• Title/Summary/Keyword: Assay validation

Search Result 188, Processing Time 0.02 seconds

Quantitative Real-Time PCR of Porcine Parvovirus as a Model Virus for Cleaning Validation of Chromatography during Manufacture of Plasma Derivatives (혈장분획제제 제조공정에서 크로마토그래피 세척 검증을 위한 모델바이러스로서의 Porcine Parvovirus 정량)

  • Kil Tae Gun;Kim Won Jung;Lee Dong Hyuk;Kang Yong;Sung Hark Mo;Yoo Si Hyung;Park Sue-Nie;Kim In Seop
    • Korean Journal of Microbiology
    • /
    • v.41 no.3
    • /
    • pp.216-224
    • /
    • 2005
  • Chromatography has now been used successfully to provide the requisite purity for human plasma-derived biop-harmaceuticals such as coagulation factors and immunoglobulins. Recently, increasing attention has been focused on establishing efficient cleaning procedures to prevent potential contamination by microorganisms as well as carry-over contamination from batch to batch. The purpose of present study was to develop a cleaning validation system for the assurance of virus removal and/or inactivation during chromatography process. In order to establish an assay system for the validation of virus clearance during chromatography cleaning process, a quantitative real-time PCR method for porcine parvovirus(PPV) was developed, since PPV, a model virus for human parvovirus B19, has a high resistance to a range of physico-chemical treatment. Specific primers for amplification of PPV DNA was selected, and PPV DNA was quantified by use of SYBR Green I. The sensitivity of the assay was calculated to be 1.5 $TCID_{50}/ml$. The established real-time PCR assay was successfully applied to the validation of PPV removal and cleaning during SP-Sepharose cation chromatography for thrombin purification and Q-Sepharose anion chromatography for factor VIII purification. The comparative results obtained by real-time PCR assay and infectivity titrations suggested that the real-time PCR assay could be a useful method for chromatography cleaning validation and that it could have an additive effect on the interpretation and evaluation of virus clearance during the virus removal process.

Validation of Analytical Methods for Plasma Total Antioxidant Capacity by Comparing with Urinary 8-Isoprostane Level

  • Lee, Sang Gil;Wang, Taoran;Vance, Terrence M.;Hurbert, Patrice;Kim, Dae-Ok;Koo, Sung I.;Chun, Ock K.
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.2
    • /
    • pp.388-394
    • /
    • 2017
  • Although several analytical methods for measuring total antioxidant capacity (TAC) have been applied to biological samples, there were often dissimilar results due to the different principles of methods applied. Thus, this study aimed to validate four conventional analytical methods for measuring plasma TAC, including the ABTS assay, DPPH assay, FRAP assay, and ORAC assay, by comparing with urinary 8-isoprostane concentration. In addition, TAC results were compared with antioxidant enzyme activities including superoxide dismutase (SOD) and glutathione peroxidase in erythrocyte, and catalase in plasma. Plasma TAC measure by ABTS assay was strongly correlated with the result by FRAP assay. Plasma TAC by FRAP and ORAC assays were negatively correlated with erythrocyte SOD activity. The agreement among the four TAC assay methods and 8-isoprostane was determined using 95% prediction limits of linear regression, expressed as the mean of 8-isoprostane ${\pm}95%$ prediction limits. The ABTS method better agreed with 8-isoprostane than the other methods, demonstrating narrow prediction of limits. Furthermore, only plasma TAC determined by the ABTS assay was inversely correlated with urinary 8-isoprostane (r = -0.35, p < 0.05). In summary, the ABTS assay would be an appropriate method to measure overall plasma antioxidant capacity and predict the body's antioxidant status.

