• Title/Summary/Keyword: Attached material

Search Result 621, Processing Time 0.025 seconds

Numerical and Experimental Verification of Stress Wave Control Effect in SHPB Experiment using Pulse Shaper (Pulse Shaper를 이용한 SHPB 실험 응력파 제어 효과의 해석 및 실험적 검증)

  • Kim, Y.H.;Woo, M.A.;Kang, B.S.;Kim, J.
    • Transactions of Materials Processing
    • /
    • v.26 no.5
    • /
    • pp.314-322
    • /
    • 2017
  • In the high-speed forming analysis, dynamic material properties considering a high strain rate are required. The split Hopkinson pressure bar (SHPB) experiment was performed for measuring dynamic material properties under high strain rate. The pulse shaping method was used to improve the accuracy of the SHPB experiment. A pulse shaper attached to the front of the incident bar was used for specimen dynamic stress equilibrium through stress wave control. Numerical analysis and SHPB test were performed to verify whether the pulse shaper affects the dynamic stress equilibrium in copper and Al6061 specimens. The results of SHPB test and numerical analysis show that the pulse shaper contributes to the dynamic stress equilibrium. Based on the improved stress equilibrium using a pulse shaper, the flow stress curves for copper and Al6061 materials were obtained at strain rates of 1344.4/sec and 1291.6/sec, respectively.

Architectural Acoustics Design of multipurpose Auditorium in S-high school (S고등학교(高等學校) 다목적(多目的) 강당(講堂)의 건축음향설계(建築音響設計))

  • Ju, Duck-Hoon;Yun, Jae-Hyun;Kim, Jae-Soo
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.436-440
    • /
    • 2008
  • Among those various facilities attached to the school building, the Auditorium is being utilized for not only the Exercise Activity but also for many purposes such as Culture, Public Performance, Education, Assembly and so on. In order to utilize in maximum such function of the multipurpose auditorium, an adequate acoustic design with regard to the Clarity of Voice and Music in accordance with its use-purpose should be accompanied. However, as the most part of multipurpose auditoriums is designed with high ceiling-height by its peculiar character, and due to use of the material of strong reflexibility, it is appearing the defect that excessively exposes the reverberation of sound. In order to make out an optimal acoustic condition within the broad space such as an auditorium, the acoustic characteristics must be considered from the planning stage, however in the most case, those acoustic problems are being settled through the repair works after construction. On such viewpoint, this Study intends to analyze the room acoustic characteristics from the planning stage using a computer simulation based on the blueprint of multipurpose auditorium in S High School located in Gwangju. It is considered that the material analyzed in such way could be practically applied as a fundamental material enables to improve the acoustic capability when a similar broad space is planned hereafter.

  • PDF

Development of method to remove weld scallop and ceramic backing material of wedge type and its application

  • Kang, Sung-Koo;Yang, Jong-Soo;Kim, Ho-Kyung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.7 no.2
    • /
    • pp.315-323
    • /
    • 2015
  • The weld scallop has been used for joining T-bars. There are a lot of weld scallops in shipbuilding. It is difficult to perform scallop welding due to the inconvenient welding position. This results in many problems such as porosity, slag inclusion, etc. In this study, a new method is devised to remove weld scallops by incorporating a Ceramic Backing Material (CBM). The weld scallop is removed by an elongation of the v groove. In order to insert a CBM into the groove without a weld scallop, a wedge-shaped CBM is developed. The top side of the developed CBM is similar to the shape of a general back bead. The bottom surface has a saw-toothed shape for cutting at a suitable length. This can be attached to the root side of a face plate using adhesive tape, just like a general CBM. Welding experiments in normal and abnormal conditions are carried out and the possibility of burn-through is examined. This CBM's applicability to shipbuilding is verified.

A study on the biological characteristics of modified titanium surface (매식체 표면처리에 따른 생물학적 특성에 대한 연구)

  • Kim, Jae-Hyuk;Chung, Chin-Hyung;Lim, Sung-Bin;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.3
    • /
    • pp.453-466
    • /
    • 2008
  • Purpose: The purpose of this research is to study about initial adhesion, proliferation and activation of osteoblast to titanium surface treated with machined, hydroxyapatite coating, resorbable blast material blasting and anodizing method. Material and Methods: After treating the titanium surface of each block with machined, impurities were removed and sterilized. The number of cells attached from cultured osteoblast of respective experimental groups were measured at 1, 4, 7, and 14day and alkaline phosphatase, calcium, and inorganic phosphate concentration of cultured solution was measured. Result: Anodizing group showed the highest rate of cell attachment and proliferation activity. RBM treated group showed the highest increasing on their alkaline phosphatase activity, on the calcium apposition, on inorganic phosphate apposition of 1 and 4 days in cultured osteoblast to compare with other groups. Conclusion: On the basis of these findings, we conclude that surface modification of titanium was profoundly effected on the attachment, proliferation and activation of osteoblast in initial stage osseointegration.

