Dose Assessment of the Eye of the Operator in the Field of Angiography and Interventional Radiography (혈관조영 및 중재적 시술 분야 내 종사자의 눈에 대한 선량평가)

  • Kim, Jung-hoon;Cho, Yong-In
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.209-216
    • /
    • 2018
  • In the field of angiography and interventional radiology, it is said that the risk of radiation exposure to the eyes is high due to the characteristics of work, but currently divided dose assessment and management are not carried out in reality. Therefore, in this study, in order to evaluate the dose of the operator in the surgical environment and to analyze the shields, firstly, we selected the point where the operator is mainly located, evaluated the exposure dose of the eye after attaching the pocket dosimeter to the lateral angle point of the head and neck phantom, and evaluate shielding effect when wearing lead glasses that is currently commercialized. Secondly, we evaluated the tendency of the exposure dose of the eye and the shielding effect through simulation in the same geometric structure as the actual measurement. As a result, in the case of measurement using a dosimeter, the cumulative dose increased with the increase of the fluoroscopic time, and the tendency was different according to the position of the operator. Simulation results show that the dose distribution of the eye lens in the mathematical phantom is about 1.1 ~ 1.3 times higher than that of the cornea. Also, The protective effect of the lead glasses showed a shielding effect of at least 3.7 ~ 21.4% in each eye.

In vivo Evaluation of a Novel ${\beta}-Lactam$ Antibiotics, YH-487 (새로운 ${\beta}-Lactam$계 항생물질 YH-487의 in vivo 항균활성)

  • Won, Yu-Jung;Kang, Heui-Il;Lee, Jong-Wook;Chung, Dong-Hyo
    • Applied Biological Chemistry
    • /
    • v.40 no.2
    • /
    • pp.157-162
    • /
    • 1997
  • A novel compound, named YH-487, was synthesized by attaching the thiol and aminothiazole residue to $C_3$ and $C_7$ position of 7-aminocephalosporanic acid (7-ACA). The therapeutic efficacy on infected animals, pharmacokinetics in vivo and the effect on intestinal microflora of YH-487 were examined. The pharmacokinetics of YH-487 were similar to that of cefotaxime, a third generation ${\beta}-lactam$ antibiotics, in rat. Upon in vivo administration, YH-487 was predominantly delivered to kidney, and mostly excreted through kidney without making any metabolites. The therapeutic efficacy of YH-487 to animal infected with E. coli was three times and twenty times higher than that of cefotaxime and cefotiam, respectively, In vivo administration of YH-487 to Sprague-Dawley rats significantly decreased the population of intestinal gram negative species such as Enterobacteria and Barteroides. However, no significant changes were obseved in gram positive species such as Lactobacillus, Bifidobacteria and Staphylococcus. In addition, continuous administration of YH-487 did not increase the possibility to induce resistant strains in intestinal microflora.

  • PDF

Performance Evaluation of Domestic Prototype Dose Area Product Meter SFT-1 (국산 프로토타입 면적선량계 SFT-1의 성능평가)

  • Lee, Ho-Sun;Han, Seong-Gyu;Roh, Young-Hoon;Lim, Hyun-Jong;Kim, Jung-Min;Kim, Jong-Uk;Chae, Hyun-Sik;Yoon, Yong-Su
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.435-441
    • /
    • 2016
  • The importance of radiation dose display of medical X-ray equipment was emphasized, while third edition of IEC(International Electrotechnical Commission) 60601 started to apply. The existing medical X-ray equipment selected a method for attaching the DAP(Dose Area Product) meter when the dose display. However, because the DAP meter was dependent on all of the income, And it did not yet produced in Korea. So, we received the support of Seoul R&BD Program(Grants No. C1152055) to produce DAP meter prototype of the Domestically technology. In this study, the performance of this prototype was evaluated by comparing the German company's product Evaluation item was an electronic capture performance, radiation dose dependence, radiation quality dependence, energy transmittance, repeatability, light transmittance of 6 entries. And IEC 60580 was based on this evaluation. Evaluation results were electronic capture performance intrinsic error 9.5%, radiation dose dependence limits of variation 1%, repeatability coefficient of variation 2%, energy transmittance 91% each assessment was passed. However radiation quality dependence limits of variation 29%, light transmittance 55% was less than acceptance criteria.

Application of Wave Resonator to the Field for Controlling Secondary Undulation (부진동의 제어를 위한 공진장치의 현장적용)

  • Lee, Kwang-Ho;Beom, Seong-Sim;Kim, Do-Sam;Choi, Nack-Hoon;Park, Jong-Bae;An, Seong-Wook
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.1
    • /
    • pp.58-65
    • /
    • 2012
  • In this study, to reduce the motion of the vessels resulting from resonance and secondary undulation by long-period waves, numerical review on the control performance of resonator was carried out by attaching the resonator to the established harbor of real waters. In the numerical analysis, CGWAVE MODULE of commercial software SMS(Surface water Modeling System), a finite element model based on 2-dimensional elliptical mild slope equation was applied, and through comparative analysis of the existing experiments and analysis results on the rectangular model ports, the validity of the friction coefficients in which validity and effectiveness of SMS on the secondary undulation analysis is applied was verified. Based on this, the control performance of resonator was confirmed through comparative review of the secondary undulation according to whether or not to attach the resonator to rectangular harbor. In addition, to reduce long-period motion of the moored vessels and the secondary undulation which may occur in Pohang new port, the method to move the resonant period which causes abnormal motion of the vessels to long-term one was discussed through application of the resonators with various sizes, thereby identifying the availability.

