• Title/Summary/Keyword: Atomic emission spectrometry

Search Result 121, Processing Time 0.022 seconds

Composite of Indium and Polysorbate 20 as Inhibitor for Zinc Corrosion in Alkaline Solution

  • Li, Xiaoping;Liang, Man;Zhou, Hebing;Huang, Qiming;Lv, Dongsheng;Li, Weishan
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.5
    • /
    • pp.1566-1570
    • /
    • 2012
  • The combined use of indium and polysorbate 20 (Tween 20) was considered as a new inhibition technique for zinc corrosion. Zn and Zn-In alloy coatings were prepared by electrodeposition and their morphology and composition were characterized by scanning electron microscopy (SEM) and inductively coupled plasma atomic emission spectrometry (ICP-AES). The corrosion inhibition effect of indium and Tween 20 on zinc was investigated by polarization curves and electrochemical impedance spectroscopy (EIS). The corrosion inhibition efficiencies obtained from Tafel and EIS analyses are well in agreement. Zinc corrosion can be inhibited to some extent by the individual use of indium and Tween 20 and higher corrosion inhibition efficiency can be obtained by the combined use of indium and Tween 20.

Simultaneous Determination of Sulfur, Phosphorus, and Zine in Lubricating Oils by Microwave Digestion System and ICP-AES (마이크로파 분해장치와 유도결합 플라스마 원자방출분광법을 이용한 윤활유 시료 중 S, P 및 Zn의 동시 분석)

  • Cho, Sung-Ill;Lim, Heon-Sung;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.324-330
    • /
    • 2001
  • For the analysis of S, P and Zn in lubricating oil, microwave digestion method was studied by using inductively coupled plasma-atomic emission spectrometry(ICP-AES). Lubricating oil was completely decomposed with nitric acid or a mixture of nitric acid and hydrogen peroxide using and closed microwave digestion system. Digestions are completed within 50 min, a factor of at least 3~4 times faster than for the conventional digestion. A gradual heating program operated by the pulsed mode was found suitable for decomposing the lubricating oil matrix safely. The proposed method of digestion gave relative standard deviations(RSD) less than 3% for the elements determined.

  • PDF

The Determination of Radon Progeny Concentration in Controlled Radon Environment (라돈을 제어하는 환경에서 라돈 자핵종의 농도 결정)

  • Seo, Kyung-Won;Lee, Byung-Kee
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.1
    • /
    • pp.37-51
    • /
    • 1993
  • A standard radon chamber and a radon generator adjusted by ventilation system which had used in this research were assumed to calculate theoretically the concentration of radon progeny using Jacobi model theory. On the one hand, the filter sampled from the radon standard chamber and the radon generator was measured and analysed by the alpha spectrometry method. It is clear that measured result shows a good agreement with theoretical result. Therefore, it is observed that this research can made a great contribution to more accurate internal dose assessment by alpha emission of radon progeny in indoor radon environment, and fast individual measurement and determination of concentration for radon progeny.

  • PDF

형광 X선에 의한 대기 부유분진중의 미량 성분의 측정 (I): -거름종이 표준시료에 의한 부유분진중 금속성분의 형광 X선 분석-

  • 이용근;맹현재;이보경;황규자
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.2
    • /
    • pp.21-29
    • /
    • 1989
  • The metals present in atmospheric particulate come from various sources; natural or anthropogenic. Among various metals Fe, Zn, Pb, Cu, and Mn are of particular concern in as much as they are not only present in large quantity, but toxic to human body. A simple, fast, and non-destructive analytical method for these metals in atmospheric particulate was developed and the analytical details were described herein. The method involves the measurements of X-ray fluorescence of sample contained in filters and comparing it with those for standards. The standard filters were prepared by applicating premeasured standard solution to the filters and then drying. The accuracy of the method was tested by analyzing standard reference materials and by independently analyzing samples using a different, previously accuracy-proven method, inductively coupled plasma atomic emission spectrometry, and comparing the results obtained. Analytical sensitivities and detection limits of the present method were 62.9, 178.2, 82.9, 146.1, 37.2, 120.3 cps/$\mug/cm^2$ and 39.0 35.6, 137.5, 125.9, 182.6, 72.8 $ng/cm^2$ for Fe, Zn, Pb, Cu, Mn, and Ni respectively. The method was applied to Seoul atmospheric particulate and some results were reported.

