• Title/Summary/Keyword: Area standards

Search Result 1,561, Processing Time 0.034 seconds

A Study on the Actual Conditions of Maintenance for Service Facilities in Office Buildings (사무소용 건물의 설비유지관리 실태에 관한 조사연구)

  • Sohn Jang-Yeul;Lee Seung-Eon
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.1
    • /
    • pp.12-20
    • /
    • 1985
  • This paper aims to present the basic data to establish resonable building maintenance standards by investigating and analyzing the actual conditions of maintenance for service facilities and the problems due to the situation. The subject buildings of investigation are 10 stories and above off ice buildings in Seoul. The results obtained from this study are as follows. 1. The equipment service life related to air-conditioning system is known as around 9years in case of breakdown maintenance and around 13 years in case of preventive maintenance. 2. The total mechanical room area against the total floor area is $4.40\%$, and the ratio of air-conditioning room area is $1.78\%$ on an average.

  • PDF

Comparison of National Standards for Blast Furnace Slag and Fly Ash between Korea and China (한국과 중국간의 고로슬래그 미분말 및 플라이 애시의 품질 규정 비교)

  • Hu, Yun-Yao;Lim, Gun-Su;kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.63-64
    • /
    • 2022
  • In this study, the quality of mineral admixture, Comparison of blast-furnace slag(BS) and fly ash(FA)in Korea and China. In the case of BS, Korea is mainly classified into 1 type to 4 types according to the specific surface area, whereas China is classified into S105, 95, and 75 according to the activity index of 28 days of age. In the case of FA, Korea is like BS, is mainly classified into types 1 to 4 according to specific surface area, whereas China is classified into F, C (class F, class C) by ingredients and class I, II, and III according to powder and ignition loss.

  • PDF

A Study on the Achievement Criteria of Robot Computing Curriculum for Elementary School (초등학교 로봇컴퓨팅교육을 위한 교육내용체계의 성취기준에 관한 연구)

  • Kim, Chul
    • Journal of The Korean Association of Information Education
    • /
    • v.21 no.1
    • /
    • pp.97-104
    • /
    • 2017
  • This paper evaluates the appropriateness of the proposed robot education curriculum to consider conceptual understanding and learning activities model considering the curriculum and achievement criteria in order to make it easier to apply for a course in robot area. The professors of dept. of computer education at national universities of education reviewed the importance of education contents system and appropriateness of education period. Based on the results of the review, the conceptual elements and achievement standards of each sub-area were revised and supplemented, and then evaluated in three stages. Finally, the educational elements of the concept factors and achievement criteria were agreed upon. The proposed robotic computing education information systems and the achievement standards for schools in the area, as well as to match the grade level of the students without distinction variety of robots will be able to take advantage of computing education activities to reorganize the robot computing courses.

Research about room air quality of department store underground parking lot (백화점 지하 주차장의 실내 공기질에 관한 연구)

  • Kim Ki-Tae;Yang Sung-Su;Son Bu-Soon;Jeon Young-Taek;Jang Bong-Ki;Lee Jong-Dae
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.1 s.59
    • /
    • pp.44-51
    • /
    • 2006
  • This study was conducted to investigate air quality in the underground parking lot of department store. Sampling sites were selected to the three sites in one department store. Measuring instrument started from November 3rd, 2005 to November 9, 2005. Target air quality parameters include a number of criteria pollutants such as NOx, $O_3$. The purpose of this study was to find out the present condition of indoor air quality in underground parking space of department store. Through the field measurement, the current situation and the behavior of contaminants were investigated and then was compared with the advice standards. The result of this study was as follows; The Average density of NOx gas and $O_3$ gas was maintained below the indoor air advice standards. The Average density of NOx gas and $O_3$ gas was highly measured during the weekend than during the week day. Average density of NOx gas and $O_3$ gas was highly measured at daytime than that of afternoon. Average density of NOx gas was highly measured in the center area than the other area. Average density of $O_3$ gas was highly measured at the entrance than the other area. NOx gas concentration was maintained below 0.3ppm, an average for 1 hours, as defined in the parking space law. $O_3$ gas concentration was maintained below 0.08ppm, an average for 1 hours, as defined in the parking space law.

