• 제목/요약/키워드: Atomic Absorption

검색결과 881건 처리시간 0.025초

원자흡광분광분석법에 의한 혈청 Zn의 측정 (Direct Determination of Serum Zinc by Atomic Absorption Spectroscopy)

  • 채범석;석영건;박동수
    • Journal of Nutrition and Health
    • /
    • 제4권3호
    • /
    • pp.1-4
    • /
    • 1971
  • Zinc is an essential trace element. Previos methods for the determination of zinc in serum have been difficult and reported findings must be treated with caution. The normal range of zinc in serum varies significantly according to different methods and author. The scope of this work was to establish the normal range of zinc in serum values in healthy Korean persons. Methods are described for the determination of zinc in serum diluted ten-fold with deionised water using Hitachi Model 207, atomic absorption spectrophotometer. The values of zinc in serum of 23 healthy Korean persons by atomic absorption spectroscopy ranged from 87.6 to $131.2\;{\mu}g/100\;ml$ with the mean value $109.1\;{\mu}g/100\;ml$ and standard deviation 10.86. In this method, satifactory result was obtained with regard to the coefficient variation and recoveries of added zinc in the measurenents.

  • PDF

새로운 킬레이트 시약을 이용한 금의 원자흡수광도법 정량 (Determination of Gold by Flame Atomic Absorption Spectrophotometry using a New Chelating Agent)

  • 이진식;카츠야 우에스기;나가히로 토루;최원형;김경태;최성용
    • 분석과학
    • /
    • 제8권3호
    • /
    • pp.391-396
    • /
    • 1995
  • A rapid preconcentration method based on solvent extraction is described for the determination of gold by flame atomic absorption spectrophotometry. Trace amounts of gold was extracted as a new chelating agent, 3-thiophenaldehyde-4-phenyl-3-thiosemicarbazone from pH 4.0 in diisobutyl ketone. The method is simple, fast, free from the effect of many interfering ions and has a high sensitivity and a good precision. Gold is quantitatively separated and concentrated from the elements in standard sample, and the value of the recovery was 91.7 and 108.3% by the proposed method.

  • PDF

Determination of Lead in Different Samples by Atomic Absorption Spectrometry after Preconcentration with Dithizone Immobilized on Surfactant-Coated Alumina

  • Dadfarnia, S.;Haji Shabani, A.M.;Dehgan Shirie, H.
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권4호
    • /
    • pp.545-549
    • /
    • 2002
  • A simple and rapid technique for the separation and preconcentration of lead in water and biological samples has been devised. Preconcentrationis based on the depositionof analyte onto a column packed with dithizone immobilized on sodium dodecyl sulfate coated alumina at pH $\geq$ 3. The trapped lead is eluted with 5 mL of 4 M nitric acid and determined by flame atomic absorption spectroscopy. A sample of 1 L, results in a preconcentration factor of 200 and the precision at 20${\mu}g$ $L^{-1}$ is 1.3%(n=8). The procedure is applied to tap water, well water, river water, vegetable extract and milk samples, and accuracy is assessed through recovery experiments and by independent analysis by furnace atomic absorption.

환원기화 원자 흡광광도법에 의한 대기분진중의 총 셀렌의 정량 (Hydride Generation-Atomic Absorption Spectrophotometric Determination of Total Selenium in Atmospheric Particulate)

  • 이용근;최건형;이동수;황규자
    • 한국대기환경학회지
    • /
    • 제6권2호
    • /
    • pp.147-154
    • /
    • 1990
  • A sensitive method for the determination of total selenium in aerosol particles is described. The method involves dissolution of aerosol particles by $HNO_3-HClO_4$ mixed acids, pre-reduction of Se (VI) to Se (IV) by boiling hydrochloric acid, and hydride generation followed by atomic absorption detection. Dissolved Se (IV) in 4M hydrochloric acid is reacted with $NaBH_4$ to form $H_2Se$, which is subsequently collected in an U-tube cooled in liquid nitrogen. Upon the completion of $H_2Se$ generation, the collected $H_2Se$ is rapidly vaporized into a quartz cuvette burner by removing the U-tube from liquid nitrogen, atomized, and then detected by an atomic absorption spectrophotometer. The absolute sensitivity of the method is 0.49 ng/0.0044 Abs. The accuracy of the method evaluated by analyzing standard reference materials for urban aerosol is better than 10%. Analytical results for urban and rural aerosol particles are reported.

  • PDF

Prenconcentration and Determination of Mercury (II) and Methylmercury in Waters by Immobilized 1,5-Diphenylcarbazone and Cold Vapor Atomic Absorption Spectrometry

  • Dadfarnia, Shayessteh;Salmanzadeh, Ali Mohammed;Haji Shabani, Ali Mohammed
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권12호
    • /
    • pp.1719-1723
    • /
    • 2002
  • 1,5-diphenylcarbazone was immobilized on sodium dodecyl sulfate coated alumina. The alumina particle was effectively used for collection of mercury(II) and methylmercury cations at sub-ppb level. The adsorbed mercury was eluted with l mol $L^{-1}$ of hydrobromic acid solution. The mercury(II) was then directly measured by cold vapor atomic absorption spectrometry utilizing tin (II) chloride where as the total mercury was determined after the oxidation of methylmercury into the inorganic mercury. The methylmercury concentration was calculated by the difference between the value of total mercury and mercury (II). Mercury (II) and methylmercury cations were completely recovered from water with a preconcentration factor of 100 (for 1 L solution.) Relative standard deviation at Hg L ${\mu}gL^{-1}$ level 1.7%(n=8) and the limit of detection was 0.11 ${\mu}gL^{-1}$. The procedure was applied to spring water, well water and seawater and accuracy was assessed through recovery experiments.

