• Title/Summary/Keyword: Arterial Characteristic

Search Result 61, Processing Time 0.031 seconds

Artery to Collecting System Communication after Abdominal Trauma (복부 외상 후 발생한 동맥-집뇨계 간 연결)

  • Lee, Chang Ug;Kwon, O Jung;Bang, Sung Hak;Choi, Nak Young;Lee, Chang Sub;Ahn, Seung Hyun
    • Journal of Trauma and Injury
    • /
    • v.19 no.2
    • /
    • pp.192-195
    • /
    • 2006
  • Degenerative vascular disease, previous arterial surgery, long-term ureteral stenting, pelvis surgery, and radiotheraphy are reported as causes of artery-to-collecting-system communication.. Artery-to-collecting-system- communication associated with blunt trauma is rare, but potentially fatal. The diagnosis is very difficult and requires a high degree of suspicion. We were able to make the diagnosis based on the characteristic finding of contrast-enhanced computed tomography (CT) obtained in the early phase, equivalent to the finding obtained in the corticomedullary phase of the kidney. We report a case of artery to collecting system communication due to blunt abdominal trauma following a fall, which was treated by embolization.

Improvement of a characteristic point detection algorithm of arterial pulse (동맥맥파의 특징점 검출 알고리즘 개선에 관한 연구)

  • Jeon, Young-Ju;Lee, Jeon;Kim, Jong-Yeol;Lee, Lark-Beom;Im, Jae-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1916-1917
    • /
    • 2007
  • Aortic AIx(augmentation index) has been used to measure aortic stiffness and evaluate ventricular load quantitatively. Algorithm for the detection of augmentation point gradually increases the differential order to detect inflection point rather than detects the distinctive point that appears after a specific time. Developed algorithm for AIx is proved to provide more accurate results than the ones developed by previous studies with the deviation from $-11.5{\pm}14.34$ points to $-3.75{\pm}1.26$ points. Results could provide the basis for the measurement of aortic stiffness using easily-measurable radial artery pulse waves, and could be extended to develop a system for early diagnosis of various vascular diseases.

  • PDF

Fibromuscular Dysplasia of the Distal Internal Carotid and Middle Cerebral Artery (원위 속목동맥과 중간대뇌동맥에 발생한 섬유근육형성이상)

  • Kim, Ju-Hyun;Lee, Jun
    • Journal of Yeungnam Medical Science
    • /
    • v.26 no.1
    • /
    • pp.78-83
    • /
    • 2009
  • Fibromuscular dysplasiais an uncommon condition of idiopathic, non-inflammatory and non-atherosclerotic disease of the musculature of arterial walls. The disease is rare, but it commonly affects young and middle aged women. Isolated intracranial cerebral fibromuscular dysplasia is extremely rare because cerebral fibromuscular dysplasia usually affects extracranial vessels. A 20-year-old woman was admitted with light hemiplegia and global aphasia. Brain MRI and MRA demonstrated acute left middle cerebral artery territory infarction with a multifocal stenosis and dilatation of the left middle cerebra artery and left internal carotid. The characteristic conventional cerebral angiographic findings demonstrated a typical string-of-beads appearance in the left distal internal carotid artery and proxiaml portion of the left middle cerebral artery, which suggested a medial type fibromuscular dysplasia. We report a case of isolated intracranial fibromuscular dysplasia with left middle cerebral artery territory infarction. Fibromuscular dysplasia should he considered as a stroke risk factors in children and young adults, especially in patients with no known cardiovascular risk factors.

  • PDF

Intravoxel Incoherent Motion Magnetic Resonance Imaging for Assessing Parotid Gland Tumors: Correlation and Comparison with Arterial Spin Labeling Imaging