  • PDF

Synthesis of Ag/TiO2 Core/Shell Nanoparticles with Antibacterial Properties

  • Lin, Yue;Qiqiang, Wang;Xiaoming, Zhang;Zhouping, Wang;Wenshui, Xia;Yuming, Dong
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.8
    • /
    • pp.2607-2610
    • /
    • 2011
  • Monodispersed Ag/$TiO_2$ core/shell nanoparticles were synthesized in solution via colloid-seeded deposition process using Ag nanoparticles as colloid seeds and $Ti(SO_4)_2$ as Ti-source respectively. Silver nitrate was reduced to Ag nanoparticles with $N_2H_4{\cdot}H_2O$ in the presence of CTAB as stabilizing agent. The titania sols hydrolyzed by the $Ti(SO_4)_2$ solution deposited on the surface of Ag nanoparticles to form the Ag/$TiO_2$ core/shell nanoparticles. Inductively coupled plasma atomic emission spectrometry (ICP-AES) showed low amount of Ag ion leaching from the Ag/$TiO_2$ core/shell nanoparticles. The Ag/$TiO_2$ core/shell nanoparticles indicated excellent antibacterial effects against Escherichia coli and maintained long-term antibacterial property.

Analytic study on lead and cadmium in copper contained carbon materials (구리를 함유한 탄소소재의 납 및 카드뮴 분석에 관한 연구)

  • Choi, Zel-Ho
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.6
    • /
    • pp.307-313
    • /
    • 2010
  • Quantitative analytical condition for lead and cadmium in copper contained carbon materials using solvent extraction followed by inductively coupled plasma-atomic emission spectrometry was studied. Copper contained carbon samples were dissolved by nitric acid-perchloric acid digestion. Lead and cadmium were determined after separation with KCN masked copper by an dithizone-chloroform solvent extraction. Recovery efficiency of analyte elements was satisfactory, and most of matrix elements causing interference could be effectively eliminated by the separation. Lead and cadmium were quantitatively determined without influence of sample matrix, by applying it procedure to artifact sample.

Catalytic oxidation kinetics of iron-containing carbon particles generated from diesel-sprayed hydrogen-air diffusion flame (디젤-분무 수소-공기 확산화염에서 생성된 철-함유 탄소입자의 촉매 산화반응 특성)

  • Kim, Yongho;Kim, Yong-Tae;Kim, Soo Hyung;Lee, Donggeun
    • Particle and aerosol research
    • /
    • v.4 no.2
    • /
    • pp.51-67
    • /
    • 2008
  • In this study, we devoted to kinetic measurement of the catalytic oxidation of iron-containing flame soot particles and better understanding the role of catalytic particles on carbon oxidation in particular at low temperature, targeting on autothermal regeneration of diesel particulate filter by diesel exhaust gas. Carbon-based Fe-containing particles generated by spraying ferrocene-doped diesel fuel in an oxy-hydrogen flame are tested and compared with a commercial carbon black powder for thermogravimetric analysis (TGA), secondary ion mass spectrometry (SIMS), Fourier-transform infrared spectroscopy (FTIR), Induced coupled plasma-Atomic emission spectroscopy (ICP-AES), and High-resolution transmission electron microscopy (HR-TEM). As a result, we found that a small amount of the ferrocene addition led to significant reductions in a on-set temperature and an activation energy of the carbon oxidation as well. An oxygenated surface complex forming at the particle surface could be thought as active species that would be readily consumed in particular at low temperature.

