• 제목/요약/키워드: Array chip

검색결과 531건 처리시간 0.028초

Color Filter Array에 대한 고품질 영상보간기법 (High Quality Image Interpolation for Color Filter Arrays)

  • 이봉준;이철희
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(4)
    • /
    • pp.171-173
    • /
    • 2000
  • In this paper, we present a new interpolation method for the color filter away(CFA). In order to capture color images. typical input devices use a single chip CCD imaging sensor with color filter array. As a result, the single chip CCD does not provide sufficient color resolutions since it arranges different color filters sequentially on a single CCD, resulting in aliasing noise and loss of resolution. In order to reconstruct high quality color images, we propose to use the interpolation algorithm using high order B-splines. Experiments show promising results.

  • PDF

CNT 배열을 이용한 bio-sensor SoC 설계 (A bio-sensor SoC Platform Using Carbon Nanotube Sensor Arrays)

  • 정인영
    • 대한전자공학회논문지SD
    • /
    • 제45권12호
    • /
    • pp.8-14
    • /
    • 2008
  • 본 논문에서는 $8{\times}8$ CNT 센서 어레이를 CMOS 공정 후 처리를 통하여 센서회로가 제작된 CMOS 칩에 집적시켜 측정장비 없이도 자체적으로 감지결과를 출력할 수 있는 센서 칩의 기본적인 플랫폼을 설계 제작한 결과를 보고한다. 센서 소자로는 알루미늄 패드 사이에 연결된 CNT network을 사용하였으며 생화학적 반응에 의하여 전기전도도가 변화하는 것을 감지한다. 표준 CMOS 공정의 감지회로는 CNT network의 저항 값 변동에 의해 ring oscillator의 주파수가 변동하는 것을 감지하는 방식을 사용한다. 제작된 CMOS 센서 칩을 활용하여 이를 대표적인 생화학물질인 glutamate을 검출하는데 실험적으로 적용하여 농도에 따른 출력결과 값을 얻는데 성공한다. 본 연구를 통하여 본 센서 칩 플랫폼을 이용한 상용화의 가능성을 확인하며, 추가적으로 개발이 필요한 기술에 대해 파악한다.

이동 로보트 경로상의 장애물 검지를 위한 SRF (Sonic Range Finder) Array에 관한 연구 (A study on the SRF array to detect the obstacles of the mobile robot's path)

  • 윤영배;이상민;홍승홍
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.87-90
    • /
    • 1987
  • This paper gives the Sonic Range Finder(SRF) Array which detects the unknown obstacles on the mobile robot's path. This SRF Array gives mobile robot's circumstance information wider, processes and transfers them to the locomotion module to construct the modify path. In this system, 8 pairs of the 40 KHz ultrasonic sensors constitute the SRF Array, including a pair of reference sensors to correct the errors, 4051 analog multiplexer and demultiplexer swtch the sensor with time and 8031-on chip micro computer controls processes the data and communication the others.

  • PDF

SliM 이미지 프로세서 칩 설계 및 구현 (Design and implementation of the SliM image processor chip)

  • 옹수환;선우명훈
    • 전자공학회논문지A
    • /
    • 제33A권10호
    • /
    • pp.186-194
    • /
    • 1996
  • The SliM (sliding memory plane) array processor has been proposed to alleviate disadvantages of existing mesh-connected SIMD(single instruction stream- multiple data streams) array processors, such as the inter-PE(processing element) communication overhead, the data I/O overhead and complicated interconnections. This paper presents the deisgn and implementation of SliM image processor ASIC (application specific integrated circuit) chip consisting of mesh connected 5 X 5 PE. The PE architecture implemented here is quite different from the originally proposed PE. We have performed the front-end design, such as VHDL (VHSIC hardware description language)modeling, logic synthesis and simulation, and have doen the back-end design procedure. The SliM ASIC chip used the VTI 0.8$\mu$m standard cell library (v8r4.4) has 55,255 gates and twenty-five 128 X 9 bit SRAM modules. The chip has the 326.71 X 313.24mil$^{2}$ die size and is packed using the 144 pin MQFP. The chip operates perfectly at 25 MHz and gives 625 MIPS. For performance evaluation, we developed parallel algorithms and the performance results showed improvement compared with existing image processors.

