• 제목/요약/키워드: Artificial Shrinkage

검색결과 51건 처리시간 0.02초

The effect of artificial shrinkage and assisted hatching on the development of mouse blastocysts and cell number after vitrification

  • Kim, Hye Jin;Lee, Ki Hwan;Park, Sung Baek;Choi, Young Bae;Yang, Jung Bo
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제42권3호
    • /
    • pp.94-100
    • /
    • 2015
  • Objective: The goal of this study was to ascertain optimal assisted hatching (AH) method in frozen embryo transfer. We compared the effect of depending on whether mechanical or laser-AH was performed before or after the vitrification of embryo development rate and blastocyst cell numbers. Methods: In order to induce superovulation, pregnant mare's serum gonadotropin followed by human chorionic gonadotropin were injected into 4- to 5-week-old female mice. 2-cell embryos were then collected by flushing out the oviducts. The Expanded blastocysts were recovered after the collected embryos were incubated for 48 hours, and were then subjected to artificial shrinkage (AS) and cross-mechanical AH (cMAH) or quarter-laser zona thinning-AH (qLZT-AH) were carried out using the expanded blastocysts before or after vitrification. After 48 hours of incubation, followed by vitrification and thawing (V-T), and blastocysts were fluorescence stained and observed. Results: The rate of formation of hatched blastocysts after 24 and 72 hours of incubation was significantly higher in the AS/qLZT-AH/V-T group than in the other groups (p<0.05). The cell number of the inner cell mass was higher in AS/V-T/non-AH and AS/V-T/cMAH groups than those of others (p<0.05). In the control group, the number of trophectoderm and the total cell number were higher than in the AS-AH group (p<0.05). Conclusion: The above results suggest that AS and AH in vitrification of expanded blastocysts lead to the more efficient formation of hatched blastocysts in mice.

Effect of artificial shrinkage on clinical outcome in fresh blastocyst transfer cycles

  • Hur, Yong-Soo;Park, Jeong-Hyun;Ryu, Eun-Kyung;Yoon, Hae-Jin;Yoon, San-Hyun;Hur, Chang-Young;Lee, Won-Don;Lim, Jin-Ho
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제38권2호
    • /
    • pp.87-92
    • /
    • 2011
  • Objective: This study aimed to determine the safety and clinical effect of artificial shrinkage (AS) in terms of assisted hatching of fresh blastocysts. Also, we evaluated the correlation between patient age and the effect of AS on clinical outcome. Methods: Two AS methods, using a 29-gauge needle and laser pulse, were compared. Seventy-three blastocysts were shrunk using a 29-gauge needle and the same number of other blastocysts were shrunk by a laser pulse. We evaluated the shrunken blastocysts hourly and considered them viable if they re-expanded >70%. Blastocyst transfer cycles (n=134) were divided into two groups: a control group consisted of the cycles whose intact embryos were transferred (n=100), while the AS group consisted of the cycles whose embryos were replaced following AS (n=34). The implantation and pregnancy rates of the control group and AS group were compared ($p$ <0.05). Results: The re-expansion rates of the 29-gauge needle and laser pulse AS groups were similar (56 [76.7%] vs. 62 [84.9%], respectively). All of the remaining shrunken blastocysts were re-expanded within 2 hours. There was no degeneration of shrunken blastocysts. The total and clinical pregnancy rate of the AS group (23 [67.6%]; 20 [58.8%], respectively) was significantly higher than that of the control group (47 [47.0%]; 39 [39.0%], respectively). In the older patient group, there was no difference in the clinical outcomes between the AS and control groups. Conclusion: These results suggest that AS of blastocoele cavity, followed by the transfer, would be a useful approach to improve the clinical outcome in cycles in which fresh blastocyst stage embryos are transferred.

A Fuzzy Logic Controller for the Level Swell and Shrinkage of the Nuclear Steam Generators

  • Moon, Byung-Soo;Moon, Je-Sun
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(1)
    • /
    • pp.260-265
    • /
    • 1995
  • Based on a thermohydraulic estimation of the level swell and shrinkage of the nuclear steam generators, a fuzzy logic controller is designed and tested to handle the problem of controlling the level swell and its restoration. The estimation is used to form an artificial system which is nearly the opposite of the level swell and shrinkage and a PD type controller is designed to control this system. This controller is added to a PI type ordinary fuzzy logic controller to form the proposed controller which is tested through various experiments on a scaled-down steam generator. It is found to perform efficiently so that the divergence of the level to a low limit can be avoided.

  • PDF

EAF-dust, 점토를 이용한 인공 경량 골재 콘크리트 개발 연구 (A Study for development of Artificial Light-Weight Aggregate Concrete using EAF Dust, Clay.)

  • 최영준;장봉석;김조웅;김유택;김화중
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.31-34
    • /
    • 2003
  • This study performed to develope the concrete using artificial lightweight aggregate(LWA) which contains stabilized heavy metal from EAF -dust. L W A is very effective to stabilize the heavy metal EAF-dust satisfied the general physical properties of aggregate except a absorptivity. The thermal conductivity and the dry shrinkage of LWAC were excellent compared with plain concrete and the strength was little fallen to.