Prevalence and Detection of Perkinsus sp. infection in the Manila clams, Ruditapes philippinarum (양식 바지락, Ruditapes philippinarum의 Perkinsus sp. 검출현황과 현장조사)

  • Park, Sung-Woo;Lee, Kyung-Hee;Choi, Dong-Lim
    • Journal of fish pathology
    • /
    • v.18 no.1
    • /
    • pp.49-58
    • /
    • 2005
  • Hemacolor stain, histopathological observation and FTM incubation assay were applied to detect Perkinsus sp. infection in Manila clams (Ruditapes philippinarumi taken from culture beds at Tean and Gochang from March 2002 to August 2003. The prevalency was 100% in the clams from Gochang and 20-70% from Tean. Of the three methods, histopathological observation was the most effective to detect the infection. And the parasites was most abundant in gills. When PCR assay was applied to detect Perkinsus sp. for four species of Mollusc such as manila clam, surf clam (Mactra veneriformis), oyster (Crassostrea gigas) and Thomas' rapa whelk (Rapana venosa) taken from Tean and Gochang from April to July 2004, the parasites were detected from all the species at the infection rates of 95%, 62%, 46.9% and 10% in that order. The infection rate was much higher in the species burrowing in the bottom sediments than those attaching on the tidal rock. The results suggest that Perkinsus sp. may affect almost all the molluscs inhabiting western coastal areas of Korea.

A Study on the Vibration Characteristics of Subway Structure by Train Load (열차 하중에 의한 지하철 구조물의 진동 특성에 관한 연구)

  • Park, Sung Woo;Park, Seung Su;Hwang, In Baek
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.4
    • /
    • pp.107-115
    • /
    • 2011
  • In this study, the vibration analysis of the underground box structures induced train movement is studied. In order to perform these analysis, dynamic data, which was measured when subway is in service, are gained by attaching accelerometers on the structure such as lower beam, lateral wall and upper slab. Also, accelerometers are attached on the lower beams and side walls of the gravel ballast and concrete ballast sections in order to compare vibration due to ballast materials. The vibration results of upper slabs and lower beams reveal that the vibration on the upper slabs is greater than the lower beams. Also, the results of the crack gauge on the upper slab show that crack width dose not change due to vibration, These means that the effect of the vibration on the structure is very limited. In order to evaluate the vibration of the structure, acceleration unit is converted to velocity unit comparing with the existing velocity data gained from the platforms.

An Exploratory Study of Searching Human Body Segments for Motion Sensors of Smart Sportswear: Focusing on Rowing Motion (동작에 따른 피부변화 분석을 통한 동작센서 부착의 최적위치 탐색: 조정 동작을 중심으로)

  • Han, Bo-Ram;Park, Seonhyung;Cho, Hyun-Seung;Kang, Bokku;Kim, Jin-Sun;Lee, Joohyeon;Kim, Han Sung;Lee, Hae-Dong
    • Science of Emotion and Sensibility
    • /
    • v.20 no.1
    • /
    • pp.17-30
    • /
    • 2017
  • Lots of interdisciplinary studies for fusion of high technologes and the other areas of research had been tried in these days. In sports training area, high technologies like a vital sign sensor or an accelerometer were adopted as training tools to improve the performance of the sports players. The purpose of this study is finding the proper locations on the human body for attaching the motion sensors in order to develop a smart sportswear which could be helpful in training players. The rowing was selected as a subject sport as lots of movements of the joint on human body could be seen in rowing motions. The players of rowing could be devided into two weight divisions, the lightweight and the heavyweight. In this study, the change rates of distance between markers on human skin as the players moved were took on the back, the elbow, the hip and the knee area on human body by 3D motion capturing system. The distances between markers and the differences between the lightweight and heavyweight were analyzed. Finally, this study provided the guide lines for designing a motion sensing smart sportswear.

