• Title/Summary/Keyword: Atmospheric Effect

Search Result 1,587, Processing Time 0.03 seconds

Real-time Haze Removal Method using Brightness Transformation based on Atmospheric Scatter Coefficient Rate and Local Histogram Equalization (대기 산란 계수 비율 기반의 밝기변환과 지역적 히스토그램 평활화를 이용한 실시간 안개 제거 방법)

  • Lee, Jae-Won;Hong, Sung-Hoon
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.1
    • /
    • pp.10-21
    • /
    • 2016
  • Images taken from outdoor are degraded quality by fog or haze, etc. In this paper, we propose a method that provides the visibility improved images through fog or haze removal. We proposed haze removal method that uses brightness transform based on atmospheric scatter coefficient rate with local histogram equalization. To calculate the transmission rate that indicate fog rate in original image, we use atmospheric scatter coefficient rate based on quadratic equations about haze model. And primary brightness transformed image can be obtained by using the obtained transmission rate. Also we use local histogram equalization with proposed brightness transform for effectively image visibility enhancement. Unlike existing methods, our method can process real-time with stable and effect image visibility enhancement. Proposed method use only the luminance images processed by good performance surveillance systems because it represents the real-time processing is required, black-box, digital camera and multimedia equipment is applicable. Also because it shows good performance only with the luminance images processed, Surveillance systems, black boxes, digital cameras, and multimedia devices etc, that require real-time processing can be applied.

Mechanical Properties of Vapor Grown Carbon Fiber/Epoxy Nanocomposites With Different Dispersion Methods

  • Khuyen, Nguyen Quang;Kim, Byung-Sun;Kim, Jin-Bong;Lee, Soo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.264-271
    • /
    • 2007
  • Effect of dispersion methods for Vapor Grown Carbon Fibers (VGCF) in epoxy caused the change in mechanical properties of VGCF/epoxy nanocomposites, such as tensile modulus and tensile strength. The influence of VGCF types - atmospheric plasma treated (APT) VGCF and raw VGCF - and their contents was discussed in detail. Treating VGCF with atmospheric plasma enhanced the surface energy, therefore improved the bonding strength with epoxy matrix. Two different methods used to disperse VGCF were ultrasonic and mechanical homogenizer methods. When using dispersion solutions, the VGCF demonstrated good dispersion in ethanol in both homogenizer and ultrasonic method. The uniform dispersion of VGCF was investigated by scanning electron microscopy (SEM) which showed well-dispersion of VGCF in epoxy matrix. The tensile modulus of raw VGCF/epoxy nanocomposites obtained by ultrasonic method was higher than that of one obtained by homogenizer method. APT VGCF/epoxy nanocomposites showed higher tensile strength than that of raw VGCF/epoxy nanocomposites.

Analysis of Data Rate on Optical Communication Links between Geo-Satellite and Earth Station (정지궤도 위성과 지구국간 광통신 링크의 전송속도 해석)

  • Han, Jong-Seok;Jung, Jin-Ho;Kim, Yung-Kwon
    • Journal of IKEEE
    • /
    • v.1 no.1 s.1
    • /
    • pp.120-137
    • /
    • 1997
  • Han's model, which is able to analyze optical communication between earth station and geo-satellite as a function of atmospheric conditions and elevation angles. is presented. In Han's model, atmospheric conditions are roughly classified into six basic types; clear sky, cloud, haze, fog, rain and snow. Data rate satisfying for the BER below $10^{-7}$ is analyzed by Han's model in case of up-link and down-link, respectively. Data rate is more limited by up-link than by down-link because the pointing loss caused by atmosphere on the up-link is greater than the spatial coherence degradation caused by atmosphere on the down-link.

