• Title/Summary/Keyword: Atomic emission spectrometry

Search Result 121, Processing Time 0.027 seconds

Development of Schiff Base Column and Glow Discharge Detector for HPLC : Preliminary Study I (HPLC용 Schiff Base 컬럼과 Glow Discharge 검출기의 개발에 관한 기초연구 I)

  • Kang, Mi-Ra;Kim, Eun-Soo;Shin, Jung-Sook;Park, Hyun-Kook;Yang, Jung-Sung;Lee, Sang C.
    • Analytical Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.265-272
    • /
    • 1995
  • Schiff base ligand columns and glow discharge detector have been developed for the trace analysis of metal ions desolved in water. Various types of hydrazide Schiff base ligands have been used and, additionally, they were examined as a filling material of a HPLC column. The hydrazide Schiff base ligands used were N, N'-oxalybis(salicylaldehydrazone) (OBSH), N, N'-malonylbis(salicylaldehydrazone) (MBSH), and N, N'-succinylbis(salicylaldehydrazone) (SBSH). A mixture of Schiff base ligand and poly(styrene divinylbenzene) was examined and it showed a smooth flow of solution. The OBSH-polymer column demonstrated different effluent factors for different metal ions. Metal ions in eluates were detected by Hollow Cathode Glow Discharge-Atomic Emission Spectrometry(HCGD-AES). HCGD-AES showed good sensitivity and selectivity. This is only the preliminary results of new OBSH-polymer column and glow discharge detector.

  • PDF

Direct Determination of Tellurium in Simulated Nuclear Spent Fuels by Hydride Generation-Inductively Coupled Plasma Atomic Emission Spectrometry (수소화물 생성-유도결합플라스마 원자방출분광법을 이용한 모의사용후 핵연료 중의 텔루르 분석)

  • Choi, Kwang Soon;Lee, Chang Heon;Han, Sun Ho;Joe, Kih Soo;Kim, Won Ho
    • Analytical Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.781-788
    • /
    • 2000
  • Tellurium in simulated nuclear spent fuels (SIMFUEL) has been determined by hydride generation-inductively coupled plasma atomic emission spectrometry (HG-ICP-AES). Parameters such as concentrations of HCl and $NaBH_4$, flow rate of HCl and $NaBH_4$ were optimized and then the effects of U, Mo, Pd, Rh and Ru on the Te intensity were investigated. A thiourea as a masking agent was used to eliminate or minimize such interferences specially caused by palladium. Tellurium was measured by HG-ICP-AES and ICP-MS after separation of tellurium from SIMFUEL with cation exchange chromatography. The relative deviation between direct measurement and separation method was less than 6% based on the data by ICP-MS.

  • PDF

Study on the Analytical Performance of Double Membrane Desolvator(DMD) with Perfluoroalkoxy(PFA) and Microconcentric Nebulizer(MCN) in Inductively Coupled Plasma Atomic Emission Spectrometry (유도결합 플라스마 원자방출 분광법에서 perfluoroalkoxy(PFA) nebulizer와 microconcentric nebulizer(MCN)을 이용한 double membrane desolvator(DMD)의 분석능력연구)

  • Sul, Choon-Kuen;Lim, H.B.
    • Analytical Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.21-27
    • /
    • 2001
  • In this work, analytical performance of a laboratory built double membrane desolvator (DMD) was studies using perfluoroalkoxy (PFA) nebulizer and microconcentirc nebulizer (MCN) in inductively coupled plasma atomic emission spectrometry. Compared with MCN, PFA nebulizer coupled to DMD showed similar analytical sensitivity for aqueous solution and better sensitivity for isopropyl alcohol. Since PFA resisted various acids, HCI, $H_2SO_4$ and HF solution were analyzed with less than 2% RSD. Rinse-out time for the signal reduction to 1% was obtained to be 35 s for PFA but about 45 s for MCN.

  • PDF

Concentration of Fe, Cu, Zn in 24-hour Food Duplicate Samples: Quantitative Analysis by Inductively Coupled Plasma - Atomic Emission Spectrometry (24시간 복제 음식물 중의 Fe, Cu, Zn 함량: 유도결합플라즈마-원자발광분광법에 의한 정량분석)

  • Paik, Jong-Min;Moon, Chan-Seok
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.5
    • /
    • pp.397-402
    • /
    • 2007
  • The present study was initiated to examine the measures of dietary intake of Fe, Cu and Zn. The food duplicate samples were collected in Busan and its neighboring area, from the 69 middle-aged women (healthy non-smoking, mostly house wives), who provided informed consent. The samples were wet ashed by being heated in the presence of mineral acids, and Fe, Cu, Zn in the wet-ashed samples were analyzed by inductively coupled plasma - atomic emission spectrometry(ICP-AES). Dietary intake of Fe, Cu and Zn were 10.4 mg/day in Fe, 1.2 mg/day in Cu, 7.4 mg/day as arithmetic mean. The values for dietary Fe and Zn were lower, and the values for dietary Cu were higher than the recommended daily intake from Korean Nutrition Society. Further studies of Korean foods are needed to clarify the representative values for daily dietary Fe, Cu and Zn intake in the Korean population.

