• 제목/요약/키워드: Arterial Pulse

검색결과 220건 처리시간 0.028초

Arterial Stiffness is Associated With Diabetic Retinopathy in Korean Type 2 Diabetic Patients

  • Yun, Yong-Woon;Shin, Min-Ho;Lee, Young-Hoon;Rhee, Jung-Ae;Choi, Jin-Su
    • Journal of Preventive Medicine and Public Health
    • /
    • 제44권6호
    • /
    • pp.260-266
    • /
    • 2011
  • Objectives: We evaluated the association between common carotid artery intima-media thickness (CCA-IMT), brachialankle pulse wave velocity (baPWV), carotid plaque, and peripheral arterial disease (PAD) as indicators of macroangiopathy and diabetic retinopathy as an indicator of microangiopathy in type 2 diabetic patients. Methods: We analyzed 605 type 2 diabetic patients registered at a public health center in Korea. Following overnight fasting, venous blood and urine samples were collected and analyzed. The CCA-IMT, levels of carotid plaque, baPWV, and ankle-brachial index (ABI) of the subjects were assessed. We used non-mydriatic fundus photography to diagnose diabetic retinopathy. Multiple logistic regression analyses were used to evaluate the association between macroangiopathy and diabetic retinopathy. CCA-IMT and baPWV were divided into tertiles: CCA-IMT, 0.39 to 0.65 mm, 0.66 to 0.78 mm, and 0.79 to 1.30 mm; baPWV, 9.9 to 15.8 m/s, 15.9 to 18.9 m/s, and 19.0 to 38.0 m/s. Results: The association between baPWV and diabetic retinopathy remained significant after adjustment, with an increasing odds ratio (OR) in the second tertile (OR, 2.41; 95% confidence interval [CI], 1.27 to 4.55) and the third tertile (OR, 4.63; 95% CI, 2.33 to 9.21). No significant differences were observed in carotid plaque, PAD, and each tertile of CCA-IMT. Conclusions: BaPWV was associated with diabetic retinopathy, while CCA-IMT, carotid plaque, and PAD were not. This study suggests that the association between macroangiopathy and microangiopathy may be attributable to functional processes rather than structural processes within the vascular system.

비침습적 맥파 측정을 위한 압력센서 패키징에 관한 연구 (Pressure Sensor Packaging for Non-invasive Pulse Wave Measurement)

  • 김은근;남기창;허현;허영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1978.1_1979.1
    • /
    • 2009
  • In this paper, we have proposed and demonstrated a tonometry sensor array for measuring arterial pulse pressure. A sensor module consists of 7 piezoresistive pressure sensor array. Wire-bonded connection was provided between silicon chip and lead frame. PDMS(poly-dimethylsiloxane) was coated on the sensor array to protect fragile sensor while faithfully transmitting the pressure of radial artery to the sensor. Tonometric pulse pressure can be measured by this packaged sensor array that provides the pressure value versus the output voltage.

  • PDF

모듈화를 이용한 펄스 옥시메터의 신호처리 개선 (An Improvement of Signal Processing of Pulse Oximeter Using Modulization)

  • 이한욱;이주원;이종희;조원래;장두봉;김영일;이건기
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(5)
    • /
    • pp.117-120
    • /
    • 2000
  • Pulse oximetry is a well established non-invasive optical technique for monitoring the SpO$_2$ during anaesthesia, recovery and intensive care. Pulse oximeters determine the oxygen saturation level of blood by measuring the light absorption of arterial blood. The sensors consists of red and infrared light sources and photodetectors. In the measurement of the hemoglobin oxygen saturation, conventional method has required the technique of filtering of remove the noise, and of complex signal processing algorithm. So much time have required to signal processing. In this research, we separate AC signal and DC signal in the stage of signal detection. We filter the noise from each signal and convert A/D. We obtain the SpO$_2$ using the DSP algorithm.