  • PDF

유리화동결 전 인공수축과 보조부화술이 융해 후 생쥐 포배아의 발달에 미치는 영향 (Effects of the Artificial Shrinkage and Assisted Hatching Before Vitrification on the Development of the Vitrified Mouse Expanding Blastocysts)

  • 조덕현;고경래;정지혜;최종렬;주종길;이규섭
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제35권4호
    • /
    • pp.275-283
    • /
    • 2008
  • 목 적: 본 연구는 유리화동결 전 인공수축과 보조부화술 (부분투명대절개)이 유리화동결 후 생쥐 포배아의 생존율과 부화율에 미치는 영향을 알아보기 위해 시행되었다. 연구방법: 생쥐 2-세포기 배아를 획득하여 G1.1과 G2.2 배양액에서 포배아까지 배양하였다. 실험은 대조구군과 3개의 처리군으로 나누었다. 인공수축과 보조부화술 없이 동결한 군 (-AS/-AH)을 대조군으로 하였고, 보조부화술만 시행한 군 (-AS/+AH), 인공수축만 시행한 군 (+AS/-AH), 인공수축과 보조부화술을 동시에 처리한 군 (+AS/+AH)을 처리군으로 하였다. 모든 포배아는 G10과 G10E20 용액에서 각각 3분씩 평형을 실시하였고, G25E25 유리화용액에 노출직후 capped pulled-straw에 mouth 피펫으로 부하하여 유리화동결하였다. 융해 후 24시간 동안 배양하면서 생존율과 부화율을 조사하였다. 결 과: 인공수축을 시행한 후 보조부화술을 시행한 군 (+AS/+AH)과 보조부화술을 시행하지 않은 군 (+AS/-AH)에서의 생존율과 부화율은 각각 98%와 100%, 92%와 41%였으며, 인공수축을 시행하지 않고 보조부화술을 시행한 군(-AS/+AH)과 보조부화술을 시행하지 않은 군 (-AS/-AH, 대조군)에서의 생존율과 부화율은 각각 54%와 96%, 58%와 34%를 나타내어 인공수축과 보조부화술 생쥐 포배아의 생존율과 부화율 향상에 매우 효과적인 방법임을 알 수 있었다 (p<0.01). 또한 capped pulled-straw라고 명명한 스트로우를 이용한 유리화동결은 융해 후 회수율이 100%였으며, 동결과 융해과정에 매우 편리하여 배아의 유리화동결에 매우 유용할 것으로 생각된다. 결 론: 인공수축과 보조부화술은 포배아의 유리화동결 후 생존율과 부화율을 유의하게 향상시켜 포배아의 동결보존에 매우 효과적인 방법으로 생각된다.

A COMPARATIVE STUDY ON THE DIMENSIONAL CHANGE OF THE DIFFERENT DENTURE BASES

  • Kim, Myung-Joo;Kim, Chang-Whe
    • 대한치과보철학회지
    • /
    • 제44권6호
    • /
    • pp.712-721
    • /
    • 2006
  • Statement of problem. Acrylic resin is most commonly used for denture bases. However, acrylic resin has week points of volumetric shrinkage during polymerization that reduces denture fit. The expandability of POSS (Polyhedral Oligomeric Silsesquioxane) containing polymer could be expected to reduce the polymerization shrinkage of denture bases and would increase the adaptability of the denture to the tissue. Purpose. The purpose of this study was to compare the dimensional stability in the conventional acrylic resin base, POSS-containing acrylic resin base, and metal bases. Materials and methods. Thirty six maxillary edentulous casts and dentures of different base were fabricated. Tooth movement and tissue contour change of denture after processing (resin curing, deflasking, decasting and finishing without polishing) and immersion in artificial saliva at $37^{\circ}C$ for 1 week and 4 weeks were measured using digital measuring microscope and threedimensional laser scanner. Results. The results were as follows: 1. The conventional resin group showed significant (p<0.01) dimensional change throughout the procedure (processing and immersion in artificial saliva). 2. After processing, the metal group and POSS resin group showed lower linear and 3-dimensional change than conventional resin group (p<0.01). 3. There was no statistically significant linear and 3-dimensional change after immersion for 1 week and 4 weeks in metal and POSS resin group. 4. In all groups, the midline and alveolar ridge crest area presented smaller 3-dimensional change compared with vestibule and posterior palatal seal area after processing and soaking in artificial saliva for 1 week and 4 weeks (p<0.01). Conclusion. In this study, a reinforced acrylic-based resin with POSS showed good dimensional stability.

