• 제목/요약/키워드: Argon Control

Search Result 69, Processing Time 0.027 seconds

A STUDY ON THE SHAR BOND STRENGTH OF LIGHT-CURED GLASS IONOMER CEMENTS TO DENTIN ACCORDING TO CURING TIME INDUCED BY ARGON LASER (아르곤 레이저의 조사시간에 따른 광중합형 글래스 아이오노머 시멘트의 상아질에 대한 전단결합강도에 관한 연구)

  • Cho, Young-Lin;Hwang, Ho-Keel;Cho, Young-Gon;Oh, Haeng-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.267-277
    • /
    • 1997
  • The purpose of this study was to evaluate the shear bond strength of light-cured glass ionomer cements to dentin surface according to curing time induced by argon laser. In this study, 160 extracted human molars with sound crown were used. The dentin surface of these teeth were exposed with high speed diamond bur under water spray and polished with 120, 320, 400, 800, 1200 grits sand paper. 160 extracted human molars were randomly assigned into four groups (control, experimental 1, 2 & 3) with 40 teeth each. Control group used a visible light curing unit, XL 1000(3M Co., U.S.A) and experimental groups used argon laser($SPECTRUM^{TM}$). And then each group subdivided into two groups (A, B) according to filling materials. Subdivided A group used Fuji II LC(GC Co., Japan), B group used Vitremer(3M Co., U.S.A). The curing units and curing time of each group were as follows : Control group : visible light, 40 seconds Experimental group 1 Experimental group 2 Experimental group 3 : argon laser, 10 seconds : argon laser, 20 seconds : argon laser, 30 seconds The glass ionomer cements were bonded to dentin surface of each specimen. The specimens were stored in 100% relative humidity at 37"c for 7days. And then, the shear bond strength were measured by universal testing machine(Shimatzu Co. Japan) at crosshead speed of 5mm/min and 100kg in full scale and analyzed statistically. The following results were obtained : 1. Experimental group 2-A showed the highest shear bond strength with $9.87{\pm}1.24$ kgf and control group B showed the lowest shear bond strength with $4.08{\pm}0.78$ kgf(P<0.01). 2. The Fuji II LC showed higher shear bond strength with $9.49{\pm}1.24$ kgf than that of the Vitremer with $4.23{\pm}1.24$ kgf. There was significant difference between Fuji II LC and Vitremer(p<0.01). 3. There was no significant differences among experimental groups according to curing time induced by argon laser. 4. There was no significant differences between control group and experimental groups according to curing units.

  • PDF

Detection of Collagenase in Inflammatory Gingiva using Root planning and Argon Laser (치근면 활택술과 아르곤 레이저 사용에 따른 염증성 치은의 교원질 분해효소 검출 비교)

  • Lee, Chang-Gon;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.3
    • /
    • pp.577-594
    • /
    • 1999
  • The major cause of periodontal disease is microorganism in the dental plaque. Gingival sulcular fluid, which is exudate released from the tissue near crevicular epithelium is related with inflammation. The purpose of this study was to evaluate the argon laser efficiency between the clinical index and onset of collagenase of gingival sulcular fluid. Material divided 16 patients into 4 groups. The first control was without treatmemt. The second was with just treatment of argon laser, The third was treated by scaling and root planning and the fourth was treated with both scailing and root planning and argon laser. The level of periocheck test, the index of bleeding, and the depth of periodontal pocket were evaluated from for 128 teeth of 64 anterior teeth and 64 posterior teeth. The results were as follows ; 1. In the score of periocheck test, root planing group(group 3) was significantly reduced more than the group without treatment(group 1) and the argon laser treatment(group 2) for results of 3 days and 7 days. But root planing plus argon laser treatment(group 4) in the 7days after experiment, was significantly reduced than no treatment(group 1) and root planing treatment(group 3)(P<0.05), in the 3 days after experiment, was significantly reduced than root planing(group3)(P<0.05). The score of periocheck test to the root planning group(group 3) were significantly reduced between days1, day3 and day7(P<0.05). Root planning plus argon laser group(group 4) were significantly reduced to 1 or 7days and 3 or 7days(P<0.05). The argon laser group(group 2) didn't show any changes. 2. In the case of sulcus bleeding index, the root planning group(group 3) and root planning plus argon laser group(group 4) were reduced more than without treatment group(group 1)(P<0.05) and sulcus bleeding index in the root planning group(group 3) were reduced more than the argon laser group(group 2)(P<0.05). 3. There wasn't any changes of pocket depth between the control and the experiment group as with experiment periods also.