Quantitative Immunoassay for Polychlorinated Biphenyl Compounds in Electrical Insulating Oils

  • Kim In Soo
    • Proceedings of the Microbiological Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.119-127
    • /
    • 2000
  • The development and performance of a competitive indirect immunoassay for the quantitative measurement of polychlorinated biphenyl compounds in insulating oils is presented. Reagent preparation and the assay characterisation, optimisation and validation steps are described. The dynamic range of the assay for Aroclors 1254 and 1260 in methanol was $50-800 {\mu}g\;ml^{-1}$ with $50\%$ signal inhibition values of 217 and $ 212 {\mu}g\;ml^{-1}$ respectively. Impending legislation in the UK is likely to decree that oils containing $ >50 {\mu}g\;ml^{-1}$ PCB be considered contaminated. Assay sensitivity increased with the degree of PCB chlorination. The assay of structurally related compounds of environmental concern yielded cross-reactivity values of under $0.6\%$. The immunoassay proved reliable for the analysis of transformer oils containing $>70{\mu}g\;ml^{-1}$ PCB, but over-estimated PCB levels in oils containing $<20{\mu}g\;ml^{-1}$ of the analyte with the oils requiring pre-treatment using either solid-phase extraction techniques or washing with KOH-ethanol/sulphuric acid to remove matrix interferents. The analytical performance of the assay was compared against a commercially available semi-quantitative immunoassay kit for PCBs in soil and water.

  • PDF

TaqMan Probe Real-Time PCR for Quantitative Detection of Mycoplasma during Manufacture of Biologics (생물의약품 제조공정에서 마이코플라스마 정량 검출을 위한 TaqMan Probe Real-Time PCR)

  • Lee, Jae Il;Kim, In Seop
    • KSBB Journal
    • /
    • v.29 no.5
    • /
    • pp.361-371
    • /
    • 2014
  • Mycoplasma is well recognized as one of the most prevalent and serious microbial contaminants of biologic manufacturing processes. Conventional methods for mycoplasma testing, direct culture method and indirect indicator cell culture method, are lengthy, costly and less sensitive to noncultivable species. In this report, we describe a new TaqMan probe-based real-time PCR method for rapid and quantitative detection of mycoplasma contamination during manufacture of biologics. Universal mycoplasma primers were used for mycoplasma PCR and mycoplasma DNA was quantified by use of a specific TaqMan probe. Specificity, sensitivity, and robustness of the real-time PCR method was validated according to the European Pharmacopoeia. The validation results met required criteria to justify its use as a replacement for the culture method. The established real-time PCR assay was successfully applied to the detection of mycoplasma from human keratinocyte and mesenchymal stem cell as well as Vero cell lines artificially infected with mycoplasma. The overall results indicated that this rapid, specific, sensitive, and robust assay can be reliably used for quantitative detection of mycoplasma contamination during manufacture of biologics.

Different Real Time PCR Approaches for the Fine Quantification of SNP's Alleles in DNA Pools: Assays Development, Characterization and Pre-validation

  • Mattarucchi, Elia;Marsoni, Milena;Binelli, Giorgio;Passi, Alberto;Lo Curto, Francesco;Pasquali, Francesco;Porta, Giovanni
    • BMB Reports
    • /
    • v.38 no.5
    • /
    • pp.555-562
    • /
    • 2005
  • Single nucleotide polymorphisms (SNPs) are becoming the most common type of markers used in genetic analysis. In the present report a SNP has been chosen to test the applicability of Real Time PCR to discriminate and quantify SNPs alleles on DNA pools. Amplification Refractory Mutation System (ARMS) and Mismatch Amplification Mutation Assay (MAMA) has been applied. Each assay has been pre-validated testing specificity and performances (linearity, PCR efficiency, interference limit, limit of detection, limit of quantification, precision and accuracy). Both the approaches achieve a precise and accurate estimation of the allele frequencies on pooled DNA samples in the range from 5% to 95% and don't require standard curves or calibrators. The lowest measurement that could be significantly distinguished from the background noise has been determined around the 1% for both the approaches, allowing to extend the range of quantifications from 1% to 99%. Furthermore applicability of Real Time PCR assays for general diagnostic purposes is discussed.

Development of Alternative Assay Method without Hazardous Reagent, Chloroform for Urazamide Tablets in Korean Pharmaceutical Codex (우라자미드 정의 유해시약 대체 시험법의 개발)

  • Lee, Yoo Rim;Kim, Hyun Ji;Seo, Narae;Kim, Kyeong Ho
    • YAKHAK HOEJI
    • /
    • v.58 no.2
    • /
    • pp.125-128
    • /
    • 2014
  • We developed an alternative assay method without hazardous reagent of chloroform for urazamide tablets in Korean Pharmaceutical Codex. The HPLC analytical method was validated by system suitability, linearity, precision, accuracy and robustness. The linearity of the calibration curves in the desired concentration range is good ($r^2$ >0.999). Precision was obtained less than RSD 1.17%. Accuracy was obtained with recoveries in range of 98.12% and 99.47%. The developed assay could be expected to become valuable tools for revising the Korean Pharmaceutical Codex.