  • PDF

펄스옥시미터 개발에 관한 연구 (A Study on Implemention of Pulse Oximeter System)

  • 박연순;김근이;임현수;양동지;허웅
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 춘계학술대회
    • /
    • pp.116-119
    • /
    • 1993
  • In this paper, we implemented a pulse wave type oximeter system that continuously measure the of oxyhemoglobin saturation of the arterial blood(SaO2) and pulse rate with non-invasively. We use the transmission type and reflection type transducer for comparison the percentage of hemoglobin oxgen saturation. The light Iron the two kind of LEDs is transmitted through the tissue, then received by a single photodiode with alternatively. By the phase sensitive detection circuit, the output of the photodiode is separated in to red and near infrared signal. We calculated a ratio of light transmittance between two kind of LEDs, and then, it is applied to the oxgen saturation coefficent calculation formular.

  • PDF

사암침 소장정격을 이용한 Meniere's disease의 발작성 현훈 치험 1례 (A Clinical Report on Episodic Vertigo with Meniere's Disease Treated by Saam Acupuncture Sojangjungkyuk)

  • 오기철
    • 대한한의진단학회지
    • /
    • 제16권1호
    • /
    • pp.35-44
    • /
    • 2012
  • Objectives The purpose of this study is to report the effect of oriental demonstration treatment for episodic vertigo of Meniere's disease. Meniere's Disease characterized by recurrent prostrating episodic vertigo, nausea, vomiting, sensory hearing loss, tinnitus, and a feeling of fullness in the ear associated with generalized dilation of the membranous labyrinth (endolymphatic hydrops). The cause of Meniere's disease is unknown, and the pathophysiology is poorly understood. Methods We experienced one case of Meniere's disease treated with Asian medical treatment, acupuncture and herbal medication. 64-year-old female patient was diagnosed with Meniere's disease by western medical doctor. Methods: Saam acupuncture Sojangjungkyuk applied to the patient. Results After treatment her episodic vertigo, nausea, vomiting and endolymphatic hydrops were decreased but the level of tinnitus it was not improved as much as other symptoms. Conclusions Saam Acupuncture of Asian medical treatment could be safe and effective.

맥진기술동향 조사를 통한 맥진기 개발방안 제안 (Suggestion on an Innovative Pulse Diagnosis System based on Technical Trend Analysis)

  • 이유정;이전;김종열
    • 동의생리병리학회지
    • /
    • 제23권1호
    • /
    • pp.174-179
    • /
    • 2009
  • Arterial pulse palpation is an important diagnostic method in Oriental Medicine, particularly for obtaining information about a patient's health conditions or illness, or for confirming a diagnostic conclusion based on the patient's pulsation. The pulse analyzer is both a leading Oriental Medical equipment and a promising tool with such a strong industrial ripple effect that it was selected as one of the four strategic tools for world Oriental Medical instrument market domination at a recent survey. Although various pulse analyzers had been developed, however, most of these were not widely used for clinical diagnosis, due perhaps to lack of the appliance's reliability caused by its inability to reflect the requirements of the clinicians. Thus, in this thesis, the clinical requirements for the pulse analyzer were identified and analyzed by conducting a questionnaire survey among Oriental Medicine clinicians. By looking into the basic functions of a pulse analyzer, the required measurement time, and the medical insurance fee required were determined and among others, the appliance's specific requirements were determined. Moreover, by investigating on the latest patent trend, the technical elements that are needed for the development of a next-generation pulse analyzer were identified. Through these processes, the flow of the technology that must be developed for the pulse analyzer was determined, and the direction for the development of the specific pulse analyzer hardware, sensor, and diagnostic algorithm was identified and proposed.

지능형 맥진기 구현 (Implementation of Intelligence Pulse Wave Detection System)

  • 홍유식;유준상;장세진;선승호;이우범;남동현;유문성;최명복;이상석
    • 한국인터넷방송통신학회논문지
    • /
    • 제13권2호
    • /
    • pp.245-254
    • /
    • 2013
  • 동양 의학에서는 맥파를 분석해서 많은 질병을 분류하고 치료하고 있다. 그러나 현재까지 맥파를 분석하는 방법은 매우 주관적인 방법을 사용하기 때문에 신뢰도가 떨어지는 문제점이 발생한다. 뿐만 아니라, 기존 맥진기의 문제점으로는 요골동맥에 정확하게 맥진 센서가 위치하지 못하기 때문에 측정 위치에 따라 측정결과가 상이하고 측정절차에 매우 민감하여 높은 재현성을 실현 못하고 있는 실정이다. 본 논문에서는 이러한 문제점을 해결하기 위해서 홀센서를 이용한 휴대용 맥진기를 이용해서 실맥 및 허맥을 분석 하는 연구 결과를 제안하였다. SPSS 통계 기법으로 분석한 실맥 및 허맥 최종 분석결과, 95% 신뢰도 구간에서 N.time(절흔점 시간) 및 S.amp (상승파형 크기) 평균치가 유의성이 있음을 입증하였다.

