A Study on the Fire Spread between Office Room and Atrium in the Atrium Building (아트륨 빌딩에서의 사무실과 아트륨간의 화재확산에 관한 연구)

  • Lee, Su-Kyung;Kim, Jong-Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.2
    • /
    • pp.78-83
    • /
    • 2000
  • Generally, There is to install fire resist shutter or to compart between the office room and the atrium in the atrium buildings in Korea. But, Glass wall that is installed sprinkler which purpose to protect it from fire, is already installed between the office room and the atrium in the advanced nations. We study this problem as follow; We made the fire scenario, and analyze each scenario using FASTLite is fire modeling software and BREAK1 is to predict the window breakage time in the compartment fire. In this study, we can decide that fire compartmentalization between atrium and office rooms doesn't require in Atrium building if the material and fire protection system were reliable. Consequently, Korean Fire Protection Regulations have to consider in direction of increasing freedom of building.

  • PDF

Evaluation of the daylight performance of four-sided atria with various well configurations for interior vegitation growth (실내 조경 식물의 생육을 고려한 4면형 아트리움의 형태변수별 자연채광 성능평가)

  • Song, Il-Hak;Kim, Ji-Hyun;Song, Kyoo-Dong
    • KIEAE Journal
    • /
    • v.11 no.5
    • /
    • pp.137-143
    • /
    • 2011
  • An atrium space, unlike ordinary office rooms, accommodates variety of activities such as moving and resting of people and usually houses variety of vegitation to improve amenity and indoor environment. Many atrium buildings in Korea have been designed by considering the environmental criteria for human beings, not for the vegitation in the atrium space. Especially the daylighting designs are mostly focused on the required illuminances for various visual tasks of the occupants and glare controls. As a result, some atrium spaces do not provide sufficient light to the interior plants. Consequently, these atrium spaces require a high level of electric lighting to compensate the deficit of natural light for the photosynthesis of the vegitation. The purpose of this study was to suggest design guidelines for 4-sided atrium spaces having different well indices (WI), plan aspect ratio (PAR), and cardinal orientation. The findings from this study might be referenced by building designers when designing or selecting canopy systems by considering the daylight performances of the uncovered atrium spaces. In the study, the daylight performance was evaluated in terms of daylight autonomy (DA).

A Comparative Analysis of the Energy Load due to Window Area Ratio of Domestic Public Buildings

  • An, Kwang-Ho;Hyun, Eun-Mi;Kim, Yong-Sik
    • KIEAE Journal
    • /
    • v.15 no.1
    • /
    • pp.21-27
    • /
    • 2015
  • In the case of public buildings, fast communication and transparency in the administration and the public, as well as ensuring visibility and lighting performance using a glass curtain wall is symbolically expressed through the transparent glass skin. This study is a simulation in order to derive the basic data for the establishment of the improvement of the heating and cooling load analysis according to the window area ratio changes with respect to the high effectiveness of the government's large public building energy consumption analysis and green building certification system of guidelines was analyzed by a change in the energy load. Glass curtain wall is light and visibility, the symbolic meaning of communication, etc., but is widely used in a variety of characteristics, in terms of energy consumption being disadvantaged sheath plan should have been. Design, including the Atrium, is much less energy than energy consumption by the window area ratio. Thus, while compliance with design guide lines, the atrium and I like the burden of a large space ratio and energy load consists of only glass suggest that require more research on that given in the guidelines.

of Renovation for Green Building of Public BuildingA Study on Adequacy (공공 건축물의 그린빌딩화를 위한 리노베이션수법의 타당성 연구)

  • Hyun, Gun-Chul;Kim, Tae-Il;Yang, Gun
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.1-10
    • /
    • 2010
  • The aims of this study is to analyze that the double-skinned outer surface of building will be the effective measure to improve the use of space and save energy through the evaluation of the buildings renovation. In other words, it is significantly effective to increase the insulation of the outer surface where the most heat loss occurs; it is also energy-saving to convert the space created by pilotis in the southern and northern parts of the buildings into an double-skinned atrium. Research methods of this study are consisted with two steps, situation analysis and simulation analysis. IRISYS 1000 Series Imager was used for research of situation analysis and Visual DOE 4.0 was used for simulation analysis with the 1st Buildings of Jeju Special self-Governing Province. As results of simulation, it was proved that Double skin Method is more effective for green building than basic model. it was predicted to save 8.6% of energy by Double skin Method. Especially, in case of using of ventilation within double-skinned atrium, it was predicted that saving of energy was most effective than other method.