  • Gao Ma;Xiao-Quan Xu;Liu-Ning Zhu;Jia-Suo Jiang;Guo-Yi Su;Hao Hu;Shou-Shan Bu;Fei-Yun Wu
    • Korean Journal of Radiology
    • /
    • v.22 no.2
    • /
    • pp.243-252
    • /
    • 2021
  • Objective: To compare and correlate the findings of intravoxel incoherent motion (IVIM) magnetic resonance (MR) imaging and arterial spin labeling (ASL) imaging in characterizing parotid gland tumors. Materials and Methods: We retrospectively reviewed 56 patients with parotid gland tumors evaluated by MR imaging. The true diffusion coefficient (D), pseudo-diffusion coefficient (D*), and fraction of perfusion (f) values of IVIM imaging and tumor-to-parotid gland signal intensity ratio (SIR) on ASL imaging were calculated. Spearman rank correlation coefficient, chi-squared, Mann-Whitney U, and Kruskal-Wallis tests with the post-hoc Dunn-Bonferroni method and receiver operating characteristic curve assessments were used for statistical analysis. Results: Malignant parotid gland tumors showed significantly lower D than benign tumors (p = 0.019). Within subgroup analyses, pleomorphic adenomas (PAs) showed significantly higher D than malignant tumors (MTs) and Warthin's tumors (WTs) (p < 0.001). The D* of WTs was significantly higher than that of PAs (p = 0.031). The f and SIR on ASL imaging of WTs were significantly higher than those of MTs and PAs (p < 0.05). Significantly positive correlation was found between SIR on ASL imaging and f (r = 0.446, p = 0.001). In comparison with f, SIR on ASL imaging showed a higher area under curve (0.853 vs. 0.891) in discriminating MTs from WTs, although the difference was not significant (p = 0.720). Conclusion: IVIM and ASL imaging could help differentiate parotid gland tumors. SIR on ASL imaging showed a significantly positive correlation with f. ASL imaging might hold potential to improve the ability to discriminate MTs from WTs.

A Case of Basilar Arterial Thrombosis in Ovarian Hyperstimulation Syndrome (난소 과자극증후군과 동반된 뇌바닥동맥 혈전증)

  • Park, Joon-Cheol;Lim, Su-Yeon;Bae, Jin-Gon;Kim, Jong-In;Rhee, Jeong-Ho
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.35 no.1
    • /
    • pp.83-88
    • /
    • 2008
  • Thromboembolic disease associated with assisted reproductive techniques is considered to be extremely rare but most serious complication. The reasons for this are thought to hypercoagulable state characteristic of OHSS due to high serum levels of estrogen, hemoconcentration and reduced circulating blood volume, but is still unclear. The risk is increased those with rare hypercoagulable conditions such as antiphospholipid antibody syndrome, protein C deficiency, protein S deficiency, antithrombin III deficiency, and those with a personal or family history of thromboembolic disease. The majority of thrombosis reported were venous site but arterial thrombosis mostly intracerebral was reported 5 cases in Korea so far. We present a case of basilar a. thrombosis at 11 days after hCG injection. The patient developed the right hemiparesis, and recovered after intraarterial thrombolysis and transluminal angioplasty. Protein S activity was decreased and vWF antigen was increased. Decreased protein S activity was also found in previous reported 4 cases, so we suggest screening test for protein S in OHSS patients.

The Usefulness of Initial Arterial Base Deficit in Trauma Patients (내원 초기에 측정한 외상환자의 동맥혈 염기결핍의 유용성)

  • Lee, Eun Hun;Choi, Jae Young;Choi, Young Cheol;Hwang, Seong Youn
    • Journal of Trauma and Injury
    • /
    • v.19 no.1
    • /
    • pp.67-73
    • /
    • 2006
  • Purpose: The arterial base deficit (BD) has proven to be useful in the evaluation and management of trauma patients. Indicators such as the Triage-Revised Trauma Score (t-RTS) and the systemic inflammatory response syndrome (SIRS) score have been used as triage tools for emergency trauma patients in Korea. The purpose of this study was to assess the usefulness of the initial BD in predicting injury severity and outcome in the trauma population. Methods: The medical records of 308 consecutive trauma patients admitted to the Emergency Center of Masan Samsung Hospital from January 2004 to December 2004 were carefully examined prospectively and retrospectively, and 291 patients were selected as subjects for this research. The SIRS score and the t-RTS were calculated based on the records from the emergency department, and the BD was calculated based on the arterial blood gas analysis obtained within 30 minutes of admission. The efficiency of the three indicators as triage tools was evaluated by using cross tabulations in two - by - two matrices and by using a receiver operating characteristic (ROC) curve analysis. Results: When the mortality was used as the outcome parameter, the sensitivity and the accuracy of the initial BD were higher than those of the SIRS score (p<0.05) and were same as those of the t-RTS. The areas under the ROC curves of the initial BD, the SIRS score, and the t-RTS were $0.740{\pm}0.087$, $0.696{\pm}0.082$, and $0.871{\pm}0.072$, respectively (95% confidence interval). When emergency operation and blood transfusion requirements were used as outcome parameters, the comparisons of the sensitivities and the accuracies of the initial BD and the other two indicators showed the same pattern as mentioned above. The areas under the ROC curves of the initial BD were 0.7~0.8 and were larger than those of the SIRS score (p<0.05). Conclusion: The ability of the initial BD to predict injury severity and outcome was similar to those of the t-RTS and the SIRS score. Therefore, the authors suggest that the initial BD may be used as an alternative to previous triage tools for trauma patients.