Hydrothermal Synthesis of Cubic Mesocrystal CeO2 for Visible Photocatalytic Degradation of Rhodamine B

  • Yang, Hexiang;Zhou, Mengkai;Meng, Zeda;Zhu, Lei;Chen, Zhigang;Oh, Won-Chun
    • Korean Journal of Materials Research
    • /
    • v.25 no.3
    • /
    • pp.144-148
    • /
    • 2015
  • Cubic mesocrystal $CeO_2$ was synthesized via a hydrothermal method with glutamic acid ($C_5H_9NO_4$) as a template. The XRD pattern of a calcined sample shows the face-centered cubic fluorite structure of ceria. Transmission electron microscopy (TEM) and the selected-area electron diffraction (SAED) pattern revealed that the submicron cubic mesocrystals were composed of many small crystals attached to each other with the same orientation. The UV-visible adsorption spectrum exhibited the red-shift phenomenon of mesocrystal $CeO_2$ compared to commercial $CeO_2$ particles; thus, the prepared materials show tremendous potential to degrade organic dyes under visible light illumination. With a concentration of a rhodamine B solution of 20 mg/L and a catalyst amount of 0.1 g/L, the reaction showed higher photocatalytic performance following irradiation with a xenon lamp (${\geq}380nm$). The decoloring rate can exceed 100% after 300 min.

Mechanical Properties and Wind Energy Harvesting Characteristics of PZT-Based Piezoelectric Ceramic Fiber Composites (PZT계 압전 세라믹 파이버 복합체의 기계적 물성과 압전 풍력 에너지 하베스팅 특성)

  • Lee, Min-Seon;Park, Jin-woo;Jeong, Young-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.2
    • /
    • pp.90-98
    • /
    • 2021
  • Piezoelectric ceramic fiber composite (PCFC) was fabricated using a planar electrode printed piezoelectric ceramic fiber driven in transverse mode for small-scale wind energy harvester applications. The PCFC consisted of an epoxy matrix material and piezoelectric ceramic fibers sandwiched by interdigitated electrode (IDE) patterned polyimide films. The PCFC showed an excellent mechanical performance under a continuous stress. For the fabrication of PCB cantilever harvester, five -PCFCs were vertically attached onto a flexible printed circuit board (PCB) substrate, and then PCFCs were serially connected through a printed Cu circuit. The energy harvesting performance was evaluated applying an inverted structure, which imples its free leading edge located at an open end but the trailing edge at a clamped end, to enhance strain energy in a wind tunnel. The output voltage of the PCB cantilever harvester was increased as the wind speed increased. The maximum output power was 17.2 ㎼ at a resistance load of 200 ㏀ and wind speed of 9 m/s. It is considered that the PCB cantilever energy harvester reveals a potential use for wind energy harvester applications.

Comparison of Materials for Collection of Adhesive Microalgae in Marine Ecosystems (해양 생태계 부착 미세조류 채집을 위한 소재 비교 연구)

  • Jaeyeong Park;Jang-Seu Ki
    • Ocean and Polar Research
    • /
    • v.45 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • Marine microalgae have different collection methods depending on their habitat. In the case of adhesive microalgae, it is difficult to separate organisms from the substrate surface, and contamination is likely to occur during the sampling process. In this study, we analyzed the collection efficiency of adhesive microalgae using three artificial fiber materials (nylon, blend fabric, and viscose rayon). Each fiber showed different fiber diameter and pore characteristics (nylon 26.09 ㎛, blend fabric 56.6 ㎛, viscose rayon 101.3 ㎛). In addition, attached organisms were collected on the surface of artificial substrates at Bukseong Port in Incheon using each tested fiber material. After that, we investigated the population and species composition. The highest number of cells was found in nylon, which was 8 times higher than in the least collected viscose rayon material. In addition, we identified 24 microalgal species from the substrate, demonstrating that the species composition differed from that of surface water. The number of collected microalgae species varied depending on the fiber materials, with nylon containing all the adhesive microalgae. In contrast, only a few microalgae were observed in other fibers. These results suggest that, of the tested fibers, nylon material may be suitable for collecting adhesive microalgae. As a result, this study may be useful for future research on adhesive microalgae.