  • PDF

A STUDY ON THE PHYSICAL PROPERTIES OF RESTORATIVE MATERIALS FOR PHOTO-POLYMERIZATION OF ARGON LASER (아르곤 레이저를 이용한 광중합 수복재의 물리적 성질에 관한 연구)

  • Ju, Sang-Ho;Choi, Hyung-Jun;Kim, Seong-Oh;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.368-382
    • /
    • 1998
  • The purpose of this study is to evaluate and compare the results of argon laser for 5 seconds, argon laser for 10 seconds, and visible light for 40 seconds photo-polymerization in compressive strength, microhardness, curing depth, temperature rising during polymerization, and polymerization shrinkage. Hybrid type composite resin(Z-100) and compomer(Dyract) were used to be compared. The compressive strength was measured by an Instron(1mm/min cross head speed) in 60 specimens and the microhardness of the surface was expressed by Vickers Hardness Number(VHN) in 30 specimens. The curing depth was evaluated comparing the different values of upper and lower VHN according to irradiation time and thickness for the light source polymerization in 60 specimens. The temperature rising during photopolymerization was observed by the temperature change with thermocouple sensitizer beneath 40 specimens at the argon laser for 10 seconds and visible light 40 seconds irradiation. The polymerization shinkage was evaluated by calculating the decrease of % volume by using a dilatometer in 30 specimens. The results were as follows ; 1. In the case of compressive strength, the argon laser polymerization groups were higher than visible light group in Z-100 (p<0.05). In Dyract, the argon laser 5 seconds group did not show a significant difference with the visible light 40 seconds group. The argon laser 10 seconds group showed the markedly low value when compared with other groups (p<0.05) 2. In microhardness, Z-100 was better than Dyract when comparing by VHNs (p<0.05); however, there was not a significant difference between two materials in the visible light 40 seconds group and the argon laser 10 seconds group. 3. In the study of curing depth, Z-100 showed the consistent polymerization in argon laser irradiation because there was no difference in the VHN decrease according to the thickness change. Over the thickness control, the results did not show a significant difference between visible light and argon laser group in Z-100; however, in the case of Dyract, the visible light 40 seconds group was better than the argon laser groups(p<0.05). 4. There was a significant difference between the two materials in temperature rising during polymerization (p<0.05), but not a significant difference between irradiation times, 5. There was not a significant difference between the two materials in polymerization shrink age. The argon laser 5 seconds group was smaller than the other groups (p<0.05). It could be concluded that Z-100 polymerization was recommended to use the argon laser for reduction of the irradiation time while Dyract was recommended to use the visible light polymerization.

  • PDF

Numerical calculations of characteristics of Argon arc plasma using the control volume method (제어체적법에 의한 Ar 아크 플라즈마의 특성 계산)

  • Kim, Oe-Dong;Ko, Kwang-Cheol;Kang, Hyung-Boo
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1404-1406
    • /
    • 1995
  • In this paper, argon gas was used for numerical analysis of an arc in a cutting plasma torch driven by constant current. We established nozzle-constricting type torch domain and calculated steady state characteristics of argon arc plasma using the control volume method(CVM). For simplicity, we assumed that the flow field is laminar and the local thermodynamic equilibrium(LTE) prevails in all domain regions. We also neglected cathode-fall and anode-fall effects. Considering magnetic pinch effect and viscosity effect, we solved the momentum equation. Voltage drop in the arc column due to input current was calculated from the temperature field obtained by the energy balance equation.

  • PDF

The Effect of Argon Laser on Periodontal Disease (치주질환에 대한 Argon 레이저의 효과)