CT Scan Findings of Rabbit Brain Infection Model and Changes in Hounsfield Unit of Arterial Blood after Injecting Contrast Medium (토끼 뇌감염 모델의 CT 소견과 조영제 주입 후 동맥혈의 Hounsfield Unit의 변화)

  • Ha, Bon-Chul;Kwak, Byung-Kook;Jung, Ji-Sung
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.9
    • /
    • pp.270-279
    • /
    • 2012
  • This paper explores CT findings of a rabbit brain infection model injected with Escherichia coli and investigates the changes in Hounsfield unit (HU) of arterial blood over time. The brain infection model was produced by injecting E. coli $1{\times}10^7$ CFU/ml, 0.1 ml through the burr hole in the calvarium; 2~3 mm in depth from the dura mater, and contrast-enhanced CT, dynamic CT and arterial blood CT images were gained. It was found that various brain infections such as brain abscess, ventriculitis and meningitis. The CT image of brain abscess showed a typical pattern which the peripheral area was strongly contrast-enhanced while the center was weakly contrast-enhanced. The CT image of ventriculitis showed a strong contrast-enhancement along the lateral ventricle wall, and the CT image of meningitis showed a strong contrast-enhancement in the area between the telencephalon and the diencephalon. In dynamic CT images, the HU value of the infection core before injecting contrast medium was $31.01{\pm}3.55$. By 10 minutes after the injection, the value increased gradually to $40.36{\pm}3.76$. The HU value in the areas of the marginal rim where was hyper-enhanced showed $47.23{\pm}3.12$ before contrast injection, and it increased to $63.59{\pm}3.31$ about 45 seconds after the injection. In addition, the HU value of the normal brain tissue opposite to the E. coli. injected brain was $39.01{\pm}3.24$ before the injection, but after the contrast injection, the value increased to $49.01{\pm}4.29$ in about 30 seconds, and then it showed a gradual decline. In the arterial blood CT, the HU value before the contrast injection was $87.78{\pm}6.88$, and it increased dramatically between 10 to 30 seconds until it reached a maximum value of $749.13{\pm}98.48$. Then it fell sharply to $467.85{\pm}62.98$ between 30 seconds to 45 seconds and reached a plateau by 60 seconds. Later, the value showed a steady decrease and indicated $188.28{\pm}25.03$ at 20 minutes. Through this experiment, it was demonstrated that the brain infection model can be produced by injecting E. coli., and the characteristic of the infection model can be well observed with contrast-enhanced CT scan. The dynamic CT scan showed that the center of the infection was gradually contrast-enhanced, whereases the peripheral area was rapidly contrast-enhanced and then slowly decreased. As for arterial blood, it increased significantly between 10 seconds to 30 seconds after the contrast medium injection and decreased gradually after reaching a plateau.

Estimation of the Variation of Quantity in PWV in Accordance with the Changes of Position in Human (자세변화에 따른 PWV 변화량의 평가)

  • Jun, Suk-Hwan;Jeong, In-Cheol;Jung, Sang-O;Yoon, Hyung-Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.2
    • /
    • pp.129-134
    • /
    • 2009
  • The ideal method which measures a blood vessel of senility and degree of arteriosclerosis is to measure compliance of arterial and condition of blood circulation at the periphery. In these days vascular stiffness have been assessed by analyzing PTT (pulse transit time) from ECG and PPG. PTT is that between toe and finger each subject estimated through ECG and PPG signals. Two parameters, which are related to PWV, were tested with the time delay between the finger and toe. PWV is a variation of quantity which is associated with vascular stiffness. These researches which use PTT and PWV don't consider the blood vessel characteristic of an individual. In this current research, we have used with the blood vessel characteristic of an individual. That is an assessment of vascular stiffness using the variation of quantity in PWV with the changes of position in the subject. PWV variation increased as functions of the subject's age. The increase of the PWV variation parameters with age is attributed to the direct decrease of the blood vessel compliance with different position. The quantity of variation estimated by experimental results is that old age's (75.78${\pm}$7.75) case is 113.68% and young age's (26.47${\pm}$2.04) case is 85.69%. We proved and presented about estimation of vascular stiffness of possibility by this result.