An Application Study on a Strategy to Promote Natural Ventilation at an Atrium Building (아트리움을 이용한 자연환기 활성화 방안에 관한 사례 연구)

  • Shin, Seon-Joon;Lee, Seung-Yeon;Jo, Jin-Kyun;Han, Soo-Gon;Hong, Min-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.540-545
    • /
    • 2008
  • An atrium has great potential in natural ventilation aided by buoyance effect. Architectural design of an atrium is very critical to maximize the effect. However, it is not easy of an atrium to have optimum shape for natural ventilation, from the aesthetic and economic point of view. Admitting this condition, we suggested a strategy to promote natural ventilation, which can be adopted only with small design change. At first, we installed BIPV on the top of an atrium to strengthen buoyancy effect, and combine forced ventilation by low pressure fan. To evaluate the performance of the measure, CFD simulation and Energy-Airflow analysis were achieved.

  • PDF

A Study on Planning Conditions to Improve Openness assessment in Atrium (아트리움 건축의 개방감을 상승시키는 계획조건에 관한 연구)

  • Lee, Ji-Young;Lim, Jae-Han;Jung, Jin-Ju
    • KIEAE Journal
    • /
    • v.8 no.2
    • /
    • pp.41-46
    • /
    • 2008
  • Owing to a space covered by glass, atrium is an attractive space with a possibility as an inner public space but a typical building type with a high-energy load. From the aspect of global environmental issues, to reduce energy load is an important assignment to solve. Contriving a planning guideline of an opening is considered as the most effective environment adjustment method, to offer a highly assessed amenity space and secure openness to outside, keep the energy load to a minimum, and apply the natural energy such as daylight to a maximum at the same time. Users' assessment of environment was performed by questionnaire survey, then the structure of users' assessment was analyzed and design condition was regulated by multiple regression analysis. The opening design guideline to offer a highly assessed space was proposed with concrete environment adjustment method.

A Numerical Study of Smoke Movement by Fire In Atrium Space (화재 발생시 연기 거동에 대한 수치해석적 연구 - 아트리움 공간을 중심으로 -)

  • 노재성;유홍선;정연태
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.1
    • /
    • pp.70-76
    • /
    • 1998
  • The smoke filling process for the atrium space containing a fire source is simulated using two types of deterministic fire models : Zone model and Field model. The zone model used is the CFAST(version 1.6) model developed at the Building and Fire Research Laboratories, NIST in the USA. The field model is a self-developed fire field model based on Computational Fluid Dynamics(CFD) theories. This article is focused on finding out the smoke movement and temperature distribution in atrium space which is cubic in shape. A computational procedure for predicting velocity and temperature distribution in fire-induced flow is based on the solution, in finite volume method and non-staggered grid system, of 3-dimensional equations for the conservation of mass, momentum, energy, species and so forth. The fire model i. e. Zone model and Field model predicted similar results for the clear height and the smoke layer temperature.

  • PDF

A Numerical Study of Smoke Movement In Atrium Space (아트리움 공간에 있어서 연기 유동에 관한 수치해석적 연구)

  • 노재성;유홍선;정연태;김충익;윤명오
    • Fire Science and Engineering
    • /
    • v.11 no.4
    • /
    • pp.3-14
    • /
    • 1997
  • The smoke filling process for the atrium space containing a fire source is simulated using two types of deterministic fire model : Zone model and Field model. The zone model used is the CFAST(version 1.6) model developed at the Building and Fire Research Laboratories, NIST in the USA. The field model is a self-developed frie field model based on Computational Fluid Dynamic (CFD) theories. This article is focused on finding out the smoke movement and temperature distribution in atrium space which is cubic in shape. For solving the liked set of velocity and pressure equation, the PISO algorithm, which strengthened the velocity-pressure coupling, was used. Since PISO algorithm is a time-marching procedure, computing time si very fast. A computational procedure for predicting velocity and temperature distribution in fire-induced flow is based on the solution, in finite volume method and non-staggered grid system, of 3-dimensional equations for the conservation of mass, momentum, energy, species and so forth. The fire model i.e Zone model and Field model predicted similar results for clear heights and the smoke layer temperature.

  • PDF