Analysis of sports knee brace products - Focusing on Chinese websites - (스포츠 무릎보호대 제품 분석 - 중국 웹사이트를 중심으로 -)

  • Xiaoqing Ma;Jeongah Jang
    • The Research Journal of the Costume Culture
    • /
    • v.31 no.5
    • /
    • pp.692-704
    • /
    • 2023
  • This study analyzed 214 sports knee braces found on Chinese websites between October 2022 and November 2022 to assess product type (impact protection material, fastening method, and protection method), material composition, size, weight, and main characteristics. The product type was further categorized according to (1) use of hard guard and soft guard protection method; (2) cover type, strap type, and slip-on type fastening method; and (3) pressure type and support type protection method. It also noted the physical shock protection materials used, including foam (EVA or polyurethane) attached to joints as a buffer material and plastic (TPU or PP) that protects the user's knee from external impacts. The study found that the materials that primarily comprise sports knee braces are a combination of nylon, polyester, and neoprene. Additionally, it found that most sports knee braces available on the market are available in three sizes based on knee circumference: M (35-38cm), L (38-41cm), and XL (41-44cm), while some products are available in one size only. Furthermore, the majority of the 214 products studied weighed 200g, followed by 1,000g. Finally, in terms of product characteristics, many sports knee braces utilize ring-shaped silicone pads to distribute the load pressure on the knees or incorporate sturdy adhesive velcro to improve knee stability.

Attachment of Human Gingival Fibroblast to Various Subgingival Restorations;A Comparative Study in Vitro (다양한 치은 연하 수복물에 대한 치은 섬유아 세포 부착 연구)

  • Lee, Eun-Suk;Song, In-Taeck;Lim, Jeong-Su;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.3
    • /
    • pp.621-636
    • /
    • 1999
  • When mucoperiosteal flaps are positioned and sutured to desirable position, the wound contains several interface between tissues which differ fundamentally in composition & biological reaction. Thus the C-T surface of the flap will, on one hand, oppose another vascularized surface, and on the other, the avascular dental material for example, when root resoptions, fractured root, endodontic perforation, deep root carious lesions were filled with amalgam, glass ionomer, resin etc. Recently, a number of case report described the successful treatment of a subgingival root lesion with restorative material & free gingival graft, open flap surgery, but more objective research was needed . Most of study on restorative materials were concerned for cytotoxicity not for actual healing event on that materials and its influencing factors such as biocompatibility, surface wettability, surface topography . The aim of this in vitro study was to evaluate the effect of amalgam, resin modified glass ionomer, composite resin per se, and their surface roughness on the growth of human gingival fibroblast. The cells were obtained and placed on culture flask and incubated for 3 days with the prepared test materials. Then count the attached cell number with hemocytometer,(n=12) and 2 samples were examined with SEM about attachment cell morphology . Another 4 samples were evaluated on their surface roughness with Talysurf and average surface roughness value(Ra) were obtained. Statistical difference in attached cell number, roughness value were analyzed using ANOVA. The number of attached cell was as follows, for root dentin specimen 16.7${\pm}$4.41, resin modified glass ionomer 14.0${\pm}$4.15, resin 8.13${\pm}$3.63, amalgam 0.72${\pm}$3.33(${\times}10^3$). Between root dentin and resin-modified glass ionomer, no significant difference was observed, but resin, amalgam showed a significant less cell numbers than for root dentin, resin modified glass ionomer cement. SEM examination expressed many cell surface attachment apparatus in root dentin and resin modified glass ionomer specimens. For resin specimen, cell attachment was observed but exposed less appratus. The average surface roughness value are following results. Dentin specimen 0.6972${\pm}$ 0.104, resin modified glass ionomer 0.0822${\pm}$0.009, resin 0.0875${\pm}$0.005, amalgam 4.2145${\pm}$0.985(${\mu}m$). Between root dentin, resin-modified glass ionomer, and resin, no significant difference was observed, but amalgam showed a significant more rough surface than other groups. When evlauated the interrelationship between cell attachment and surface roughness, therefore, there was weak reverse correlation.(pearson correlation : - 0.593) These results suggest that resin modified glass ionomer have the favorable healing potential when used for subgingival restoration. And for relationship between cell attachment and surface characteristics, further investigations were needed.

  • PDF

A Study on Indirect Attachment Method of Compensation Materials to Increase Signal Intensity in Magnetic Resonance Imaging (자기공명영상검사 시 신호강도를 높이기 위한 보상물질의 간접부착 방식에 관한 연구)

  • Son, Soon-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.7
    • /
    • pp.437-442
    • /
    • 2017
  • Previously, studies on compensation material to increase the signal intensity have been conducted which does not affect the reading of images. However, the compensation material has a concern on patient infection as it is attached directly on the skin. Therefore, in this study, we tested an indirect attachment of the compensation material as an alternative method of the direct attachment. The silicon compensation material was fabricated in the form of a cylindrical bar and attached to each element of the 8 channel head coil. Then the signal intensities of the water phantom pre and post application of the silicon were measured. T1 and T2-weighted images were acquired using an 8-channel head coil and a 3.0T superconducting MRI. Signal intensities were measured by using an image measuring program. Paired t-test was used to verify if there were significant differences. The signal intensity before application of the silicon was significantly increased by 3.39% and 2.62% in T1 and T2 weighted images, respectively. Although the indirect attachment method had a limitation to completely replace the existing method, it was considered to be useful in patients with infectious diseases such as diabetic complications since it had a meaningful improvement in signal intensity based on the filling factor increase.