• Title/Summary/Keyword: Arterial Pulse

Search Result 220, Processing Time 0.029 seconds

Comparison of Hemodynamic Energy between Expanded Polytetrafluoroethylene and Dacron Artificial Vessels

  • Lim, Jaekwan;Won, Jong Yun;Ahn, Chi Bum;Kim, Jieon;Kim, Hee Jung;Jung, Jae Seung
    • Journal of Chest Surgery
    • /
    • v.54 no.2
    • /
    • pp.81-87
    • /
    • 2021
  • Background: Artificial grafts such as polyethylene terephthalate (Dacron) and expanded polytetrafluoroethylene (ePTFE) are used for various cardiovascular surgical procedures. The compliance properties of prosthetic grafts could affect hemodynamic energy, which can be measured using the energy-equivalent pressure (EEP) and surplus hemodynamic energy (SHE). We investigated changes in the hemodynamic energy of prosthetic grafts. Methods: In a simulation test, the changes in EEP for these grafts were estimated using COMSOL MULTIPHYSICS. The Young modulus, Poisson ratio, and density were used to analyze the grafts' material properties, and pre- and post-graft EEP values were obtained by computing the product of the pressure and velocity. In an in vivo study, Dacron and ePTFE grafts were anastomosed in an end-to-side fashion on the descending thoracic aorta of swine. The pulsatile pump flow was fixed at 2 L/min. Real-time flow and pressure were measured at the distal part of each graft, while clamping the other graft and the descending thoracic aorta. EEP and SHE were calculated and compared. Results: In the simulation test, the mean arterial pressure decreased by 39% for all simulations. EEP decreased by 42% for both grafts, and by around 55% for the native blood vessels after grafting. The in vivo test showed no significant difference between both grafts in terms of EEP and SHE. Conclusion: The post-graft hemodynamic energy was not different between the Dacron and ePTFE grafts. Artificial grafts are less compliant than native blood vessels; however, they can deliver pulsatile blood flow and hemodynamic energy without any significant energy loss.

Acute Lower Limb Ischemia Associated with COVID-19 (코로나바이러스감염증-19 이후 발생한 급성 하지허혈증)

  • Kim, Hyung Suh;Suh, Jin Soo;Choi, Jun Young
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.5
    • /
    • pp.450-454
    • /
    • 2021
  • A 75-year-old male patient without any significant medical and habitual risk factors for acute atherosclerosis obliterans except for hypertension was diagnosed with coronavirus disease 2019 with dyspnea, coughing, and mild fever. After a week of hospitalization, he complained of right foot pain and numbness. The symptoms were aggravated during the next week, resulting in a complete toe color change and loss of dorsalis artery pulse. Enhanced 3-dimensional computed tomography angiography revealed thrombus formation in the right common iliac artery and a loss of blood flow below the popliteal artery on both sides. The patient underwent percutaneous balloon angioplasty with stent insertion followed by medical therapy for anticoagulation. The clinical symptoms immediately were improved after the intervention, but the great toe necrosis was not recovered. Finally, amputation of the great toe was performed.

Predicting the resting metabolic rate of young and middle-aged healthy Korean adults: A preliminary study