총안 맥진을 위한 맥동검출기 개발에 관한 연구( I ) (A Study on the Radial Pulse Detection System for the Total Macjin( I ))

  • 김규상;양승렬;한순천;박영배;김정국;허웅
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.551-554
    • /
    • 1999
  • In this paper, we developed a radial pulse transducer that has strain-gauge cantilever type load cell for total pulse detection on chongu arterial. The transducer consist of load cell and driving electronic circuits. Load cell consist of cantilever and two metal film strain gauge. The Pressure signal from chongu artery is delivered to load cell using artery rider that attached to cantilever Therefore the pressure signal convert to voltage signals by the developed transducer As the results of experiment, the developed transducer has very good linearity at pressure to voltage conversion. The total pulse detection transducer can detected three kinds of chongu artery pulse with conveniently.

  • PDF

Fuzzy Simulation of a Multi-electronic Acupuncture System and Clip-type Pulsimeter Equipped with a Magnetic Sensing Hall Device

  • Hong, You-Sik;Rhee, Jin-Kyu;Kim, Han-Kyu;Son, Il-Ho;Yoon, Woo-Sung;Lee, Nam-Kyu;Park, Do-Young;Kim, Keun-Ho;Kim, Yong-Jin;Khajidmaa, P.;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • 제19권3호
    • /
    • pp.255-260
    • /
    • 2014
  • A portable clip-type pulsimeter equipped with a magnetic sensing Hall device has been developed to raise the accuracy of oriental disease diagnosis and therapy by convergence of magnetism and oriental medicine. To improve accuracy and reliability of conventional pulsimeter due to subjective analysis of the pulse wave and measuring position dependency of the arterial pulse sensor, the fuzzy algorithm was applied to analyze the strong- and weak-pulse wave symptom. Optimal time for electronic acupuncture was calculated using fuzzy rules and interference were drawn from objective data in view of pre-treatment. Moreover, the electrical characteristics of the pain parts that respond to acupuncture point were applied in view of post-treatment to propose the scientific pulse wave algorithm and simulation experiment.

마왕퇴(馬王堆) 발굴(發掘) 경맥서(經脈書) 비음경(臂陰經) 연구(硏究) : 경맥(經脈)의 직접(直接) 지각(知覺) (Hand-Yin Meridians of Unearthed Mawangdui Medical Texts Were Described by the Haptic Exploration)

  • 송석모
    • 한국의사학회지
    • /
    • 제35권1호
    • /
    • pp.87-99
    • /
    • 2022
  • The purpose of this paper is to test the hypothesis that some early Chinese meridians were described by haptic exploration of the arterial pulse. The method is as follows: First, the relevant passages of the Mawangdui medical texts, the oldest meridian monographs, are translated based on perceptual anatomy. Second, the pulse is haptically searched for in the palm, lower arm, upper arm, armpit, and torso of the human body. Finally, their locations are compared with the translation. As a result, It was confirmed that the pulse locations detected on the body were mostly consistent with the routes of the meridians described in the texts. So meridians were haptically detectable pulse routes. What is known today as the flow direction of hand-yin meridians is actually the direction of searching the pulse. Our result runs counter to Huang Longxiang's claim that the route of the meridians are virtual routes set by speculation. Our findings also dispute Vivien Shaw's claim that the meridians of Mawangdui medical texts were discovered by anatomical dissection. They also refute the claim that meridians were discovered by the extrasensory perception of the inner sight (內觀) and the subjective experience of the meridian sensitive person. The hand-yin meridians of Mawangdui medical texts are well described so that anyone can find them by touching them with their fingers.