field of to the osteoblast around the implant by the means of observation number, and distribution around the implant which is connected to the permanent magnet but not, counted and compared by the number of cells attached to the surface of the implant. Material and method: The permanent magnets, made in the healing cap form, were connected to the implant future, and placed on the culture plate, The osteoblast-like cell: MC3T3-E1 were used for cell culture. As the control group, the implant were connected to normal healing cap, and cultured in the same conditions. 48 hours later, using inverted microscope, the number and distribution of osteoblast around the implant were observed, and 72 hours later, the number of the cells attached to the implant were counted. Results: As a result, the implant connected to the permanent magnet had proved to have a more concentrated cell distribution rate than the control group. The implant connected to the permanent magnet, neck area : which has about 10 gauss magnetic force, had more cells than apex area. The implant connected to the permanent magnet had proven to attach to the osteoblast more productively than control group's implant. Conclusions: This research showed that the magnetic field of the permanent magnet affected the distribution and growth rate of the osteoblast around the implant. In order to support this study, it also had need to monitor the progress of the permanent magnet specifically shown on the neck area, which has10 gauss magnetic force. So after additional research on the distribution and attachment of the cells, and further more, on bone formation, it will be concluded that the clinical applications ,such as immediate loading of implant treatment are possible.

Effects of mixture of fibrin-fibronectin sealant system and calcuim carbonate in periodontal intrabony defects (calcium carbonate와 fibrin-fibronectin sealant system 혼합이식이 치주골내낭 치유에 미치는 영향)

  • Chang, Soo-Jin;Han, Dong-Kwan;Yun, Jeong-Ho;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung;Kim, Chong-Kwan;Chai, Jung-Kiu
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.3
    • /
    • pp.581-591
    • /
    • 2004
  • Calcium carbonate(CC) is biocompatible and gradually absorb to be replaced by bone when implanted into bone tissue. Fibrin-fibronectin sealant system (FFSS) is a product of human-derived plasma. The effect is hemostasis, tissue fixation and adhesion, We expect synergic effects of this two materials in periodontal regeneration. When FFSS was grafted with bone graft in intrabony defects, could be eliminated exofolication of bone graft materials. This study evaluated above materials for periodontal regeneration of 6mm intrabony defects in 36 patients. lap surgery was carried in 14 defects of control group. experimental group 1 was 11 defects grafted with calcium carbonate, experimental group 2 was 11 defects which were grafted with calcium carbonate with FFSS. The clinical parameters evaluated included changes in attachment level, probing depth, gingival recession at 6 months. Postsurgery probing depth reduction was 3.1 ${\pm}$ 0.9mm in control, 3.8 ${\pm}$ 1.6mm in experimental group 1, 4.1 ${\pm}$ 1.1mm in experimental group 2. The result clinically and statistically improved compared to baseline(P<0.01), but the difference found among the groups were not statistically significant. Postsurgery clinical attachment level was 1.6 ${\pm}$ 1.2mm in control, 3.5 ${\pm}$ 2.0mm in experimental group 1, 3.3 ${\pm}$ 1.2mm in experimental group 2. All of the control and experimental groups resulted in a statistically significant reduction from baseline(P<0.01). The reduction of the experimental groups were statistically significant from control(P<0.05). But the change between experimental group 1 and experimental group 2 was not statistically significant. We conclude that mixture of CC and FFSS is effective to periodontal regeneration in intrabony defect.

Effects of SIS/PLGA Porous Scaffolds and Muscle-Derived Stem Cell on the Formation of Tissue Engineered Bone (SIS/PLGA 담체와 근육유래 줄기세포를 이용한 생체조직공학적 골재생)

  • Kim Soon Hee;Yun Sun Jung;Jang Ji Wook;Kim Moon Suk;Khang Gilson;Lee Hai Bang
    • Polymer(Korea)
    • /
    • v.30 no.1
    • /
    • pp.14-21
    • /
    • 2006
  • Tissue engineering techniques require the use of a porous biodegradable/bioresorbable scaffold, which server as a three-dimensional template for initial cell attachment and subsequent tissue formation in both in vitro and in vivo. Small intestinal submucosa (SIS) has been investigated as a source of collagenous tissue with the potential to be used as biomaterials because of its inherent strength and biocompatibility. SIS-loaded poly(L-lactide-co-glicolide)(PLGA) scaffolds were prepared by solvent casting/particle leaching. Characterizations of SIS/PLGA scaffold were carried out by SEM, mercury porosimeter, and so on. Muscle-derived stem cells can be differentiated in culture into osteoblasts, chondrocytes, and even myoblasts by the controlling the culture environment. Cellular viability and proliferation were assayed by 3-(4,5-dimethylthiazole-2-yl)-2,5-diphenyltetrazolium-bromide(MTT) test. Osteogenic differential cells were analyzed by alkaline phosphatase(ALP) activity. SIS/PLGA scaffolds were implanted into the back of athymic nude mouse to observe the effect of SIS on the osteoinduction compared with controlled PLGA scaffolds. Thin sections were cut from paraffin embedded tissues and histological sections were conducted hematoxylin and eosin (H&E), Trichrome, and von Kossa. We observed that bone formatioin of SIS/PLGA hybrid scaffold as natural/synthetic scaffold was better thean that of only PLGA scaffold. It canb be explained that SIS contains various kinds of bioactive molecules for osteoinduction.