  • Park, Hun-Young;Jung, Won-Sang;Hwang, Hyejung;Kim, Sung-Woo;Kim, Jisu;Lim, Kiwon
    • Korean Journal of Exercise Nutrition
    • /
    • v.24 no.1
    • /
    • pp.9-13
    • /
    • 2020
  • [Purpose] This preliminary study aimed to develop a regression model to estimate the resting metabolic rate (RMR) of young and middle-aged Koreans using various easy-to-measure dependent variables. [Methods] The RMR and the dependent variables for its estimation (e.g. age, height, body mass index, fat-free mass; FFM, fat mass, % body fat, systolic blood pressure, diastolic blood pressure, mean arterial pressure, pulse pressure, and resting heart rate) were measured in 53 young (male n = 18, female n = 16) and middle-aged (male n = 5, female n = 14) healthy adults. Statistical analysis was performed to develop an RMR estimation regression model using the stepwise regression method. [Results] We confirmed that FFM and age were important variables in both the regression models based on the regression coefficients. Mean explanatory power of RMR1 regression models estimated only by FFM was 66.7% (R2) and 66.0% (adjusted R2), while mean standard errors of estimates (SEE) was 219.85 kcal/day. Additionally, mean explanatory power of RMR2 regression models developed by FFM and age were 70.0% (R2) and 68.8% (adjusted R2), while the mean SEE was 210.64 kcal/day. There was no significant difference between the measured RMR by the canopy method using a metabolic gas analyzer and the predicted RMR by RMR1 and RMR2 equations. [Conclusion] This preliminary study developed a regression model to estimate the RMR of young and middle-age healthy Koreans. The regression model was as follows: RMR1 = 24.383 × FFM + 634.310, RMR2 = 23.691 × FFM - 5.745 × age + 852.341.

Nocturnal Arterial Oxygen Saturation Monitoring in Patients with Respiratory Disease (호흡기 질환 환자들에서 야간 동맥혈 산소포화도 감시 성적)

  • Choi, In-Seon;Yang, Jae-Beom;Kim, Young-Chul;Chung, Ik-Joo;Kang, Yu-Ho;Koh, Yeoung-Il;Park, Sang-Seon;Lee, Min-Su;Park, Kyung-Ok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.2
    • /
    • pp.103-110
    • /
    • 1994
  • To find out the predictors of nocturnal arterial oxygen desaturation in patients with respiratory diseases, transcutaneous oxygen saturation($StcO_2$) monitoring studies using a pulse oximeter were performed during sleep in 20 patients. $StcO_2$ was decreased more than 4% from the baseline value in 18 patients(90%) and more than 10%("Desaturator") in 8(40%). Five of the seven patients(71.4%) with awake $PaO_2$<60mmHg and three of the thirteen patients(23.1%) with awake $PaO_2{\geq}60mmHg$ were "desaturators". The awake $PaO_2/FIO_2$ and $PaO_2/PAO_2$ could distinguish "desaturator" from "nondesaturator", and $PaO_2,\;SaO_2$ or $StcO_2$ could not. These results suggest that the nocturnal oxygen desaturation depends on the severity of the underlying disease rather than the baseline $PaO_2$. Anthropomorphic and lung function factors could not separate between "desaturator" and "non-desaturator", and about a quater of patients with a wake $PaO_2{\geq}60mmHg$ developed significant desaturation. Therefore, it is necessary to monitor the nocturnal arterial oxygen saturation in patients with respiratory diseases regardless of their severity of airflow obstruction or awake $PaO_2$.

  • PDF

Pulse wave velocity and ankle brachial index in adolescents with essential hypertension (본태성 고혈압 청소년에서 pulse wave velocity와 ankle brachial index에 대한 연구)

  • Joo, Sun Young;Cho, Ki Young;Cho, Su Jin;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.7
    • /
    • pp.769-776
    • /
    • 2006
  • Purpose : Pulse wave velocity(PWV) and ankle brachial index(ABI) are not only noninvasive methods used to assess arterial stiffness in adults, but also useful, simple ways to estimate the severity of hypertension, end stage renal disease and atherosclerosis in adults. But there are few studies on PWV and ABI in adolescents and children. In this study, hypertensive adolescents were compared to normal individuals to find out the usefulness of PWV as the index of progress in the disease. Methods : 413 teenagers were divided into three groups. The first group consisted of adolescents that only had hypertension(Group 1 : 23 teenagers). The second group consisted of the adolescents who had hypertension with obesity(Group 2 : 17 teenagers), and the last group was the normal subjects(Group 3 : 328 teenagers). Weight, height and body mass index were measured. Simultaneous measurements of systolic, diastolic and average blood pressure were obtained from the four extremities. PWV, ABI, ejection time and preejection period were also measured. Results : Right brachial-ankle PWV was significantly higher in both group 1 and group 2 compared with group 3, and significantly higher in group 2 compared with group 1. Likewise, left brachial-ankle PWV also showed significantly higher values in both group 1 and group 2 compared with group 3, and also higher values in group 2 compared with group 1. Positive correlations were found between the systolic, diastolic, average blood pressure and PWV. There were also positive correlations between the blood pressure and weight, body mass index. Conclusion : Higher PWV was demonstrated in adolescents with essential hypertension compared to normal subjects. Follow-up study is needed to evaluate the progress.

