• Title/Summary/Keyword: Area standards

Search Result 1,551, Processing Time 0.04 seconds

Analysis of Fish Guild Compositions and Total Mercury Contents of Fish Tissues in Analysis in Mangyeong River. (만경강 중.상류의 어류 길드특성 및 어류 조직내 수은 함량 분석)

  • Park, Hyang-Mi;Lee, Eui-Haeng;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.2
    • /
    • pp.172-182
    • /
    • 2009
  • This study was to analyze characteristics based on tolerance and trophic guilds and to determine the level of total mercury in tissues of sentinel species, Zacco platypus at 3 sampling sites of the Mangyeong River in 2007. Total sampled fishes were 26 species and the most dominant species was Zacco temminckii (47%). Fish community analysis was resulted that eveness index and diversity index showed low value at S1. However, diversity index and richness index at other sites showed high. According to various guilds analysis, relative abundance of sensitive species was 70% and 42% at S1 and S2, respectively. While sensitive species were decreased (1%) and tolerant species were increased (60%) at S3. It was mainly carried to the impacts of wastewater treatment plants near the location. Relative abundance of insectivore species was decreased from up (S1) to midstream area (S3). In addition, chemical water quality, based on analyses of BOD, COD, TP, TN, EC, MPN and SS concentration showed similar trends. Qualitative Habitat Evaluation Index (QHEI) was averaged 164, judged as "good" habitat condition. Average concentrations of total [Hg] was 146.9 ${\mu}g$ $kg^{-1}$. In the muscles of total [Hg] was the highest, and then followed by kidney, vertebrae, liver, and gills. According to FDA standards (500 ${\mu}g$ $kg^{-1}$) of Korea, total [Hg] has not affected to the individual fish health.

Hygienic quality of eggs in the department food stores in the Incheon Metropolitan area (인천지역 백화점 유통 계란의 위생적 품질상태)

  • 이성모;김경호;이정구;박은정;이승환;홍종해
    • Journal of Food Hygiene and Safety
    • /
    • v.17 no.3
    • /
    • pp.129-136
    • /
    • 2002
  • This study was conducted to Provide basic information Promoting egg qualify improvement and hygienic control by grasping of present market egg distribution system and hygienic quality. The eggs of 57 brands collected from the department food stores in Incheon Metropolitan City were examined. Eggs were kept in room temperature in all the market and 70.2% of the brands were marked the expiration date indicating that eggs would be available over 28 days after being laid. Fifty-four % of the market eggs was classified as a special or functional egg. Expiration date and date of laying were common labelling items in all brands. These items were labelled in trade mark sheet or eggs tray. Only 66.6% of the brands had the mark about net quantity of contents. The inspection about the exterior and contents of eggs has results as follows: eggshell contamination of feces and feather-9.5%, abnormal and broken eggshell -3.9%, blood and meat spots in contents -14.7% and watery whites -1.8%. Average of Haugh Unit(HU) was 56.1 and below HU 31 were 18 of 285 eggs(6.3%), in addition, more than one egg detected in 12 brands(21.1%) among 57 brands have inferior quality. Salmonella enteritidis from eggshell and antibodies directed from S. enteritidis in the yolks of eggs available in the market were not detected. Ranges of Total bacterial count (CFU/ml) on eggshell of eggs were < 10~8.2$\times$10$_3$, and isolation ratio of Escherichia coli were 4.7%. Tetracyclines were detected in 1.8% of the eggs(1 of57 brands) by CHARMII. As mentioned above, quality control and improving distribution system were required to facilitate egg consumption and improve public health by complementing labelling items and quality standards.

Full Scale Testing of the Effect of Stairwell Pressurization on Pressure Differential and Flow Velocity

  • Son, Bong-Sae;Park, Kyung-Hwan;Chang, Young-Bae
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.3
    • /
    • pp.83-89
    • /
    • 2011
  • A series of full-scale testing was conducted to examine the effect of stairwell pressurization on the pressure differential between the stairwell and the auxiliary room and between the auxiliary room and the residence. Also, flow velocity profiles at open doors were measured. The building tested was a condominium that had twenty floors above the ground and two floors underground. For pressurization of the stairs, a blower was used to supply air into the stairwell at one location underground. Thirteen different cases were tested, and test variables included the number of floors with open doors and the flow rate of the air supply. When the doors on the first floor were open, the pressure differential between the stairwell and the auxiliary room was distributed almost uniformly except for locations near the first floor. When the flow rate was in the range of 180~270 CMM and the doors of one floor were open, the flow velocity could satisfy the requirement of fire safety standards and the stairwell pressure was positive at all levels. However, the minimum pressure requirement (10 Pa) could not always be satisfied. When doors on two floors were open, the flow velocity requirement could be satisfied by increasing the flow rate, but it was found impractical to satisfy the minimum pressure requirement without causing excessive pressure differential in the area near the blower.