  • Ahn, Hyung-Joon;Ryu, Ji-Won;Kim, Jae-Hong;Kim, Chong-Youl
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.2
    • /
    • pp.277-285
    • /
    • 2005
  • The purpose of this study was to evaluate photothermal effect of laser, which eliminates and reduces bacteria causing periodontal disease, on treatment of periodontal disease. This study included subjects with moderate periodontitis who visited the Department of Oral Medicine, College of dentistry, Yonsei University. The subjects were divided into experimental group, where Argon laser treatment was used, and control group, where conventional subgingival curettage was used. Gingival fluids from each subject were collected prior and after 1 week of the treatment, and changes in number of bacterial colonies cultured from aerobic as well as anaerobic bacteria responsible for the periodontal disease, and changes in clinical indices related to the periodontal disease, such as plaque index, gingival index, sulcus bleeding index, were analysed. As a result, the number of bacterial colonies of aerobic and anaerobic bacteria reduced after 1 week of the treatment in both groups, especially the bacterial colonies of anaerobic bacteria which showed statistically significant reduction(p<0.1). However, there was no significant difference between the experimental group and the control group. Clinical indices including plaque index, gingival index, sulcus bleeding index were reduced after 1 week of the treatment in both groups. In the experimental group, gingival index(p<0.1) and sulcus bleeding index(p<0.01) showed significant reduction, and, in the control group, sulcus bleeding index(p<0.01) showed significant reduction. However, there were no significant differences in each indices between the two groups. The above results suggest that Argon laser could be used as a substitute of conventional subgingival curettage, or in combination with subgingival curettage which would increase the effect of the treatment. Although the possibility of clinical application of Argon laser was observed in this study, more randomized-controlled research, including acquirement of sufficient samples as well as long-termed follow up, would be necessary before clinically effective application of Argon laser.

TCP Accelerator for DVB-RCS SATCOM Dynamic Bandwidth Environment with HAIPE

  • Kronewitter, F. Dell;Ryu, Bo;Zhang, Zhensheng;Ma, Liangping
    • Journal of Communications and Networks
    • /
    • v.13 no.5
    • /
    • pp.518-524
    • /
    • 2011
  • A high assurance IP encryption (HAIPE) compliant protocol accelerator is proposed for military networks consisting of red (or classified) networks and black (or unclassified) networks. The boundary between red and black sides is assumed to be protected via a HAIPE device. However, the IP layer encryption introduces challenges for bandwidth on demand satellite communication. The problems experienced by transmission control protocol (TCP) over satellites are well understood: While standard modems (on the black side) employ TCP performance enhancing proxy (PEP) which has been shown to work well, the HAIPE encryption of TCP headers renders the onboard modem's PEP ineffective. This is attributed to the fact that under the bandwidth-on-demand environment, PEP must use traditional TCP mechanisms such as slow start to probe for the available bandwidth of the link (which eliminates the usefulness of the PEP). Most implementations recommend disabling the PEP when a HAIPE device is used. In this paper, we propose a novel solution, namely broadband HAIPE-embeddable satellite communications terminal (BHeST), which utilizes dynamic network performance enhancement algorithms for high latency bandwidth-on-demand satellite links protected by HAIPE. By moving the PEP into the red network and exploiting the explicit congestion notification bypass mechanism allowed by the latest HAIPE standard, we have been able to regain PEP's desired network enhancement that was lost due to HAIPE encryption (even though the idea of deploying PEP at the modem side is not new). Our BHeST solution employs direct video broadcast-return channel service (DVB-RCS), an open standard as a means of providing bandwidth-on-demand satellite links. Another issue we address is the estimation of current satellite bandwidth allocated to a remote terminal which is not available in DVBRCS. Simulation results show that the improvement of our solution over FIX PEP is significant and could reach up to 100%. The improvement over the original TCP is even more (up to 500% for certain configurations).

Inclusions and Mechanical Properties of TMCP Steel under Different RH Process Conditions (RH 공정 조건이 다른 TMCP강의 개재물 및 기계적 특성)

  • Yung-Kug Kwon;Byoung-Chul Choi;Gum-Hwa Lee;Ki-Woo Nam
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.1
    • /
    • pp.87-94
    • /
    • 2023
  • TMCP(Thermo Mechanical Control Process) steel was continuously cast (CC) by varying the argon gas flow rate and vacuum time in the Ruhrstahl Heraeus (RH) refining process. Using the CC specimens, the distribution of the inclusions and the mechanical properties were evaluated. A lot of oxides and Al-O type inclusions were observed. The average Vickers hardness did not show a constant, but showed dispersion in a certain range. The shape and scale parameters of the CC specimen with an argon gas flow rate of 160Nm3 and a vacuum time of 12 minutes was the best. Mechanical properties (tensile strength, yield strength and elongation) were consistent with the Weibull probability distribution analysis results. The impact resistance was the best for CC specimens with an argon flow rate of 140 Nm3 and a vacuum time of 12 minutes. Although the inclusions and mechanical properties of the CC specimens were evaluated according to the argon gas flow rate and vacuum time, these values were no significant difference.

