• 제목/요약/키워드: Argon plasma

Search Result 323, Processing Time 0.026 seconds

A Study on the Characteristics of Silicon Nanopowders Produced by Transferred Type Arc Plasma Apparatus (이송식 아크플라즈마 장치에 의해 제조된 실리콘 나노분말의 특성에 대한 연구)

  • Kan, Woo-Seop;Park, Sang-Hee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_2
    • /
    • pp.909-917
    • /
    • 2021
  • This study was carried out experimentally on the production and properties of silicon nanopowders characteristics using a transferred type arc plasma apparatus. To investigate the properties of silicon nanopowder, the purity of argon gas(99.999%, 99.9%) and the partial pressure ratio of nitrogen gas(0~90%) were varied. The total pressure in chamber is 400Torr and the silicon chunk amount used as raw material is 300g. The power supplied to the cathode to generate arc plasma was 9~12kW/h, and the electrode was made of tungsten and graphite with a diameter of 13mm. The particle size, impurity elements and powder evaporation rate of the silicon powder were analyzed using the XRD, FE-SEM, TEM and electronic scale. According to the purity of argon gas, the silicon evaporation rate and the particle size were similar, and impurities were generated more in the case of 99.9% purity than 99.999%. When argon gas and nitrogen gas were mixed in the chamber, the silicon evaporation rate and particle size increased as the partial pressure ratio of nitrogen gas increased. In particular, when the partial pressure ratio of nitrogen gas was 80%, the silicon evaporation rate 80g/h, and the particle size was about 80~100nm.

SPS에 의한 $SiC-ZrB_2$ 복합체의 특성에 미치는 분위기 영향

  • Kim, Cheol-Ho;Sin, Yong-Deok;Ju, Jin-Yeong;Lee, Jeong-Hun;Park, Jin-Hyeong;Jo, Seong-Man;Kim, In-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.105-105
    • /
    • 2009
  • The composites were fabricated by adding 30, 35, 40, 45[vol.%] Zirconium Diboride(hereafter, $ZrB_2$) powders as a second phase to Silicon Carbide(hereafter, SiC) matrix. $SiC-ZrB_2$ composites were sintered by Spark Plasma Sintering(hereafter, SPS) in vacuum or argon gas atmosphere. The relative density of SiC+40[vol.%]$ZrB_2$ composites reveal high 99.57[%] in argon gas atmosphere and pressure 50MPa.

  • PDF

Ignition Characteristics of Aluminum Metal Powder Fuel with Thermal Plasma (플라즈마를 이용한 분말형 금속 연료 알루미늄의 점화 특성)

  • Lee, Sang-Hyup;Lim, Ji-Hwan;Yoon, Woong-Sup
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.737-744
    • /
    • 2011
  • The success of continuous aluminum powder combustion with steam plasma is different from hydrocarbon ignition source. Ignition characteristics of aluminum powder with high temperature thermal plasma is studied with oxidizer-free environment. Experiment with argon plasma has same temperature conditions at 4500 K and particle feeding condition for previous combustion test with steam plasma and swirl combustor. The temperature of the plasma was measured using Optical Emission Spectroscopy method. Ignition characteristics were analyzed by SEM image and EDS. Aluminum powder with plasma has rapid evaporation mechanism contrast to hydrocarbon ignition source. It enhances to aluminum powder effective ignition characteristics.

  • PDF

A Study on Effects of Parameters on Beads by Plasma Arc Welding for Zircaloy-4 (Zircaloy-4의 플라즈마 아크용접에서 용접변수가 비이드형상에 미치는 영향)

  • ;;;Kim, S. S.;Yang, M. S.
    • Journal of Welding and Joining
    • /
    • v.15 no.6
    • /
    • pp.57-65
    • /
    • 1997
  • A study was undertaken to determine the influence of welding variables such as shielding and plasma gases, torch standoff, travel speed and heat input, etc. on the quality of plasma arc welds in Zircaloy-4 sheet, 2mm thick. Effect of shielding gases and their flow rates on the mechanical properties of Zircaloy-4 welds by plasma arc welding were determined in terms of tensile, bardness and bend tests. The microstructure and fracture surface of Zircaloy-4 welds were investigated by optical and scanning electron microscopies. In addition, the causes of porosity and undercut in plasma arc welds of Zircaloy-4 were also investigated. Zircaloy-4 weld bead width and depth by helium shielding gas showed a wider and deeper than those by argon. It was found that Zircaloy-4 welds with shielding gas of helium did dxhibit a little smoother and uniform weld beads than those with shielding gas of argon. It was also found that the optimum gas flow rates for Zircaloy-4 welding were 0.45l/min for plasma gas with Ar and 4.5 - 6 l/min for shielding gas with He. In addition, there was no big difference in the microstructure and fracture surface of the weld metals made by either Ar shielding gas or He shielding gas.

  • PDF

아르곤4P준위 광방출 분석법(OES)을 이용한 플라즈마의 전자온도 및 준안정 밀도 측정

  • Lee, Yeong-Gwang;Lee, Min-Hyeong;Jeong, Jin-Uk
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2007.06a
    • /
    • pp.104-108
    • /
    • 2007
  • This paper reviews a simple model and spectroscopic method for extracting plasma electron temperature and argon metastable number density. The model is based on the availability of experimental relative emission intensities of only four argon lines that originate from 4p argon level. In this method, Maxwell-Boltzman distribution for EEDF is assumed and the calculation relies on the accuracy of the cross section. Therefore OES have to be compared with Langmuir probe to establish their practical validity.