Real-Time RT-PCR for Quantitative Detection of Bovine Viral Diarrhoea Virus during Manufacture of Biologics (생물의약품 제조공정에서 Bovine Viral Diarrhoea Virus 정량 검출을 위한 Real-Time RT-PCR)

  • Cho, Hang-Mee;Lee, Dong-Hyuck;Kim, Hyun-Mi;Kim, In-Seop
    • Microbiology and Biotechnology Letters
    • /
    • v.36 no.1
    • /
    • pp.34-42
    • /
    • 2008
  • Bovine blood, cell, tissue, and organ are used as raw materials for manufacturing biologics such as biopharmaceuticals, tissue engineered products, and cell therapy. Manufacturing processes for the biologics using bovine materials have the risk of viral contamination. Therefore viral validation is essential in ensuring the safety of the products. Bovine viral diarrhoea virus (BVDV) is the most common bovine pathogen and has widely been known as a contaminant of biologics. In order to establish the validation system for the BVDV safety of biologics, a real-time RT-PCR method was developed for quantitative detection of BVDV contamination in raw materials, manufacturing processes, and final products. Specific primers for amplification of BVDV RNA was selected, and BVDV RNA was quantified by use of SYBR Green I. The sensitivity of the assay was calculated to be 1 $TCID_{50}/mL$. The rent-time RT-PCR method was validated to be reproducible and very specific to BVDV. The established real-time RT-PCR assay was successfully applied to the validation of Chinese hamster ovary (CHO) cell artificially infected with BVDV. BVDV RNA could be quantified in CHO cell as well as culture supernatant. Also the real-time RT-PCR assay could detect $10TCID_{50}/mL$ of BVDV artificially contaminated in bovine collagen.

Multiplex Reverse Transcription-PCR for Simultaneous Detection of Reovirus, Bovine Viral Diarrhea Virus, and Bovine Parainfluenza Virus during the Manufacture of Cell Culture-derived Biopharmaceuticals (세포배양 유래 생물의약품 제조공정에서 Reovirus, Bovine Viral Diarrhea Virus, Bovine Parainfluenza Virus 동시 검출을 위한 Multiplex Reverse Transcription-PCR)

  • Oh, Seon Hwan;Bae, Jung Eun;Kim, In Seop
    • Microbiology and Biotechnology Letters
    • /
    • v.40 no.4
    • /
    • pp.339-347
    • /
    • 2012
  • Viral safety is an important prerequisite for clinical preparations of mammalian cell culture-derived biopharmaceuticals, because numerous adventitious viruses have been contaminated during the manufacturing process. In particular, Chinese hamster ovary (CHO) cells are highly susceptible to several RNA viruses including reovirus (Reo), bovine viral diarrhea virus (BVDV), and bovine parainfluenza virus (BPIV) and there have been reports of such viral contaminations. Therefore, viral detection during the CHO cell process is necessary to ensure the safety of biopharmaceuticals against viruses. In this study, a multiplex reverse transcription (RT)-PCR assay was developed and subsequently evaluated for its effectiveness as a means to simultaneously detect Reo, BVDV, and BPIV during the manufacture of cell culture-derived biopharmaceuticals. Specific primers for Reo, BVDV, and BPIV were selected, and a multiplex RT-PCR was optimized. The sensitivity of the assay for simultaneous amplification of all viral target RNAs was $7.76{\times}10^2\;TCID_{50}/ml$ for Reo, $7.44{\times}10^1\;TCID_{50}/ml$ for BVDV, and $6.75{\times}10^1\;TCID_{50}/ml$ for BPIV. The multiplex RT-PCR was proven to be very specific to Reo, BVDV, and BPIV and was subsequently applied to the validation of CHO cells artificially infected with each virus. It could detect each viral RNA from CHO cells as well as culture supernatants. Therefore, it was concluded that the multiplex RT-PCR assay can be applied to detection of the adventitious viruses during the manufacture of cell culture-derived biopharmaceuticals.