A study of bioindicator selection for long-term ecological monitoring

  • Han, Yong-Gu;Kwon, Ohseok;Cho, Youngho
    • Journal of Ecology and Environment
    • /
    • v.38 no.1
    • /
    • pp.119-122
    • /
    • 2015
  • It is very useful and important to see the status and change of necessary parts in a short period through selecting and observing the bioindicator continually to forecast and prepare the future. Especially, living things are so closely related to the environment that the indicator between the environment and living things shows close interrelationship. Also, the indicator related to environment provides information about representative or decisive environmental phenomenon and is used to simplify complicated facts. Considering wide range of background and application including various indicators such as the change-, destruction-, pollution-, and restoration of habitats, climate change, and species diversity, the closest category includes "environmental indicator," "ecological indicator," and "biodiversity indicator." The selection and use of bioindicator is complicated and difficult. The necessary conditions for the indicator selection are flexible and greatly depend on the goals of investigation such as the indicator for biological diversity investigation of specific area, the indicator for habitat destruction, the indicator for climate change, and the indicator for polluted area. It should meet many various conditions to select a good indicator. In this study, eleven selection standards are established based on domestic and overseas studies on bioindicator selection: species with clear classification and ecology, species distributed in geographically widespread area, species that show clear habitat characteristics, species that can provide early warning for a change, species that are easy and economically benefited for the investigation, species that have many independent individual groups and that is not greatly affected by the size of individual groups, species that is thought to represent the response of other species, species that represent the ecology change caused by the pressure of human influence, species for which researches on climate change have been done, species that is easy to observe, appears for a long time and forms a group with many individuals, and species that are important socially, economically, and culturally.

Analysis of Relationship between O3, NO, and NO2 in Riyadh, Saudi Arabia

  • Shareef, Mohammed Mujtaba;Husain, Tahir;Alharbi, Bader
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.1
    • /
    • pp.17-29
    • /
    • 2018
  • For the first time in the city of Riyadh, the formation of $O_3$ and its relationship with NO and $NO_2$ ($NO_x$) was investigated. Throughout the summer $O_3$, NO, and $NO_2$ were collected from three locations: residential, industrial, and rural areas. During the sampling period $O_3$ concentrations exceeded 1-hour local standards a few times yet remained consistent with the standards most of the time. The $O_3$ concentrations were observed highest in the rural location and lowest in the industrial area. The diurnal variation of NO followed a double peak: one in the morning and the other in the evening, representing the traffic pattern. Early morning NO peaks were observed in the rural location, which were attributed to the movement of NO from other locations. The $O_3$ concentrations depicted typical pattern, increasing after sunrise and reaching its maximum during midday. The highest $O_3$ concentrations were observed in the rural location followed by the residential and industrial. $NO_2$ photolysis rates were 3-4 times higher compared to other similar investigations, potentially due to intense solar radiation. A strong negative correlation was observed between $NO_x$ and $O_3$ values in the industrial location indicating photochemical activities around the industrial area were higher, likely due to additional $NO_x$ emissions from industries. Regression analysis of $NO_x$ and OX ($O_3+NO_2$) indicated that in residential and industrial locations at nighttime there were large $NO_x$ independent regional contributions which is attributed to VOCs. The Weekend Effect was observed in the city potentially due to the production of the OH radical and subsequent reactions with VOCs implying that the area is VOC-sensitive.

Perception of environment-friendly foods and satisfaction with school meals among students, their parents, and nutrition teachers at elementary schools in the Jindo area, Jeonnam (전라남도 진도 인근지역의 초등학생, 학부모, 영양(교)사의 친환경식품에 대한 인식과 학교급식 만족도)

  • Jung, Moon-Hee;Chang, Moon-Jeong;Kim, Sun-Hee
    • Journal of Nutrition and Health
    • /
    • v.46 no.4
    • /
    • pp.369-381
    • /
    • 2013
  • The aim of this study was to investigate the perception of students, their parents, and nutrition teachers regarding environment-friendly foods (EFF) and the satisfaction with school meals at elementary schools. Questionnaires were sent to nutrition teachers at five elementary schools located in the Jindo area, Jeonnam province, and were distributed to students and their parents. A total of 351 questionnaires from students and 334 from parents were collected from March to April, 2013. In addition, 43 nutrition teachers/dietitians working at elementary schools in the Jindo area responded to questionnaires. Nutrition teachers primarily recognized the classification and certification standards of EFF, and verified the certification mark of EFF when they purchased foods. However, 13.4% of students and 38.6% of parents replied as 'know well' regarding the classification and certification standards of EFF and they verified the mark of EFF less often than the nutrition teachers (p<0.001). Most of the nutrition teachers and parents indicated 'safety' as the main advantage of EFF. The students and parents were satisfied with EFF at home and school meals because of the safety and favorable effect on health. The results showed that EFF compromised 20~40% of monthly food costs for 51.1% of nutrition teachers. The overall score for satisfaction with school meals for students was 3.88 based on a 5-point Likert scale; however, that of the parents was 3.72. The nutrition teachers realized that the parents were more interested in EFF and satisfied with EFF than the students. The major barriers to using EFF in school meals were 'lack of information about EFF' and 'unstable supply.' Therefore, the above results suggested that there should be improvement in the supply of EFF to include more EFF in school meals and efforts should be made to provide students and parents with more information for understanding EFF.