The Influence of Attachment Type on the Distribution of Occlusal Force in Implant Supported Overdentures (하악 임플란트 오버덴쳐에서 어태치먼트 종류에 따른 응력분포)

  • Sung, Chai-Ryun;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.375-390
    • /
    • 2009
  • Statement of problem: Implant supported overdenture is accepted widely as a way to restore edentulous ridge providing better retention and support of dentures. Various types of attachment for overdenture have been developed. Purpose: The purpose of this study was to investigate the influence of attachment type in implant overdentures on the biomechanical stress distribution in the surrounding bone, prosthesis and interface between implant and bone. Material and methods: Finite element analysis method was used. Average CT image of mandibular body(Digital $Korea^{(R)}$, KISTI, Korea) was used to produce a mandibular model. Overdentures were placed instead of mandibular teeth and 2mm of mucosa was inserted between the overdenture and mandible. Two implants($USII^{(R)}$, Osstem, Korea) were placed at both cuspid area and 4 types of overdenture were fabricated ; ball and socket, Locator, magnet and bar type. Load was applied on the from second premolar to second molar tooth area. 6 times of finite element analyses were performed according to the direction of the force $90^{\circ}$, $45^{\circ}$, $0^{\circ}$ and unilateral or bilateral force applied. The stress at interface between implants and bone, and prosthesis and the bone around implants ware compared using von Mises stress. The results were explained with color coded graphs based on the equivalent stress to distinguish the force distribution pattern and the site of maximum stress concentration. Results: Unilateral loading showed that connection area between implant fixture and bar generated maximum stress in bar type overdentures. Bar type produced 100 Mpa which means the most among 4 types of attachments. Bilateral loading, however, showed that bar type was more stable than other implants(magnet, ball and socket). 26 Mpa of bar type was about a half of other types on overdenture under $90^{\circ}$ bilateral loading. Conclusions: In any directions of stress, bar type was proved to be the most vulnerable type in both implants and overdentures. Interface stress did not show any significant difference in stress distribution pattern.

Photoelastic stress analysis of the mandibular unilateral free-end removable partial dentures according to the design (하악 편측 유리단 가철성 국소의치의 설계에 따른 광탄성 응력 분석)

  • Park, Cheol-Woo;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.206-214
    • /
    • 2009
  • Statement of problem: There are common clinical cases in which the mandibular first and second molars are missing unilaterally. Purpose: This study was designed to compare and evaluate the magnitude and distribution of stress produced by four kinds of mandibular unilateral free-end removable partial dentures that could be applied clinically in Kennedy class II cases. Material and methods: Four unilateral free-end removable partial dentures using clasp, Konus crown, resilient attachment, and flexible resin were fabricated on the photoelastic models of the Kennedy class II cases. The vertical load of 6㎏ was applied on the central fossa of the first molar of every removable partial denture in the stress freezing furnace and the photoelastic models were frozen according to the stress freezing cycle. After these models were sliced mesio-distally to a thickness of 6mm, the photoelastic isochromatic white and black lines of the sliced specimens were examined with the transparent photoelastic experiment device and photographs were taken with a digital camera. The fringe order numbers at eight measuring points in the photograph were measured with the naked eye. Results: The maximum fringe order number of each sliced specimen and the fringe order number at the residual ridge just below the loading point were in the decreasing order of the unilateral removable partial dentures using flexible resin followed by clasp, resilient attachment, and Konus crown. The fringe order number at the root apex of the second premolar was in the decreasing order of the unilateral removable partial dentures using clasp followed by flexible resin, Konus crown, and resilient attachment. Conclusion: The removable partial denture using Konus crown showed the most equalized stress distribution to the supporting alveolar bone of abutment teeth and residual ridge under the vertical loads. The removable partial denture using flexible resin can be applied to the case that has a better state of residual ridge than abutment teeth.

A study on the expression types and aesthetic formativeness of tassels and fringe in modern bag design (현대 가방 디자인에 나타난 술 장식의 표현유형과 미적 조형성 연구)

  • Kwon, Giyoung
    • The Research Journal of the Costume Culture
    • /
    • v.28 no.4
    • /
    • pp.429-445
    • /
    • 2020
  • The purpose of this study is to provide ideas for the development of bag design by analyzing the expression types and aesthetic formativeness of modern bag design using tassels and fringe given the newtro trend pursuing analog sensitivity in modern society. The methods and scope of this study are as follows. First, the related literature and internet data were reviewed in order to examine the expression types and characteristics of the bags of the West and East. Next, the definition and characteristics of tassel and fringe decoration in terms of the history of clothing were analyzed. Finally, the expression types and aesthetic formativeness of tassels and fringe were derived through the analysis of modern bag design shown in the fashion collections since 2010. The bags decorated with the tassels and fringe bring a variety of visual effects depending on the attachment position, direction and material composition, concentrating the gaze and radiating original style. In this study, the expression of tassels and fringe in modern bag design was classified into three types: surface decoration, shape variability, and object combination. Next, the aesthetic formativeness of modern bag design using tassels and fringe as decorative elements appeared through the mixture of heterogeneous materials and playfulness through imagination, exaggeration through extension of length and volume, and retro characteristics through reinterpretation of tradition. This study is expected to contribute to creative ideas of modern bag design which requires a global sense, which has been used in various cultures for a long time.