A comparative study on the accuracies of resin denture bases and metal denture bases

  • Park Hwee-Woong;Kim Chang-Whe;Kim Yung-Soo
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.250-259
    • /
    • 2001
  • Since the late 1930s, acrylic resins have been the materials of choice for the fabrication of complete denture bases. It has excellent esthetic properties, adequate strength, low water sorption, and low solubility. But acrylic resin has disadvantage of processing shrinkage that reduces denture retention and accuracy of denture occlusion. Metals also have been used in denture base material. Metals used in denture bases display excellent strength and dimensional stability. The major disadvantages associated with metal denture bases include increased cost, difficulty in fabrication, compromised esthetic qualities, and inability to re-base. The purpose of this study is to compare the artificial tooth movements of complete dentures with resin bases and metal bases after curing, deflasking, polishing immersion in water for 1 week and 4 weeks. Twenty-four maxillary complete resin denture bases with artificial teeth were fabricated. Twelve of them were resin based and other twelve of them were metal based. Fine crosses were marked on the incisal edges of right central incisors and distobuccal cusps of be second molars. Measurements were done for the changes of distances of reference points at the time of wax denture, after deflasking after decasting after polishing after immersion in water for 1 week and 4 weeks Meaurements were done to the accuracy of 0.001mm with a measuring microscope. The results were as follows : 1. Metal base showed significantly less tooth movement than resin base after curing and decasting (p<0.01). 2. Metal base showed significantly less tooth movement than resin base after polishing (p<0.01). 3. After immersion in water for 1 week and 4 weeks, metal base showed less movement than resin base. Difference was significant for anterior-posterior distances (p<0.01), but not significant for molar-to-molar distance (p>0.01). 4. 1 week and 4 weeks of immersion failed to compensate the initial processing shrinkage of metal and resin bases (p>0.01).

  • PDF

DLP 프린터로 출력한 임시의치용 전악 인공치아의 후경화에 따른 변형 분석 (Analysis of deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a DLP printer)

  • 김동연;이광영
    • 대한치과기공학회지
    • /
    • 제43권2호
    • /
    • pp.48-55
    • /
    • 2021
  • Purpose: This study aimed to analyze deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a digital light processing (DLP) printer. Methods: An edentulous model was prepared and an occlusal rim was produced. The edentulous model and occlusal rim were scanned using a model scanner. A complete denture was designed using a dental computer-aided design, and the denture base and artificial tooth were separated. Ten complete arch artificial teeth were printed using a 3D printer (DLP). Complete arch artificial teeth was classified into the following three groups: a group no post-curing (NC), a group with 10 minutes post-curing (10M), and a group with 20 minutes post-curing (20M). Specimens were scanned using a model scanner. The scanned data were overlapped with the reference data. Statistical analysis was performed using one-way ANOVA analysis of variance, Kruskal-Wallis test, and Mann-Whitney U test (α=0.05). Results: Regarding the overall deviation of complete arch artificial teeth, the NC group showed the lowest mean deviation of 111.13 ㎛ and the 20M group showed the highest mean deviation of 131.03 ㎛. There were statistically significant differences among the three groups (p<0.05). Conclusion: The complete arch artificial tooth showed deformation due to post-curing. In addition, the largest shrinkage deformation was observed at 10 minutes of post-curing, whereas the least deformation was observed at 20 minutes.

인간포배기 배아의 효과적인 유리화 동결법의 개발을 위한 연구 (Study on the Development of Efficient Vitrification of Human Blastocysts)

  • 이상민;이주희;이상원;이승민;윤산현;임진호;박흠대;이성구
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제30권3호
    • /
    • pp.241-248
    • /
    • 2003
  • Objective: The purpose of this study was to evaluate the survival rate of vitrified blastocyst according to the freezing vessels, equilibration time in cryoprotectant and artificial dehydration method. Methods: Human blastocysts were vitrified after loading onto the plastic straw, open-pulled straw (OPS), electron microscopy grid (EM grid) for 1.5 min or 3 min. They also were directly plunged into LN2 within 30sec. For artificial shrinkage of blastocysts, 36 gauge fine needle was pushed at the cellular junction of the trophectoderm into the blstocoele cavity until it shrank without damage of inner cell mass. Results: The survival rate of vitrified blastocysts on plastic straw, OPS, EM grid as freezing vessels were 26.7, 13.0 and 60.5%, respectively. The survival rate of EM grid was significantly higher than that of plastic straw and OPS (p<0.05). For 1.5 min equilibrium, the survival rates of early blastocyst (EB), middle blastocyst (MB) and late blastocyst (LB) were 64.4, 81.0, and 20.0% respectively. For 3 min equilibrium, the survival rates of EB, MB, and LB were 69.9, 50.0 and 57.5% respectively. The survival rates of EB and MB were significantly higher than that of LB in 1.5 min equilibrium group (p<0.05), however, the significance was not observed in 3 min equilibrium groups. In cytoplasmic shrinkage before vitrification, the survival rates of EB, MB and LB were 92.9, 100 and 75.9% respectively. The survival rate of MB was significantly higher than that of LB (p<0.05). The survival rates of vitrified blastocysts by artificial dehydration and slow-frozen blastocysts were not significantly different as 88.9 and 66.7%, respectively. Conclusion: This study showed that the vitrification of human blastocysts using EM grid and artificial dehydration is an effective method. Therefore, these methods would be an useful techniques for blastocyst cryopreservation.