The Optimal Pulse Oxygen Saturation in Very Low Birth Weight or Very Preterm Infants (극소 저체중 출생아에서 경피적 산소포화도의 적정 범위)

  • You, Sun-Young;Kang, Hye-Jin;Kim, Min-Jung;Chang, Mea-Young
    • Neonatal Medicine
    • /
    • v.18 no.2
    • /
    • pp.320-327
    • /
    • 2011
  • Purpose: To determine the effect of changing practice guidelines designed to avoid hyperoxia or hypoxia in very low birth weight or very preterm infants. Methods: We analyzed a database of <1,500 g birth weight or <32 weeks of gestation infants who were born and admitted to the neonatal intensive care unit of Chungnam National University Hospital from January 2007 to July 2010. First, we defined the relationship between arterial partial pressure of oxygen ($PaO_2$) and pulse oxygen saturation ($SpO_2$). When we evaluated 96 pairs of $PaO_2$ and $SpO_2$ measurements, oxygen saturation was 90-94% at a $PaO_2$ of 43-79 mmHg on the oxyhemoglobin dissociation curve, according to pulse oximetry. Based on this observation, a change in practice was instituted in August 2008 with the objective of avoiding hypoxia and hyperoxia in preterm infants with targeting a $SpO_2$ 90-94% (period II). Before the change in practice, high alarms for $SpO_2$ were set at 100% and low alarms at 95% (period I). Results: Sixty-eight infants the met enrollment criteria and 38 (56%) were born during period II, after the change in $SpO_2$ targets. Demographic characteristics, except gender, were similar between the infants born in both periods. After correcting for the effect of confounding factors, the rates for mortality, severe retinopathy of prematurity, and IVH attended to be lower than those for infants in period II. No difference in the rate of patent ductus arteriosus needed to treat was observed. Conclusion: A change in the practice guidelines aimed at avoiding low oxygen saturation and hyperoxia did not increase neonatal complication rates and showed promising results, suggesting decreased mortality and improvements in short term morbidity. It is still unclear what range of oxygen saturation is appropriate for very preterm infants but the more careful saturation targeting guideline should be considered to prevent hypoxemic events and hyperoxia.

A Study of Optimal Model for the Circuit Configuration of Korean Pulsatile Extracorporeal Life Support System (T-PLS) (한국형 박동식 생명구조장치(T-PLS) 순환회로를 위한 최적화 모델 연구)