AN IN VITRO STUDY OF THE THERAPEUTIC EFFECT OF ARGON LASER IRRADIATION ON HYPERSENSITIVE ROOTS (과민성치근에 대한 Argon laser조사의 치료효과에 관한 실험적 연구)

  • Chang, Kap-Sung;Kim, Byung-Ok;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.3
    • /
    • pp.668-678
    • /
    • 1995
  • In order to evaluate the therapeutic effect of argon laser irradiation on hypersensitive root, 60 mandibular premolars that had been extracted due to periodontal disease were treated by thorough scaling, root planing and root conditioning with tetracycline HCI(100mg/ml, 5 min.) for induction of hypersensitive root. Within middle one third of root mesial surface(30) or distal surface(30) was randomly irradiated by 0.5W-, 0.75W- and 1.0W-power for 2 minutes argon laser(HGM Inc., USA) with or without topical application of 1.23% acidulated phosphate fluoride gel(Pascal, USA). After all teeth were maintained in 2% methylene blue solution for 48 hours and cross-sectioned through irradiated surface of dried roots, methylene blue stained area was compared between irradiated side and nonirradiated side. Following results were obtained : 1. Methylene blue stained area was significantly less in the laser irradiated group than control group(p<0.05). 2. There was no significant difference in methylene blue stained area between 0.5W-power and 0.75W-power group(p>0.1) and between 0.75W-power and 1.0W-power group(p>0.1), but there was significant difference between 0.5W-power and 1.0W-power group(p<0.05). 3. There was no significant difference in methylene blue stained area between two groups with and without topical application of 0.12% acidulated phosphate fluoride gel(p>0.1). The results suggest that argon laser irradiation on hypersensitive root may reduce the hypersensitivity by obstruction of dentinal tubules.

  • PDF

The Effects of the Argon Laser Irradiation on the Root Surface : A Scanning Electronic Microscopic Study (아르곤 레이저 조사시 치근면 변화에 관한 주사 전자 현미경적 연구)

  • Eun, Hee-Jong;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.4
    • /
    • pp.861-872
    • /
    • 1999
  • Since pathologic changes of exposed root surface inhibit cell attachment and new attachment of connective tissue have been made, many efforts were apply to change the exposed root surface condition. Scaling and root planing can not remove the endotoxin completely and forms the smear layer which prohibits the new attachment of connective tissue. Therefore, many kinds of chemicals were used for controlling the pathologic change of the root surface. The purposes of this study was to compare and observe the changes of the exposed root surface treated by scaling and root planning, Tetracycline HCl and Argon Laser. After the scaling and root planning of ten extracted premolars, the differences & the root surface among groups were observed under SEM. Control group showed smear layer and irregular amorphous surface. The dentinal tubule was not exposed. The debris and scale like texture were also observed. Tetracycline HCl treated group showed relatively smooth surface and the collagen fiber was observed in the dentinal tubule. Argon Laser treated group showed the most effective results under the conditions of 0.8 to 1.0w irradiation for 0.5 to 1.0 sec with pulse wave. The results of this study showed that the root surface change was associated with the intensity and the duration of Argon Laser irradiation. Further investigation for the surface change with the Argon Laser irradiation is recommended for understanding of clinical effect.

  • PDF

Hardness and Microstructures of Ti-Zr-(Cu) based Alloys for Dental Castings (치과주조용 Ti-Zr-(Cu)계 합금의 경도 및 미세조직)

  • Joo, Kyu-Ji
    • Journal of Technologic Dentistry
    • /
    • v.27 no.1
    • /
    • pp.65-71
    • /
    • 2005
  • Experimental Ti-13%Zr and Ti-13%Zr-5%Cu alloys were made in an argon-arc melting furnace. The grade 2 CP Ti was used to control. The alloys were cast into phosphate bonded $SiO_2$ investment molds using an argon-arc casting machine, and The hardness and microstructures of the castings were investigated in order to reveal their possible use for new dental casting materials and to collect useful data for alloy design. The hardness of the Ti-13%Zr-5%Cu alloy(379Hv) became higher than that of Ti-13%Zr(317Hv) alloy, and the hardness of this alloys became higher than that of CP Ti(247Hv). Increasing in the hardness of the Ti-13%Zr-5%Cu alloy was considered to be solid solution hardening as the Ti-Zr system shows a completely solid solution for both high temperature $\beta$phase and low temperature $\alpha$ phase and also the inclusion of the eutectoid structure($\alpha Ti+Ti_{2}Cu$). No martensitic structures are observed in the specimen made of CP Ti, but Ti-13%Zr and Ti-13%Zr-5%Cu alloys show a kind of martensitic structure. Ti-13%Zr-5%Cu shows the finest microstructure. From these results, it was concluded that new alloys for dental casting materials should be designed as Ti-Zr-Cu based alloys.

  • PDF