  • PDF

A Study on Water-soluble Components in the Dustfall Matter at Cheju and Ullung Island (제주도와 울릉도의 강하분진중 수용성 성분에 관한 연구)

  • Choi, Jae-Cheon;Kim, San;Lee, Min-Young;Lee, Sun-Ki
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.4
    • /
    • pp.331-337
    • /
    • 1995
  • This study was carried out to investigate the chemical composition of dustfall at Cheju(mean sea level; 71.7m, 33$^{\circ}$17'N, 126$^{\circ}$10'E) and Ullung island(mean sea level; 22.1m, 38$^{\circ}$29'N, 130$^{\circ}$54'E) from October 1993 to september 1994. The dustfall matter samples were collected by deposit gauges. The ionic components of each samples was analyzed by Ion Chromatograpy (Dionex 4000i), While heavy metals by Inductively Coupled Plasma Atomic Emission Spectrometry(ICP/AES; Shimadzu ICP-4). The results for seasonal variation of dustfall matter matter total amount, water-soluble ionic components and water-soluble ionic components total deposition amount to two sites were compared each other. The seasonal variations of dustfall amount at Ullung and Cheju island were found in order of Spring>Winter>Fall>Summer, and the maximum of dustfall amount were during the Yellow Sand period. Also, Total amount of water-soluble components except for $F^{[-10]}$ were high in Cheju more than Ullung island.more than Ullung island.

  • PDF

Effects of Heavy Metals Pollution in Soil and Plant in the Industrial Area, West ALGERIA

  • Tahar, Kebir;Keltoum, Bouhadjera
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.6
    • /
    • pp.1018-1023
    • /
    • 2011
  • Alzinc is a ursine situated in the Ghazaouet town western part of the republic of Algeria. The purpose of this study was to determine the degree of contamination which soil and plants are burdened with some heavy metals: Pb, Zn, Ni, Cu, Cd, Mn, Cr, Fe and As, then the accumulation of heavy metals in the soil and plant adjacent of area the alzinc ursine was detected and the interdependence of pollution among all three regions of the environment determined. This paper analyzes the heavy metal contents within a 2-years period in the soil and plants at the beginning of the vegetation period. The presence of Pb, Zn, Ni, Cu, Cd, Mn, Cr, Fe and As, in the samples were analyzed using Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES). Measurements of heavy metal contents were performed at three locations in soil and vegetative parts of three-plant types (plant alimentary) period during summer. The plant samples from the immediate environment of the dumpsite were highly contaminated with Zn, Cd and Mn. Three plants species: grape, artichoke and pepper, particularly, grape met some of the conditions to be classified as accumulators for Zn, Cu, Cd and Fe, consequently, she revealed a health risk for human and livestock due to the spread of the metal pollution from waste dumpsites to agricultural areas.

Distribution and Characterization of Heavy Metals in Human Kidney Cortex and Kidney Medulla (인체 신장피질과 신장수질에서 중금속류의 분포 및 특성)

  • 유영찬;이상기;양자열;김기욱;이수연;정규혁
    • YAKHAK HOEJI
    • /
    • v.45 no.5
    • /
    • pp.460-467
    • /
    • 2001
  • Heavy metals, such as Al, As, Cd, Cr Cu, Fe, Hg, Mn, Mo, Ni, Pb, Se, Si, Sn, V and Zn, were analysed on kidney cortex and medulla of Korean obtained from 154 forensic medical autopsy cadavers. Heavy metals were analysed by inductively coupled plasma atomic emission spectrometry In kidney cortex, the concentrations of Al, Cd, Cu, Mn, Mo, Pb, Se, Si and Zn were significantly higher than in the kidney medulla (Cd, Cu, Mn, Mo, Zn : p<0.01, AA, Pb, Se, Si : p<0.05). No significant local differences were found between kidney cortex and kidney medulla in the concentrations of As, Cr Fe, Hg, Ni, Sn and V. In kidney cortex and kidney medulla, Cd concentrations correlated positively with age, but Mn concentrations correlated negatively with age. A significantly positive correlation between Cd and Zn, Cd and Cu, Zn and Cu, Al and Si, Se and As was found in kidney cortex and kidney medulla. A significantly positive correlation between Hg and Se was only observed in kidney cortex. These results indicate that the distribution of hazardous heavy metals is similar to that of essential elements in the tissues.

  • PDF