  • Lim Choon Hak;Son Ho Sung;Lee Jung Joo;Hwang Znuke;Lee Hye Won;Kim Kwang Taik;Sun Kyung
    • Journal of Chest Surgery
    • /
    • v.38 no.10 s.255
    • /
    • pp.661-668
    • /
    • 2005
  • Background: We have hypothesized that, if a low resistant gravity-flow membrane oxygenator is used, then the twin blood sacs of TPLS can be located at downstream of the membrane oxyenator, which may double the pulse rate at a given pump rate and increase the pump output. The purpose of this study was to determine the optimal configuration for the ECLS circuits by using the concept of pulse energy and pump output. Material and Method: Animals were randomly assigned to 2 groups in a total cardiopulmonary bypass model. In the serial group, a conventional membrane oxygenator was located between the twin blood sacs. In the parallel group, the twin blood sacs were placed downstream of the gravity-flow membrane oxygenator. Energy equivalent pressure (EEP) and pump output were collected at pump-setting rates of 30, 40, and 50 BPM. Result: At the given pump-setting rate, the pulse rate was doubled in the parallel group. Percent changes of mean arterial pressure to EEP were $13.0\pm1.7,\; 12.0\pm1.9\;and\;7.6\pm0.9\%$ in the parallel group, and $22.5\pm2.4,\; 23.2\pm1.9,\;and\;21.8\pm1.4\%$ in the serial group at 30, 40, and 50 BPM of pump-setting rates. Pump output was higher in the parallel circuit at 40 and 50 BPM of pump-setting rates $(3.1\pm0.2,\;3.7\pm0.2L/min\;vs.\;2.2\pm0.1\;and\;2.5\pm0.1L/min,\;respectively,\;p=0.01)$. Conclusion: Either parallel or serial circuit configuration of the ECLS generates effective pulsatility. As for the pump out, the parallel circuit configuration provides higher flow than the serial circuit configuration.

Application of a Single-pulsatile Extracorporeal Life Support System for Extracorporeal Membrane Oxygenation -An experimental study - (단일 박동형 생명구조장치의 인공폐 적용 -실험연구-)

  • Kim, Tae-Sik;Sun, Kyung;Lee, Kyu-Baek;Park, Sung-Young;Hwang, Jae-Joon;Son, Ho-Sung;Kim, Kwang-Taik;Kim. Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.37 no.3
    • /
    • pp.201-209
    • /
    • 2004
  • Extracorporeal life support (ECLS) system is a device for respiratory and/or heart failure treatment, and there have been many trials for development and clinical application in the world. Currently, a non-pulsatile blood pump is a standard for ECLS system. Although a pulsatile blood pump is advantageous in physiologic aspects, high pressure generated in the circuits and resultant blood cell trauma remain major concerns which make one reluctant to use a pulsatile blood pump in artificial lung circuits containing a membrane oxygenator. The study was designed to evaluate the hypothesis that placement of a pressure-relieving compliance chamber between a pulsatile pump and a membrane oxygenator might reduce the above mentioned side effects while providing physiologic pulsatile blood flow. The study was performed in a canine model of oleic acid induced acute lung injury (N=16). The animals were divided into three groups according to the type of pump used and the presence of the compliance chamber, In group 1, a non-pulsatile centrifugal pump was used as a control (n=6). In group 2 (n=4), a single-pulsatile pump was used. In group 3 (n=6), a single-pulsatile pump equipped with a compliance chamber was used. The experimental model was a partial bypass between the right atrium and the aorta at a pump flow of 1.8∼2 L/min for 2 hours. The observed parameters were focused on hemodynamic changes, intra-circuit pressure, laboratory studies for blood profile, and the effect on blood cell trauma. In hemodynamics, the pulsatile group II & III generated higher arterial pulse pressure (47$\pm$ 10 and 41 $\pm$ 9 mmHg) than the nonpulsatile group 1 (17 $\pm$ 7 mmHg, p<0.001). The intra-circuit pressure at membrane oxygenator were 222 $\pm$ 8 mmHg in group 1, 739 $\pm$ 35 mmHg in group 2, and 470 $\pm$ 17 mmHg in group 3 (p<0.001). At 2 hour bypass, arterial oxygen partial pressures were significantly higher in the pulsatile group 2 & 3 than in the non-pulsatile group 1 (77 $\pm$ 41 mmHg in group 1, 96 $\pm$ 48 mmHg in group 2, and 97 $\pm$ 25 mmHg in group 3: p<0.05). The levels of plasma free hemoglobin which was an indicator of blood cell trauma were lowest in group 1, highest in group 2, and significantly decreased in group 3 (55.7 $\pm$ 43.3, 162.8 $\pm$ 113.6, 82.5 $\pm$ 25.1 mg%, respectively; p<0.05). Other laboratory findings for blood profile were not different. The above results imply that the pulsatile blood pump is beneficial in oxygenation while deleterious in the aspects to high pressure generation in the circuits and blood cell trauma. However, when a pressure-relieving compliance chamber is applied between the pulsatile pump and a membrane oxygenator, it can significantly reduce the high circuit pressure and result in low blood cell trauma.