A Numerical Study on Smoke Behavior of Fishing Vessel Engine Room (어선 기관실의 연기 거동에 관한 수치해석 연구)

  • JANG, Ho-Sung;JI, Sang-Won
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.5
    • /
    • pp.683-690
    • /
    • 2021
  • The ventilation system of the engine room of a ship is generally installed to supply the combustion air necessary for the internal combustion engine and to remove the heat source generated in the engine room, and it must satisfy the international standard (ISO 8861) for the design conditions and calculation standards for the ventilation of the ship engine room. The response delay of the ventilation system including the fire detector is affected by the airflow formed inside the area and the location of the fire detector. In this study, to improve the initial fire detection response speed of a fire detector installed on a fishing vessel and to maintain the sensitivity of the installed detector, the smoke behavior was simulated using the air flow field inside the engine room, the amount of combustion air in the internal combustion engine, and the internal pressure of the engine room as variables. Analysis of the simulation results showed that reducing the flow rate in the air flow field and increasing the vortex by reducing the internal pressure of the engine room and installing a smoke curtain would accelerate the rise of the ceiling of the smoke component and improve the smoke detector response speed and ventilation system.

A Study on the Application of BIPV for the Spread of Zero Energy Building (제로에너지 건축물 확산을 위한 건물 일체형 태양광 적용방안 연구)

  • Park, Seung-Joon;Jeon, Hyun-Woo;Lee, Seung-Joon;Oh, Choong-Hyun
    • Journal of Digital Convergence
    • /
    • v.19 no.9
    • /
    • pp.189-199
    • /
    • 2021
  • In order to increase the self-reliance rate of new and renewable energy in order to respond to the mandatory domestic zero-energy buildings, the taller the building, the more limited the site area, and installing PV modules on the roof is not enough. Therefore, BIPV (Building integrated photovoltaic, hereinafter BIPV) is the industry receiving the most attention as a core energy source that can realize zero-energy buildings. Therefore, this study conducted a survey on the problems of the BIPV industry in a self-discussing method for experts with more than 10 years of experience of designers, builders, product manufacturers, and maintainers in order to suggest the right direction and revitalize the BIPV industry. Industrial problems of BIPV adjustment are drawn extention range of standard and certification for products, range improvement for current small condition of various kind productions, need to revise standards for capable of accomodating roof-type, color-module and louver-module, necessary of barrier in flow of foreign modules into korea through domestic certification mandatory, difficulty in obtaining BIPV information, request to prevent confusion among participants by exact guidelime about architectural application part of BIPV, and lack of the BIPV definition clearness, support policy, etc. Based on the improvements needed for the elements, giving change and competitiveness impacts aims to present and propose counter measures and direction.

A Study on Content Analysis and Types of Forest Education According to the 2015 Revised Curriculum (2015 개정 초등교육과정 내 산림교육 내용분석 및 유형화 연구)

  • Choi, Seon Hye;Ha, Si Yeon
    • Journal of Korean Society of Forest Science
    • /
    • v.110 no.4
    • /
    • pp.689-710
    • /
    • 2021
  • The purpose of this study was to analyze contents of the elementary school textbooks on 'Forest Education' based on the 2015 revised curriculum. This study is designed to determine the status of forest educationrelated content in the curriculum. Thetypesofforesteducationintextbooksweredividedintoanalysis. In addition, the standards of achievement of the curriculum were analyzed into the areas of forest education curriculum to determine the similarities between the curriculum and the achievement of forest education. This study shows that, first, the field of knowledge in forest education was included in all subjects and grades except mathematics. It noted that the curriculum includes areas of knowledge that directly convey knowledge related to forest education. This showed that the forest education knowledge area is linked to various courses. Second, the types of forest education included in the curriculum appeared differently depending on age. In the lower grades, there was the most information on the tools and sensibilities of forest education, and in the higher grades, the more knowledge and value-related areas were addressed. As the school year increases, so do forest education levels. Third, when analyzing the achievement criteria in the curriculum, the curriculum achievement criteria included key points in forest education. Thus, this study confirmed the link between the curriculum and forest education.

Correlation Analysis of the Lumbar Spine and Femur Neck BMD using Dual Energy X-ray Absorptiometry in Rehabilitated Patients (재활치료 환자에서 DXA를 이용한 요추부와 대퇴경부 골밀도 검사의 상관관계)

