• 제목/요약/키워드: Atrophic maxilla

검색결과 30건 처리시간 0.018초

심하게 흡수된 상악골에서 자가 장골 이식술과 동시에 시행한 임프란트 치료의 안정성에 대한 연구 (STABILITY OF SIMULTANEOUS IMPLANTATION WITH AUTOGENOUS ILIAC BONE GRAFT IN THE SEVERELY ATROPHIC MAXILLA)

  • 변준호;박봉욱;정희찬;김종렬
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권6호
    • /
    • pp.570-578
    • /
    • 2006
  • A severely atrophic maxilla may disturb the proper implant placement. The various bone graft techniques are required for simultaneous or delayed implantation in the cases of atrophic alveolar ridges. We present 11 consecutive patients treated with simultaneous implantation using the autogenous inlay and/or onlay bone grafts from iliac crest to the floor of the maxillary sinus and the alveolar crest. In the cases of atrophic maxilla, a total 69 implants were simultaneously placed with autogenous iliac bone graft. 40 fixtures were inserted in the sinus floor simultaneously with subantral block bone graft, the other 29 fixtures were placed in the anterior or premolar areas with block or particulate bone graft. The vertical alveolar bone height was measured with Dental CT at the preoperation and 6 months postoperation. Moreover, the implant stability quotients (ISQ) were measured by $Osstell^{TM}$ during second implant surgery at 6 months later of first implantation. All implants were obtained successful osseointegration with the grafted bone. The mean vertical increases were 3.9mm in the anterior ridges and 12.8mm in the posterior ridges. During the second implant surgery, mean ISQ were 62.95 in the anterior ridge and 61.32 in the posterior ridge. We concluded that the simultaneous implantation with autogenous iliac bone graft were stable and available methods for severely atrophic maxilla.

Evaluation of reliability of zirconia materials to be used in implant-retained restoration on the atrophic bone of the posterior maxilla: A finite element study

  • Degirmenci, Kubra;Kocak-Buyukdere, Ayse;Ekici, Bulent
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권2호
    • /
    • pp.112-119
    • /
    • 2019
  • PURPOSE. Zirconia materials have been used for implant-retained restorations, but the stress distribution of zirconia is not entirely clear. The aim of this study is to evaluate the stress distribution and risky areas caused by the different design of zirconia restorations on the atrophic bone of the posterior maxilla. MATERIALS AND METHODS. An edentulous D4-type bone model was prepared from radiography of an atrophic posterior maxilla. Monolithic zirconia and zirconia-fused porcelain implant-retained restorations were designed as splinted or non-splinted. 300-N occlusal forces were applied obliquely. Stress analyses were performed using a 3D FEA program. RESULTS. According to stress analysis, the bone between the 1) molar implant and the 2) premolar in the non-splinted monolithic zirconia restoration model was stated as the riskiest area. Similarly, the maximum von Mises stress value was detected on the bone of the non-splinted monolithic zirconia models. CONCLUSION. Splinting of implant-retained restorations can be more critical for monolithic zirconia than zirconia fused to porcelain for the longevity of the bone.

위축된 상악구치부에서 두 개의 짧은 임플란트 지지형 단일치관의 임상연구 (Two-short implant supported single molar restoration in atrophic posterior maxilla : a clinical study)

  • 송호용;허윤혁;박찬진;조리라
    • 대한치과의사협회지
    • /
    • 제53권9호
    • /
    • pp.628-643
    • /
    • 2015
  • Purpose: The aim of this retrospective study was to compare marginal bone loss and survival rates of double short implants(multiple implant) which had been installed and restored in severely atrophic maxillary molar site without a grafting procedure. Material and Method: The subjects were patients (90 patients, 180 implants) who had been installed double short implants in severely atrophic maxillary single molar site without bone augmentation procedure from 2006 to 2014 in dental clinic in Chuncheon city. Following data were collected from dental records and radiographic panoramic views: patient's age, gender, smoking status, implant site, timing of implant installation, residual ridge height. The correlation between those factors and survival rate and marginal bone loss were analyzed. Statistical analysis was performed using Chi-square test, Student's t- test and ANOVA. Result: Eleven implants in 6 patients failed and the cumulative survival rate was 93.9%. No significant differences were found in relation to the following factors: patient's age, gender, implant site, timing of implant installation (P> .05). There were significant differences in smoking status and residual ridge height(P< .05). The average follow-up time was $45{\pm}14.7months$. The mean marginal bone loss of survived 169 implants was $0.08{\pm}0.59mm$. Conclusion: Despite the short term outcomes, the survival rate of double short implants was comparable to normal length implants. This study demonstrated that placement of double short implants without the use of bone grafting procedure for severely atrophic posterior maxilla is a simple and predictable treatment procedure.