The Comparative Study of on Pump CABG during Pulsatile $(T-PLS^{TM})$ and Nonpulsatile $(Bio-pump^{TM})$ Perfusion (관상동맥우회술 시 사용된 박동성펌프$(T-PLS^{TM})$와 비박동성펌프$(Bio-pump^{TM})$의 비교연구)

  • Park Young-Woo;Her Keun;Lim Jae-Ung;Shin Hwa-Kyun;Won Yong-Soon
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.354-358
    • /
    • 2006
  • Background: Pulsatile pumps for extracorporeal circulation have been known to be better for tissue perfusion than non-pulsatile pumps but be detrimental to blood corpuscles. This study is intended to examine the risks and benefits of $T-PLS^{TM}$ through the comparison of clinical effects of $T-PLS^{TM}$ (pulsatile pump) and $Bio-pump^{TM}$ (non-pulsatile pump) used for coronary bypass surgery. Material and Method: The comparison was made on 40 patients who had coronary bypass using $T-PLS^{TM}\;and\;Bio-pump^{TM}$ (20 patients for each) from April 2003 to June 2005. All of the surgeries were operated on pump beating coronary artery bypass graft using cardiopulmonary extra-corporeal circulation. Risk factors before surgery and the condition during surgery and the results were compared. Result: There was no significant difference in age, gender ratio, and risk factors before surgery such as history of diabetes, hypertension, smoking, obstructive pulmonary disease, coronary infarction, and renal failure between the two groups. Surgery duration, hours of heart-lung machine operation, used shunt and grafted coronary branch were little different between the two groups. The two groups had a similar level of systolic arterial pressure, diastolic arterial pressure and mean arterial pressure, but pulse pressure was measured higher in the group with $T-PLS^{TM}\;(46{\pm}15\;mmHg\;in\;T-PLS^{TM}\;vs\;35{\pm}13\;mmHg\;in\;Bio-pump^{TM},\;p<0.05)$. The $T-PLS^{TM}$-operated patients tended to produce more urine volume during surgery, but the difference was not statistically significant $(9.7{\pm}3.9\;cc/min\;in\;T-PLS^{TM}\;vs\;8.9{\pm}3.6\;cc/min\;in\;Bio-pump^{TM},\;p=0.20)$. There was no significant difference in mean duration of respirator usage and 24-hour blood loss after surgery between the two groups. Plasma free Hb was measured lower in the group with $T-PLS^{TM}\;(24.5{\pm}21.7\;mg/dL\;in\;T-PLS^{TM}\;versus\;46.8{\pm}23.0mg/dL\;in\;Bio-pump^{TM},\;p<0.05)$. There was no significant difference in coronary infarction, arrhythmia, renal failure and morbidity rate of cerebrovascular disease. There was a case of death after surgery (death rate of 5%) in the group tested with $T-PLS^{TM}$, but the death rate was not statistically significant. Conclusion: Coronary bypass was operated with $T-PLS^{TM}$ (Pulsatile flow pump) using a heart-lung machine. There was no unexpected event caused by mechanical error during surgery, and the clinical process of the surgery was the same as the surgery for which $Bio-pump^{TM}$ was used. In addition, $T-PLS^{TM}$ used surgery was found to be less detrimental to blood corpuscles than the pulsatile flow has been known to be. Authors of this study could confirm the safety of $T-PLS^{TM}$.