  • Jung, Myo-Young;Ji, Yun-Sang;Kim, Chang-Bok;Dong, Kyung-Rae;Ryu, Jae-Kwang;Choi, Ji-Won
    • Journal of Radiation Industry
    • /
    • v.12 no.4
    • /
    • pp.311-316
    • /
    • 2018
  • Average life expectancy is getting longer due to medical developments and improvements in living standards. So much so that the elderly have an increased risk of developing osteoporosis. Therefore, it is important to prevent, diagnose, and treat the senile disease at an early stage through a bone density test. Bone density is measured by dual energy X-ray absorption (DXA). In this study, while using DXA, in cases when the measurements for both the lumbar and the femur could not be taken simultaneously, the correlation between both measurements were known, and the measurement of one area was used to make a clinical inference for the value of the other. Measurements were taken using Lunar Prodigy Advance (GE) for 43 participant with clinically significant fractures. Statistical calculations were produced and analysed regarding bone density. In case of T-score, lumbar spine produced a statistical result of $-2.112{\pm}1.836$ and femur neck was $-1.716{\pm}1.565$. In case of Z-score lumbar spine produced a statistical result of $-0.151{\pm}1.513$, and femur neck $-0.026{\pm}1.283$. It is indicated that the pearson correlation coefficient of T-score between lumbar spine and femur neck is high at 0.699, and the pearson correlation coefficient of Z-score is considered relatively high at 0.503. The correlation of bone density between lumbar spine and femur neck is shown to be statistically meaningful in T-score's p-value at 0.000 and Z-score's p-value at 0.001. In conclusion, it seems to have clinical usefulness that we can infer the result of one measurement through that of the other part tested, based on the knowledge of the correlation coefficients between lumbar spine and femur neck.

Study on safety performance evaluation of stationary SOFC stack (건물용 고체산화물연료전지 스택 안전성능평가 연구)

  • Park, Tae Seong;Lee, Eun Kyung;Lee, Seung Kuk
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.1-12
    • /
    • 2018
  • The code and standards related to fuel cells were analyzed to derive the SOFC(Solid Oxide Fuel Cell) stack safety performance evaluation items and evaluation methode. Safety performance evluation of the SOFC stack was tested by quoting derived test items. The stack used in the test is an anode-supported type 2 Cell stack (Active surface area : 220cm) manufactured by MICO Inc, and SOFC stack safety performance evaluation system used for the test is self-manufactured. We conducted a leakage test, current voltage characteristic test, rated output test, and power response characteristics test. In the safety performance evaluation test, the stack showed no gas leakage, the maximum output and rated output was recorded to 65.6 W(1.41 V, 46.5 A, $422mA/cm^2$), 62.3 W(1.57 V, 40 A, $363mA/cm^2$). In the power response characteristics test verified that the output is kept stable within two seconds. At the maximum load (40 A) and the minimum load (8 A), the output was recorded 62 W and 16W in $750^{\circ}C$. This study will contribute to the universalization and to provide much safe environment of operating the solid oxide fuel cell system.

Development of optimal cross-section design methods for bored utility tunnels: case study of overseas typical cross-sections and design criteria (터널식 공동구 최적단면 설계기술 개발: 해외 표준단면 사례 및 설계기준 분석)

  • Park, Kwang-Joon;Yun, Kyoung-Yeol
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.1073-1090
    • /
    • 2018
  • Since the domestic utility tunnels were built mainly in the development project of the new city, they are all in the form of cut-and-cover box tunnel. But, in the case of overseas construction of utility tunnels for existing urban areas, the bored tunnel types are mainly adopted. It is reasonable to install bored tunnels in a downtown area because it is difficult to block the roads or install bypass roads due to heavy traffic and civil complaints. In order to activate the utility tunnels in bored type, it is necessary to secure optimized cross-sectional design technology considering the optimal supplying capacity and mutual influencing factors (Thermal Interference, electrolytic corrosion, efficiency of the maintenance, etc.) of utilities (power cables, telecommunication cables, water pipes, etc.). The optimal cross-section design method for bored utility tunnels is ultimately to derive the optimal arrangement technique for the utilities. In order to develop the design methods, firstly, the cases of tunnel cross-section (Shield TBM, Conventional Tunneling) in overseas shall be investigated to analyze the characteristics of the installation of utilities in the section and installation of auxiliary facilities, It is necessary to sort out and analyze the criteria related to the inner cross-section design (arrangement) presented in the standards and guidelines.

Engineering Characteristics of CLSM Using Bottom Ash and Eco-friendly Soil Binder (친환경 고결제와 저회를 활용한 유동성 복토재의 공학적특성)

  • Park, Giho;Kim, Taeyeon;Lee, Yongsoo;Lee, Bongjik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.5
    • /
    • pp.23-29
    • /
    • 2019
  • In general, pipe laying works are performed by constructing underground facilities such as pipes and then refilling the rest of the area with sand or soil. However, there are many problems in the compaction process such as difficulties in tampering around the underground facility and low compaction efficiency. Such problems cause deformation and damage to the underground pipes during refilling work and ultimately cause road sinks. Construction methods using CLSM are one of the typical methods to solve these issues, and recently, studies on CLSM using coal ash, which has similar engineering properties as sand, have been actively performed to protect environment and recycle resources. While many studies have been conducted to recycle fly ash in many ways, the demand for recycling bottom ash is increasing as most of the bottom ash is not recycled and reclaimed at ash disposal sites. Therefore, in order to find bottom ash applications using eco-friendly soil binders that are environmentally beneficial and conform with CLSM standards, this study investigated flow characteristics and strength change characteristics of eco-friendly soil binders, weathered granite soil, a typical site-generated soil, bottom ash, and fly ash mixed soil and evaluated the soil pollution to present CLSM application methods using bottom ash.