상악동 거상술을 이용하여 구치부에 식립된 $Br{\aa}nemark$ Ti-Unite와 ITI SLA 임플란트의 임상적 평가 (Clinical evaluation of $Br{\aa}nemark$ Ti-Unite implant and ITI SLA implant in the post maxillary area with sinus elevation technique.)

  • 홍성배;채경준;정의원;김창성;심준성;최성호;조규성;김종관
    • Journal of Periodontal and Implant Science
    • /
    • 제35권4호
    • /
    • pp.813-822
    • /
    • 2005
  • The predictable outcome of implant placement in the atrophic maxilla with sinus floor elevation procedure(osteotome sinus floor elevation technique and window opening technique) is well documented. Aim of this study was to evaluate the efficacy of $Br{\aa}nemark$ Ti-Unite implant system and ITI SLA implant system placed in the atrophic posterior maxilla with sinus floor elevation procedure. Eighty patients received placement of $Br{\aa}nemark$ Ti-Unite implants(195 implants) in their atrophic posterior Maxilla with sinus floor elevation procedure(153 osteotome sinus floor elevation technique and 42 window opening procedure). Fifty patients received placement of ITI SLA implants(83 implants) in their atrophic posterior Maxilla with sinus floor elevation procedure(77 osteotome sinus floor elevation technique and 6 window opening procedure). Chart review were taken from each patient. The total failed implants were seven and the total implant survival rate was 96.4% in $Br{\aa}nemark$ Ti-Unite system. The total failed implants were one and the total implant survival rate was 98.8% in ITI SLA system. The implant survival rate with osteotome technique was 96% and 97.6% with window opening in $Br{\aa}nemark$ Ti-Unite system. The implant survival rate with osteotome technique was 98.7% and 100% with window opening. The implant survival rate with osteotome technique was 96% and 97.6% with window opening in ITI SLA system. The results of this evaluation show that the placement of $Br{\aa}nemark$ Ti-Unite system as well as ITI SLA system is a reasonable treatment option for patients with the atrophic posterior maxillary area.

상악 구치부에서 자가골편 이식술의 예후와 골 변화량에 관한 후향적 연구 (A RETROSPECTIVE STUDY OF THE SURGICAL SUCCESS AND VERTICAL BONE RESORPTION RATE AFTER AUTOGENOUS BLOCK ONLAY GRAFT IN POSTERIOR MAXILLA)

  • 명미랑;김명래;김선종
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제35권5호
    • /
    • pp.340-345
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the surgical success of bone reconstruction of the severely atrophic maxilla using autogenous block bone onlay graft from the ramus and ilium prior to dental implantation. And we measured the amount of vertical height change Material and Methods: 26 partially edentulous patients(32 case) who needed block onlay bone graft before implant placement in posterior maxillary area from 2002 to 2009 were selected for this study. Patients consisted of 20 males & 6 females and the average of their age was 54.2. Patients who were treated with ramal bone were 19 case and patients who were treated with iliac bone were 11 case. Digital panoramic X-ray was taken at the day of surgery, 3 months and 6 months later after the surgery. Vertical height change & resorption rate of grafted bone were measured with the same X-rays and compared Results: Two out of 32 bone grafts had to be removed because of inflamation at the grafts area(97.3%). The mean of radiographic vertical height change(change rate) of post-op. 3 month was 0.54mm(8.5%)and 6 month was 0.99mm(15.9%). Compairing to intraoral donor site(ramus), iliac bone had more vertical height change(1.18mm) at 6 month after surgery. Conclusions: Within the limit of this study, autogenous block onlay grafts can be considered a promising treatment for severely atrophic maxilla.