Rainfall Harvesting as an Alternative Water Supply in Water Stressed Communities in Aguata-Awka Area of Southeastern Nigeria

  • Okpoko, Ephraim;Egboka, Boniface;Anike, Luke;Okoro, Elizabeth
    • Environmental Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.95-101
    • /
    • 2013
  • Alternative sources of water are sought in some water stressed communities in the study area. The study focuses on the Aguata-Awka area of southeastern Nigeria. Aquifers occur at great depths, and surface waters may be far from homesteads. The scarcity of water has necessitated the people to adopt various local technologies for harvesting rainfall. The local technology includes collecting rainwater from roofs and channeling the water into large underground tanks, shallow wells and surface reservoirs. Large concrete tanks of $6m{\times}6m{\times}4m$ dimensions are often built underground and can store $144m^3$ of water. Surface reservoirs built on 4 m concrete pillar supports having dimensions of $10m{\times}10m{\times}4m$ and have a storage capacity of $400m^3$. Water samples were collected at 3 different locations of Agulu, Ekwulobia, and Awka and were analyzed for their physical, chemical, and bacteriological parameters. Results indicate a range of values for pH, 5.9 to 7.1; turbidity, 0.9 to 2.7; total dissolved solids, 80 to 170 mg/L; total hardness, 4.5 to 6.4 mg/L; magnesium, 1.2 to 1.4 mg/L; bicarbonate, 19.4 to 83.6 mg/L; and sulfate, 3.6 to 6.4 mg/L. Bacteriological analysis results were negative for fecal and total coliform counts. All parameters, with the exception of pH where aluminum and galvanized iron roofs are used for collection, fall within the recommended guidelines for drinking water quality of the World Health Organization, and the Standard Organization of Nigeria, new Nigerian standards for drinking water quality. Magnesium is above the maximum permitted level for consumer acceptability of the Nigerian standards for drinking water quality. The water can be classified as fresh moderately hard and soft. The water can be described as a calcium and bicarbonate type.

A Study on Developing the Optimal Sizing System for Ready-to-wear - Based on Elementary School Girls - (기성복의 최적 사이즈 시스템 개발을 위한 연구 - 학령기 여아를 중심으로 -)

  • Kim Ran-do;Lee Sang-youl;Kim Seon-young;Nam Yun-ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.8 s.145
    • /
    • pp.1102-1113
    • /
    • 2005
  • The propose of this study is to develop the optimal sizing system of ready-to-wear f3r elementary school girls using a newly invented statistical technique. The body measurements was classified by the method that equalizes the distribution of the subjects using the probability density function, to theoretically systemize a method to determine a size range of ready-to-wear for elementary school girls between 6 to 12 years old. The statistical method were 1) The total of 11 height groups, which size interval from one another is 6 cm that is an average height gap between each age. 2) In order to determine an approximate figure (m ${\times}$ n) to establish the appropriate sizes far each height group that fit to the combinations of bust and hip girth, which based on their means and standard deviations on the probability density curve to produce the standard normal distribution. 3) m and n were aligned by 4cm -the grading increments used for patterns making- and determined the size ranges by confirming the approximate figures of m and n. 4) The representative values were determined by an area ratio calculated by dividing the area determined from the range of bust and hip girth with the representative value. Considering the characteristics of subjects' distribution, the area ratios was used. 5) Weight was calculated by seeking a growth exponent for each age and multiplying it by the number of girls that fit to each size range. As sections that show the highest weight are more likely sought by the consumers, these sections were determined as the optimal size standards. 6) This optimal sizing system consists of sizes determined by the optimal size standards and its sizes are marked with height, bust and hip girth.

An Institutional Improving Standards for Water Reclamation/Reuse(WRR) System Establishment to Buildings (건축물의 중수도 설치기준에 대한 제도적 개선방안)

  • Kong, Young Hyo
    • KIEAE Journal
    • /
    • v.6 no.3
    • /
    • pp.43-48
    • /
    • 2006
  • This paper aims to suggest ways of institutionally improving standards that must be applied when installing Water Reclamation/Reuse (WRR) system based on efficiency analysis. Currently, the standard for WRR system establishment requires that the system should treat more than 10% of used water in the building of over $60,000m^2$ in total area of all floors, but our research has found that it would be more effective to change the standard to $150-m^3-per-day$ reclaimed water or the total area of all floors of $30,000m^2$ ($50,000m^2$ in the case of an office building). In other words, what this paper suggests is not a one-size-fits-all standard based on the total area of all floors, but a reasonable and flexible standard that takes into account efficiency and a unit water usage according to a building's purpose. Furthermore, this paper recommends a new WRR standard that can be applied to large-scale land development for housinglots, like the New Town. The recommendation is based on the economic analysis that the WRR system will ensure efficiency only if the amount of reclaimed water is over 4,000 tons per day, which corresponds to 4 millions square meters of housinglots. Regarding the size of the established facility, this paper suggests changing the standard, which is now set at over 10% of water usage, to what is relative to the total amount of use of reclaimed water in order to ensure efficiency and promote use of reclaimed water. In addition, this paper proposes that governmental support should be offered not only to facility owners, who are recipients at present, but also to facility builders. By doing so, those who donate a facility to the government, central or local, after building it, can be provided with substantial aid. Therefore, the application of the institutional improvement suggested in this paper is expected to create environment-friendly living conditions and boost the quality of life by encouraging people to secure water resources efficiently in buildings, and in a wider range, in cities.