Development of CFS Jacketing Retrofit Method for Rectangular High Strength Concrete Columns by Cross Sectional Shape Modification (4각형 고강도 콘크리트 기둥 단면 변형을 통한 CFS Jacketing 보강방법 개발)

  • Lee, Jong-Gil;Kim, Jang-Ho Jay;Park, Seok-Kyun;Kim, Jin-Keun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.6
    • /
    • pp.153-161
    • /
    • 2010
  • Numerous past studies have shown that safety and serviceability of many concrete infrastructures and buildings built in 1970's have far less strength capacities than their original intended design capacities, thereby requiring repair and strengthening. Currently, aged concrete structures are being repaired using various methods developed in the past. Unfortunately, these methods do not consider the specific conditions that these members are under, but they merely attach repairing materials on the external surface for random strength improvements. Therefore, in order to improve repair and strengthening methods by considering composite behavior between repairing material and structural member, enhanced construction methodologies are needed. Also, the enhanced repairing and strengthening methods must be able to be implemented on structural members constructed using high performance concrete to meet the present construction demand of building mammoth structures. Therefore, in this study, a repairing and strengthening method for retrofitting high strength concrete (HSC) columns that can effectively improve column performance is developed. A square HSC column's cross-sectional shape is converted to an octagonal shape by attaching precast members on the surface of the column. Then, the octagonal column surface is surface wrapped using Carbon Fiber Sheets (CFS). The method allows maximum usage of confinement effect from externally jacketing CFS to improve strength and ductility of repaired HSC columns. The research results are discussed in detail.

A FLUOROSCOPIC STUDY ON THE STABILITY OF SKIN REFERENCE POINTS DURING JAW OPENING AND CLOSING MOVEMENT (방사선 투시를 이용한 개폐구 운동에 따른 수직 고경 계측점의 안정성에 관한 연구)

  • Ahn, Hyung-Jun;Kim, Chang-Whe;Kim, Yung-Soo;Kim, Yong-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.516-530
    • /
    • 1999
  • The current clinical technique for occlusal vertical dimension recording is based on marking the skin reference points on the patient's face and measuring between these points using caliper-like device. And it is difficult to achieve reliable measurements by this technique because of movable soft tissue. The purpose of this study is to reveal the stability of skin reference points by comparing the relative movement between extra-oral skin reference points and intra-oral reference points using X-ray fluoroscope. 10 test subjects were divided into 2 groups : Group I (natural dentition) and Group II (denture-wearer whose vertical dimension was lost) and Group III consists of identical test subjects to Group II with their upper denture removed and record base inserted. Attaching the 3 mm diameter steel ball to nose tip, lower lip, chin and to existing denture (or record base), fluoroscopic examination and recording were taken during 2 jaw opening and closing movements. After subsequent digitization using personal computer, 1219 still pictures with 0.1 second interval were made. Using the 2 dimensional graphic software, measurements between reference points were executed. Dividing the entire jaw movement into 3 ranges (total, 1st half opening, 2nd half opening), rate of movement and relative movement between extra-oral and intra-oral reference points were calculated and statistically analyzed. The results of this study are as follows. 1 Within the same experimental group, no statistical difference was found in the stability of skin reference between lower lip point and chin point during total range of jaw opening and closing movement (p>.05) 2. In the first half range of jaw opening, statistical difference was found between Group I (natural dentition) and Group II (denture wearer) (p<.05) Group I has greater skin reference stability than Group II. 3. In the first half range of jaw opening, statistical difference was found between Group I and Group III (record base wearer) (p<.05). Group I has greater skin reference stability than Group III. 4. In the first half range of jaw opening, no statistical difference was found in the stability of skin reference between Group II and Group III (p>.05). 5. In the second half range of jaw opening, no statistical difference was found in the stability of skin reference between any experimental groups (p>.05). 6. In patients with their occlusal vertical dimension lost, employing other measuring references rather than skin is recommended because of low stability.

  • PDF

Hemisphere Type Lunegerg Lens Antenna with a Reflector (반사판 부착 반구형 르네베르그렌즈 안테나)

    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.6
    • /
    • pp.1006-1014
    • /
    • 2000
  • Hemisphere type Luneberg lens antenna with a reflector(frequency : 9.375 GHz, -3 dB beam width 6$^{\circ}$, diameter 30.3 cm(about 10 A), which is miniaturized and lightweightized by attaching a reflector on a section of half the Luneberg lens antenna, is designed and fabricated on the basis of Luneberg lens antenna from which easy beam pointing is acquired only by movement of 1st radiator. Measurement shows -3dB beamwidth is 6.1$^{\circ}$ in case of E-plane and 5.5$^{\circ}$ in case of H-plane. These are good agreements with expected value. Gain of this antenna is 26dBi(Aperture efficiency for uniform distribution : $\pi$ = 44.97%) which is greater than that of 1st radiator(Rectangular microstrip antenna) by 20.4 dB. And, after calculating the approximated pattern of the 1st radiator, far-field pattern, whose source is the second aperture source farmed from the approximated pattern of the 1st radiator is computed. Comparing this far-field pattern with the expected pattern, a (relatively) good agreement is observed. Circular polarization Luneberg lens antenna is also manufactured by making 1st radiator so that it has the characteristics of LHCP and RHCP radiation. The results are as followings : -3 dB beamwidth 5.8$^{\circ}$ , side lobe level -15.3 dB, isolation between LHCP and RHCP radiation 2543, axial ratio 2 dB bandwidth about 1.4 GHz(14.9%).