  • PDF

Effect of Chip Spacing in a Multichip Module on the Heat Transfer for Paraffin Slurry Flow

  • Choi, Min-Goo;Cho, Keum-Nam
    • Journal of Mechanical Science and Technology
    • /
    • 제14권9호
    • /
    • pp.997-1004
    • /
    • 2000
  • The experiments were conducted by using water and paraffin slurry to investigate the effect of a chip spacing in the multichip module on the cooling characteristics from an in-line $4{\times}3$ array of discrete heat sources which were flush mounted on the top wall of a channel. The experimental parameters were chip spacing in a multichip module, heat flux of simulated VLSI chip, mass fraction of paraffin slurry, and channel Reynolds number. The removable heat flux at the same chip surface temperature decreased as the chip spacing decreased at the first and fourth rows. The local heat transfer coefficients for the paraffin slurry were larger than those for water, and the chip spacing on the local heat transfer coefficients for paraffin slurry influenced less than that for water. The enhancement factor for paraffin slurry showed the largest value at a mass fraction of 5% regardless of the chip spacing, and the enhancement factors increased as the chip spacing decreased. This means that the paraffin slurry is more effective than water for cooling of the highly integrated multichip module.

  • PDF

60 GHz 대역 능동 안테나 모듈 설계 (Active Antenna Module for 60 GHz Frequency Band)

  • 안세인;윤상원
    • 한국전자파학회논문지
    • /
    • 제30권6호
    • /
    • pp.518-521
    • /
    • 2019
  • 본 논문에서는 상용 트랜스미터 칩과 패치 어레이 안테나를 결합하여 60 GHz 대역에서 동작하는 능동 안테나 모듈을 설계, 제작하였다. 설계된 모듈은 안테나 PCB와 트랜스미터 칩이 장착된 송신 모듈 PCB가 결합되는 구조로 하였다. 주파수 제어신호 및 바이어스 제어신호는 아두이노 키트를 사용하여 인가하였으며, 기저대역의 I/Q 신호가 트랜스미터 칩으로 인가될 수 있도록 하였다. 송신 모듈의 출력은 단일 출력으로 안테나에 연결되므로 차동 출력을 내는 트랜스미터 칩의 출력을 링 하이브리드 발룬에 전달하고, 이를 초소형 상용 커넥터로 $2{\times}4$ 마이크로스트립 패치 어레이 안테나 PCB로 전달되도록 하였다. 최종 출력되는 밀리미터파 신호의 방사패턴 측정을 통하여 시뮬레이션 결과와 비교하는 방식으로 확인하였다. 제작된 능동 안테나 모듈의 방사패턴 측정 결과, 3 dB 빔폭과 null 포인트의 위치가 시뮬레이션 결과와 잘 일치함을 확인하였다.

Electrochemical Gene Detection Using Microelectrode Array on a DNA Chip

  • Park, Yong-Sung;Kwon, Young-Soo;Park, Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권4호
    • /
    • pp.145-148
    • /
    • 2004
  • In this study, a DNA chip with a microelectrode array was fabricated using microfabrication technology. Several probe DNAs consisting of mercaptohexyl moiety at their 5' end were immobilized on the gold electrodes by a DNA arrayer. Then target DNAs were hybridized and reacted with Hoechst 33258, which is a DNA minor groove binder and electrochemically active dye. Linear sweep voltammetry or cyclic voltammetry showed a difference between target DNA and control DNA in the anodic peak current values. It was derived from Hoechst 33258 and concentrated at the electrode surface through association with the formed hybrid. This suggested that this DNA chip could recognize the sequence specific genes.

미소전극어에이형 DNA칩을 이용한 유전자의 전기화학적 검출 (Electrochemical Detection of Genes Using Microeledtrode Array DNA Chip)

  • 최용성;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.2125-2127
    • /
    • 2004
  • In this paper, a DNA chip with a microelectrode array was fabricated using microfabrication technology. Several probe DNAs consisting of mercaptohexyl moiety at their 5 end were immobilized on the gold electrodes by DNA arrayer. Then target DNAs were hybridized and reacted with Hoechst 33258, which is a DNA minor groove binder and electrochemically active dye. Linear sweep voltammetry or cyclic voltammetry showed a difference between target DNA and control DNA in the anodic peak current values. It was derived from Hoechst 33258 concentrated at the electrode surface through association with formed hybrid. It suggested that this DNA chip could recognize the sequence specific genes.

  • PDF