Determination of Trace Elements of Ge and P in a Gold Bonding Wire by Inductively Coupled Plasma Atomic Emission Spectrometry

  • Choi, Sung-Min;Lee, Gae-Ho;Han, Jae-Kil
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.2
    • /
    • pp.393-397
    • /
    • 2008
  • Inductively coupled plasma atomic emission spectrometry (ICP-AES) was used to determine the presence of germanium and phosphorus in a pure gold bonding wire. The samples were dissolved with hydrobromic acid and nitric acid at room temperature. The quantitation limits were 0.012 mg L-1 at 265.118 nm for Ge and 0.009 mg L-1 at 177.495 nm for P. Using the mixed acid digestion formula of DIW+HBr+HNO3, the recoveries were in the range of 98-100% and the relative standard deviation was within 1.1-2.3%. On the other hand, the amount of Ge decreased by about 16.2% using DIW+HCl+HNO3, due to the formation of a volatile compound. The Ge contents determined using the external method and the standard addition method were 9.45 mg kg-1 and 9.24 mg kg-1, respectively, and the P contents, using the same methods, were 22.49 mg kg-1 and 23.09 mg kg-1, respectively. Both methods were successfully used to determine the trace amounts of P and Ge in the pure gold bonding wire samples.

Determination of osmium using sulfurous acid as reductant by ICP-AES (Sulfurous acid 환원제를 이용한 ICP-AES에 의한 Osmium의 정량 분석)

  • Park, Han-Seok;Kim, Kang-Jin
    • Analytical Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.251-254
    • /
    • 2007
  • In this study, a convenient, fast and accurate inductively coupled plasma atomic emission spectrometry (ICP-AES) method has been optimized for the determination of osmium in aqueous solutions. The method makes use of the reaction of sulfurous acid with osmium to quantitative conversion of volatile Os(VIII) to non-volatile Os(IV) in the pH range 2-10. The response was found to be stabilized immediately after sulfurous acid reacted with osmium. The precision was calculated to be 0.5-4.5 % (RSD) under various ICP-AES conditions. The detection limit was 2.5-57.7 ng/g based on $3{\sigma}$ of the blank response (n=3) using a concentric flow nebulization.

Polymer (Polydimethylsiloxane (pdms)) Microchip Plasma with Electrothermal Vaporization for the Determination of Metal Ions in Aqueous Solution

  • Ryu, Won-Kyung;Kim, Dong-Hoon;Lim, H.B.;Houk, R.S.
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.4
    • /
    • pp.553-556
    • /
    • 2007
  • We previously reported a 27.12 MHz inductively coupled plasma source at atmospheric pressure for atomic emission spectrometry based on polymer microchip plasma technology. For the PDMS polymer microchip plasma, molecular emission was observed, but no metallic detection was done. In this experiment, a lab-made electrothermal vaporizer (ETV) with tantalum coil was connected to the microchip plasma for aqueous sample introduction to detect metal ions. The electrode geometry of this microchip plasma was redesigned for better stability and easy monitoring of emission. The plasma was operated at an rf power of 30-70 W using argon gas at 300 mL/min. Gas kinetic temperatures between 800-3200 K were obtained by measuring OH emission band. Limits of detection of about 20 ng/mL, 96.1 ng/mL, and 1.01 μ g/mL were obtained for alkali metals, Zn, and Pb, respectively, when 10 μ L samples in 0.1% nitric acid were injected into the ETV.

Development of Controlling and Analyzing Software for Portable Atomic Emission Spectrometry (휴대용 원자 방출 분광계를 위한 제어 및 분석용 소프트웨어 개발)

  • Lee, Sang Chun;Lee, Chang-Soo;Jung, Min-Soo;Ryu, Dong-Hang
    • Analytical Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.1-7
    • /
    • 1998
  • This study focuses on developing a controlling and analyzing software for the portable atomic emission spectrometer equipped with an electrothermal vaporizer(ETV) that can perform the in-situ trace analysis of heavy metal ions dissolved in water. The software works well for a notebook PC and it is exclusively developed for the real time analysis with a line filter and a photomultiplier light detector. The program is designed to operate under Windows 95 environment and either Korean or English can be used as a main language. The Delphi 2.0 language software is mainly used for programing. The program is designed to make a calibration curve and the system users can get the analytical data in a short time. And a final report can be generated without having difficulties. This software can be easily modified for other analytical atomic spectrometers.

  • PDF

A Direct Reading Atomic Emission Spectrometer for Chemical Analysis in the Iron and Steels (직독식 원자방출분광기를 이용한 철강중의 성분원소 분석)

  • Kim, Yeong Man;Jeong, Chan Lee;Kim, Seon Tae;Choe, Beom Seok
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.11
    • /
    • pp.800-807
    • /
    • 1994
  • A method to determine the iron and steels employing a Direct Reading Atomic Emission Spectrometer was investigated. Matrix effect was removed by two correction methods which utilize linear and curvilinear functions. Although two methods gave different sets of matrix correction coefficients, the analytical results by the two methods gave the same results. The analytical results obtained by the present work were well agreed with those obtained by inductively coupled plasma spectrometry.

  • PDF