Development and validation of enzyme-linked immunosorbent assay for anti-mouse pertussis immunoglobulin G using international reference anti-Bordetella pertussis mouse serum NIBSC 97/642

  • Kyu-Ri Kang;Yi-Hyeon Kwon;Gyu-Won Cho;Gi-Sub Choi;Joon-Hwan Ji;Hyun-Mi Kang;Soo-Young Lee;Jin-Han Kang
    • Clinical and Experimental Vaccine Research
    • /
    • v.13 no.3
    • /
    • pp.242-252
    • /
    • 2024
  • Purpose: In this study, an in-house enzyme-linked immunosorbent assay (ELISA) was developed and validated. The titer of ELISA was calculated using the reference line (RFL) method based on the standard curve drawn using the international reference anti-mouse serum NIBSC (National Institute for Biological Standards and Control) 97/642. Materials and Methods: In the development step, signal to noise was depicted to select the buffers that showed the most appropriate ratio. In the validation step, standard range, precision, dilution linearity, and specificity were confirmed, and RFL and parallel line (PLL) methods were compared in precision and dilution linearity. Results: Coating concentration for plate was achieved at 0.1 ㎍/mL for pertussis toxin (PT), 0.15 ㎍/mL for filamentous hemagglutinin antigen (FHA), and 0.25 ㎍/mL for pertactin (PRN). The signal to noise ratio was 22.02 for PT, 14.93 for FHA, and 8.02 for PRN with 0.25% goat serum in phosphate-buffered saline (PBS) as a dilution buffer, and 2% skim milk in PBS as a blocking buffer. Based on the precision results, we assessed the lower limit of quantification by 1, 0.2, and 1.5 EU/mL concentration for PT, FHA, and PRN which met the ICH (International Council for Harmonization) M10 criteria of a 25% accuracy and total error of 40%. In specificity, homologous serum was spiked into heterologous serum and the accuracy met the criteria. There was no difference in the results between RFL and PLL calculations (p-value=0.3207 for PT, 0.7394 for FHA, 0.2109 for PRN). Conclusion: ELISA validated with RFL calculation method in this study is a relatively accurate assay for mouse humoral immunogenicity test.

Validation of One-Step Real-Time RT-PCR Assay in Combination with Automated RNA Extraction for Rapid Detection and Quantitation of Hepatitis C Virus RNA for Routine Testing in Clinical Specimens

  • KIM BYOUNG-GUK;JEONG HYE-SUNG;BAEK SUN-YOUNG;SHIN JIN-HO;KIM JAE-OK;MIN KYUNG-IL;RYU SEUNG-REL;MIN BOK-SOON;KIM DO-KEUN;JEONG YONG-SEOK;PARK SUE-NIE
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.3
    • /
    • pp.595-602
    • /
    • 2005
  • A one-step real-time quantitative RT-PCR assay in combination with automated RNA extraction was evaluated for routine testing of HCV RNA in the laboratory. Specific primers and probes were developed to detect 302 bp on 5'-UTR of HCV RNA. The assay was able to quantitate a dynamic linear range of $10^7-10^1$ HCV RNA copies/reaction ($R^2=0.997$). The synthetic HCV RNA standard of $1.84{\pm}0.1\;(mean{\pm}SD)$ copies developed in this study corresponded to 1 international unit (IU) of WHO International Standard for HCV RNA (96/790 I). The detection limit of the assay was 3 RNA copies/reaction (81 IU/ml) in plasma samples. The assay was comparable to the Amplicor HCV Monitor (Monitor) assay with correlation coefficient r=0.985, but was more sensitive than the Monitor assay. The assay could be completed within 3 h from RNA extraction to detection and data analysis for up to 32 samples. It allowed rapid RNA extraction, detection, and quantitation of HCV RNA in plasma samples. The method provided sufficient sensitivity and reproducibility and proved to be fast and labor-saving, so that it was suitable for high throughput HCV RNA test.