  • PDF

A Numerical Study of a Effect of the Uniform Flow in Horizontal Convection (일반류가 수평대류에 미치는 영향에 관한 수치연구)

  • Lee, Hwa-Woon;Kim, Yoo-Keun;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.7 no.3
    • /
    • pp.349-360
    • /
    • 1998
  • Effects of uniform flow on a two-dimensional mesoscale horizontal convection were investigated by using the vorticity and thermodynamic equations. For thins purpose, We simulated properties of a thermal convection m a stably stratified Boussinesq flued caused by partial heating at the center of a lower boundary If we don't consider effects of the uniform flow, the convection takes the form of aidsymmetrlc with respect to the z-alds. But when uniform flow Is strong, velocity field and temperature field consist of a sin91e cell structure which spreads upstream side of the partial heating area. The flow pattern for strong uniform flows takes the form of positive temperatue near the ground and negative temperature perturbation soft over the partial heating area, and downward motion directly over the upwind portion of the partial heating area and upward motion on the downstream side. The downstream edge of the upstream cell Is shifted in the downstream direction with the Increase of uniform flow almost linearly.

  • PDF

An Analysis of Climatic Elements around the Pohang area (포항지역의 기후요소별 분석)

  • Jung, Woo-Sik;Kim, Hyun-Goo;Lee, Soon-Hwan;Lee, Hwa-Woon
    • Journal of the Korean earth science society
    • /
    • v.24 no.5
    • /
    • pp.449-455
    • /
    • 2003
  • Climatic elements were investigated in order to understand the atmospheric environment around the Pohang area and for use as basic information in prediction. In this analysis, we could find that the annual mean temperature, relative humidity, and precipitation are 14.39$^{\circ}C$, 63.3%, and 1.178mm, respectively. The prevailing wind direction was southwestern, and the mean wind speed is 2.7m/s. The amount of cloud was abundant during the summer because of the Jang-ma phenomenon and convective clouds induced by terrain effect. The annual mean duration of sunshine represented about 2,221 hours.

Laser-Induced Plasma Spectroscopy Measurement on Surface Roughness in Surface Treatment of Titanium Alloys (티타늄 합금의 표면 처리에 있어 표면 거칠기에 대한 레이저 유도 플라즈마 분광분석법 측정 적용 연구)

  • Kim, Ji-Hun;Kim, Joohan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.2
    • /
    • pp.9-17
    • /
    • 2020
  • In this study, the surface changes of titanium alloy using laser surface treatment and the surface analysis using laser-induced plasma spectroscopy were carried out. The laser surface treatment induced changes in surface roughness and the diffusion of atmospheric elements. Excessive melting or less melting caused roughness changes, but when moderate levels of energy were applied, a smoother surface could be obtained than the initial surface. In the process, the diffusion of atmospheric elements took place. To analyze the diffusion of atmospheric elements with respect to surface morphology, the surfaces were re-shaped with grinding. In this experimental conditions, the effect of plasma formation by surface roughness was identified. Compensated plasma signals for the material properties were obtained and analysed by removing the background plasma signal.

Understanding on Regional Characteristics of Particular Matter in Seoul - Distribution of Concentration in Borough Spatial Area and Relation with the Number of Registered Vehicles - (서울시 미세먼지 농도의 지역적 특성파악을 위한 연구 - 구별 분포 특성 및 차량등록대수와의 관계 -)

  • Park, Jong-Kil;Choi, Yun-Jeong;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.26 no.1
    • /
    • pp.55-65
    • /
    • 2017
  • Average concentration of PM in Seoul metropolitan area satisfied the Korean air quality standard in 2010. Furthermore, concentration of PM in all boroughs across Seoul met the air environment standard in 2012. $PM_{10}$ concentration was relatively higher in center of Seoul in comparison to the rest, while $PM_{2.5}$ concentration showed exactly the contrary result. We analyzed the effect that PM emissions from vehicles would have on PM concentrations across Seoul. The results showed that average annual PM concentration recently decreased in Seoul although the number of vehicles registered annually continued its upward trend. By contrast, average fine dust concentrations in Seoul showed a decline which suggested that correlation between annual average PM concentrations and number of registered vehicles remained low. However, year-on-year vehicle registration rate recently showed a declining tendency in the same way as the trend of changes in average PM concentrations. Particularly, the upward trend in annual average PM concentrations in 2002 and 2007 was consistent with the increase in vehicle registration rate, suggesting that vehicle registration rate was closely associated with changes in PM concentrations.