  • PDF

A Study on the Operating Characteristics of Commercial Frequency Plasma Jet Torch (상용 주파수 (60Hz) Plasma Jet Torch의 동작특성에 관한 연구)

  • 전춘생;정재웅
    • 전기의세계
    • /
    • v.24 no.1
    • /
    • pp.75-85
    • /
    • 1975
  • In order to develop the commercial frequency (60Hz) plasma torch of small capacity for material cutting, welding and other industrial heating, the A.C plasma jet generator of non-transfered type is made domestically and the electrode configurations of plasma torch are composed of two kinds of electrodes W-C and W-Cu, combined by thermal emission and field emission electrode materials. In this paper, the characteristics of input power, thermal efficiency, electrode consumption, the flame and forms of arc voltage and arc current for A.C plasma torch are investigated in relation to such variables as arc current, argon flow and magnetic field intensity to obtain the basic design data necessary to A.C plasma jet generator. The result are as follows; (1)The input power, thermal efficiency and electrode consumption are influenced greatly by argon flow, magnetic field intensity and nozzle materials. (2)A.C arc voltage and current are non-symmetrial, involving D.C Component. Due to this current of D.C Component, transformer core is saturated and a large abnormal current flows into the primary winding coil. In order to prevent this abnormal current flow, a condenser must be connected in series to the main discharge circuit. (3)The stability and sharpness of jet flame are improved more in the torch of W-C electrode configuration than in the torch of W-Cu electrode configuration.

  • PDF

ANODE HEATING AND MELTING IN THE ARGON GTA

  • Terasaki, Hidenori;Tanaka, Manabu;Fujii, Hidetoshi;Ushio, Masao
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.746-751
    • /
    • 2002
  • In order to make clear the physical relation among the arc plasma, the anode heat transfer and the weld penetration, the results of experimental measurements of temperatures of arc plasma, the distributions of heat input and current on the anode and the weld penetration were presented The experimental results showed that the electron temperature above the anode and current and heat input density on the anode was dominated by the position of the cathode. Furthermore, it was showed that electron temperature of arc plasma was dominated by the cathode shape. These results were related with the results of the welded penetration measurements. As a result, it was showed that the electron temperature above the anode and current density distribution on the anode decided the heat input density distribution on the anode and that the heat input density on the anode remarkably dominated the size of the weld penetration in argon GTA welding process. Furthermore, it was suggested that the cathode played the important role in the determination of the weld penetration in argon GTA welding process.

  • PDF

Gastric Hemangioma Treated with Argon Plasma Coagulation in a Newborn Infant

  • Lee, Young Ah;Chun, Peter;Hwang, Eun Ha;Lee, Yeoun Joo;Kim, Chang Won;Park, Jae Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.20 no.2
    • /
    • pp.134-137
    • /
    • 2017
  • Gastric hemangioma in the neonatal period is a very rare cause of upper gastrointestinal bleeding. We present a case of hemangioma limited to the gastric cavity in a 10-day-old infant. A huge, erythematous mass with bleeding was observed on the lesser curvature side of the upper part of the stomach. Surgical resection was ruled out because the location of the lesion was too close to the gastroesophageal junction. Medical treatment with intravenous $H_2$ blockers, octreotide, packed red blood cell infusions, local epinephrine injection at the lesion site, application of hemoclip, and gel-form embolization of the left gastric artery did not significantly alter the transfusion requirement. Hemostasis was achieved with endoscopic argon plasma coagulation (APC). After two sessions of APC, complete removal of the lesion was achieved. APC was a simple, safe and effective tool for hemostasis and the ablation of gastric hemangioma without significant complications.

Study on the Effects of Ultrasonic Wave for the Effective Hydrogen Generation by Electrical Discharge Plasma Process

  • Park Jae-Youn;Cong Nghi-Vu;Han Sang-Bo;Kim Jong-Seok;Park Sang-Hyun;Lee Hyun-Woo;Lee Su-Jung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.6
    • /
    • pp.591-598
    • /
    • 2006
  • The research was tried to investigate the hydrogen generation from water by the pulsed power plasma process. Hydrogen was generated by way of the electrical pulse power discharge process with the ultrasonic wave. The yield on the hydrogen generation was also studied with and without operating the ultrasonic generator, in which the applied high voltage was varied from 10 kV to 15 kV. Nitrogen and argon gases were used as working gases. As the results, the generation yield using the pure nitrogen gas is better than argon and mixed gases such as argon and nitrogen. Hydrogen concentration are significantly increased when the ultrasonic generator was operated with the electrical discharge simultaneously. It is increased with increasing the applied ultrasonic level as well.

A Study on Adhesive Properties of Cellulose Triacetate Film by Argon Low Temperature Plasma Treatment (아르곤 저온 플라즈마 처리에 의한 CTA 필름의 접착성 연구)

  • Koo Kang;Park Young Mi
    • Textile Coloration and Finishing
    • /
    • v.16 no.5
    • /
    • pp.28-34
    • /
    • 2004
  • The polarizing film application exploits the unique physicochemical properties between PVA(Poly vinyl alcohol) film and CTA(Cellulose triacetate) film. However, hardly any research was aimed at improving the adhesion characteristics of the CTA film by radio frequency(RF) plasma treatment at argon(Ar) gaseous state. In this report, we deal with surface treatment technology for protective CTA film developed specifically for high adhesion applications. After Ar plasma, surface of the films is analyzed by atomic force microscopy(AFM), roughness parameter and peel strength. Furthermore, the wetting properties of the CTA film were studied by contact angle analysis. Results obtained for CTA films treated with a glow discharge showed that this technique is sensitive to newly created physical functions. The roughness and peel strength value increased with an increase in treatment time for initial treatment, but showed decreasing trend for continuous treatment time. The result of contact angle measurement refer that the hydrophilicity of surface was increased. AFM studies indicated that no considerable change of surface morphology occurred up to 3 minutes of treatment time, but a considerable uneven of surface structure resulted from treating time after 5 minutes.