Implant-supported overdenture manufactured using CAD/CAM techniques to achieve horizontal path insertion between the primary and secondary structure: A clinical case report

  • Agustin-Panadero, Ruben;Penarrocha-Oltra, David;Gomar-Vercher, Sonia;Ferreiroa, Alberto;Penarrocha-Diago, Miguel
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권3호
    • /
    • pp.264-270
    • /
    • 2015
  • This report describes the case of an edentulous patient with an atrophic maxilla and severe class III malocclusion. Prosthetic rehabilitation was performed using CAD/CAM techniques for manufacturing an implant-supported overdenture with horizontal insertion. A vestibulo-lingual insertion overdenture is a precision prosthesis with a fixation system affording a good fit between the primary and secondary structure. Both structures exhibit passive horizontal adjustment. This treatment option requires the same number of implants as implant-supported fixed dentures. The horizontal assembly system prevents the prosthesis from loosening or moving in response to axial and non-axial forces. The technique was used to rehabilitate a patient presenting an atrophic upper maxilla, with the insertion of 8 implants. No complications were reported at follow-up 3, 6 and 12 months after fitting of the prosthesis. This system offers solutions to the clinical and laboratory complications associated with hybrid prostheses, concealing emergence of the chimneys and improving implant-prosthesis hygiene.

A two-short-implant-supported molar restoration in atrophic posterior maxilla: A finite element analysis

  • Song, Ho-Yong;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권4호
    • /
    • pp.304-312
    • /
    • 2016
  • PURPOSE. The aim of this study was to investigate the stress distribution of 2-short implants (2SIs) installed in a severely atrophic maxillary molar site. MATERIALS AND METHODS. Three different diameters of internal connection implants were modeled: narrow platform (NP), regular platform (RP), and wide platform (WP). The maxillary first molars were restored with one implant or two short implants. Three 2SI models (NP-oblique, NP-vertical, and NP-horizontal) and four single implant models (RP and WP in a centered or cantilevered position) were used. Axial and oblique loadings were applied on the occlusal surface of the crown. The von Mises stress values were measured at the bone-implant, peri-implant bone, and implant/abutment complex. RESULTS. The highest stress distribution at the bone-implant interface and the peri-implant bone was noticed in the RP group, and the lowest stress distribution was observed in the 2SI groups. Cantilevered position showed unfavorable stress distribution with axial loading. 2SI types did not affect the stress distribution in oblique loading. The number and installation positions of the implant, rather than the bone level, influenced the stress distribution of 2SIs. The implant/abutment complex of WP presented the highest stress concentration while that of 2SIs showed the lowest stress concentration. CONCLUSION. 2SIs may be useful for achieving stable stress distribution on the surrounding bone and implant-abutment complex in the atrophic posterior maxilla.

Short dental implants in the posterior maxilla: a review of the literature

  • Esfahrood, Zeinab Rezaei;Ahmadi, Loghman;Karami, Elahe;Asghari, Shima
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제43권2호
    • /
    • pp.70-76
    • /
    • 2017
  • The purpose of this study was to perform a literature review of short implants in the posterior maxilla and to assess the influence of different factors on implant success rate. A comprehensive search was conducted to retrieve articles published from 2004 to 2015 using short dental implants with lengths less than 10 mm in the posterior maxilla with at least one year of follow-up. Twenty-four of 253 papers were selected, reviewed, and produced the following results. (1) The initial survival rate of short implants in the posterior maxilla was not related to implant width, surface, or design; however, the cumulative success rate of rough-surface short implants was higher than that of machined-surface implants especially in performance of edentulous dental implants of length <7 mm. (2) While bone augmentation can be used for rehabilitation of the atrophic posterior maxilla, short dental implants may be an alternative approach with fewer biological complications. (3) The increased crown-to-implant (C/I) ratio and occlusal table (OT) values in short dental implants with favorable occlusal loading do not seem to cause peri-implant bone loss. Higher C/I ratio does not produce any negative influence on implant success. (4) Some approaches that decrease the stress in posterior short implants use an implant designed to increase bone-implant contact surface area, providing the patient with a mutually protected or canine guidance occlusion and splinting implants together with no cantilever load. The survival rate of short implants in the posterior edentulous maxilla is high, and applying short implants under strict clinical protocols seems to be a safe and predictable technique.