Development of a Plasma Waterjet Scrubber for the Reduction of PFCs (과불화탄소 제거를 위한 플라즈마 워터젯 스크러버 개발)

  • Lee, Chae-Hong;Chun, Young-Nam
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.6
    • /
    • pp.624-632
    • /
    • 2010
  • Perfluorocarbons (PFCs) are widely used in semiconductor industry. These gases need to be removed efficiently because of their strong absorption of infrared radiation and long atmospheric lifetimes which cause the global warming effect. To destruct $CF_4$, a waterjet gliding arc plasma was designed and manufactured. The highest $CF_4$ destruction showed at waterjet plasma case, compared to plasma discharge only or water scrubber only, respectively. In addition, it could be known that the $CF_4$ destruction should be associated with the electron and OH radicals. The operating conditions such as waterjet flow rate, initial $CF_4$ concentration, total gas flow rate, specific energy input were investigated experimentally using a plasma waterjet scrubber. Through the parametric studies, the highest $CF_4$ destruction of 94.5% was achieved at 0.2% $CF_4$, 2.1 kJ/L SEI, 20 L/min total gas flow rate and 18.5 mL/min waterjet flow rate.

A Monitoring System of Ensemble Forecast Sensitivity to Observation Based on the LETKF Framework Implemented to a Global NWP Model (앙상블 기반 관측 자료에 따른 예측 민감도 모니터링 시스템 구축 및 평가)

  • Lee, Youngsu;Shin, Seoleun;Kim, Junghan
    • Atmosphere
    • /
    • v.30 no.2
    • /
    • pp.103-113
    • /
    • 2020
  • In this study, we analyzed and developed the monitoring system in order to confirm the effect of observations on forecast sensitivity on ensemble-based data assimilation. For this purpose, we developed the Ensemble Forecast Sensitivity to observation (EFSO) monitoring system based on Local Ensemble Transform Kalman Filter (LETKF) system coupled with Korean Integrated Model (KIM). We calculated 24 h error variance of each of observations and then classified as beneficial or detrimental effects. In details, the relative rankings were according to their magnitude and analyzed the forecast sensitivity by region for north, south hemisphere and tropics. We performed cycle experiment in order to confirm the EFSO result whether reliable or not. According to the evaluation of the EFSO monitoring, GPSRO was classified as detrimental observation during the specified period and reanalyzed by data-denial experiment. Data-denial experiment means that we detect detrimental observation using the EFSO and then repeat the analysis and forecast without using the detrimental observations. The accuracy of forecast in the denial of detrimental GPSRO observation is better than that in the default experiment using all of the GPSRO observation. It means that forecast skill score can be improved by not assimilating observation classified as detrimental one by the EFSO monitoring system.

Sterilization of Bacteria, Yeast, and Bacterial Endospores by Atmospheric-Pressure Cold Plasma using Helium and Oxygen

  • Lee Kye-Nam;Paek Kwang-Hyun;Ju Won-Tae;Lee Yeon-Hee
    • Journal of Microbiology
    • /
    • v.44 no.3
    • /
    • pp.269-275
    • /
    • 2006
  • Atmospheric-pressure cold plasma (APCP) using helium/oxygen was developed and tested as a suitable sterilization method in a clinical environment. The sterilizing effect of this method is not due to UV light, which is known to be the major sterilization factor of APCP, but instead results from the action of reactive oxygen radicals. Escherichia coli, Staphylococcus aureus, and Saccharomyces cerevisiae deposited on a nitrocellulose filter membrane or Bacillus subtilis spores deposited on polypropylene plates were exposed to helium/oxygen plasma generated with AC input power at 10 kHz, 6 kV. After Plasma treatment, nitrocellulose filter membranes were overlaid on fresh solid media and CFUs were counted after incubation overnight. D-values were 18 sec for E. coli, 19 sec for S. aureus, 1 min 55 sec for S. cerevisiae, and 14 min for B. subtilis spores. D-values of bacteria and yeast were dependent on the initial inoculation concentration, while the D-value of B. subtilis spores showed no correlation. When treated cells were observed with a scanning electron microscope, E. coli was more heavily damaged than S. aureus, S. cevevisiae exhibited peeling, and B. subtilis spores exhibited shrunken morphology. Results showed that APCP using helium/oxygen has many advantages as a sterilization method, especially in a clinical environment with conditions such as stable temperature, unlimited sample size, and no harmful gas production.