흑연로 원자흡수분광광도법에 의한 뇨시료 중 흔적량 원소의 정량 (Determination of Trace Elements in Urine Samples by Graphite Furnace Atomic Absorption Spectrophotometry)

  • 최종문;최희선;박창준;김영상
    • 분석과학
    • /
    • 제7권4호
    • /
    • pp.555-561
    • /
    • 1994
  • A method was described for the graphite furnace atomic absorption spectrophotometric determination of trace cadmium, copper, chromium and lead in urine samples. The elements were directly determined without any other treatments. The ash temperature was intensively optimized to improve the large background by the removal of organic materials and alkali and alkali earth metals in urine samples. Two kinds of standard solutions were used to plot calibration curves. From the recovery data, it could be confirmed that the analytical results with the synthetic urine matrix similar to real urine were more accurate than with a deionized water matrix.

  • PDF

Benefits of the S/F Cask Impact Limiter Weldment Imperfection

  • Ku, Jeong-Hoe;Lee, Ju-Chan;Kim, Jong-Hun;Park, Seong-Won;Park, Hyun-Soo
    • Nuclear Engineering and Technology
    • /
    • 제32권2호
    • /
    • pp.191-203
    • /
    • 2000
  • This paper describes the beneficial effect of weldment imperfection of the cask impact limiter, by applying intermittent-weld, for impact energy absorbing behavior. From the point of view of energy absorbing efficiency of an energy absorber, it is desirable to reduce the crush load resistance and increase the deformation of the energy absorber within certain limit. This paper presents the test results of intermittent-weldment and the analysis results of cask impacts and the discussions of the improvement of impact mitigating effect by the imperfect-weldment. The rupture of imperfect weldment of an impact limiter improves the energy-absorbing efficiency by reducing the crush load amplitude without loss of total energy absorption. The beneficial effect of weldment imperfection should be considered to the cask impact limiter design.

  • PDF

다중-V 타입 원자계에서의 전자기 유도 흡수 (Electromagnetically-Induced-Absorption in Multiple-V type Atomic Systems)

  • 박종대;조창호;이철세
    • 자연과학논문집
    • /
    • 제12권1호
    • /
    • pp.41-48
    • /
    • 2002
  • 원자와 빛과의 상호작용으로 인해 원자에 결맞음이 유도될 수 있는데, 이 결맞음은 새로운 현상을 보여 줄 수 있다. 그 중 전자기 유도 흡수는 결합광의 영향으로 조사광의 흡수가 증가하는 현상인데, 다중-V 타입 원자계에서 관측될 수 있다. 본 논문에서는 주파수가 다른 조사광이 결합광과 같은 천이선에 인가되는 경우 전자기 유도 흡수현상을 이론적으로 연구하기 위한 방법을 제시하였다. 조사광과 원자의 상호작용을 시간의존 해밀토니안으로 표시하였으며, 밀도 행렬요소의 변화는 밀도행렬방정식을 풀어서 조사하였고, 행렬 요소 변화의 진폭으로부터 전자기 유도 흡수를 계산하였다.

  • PDF

사고시 논으로 유출된 핵종 이동 모델 및 실험결과와의 비교 (Model for Transport of Accidently Released Radionuclides onto Rice-Fields and its Comparison with Experimental Data)

  • 금동권;이한수;최희주;강희석;임광묵;최용호;이창우
    • Journal of Radiation Protection and Research
    • /
    • 제29권2호
    • /
    • pp.117-127
    • /
    • 2004
  • 핵종 누출 사고시 논으로의 핵종 이동 평가를 위한 동적격실모델을 개발하였다. 개발된 모델에는 벼 재배에 필수적인 관개수를 고려하여 표면수 격실과 줄기기부흡수 개념을 도입하였고, 이식 전 쟁기질과 관개담수에 의한 토양 혼합을 고려하였으며, 벼 성장에 따른 뿌리흡수상수, 줄기기부흡수상수의 변화를 생체량의 함수로 모델링하였다. 모델의 타당성 조사를 위해 고리, 영광 및 울진 원자력 발전소 주변 지역에서 채취한 논 토양으로 벼를 재배하면서 벼 생육단계별로 수행된 $^{137}Cs$ 모의 침적 실험 해석에 모델을 적용하였다. 모델은 대체적으로 한 승수 내에서 실험 결과와 잘 일치하였다.

삼중수소 저장을 위한 ZrCo 저장재에서의 수소 흡장에 대한 수치해석적 연구 (I) (A Numerical Investigation of Hydrogen Absorption Reaction Based on ZrCo for Tritium Storage (I))

  • 유하늘;윤세훈;장민호;강현구;주현철
    • 한국수소및신에너지학회논문집
    • /
    • 제23권5호
    • /
    • pp.448-454
    • /
    • 2012
  • In this paper, a three-dimensional hydrogen absorption model is applied to a thin double-layered annulus ZrCo hydride bed and validated against the temperature evolution data measured by Kang et al. The present model reasonably captures the bed temperature evolution behavior and the 99% hydrogen charging time. The equilibrium pressure expression for hydrogen absorption on ZrCo is derived as a function of temperature and the H/M atomic ratio based on the pressure-composition isotherm data given by Konishi et al. In addition, this present model provides multi-dimensional contours such as temperature and H/M atomic ratio in the thin doublelayered annulus metal hydride region. This numerical study provides fundamental understanding during hydrogen absorption process and indicates that efficient design of the metal hydride bed is critical to achieve rapid hydrogen charging performance. The present three-dimensional hydrogen absorption model is a useful tool for the optimization of bed design and operating conditions.