Total Spinal Block and Cortical Epidural Block for Whiplash Syndrome and Reflex Sympathetic Dystrophy (Report of Four Cases) (전척수(全脊髓) 및 경막외차단(硬膜外遮斷)으로 편타성(鞭打性) 손상(損傷)의 통증치험(痛症治驗) (4례(例) 보고(報告)))

  • Park, Wook;Ok, See-Young;Song, Hoo-Bin
    • The Korean Journal of Pain
    • /
    • v.1 no.1
    • /
    • pp.106-119
    • /
    • 1988
  • For the relief of pain in 3 cases of whiplash syndromes (case I, II and IV) and in one of reflex sympathetic dystrophy (case III), we have carried out six intentional. total spinal blocks (TSB) which attempted two times in case I, three in case II and one in carte III whoso various symptoms were chronically unresponsive to the usual conservative treatments, and a time of cervical epidural and right suprascapular nerve block in case W whose acute symptom lasted 4 drys following the cervical injury (see fables from 1 to 9). During the 753, we have observed clinically the sequential charges of respiration, lid and pupil reflexes, body motion and consciousness. And checked the blood pressure, pulse rate and arterial Pco2. The effectiveness of those blocks has been assessed by using the Visual Analog Scale which is designed to measure the patient$\acute{s}$ subjective intensity of pain and also we have found out the sequelae following those blocks. The methods of the blocks were as the following: 1. Under the N.P.O. for 8~10 hours, the preparations of immediate cardiopulmonary resuscitation and premedication with atropine 0.5mg at thirty minutes before the TSB, it was performed by injecting the mixture of 2% mepivacaine 10 or 15ml and normal saline 10 or 5ml through No. 23 G. spinal needle into the subarachnoid space of $C_7-T_1$ interspinous region with fully flexed neck on the lateral posture. Immediately after the injection of the local anesthetic in the lateral position, the patient$\acute{s}$ were hasten to change Trendelenburg$\acute{s}$ position in order to act the drugs cephalad and to make easy controlled respiration with oxygen. 2. The cervical epidural block was done by injecting the mixture of 0.5% bupivacaine 4ml, normal saline 4ml and triamcinolone 15mg through No. 18 G. Tuohy needle into the epidural space on the same region and posture as the above without premedication.7he suprascapular nerve block was done by injecting of 0.5% bupivacaine 3ml only into the right suprascapular fossa on the sitting posture. The results were as the following: 1. The cessation of respiration was seen within 5 minutes following the subarachnoidal injection of the above 20ml mixture in 2 to 3 minutes and then soon the consciousness began to disappear. The loss of Lid and pupil reflexes noted between 5 to 10 minutes and the size of the dilated pupils was equal between 5 to 20 minutes, but the pupil of the dependent side on tile lateral position was dilated 1 to 3 minutes earlier than that of the independent. The patients had r=ever responded to any stimulations during the TSB except their heart funtion. 2. The recovery of the TSB was as the following, firstly the ankle and lower limb of the independent side began to move slightly with in 34 to 75 minutes after the injection and then that of the dependent Secondly the neck and upper limb moved 6 to 15 minutes later than the lower limb. Thirdly the self respiration began to appear between 40 to 80 minutes from the block. The lid and pupil reacted to touch and light respectively between 40 to 80 minutes but the pupil of the independent side responded earlier than that of the depends. Lastly the consciousness recovered completely between 80 to 125 minutes from the block. 3. In the cardiopulmonary function during the TSB, the blood pressure were stable except the 210/130 tory at the and block of case I. There were bradycardias between 65 to 85 minutes in case I and II but no arrythmia on the EKG. The level of the arterial Pco2 was maintained to 43~45 torr during the TSB. 4. The effectiveness of the above blocks was no pain(0%) in case IV, and light (10~20%) in case I and II but no improvement in case III. 5. The right arm weakness has been complicated as to be Injected accidently the "COLD" local anesthetic at the End block of case I.

  • PDF