A Basic Study on Analysis of Influencing factor of Bus Accidents in Bus Lane Section (버스전용차로 구간 유형별 버스사고영향요인 분석 기초연구)

  • Park, Jun-Tae;Kim, Hyun-Jin;Kim, Jung-Yeol;Jang, Il-Jun;Lim, Joon-Bum
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.153-160
    • /
    • 2012
  • Various social problems such as traffic congestion, car accidents and environmental problems(air pollution, noises etc.) have been happening in the Seoul metropolitan area that has the car oriented traffic system providing cars continuously. Along with this, the financial burden caused by current oil price anxiety made paradigm shift from caroriented to public transportation-oriented. Its typical example is an arterial branch bus system changing(bus lane through the center of main road) started in Seoul in July, 2004. But study on safety analysis of bus lane and characteristic of accidents are not sufficient enough to now. The bus lanes are expanded to provide roads for better traffic operation and accidents between buses and pedestrians or ordinary vehicles are considered main problems. This study divided each bus route of median bus lane(bus-only lane through the center of main roads) and bus lane at roadside by intersection and collected and analysed data about influence variables of bus accidents chosen in each section. We constructed a logistic model using collected data. As a result, bus lane at roadside are used by both buses and other kinds of vehicles differently from median bus lane and showed such characteristic in accident influence. Therefore access management to factors causing conflict and improvement of operation management are required. In case of median bus lane, the more buses moving general vehicle lane and traffic volume of section were, the more accidents happened. In case that stop line of center lane is not backward, view blocking of vehicles turning left caused accidents.

Compensation of the Error Rate for the Non-invasive Sphygmomanometer System Using a Tactile Sensor

  • Jeong, In-Cheol;Choi, Yoo-Nah;Yoon, Hyung-Ro
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.136-141
    • /
    • 2007
  • The Purpose Of This Paper Is To Use A Tactile Sensor To Compensate The Error Rate. Most Automated Sphygmomanometers Use The Oscillometric Method And Characteristic Ratio To Estimate Systolic And Diastolic Blood Pressure. However, Based On The Fact That Maximum Amplitude Of The Oscillometric Waveform And Characteristic Ratio Are Affected By Compliance Of The Aorta And Large Arteries, A Method To Measure The Artery Stiffness By Using A Tactile Sensor Was Chosen In Order To Integrate It With The Sphygmomanometer In The Future Instead Of Using Photoplethysmography. Since Tactile Sensors Have Very Weak Movements, Efforts Were Made To Maintain The Subject's Arm In A Fixed Position, And A 40hz Low Pass Filter Was Used To Eliminate Noise From The Power Source As Well As High Frequency Noise. An Analyzing Program Was Made To Get Time Delay Between The First And Second Peak Of The Averaged Digital Volume Pulse(${\Delta}t_{dvp}$), And The Subject's Height Was Divided By ${\Delta}t_{dvp}$ To Calculate The Stiffness Index Of The Arteries($Si_{dvp}$). Regression Equations Of Systolic And Diastolic Pressure Using $Si_{dvp}$ And Mean Arterial Pressure(Map) Were Computed From The Test Group (60 Subjects) Among A Total Of 121 Subjects(Age: $44.9{\pm}16.5$, Male: Female=40:81) And Were Tested In 61 Subjects To Compensate The Error Rate. Error Rates Considering All Subjects Were Systolic $4.62{\pm}9.39mmhg$, And Diastolic $14.40{\pm}9.62mmhg$, And Those In The Test Set Were $3.48{\pm}9.32mmhg,\;And\;14.34{\pm}9.67mmhg$ Each. Consequently, Error Rates Were Compensated Especially In Diastolic Pressure Using $Si_{dvp}$, Various Slopes From Digital Volume Pulse And Map To Systolic-$1.91{\pm}7.57mmhg$ And Diastolic $0.05{\pm}7.49mmhg$.