• 제목/요약/키워드: Area dose

검색결과 1,092건 처리시간 0.031초

심장 전기생리학 검사 시 조건 변화에 따른 환자 피폭 선량 평가 (Evaluation of Patient Exposure Dose during Cardiac Electrophysiology Study under Various Conditions)

  • 고성빈;안성민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권6호
    • /
    • pp.501-508
    • /
    • 2023
  • This study used a adult absorption dose phantom (CIRS model 701-G, USA) made of human equivalent material and the vascular imaging equipment Allura Xper FD 20 (Philips, Netherlands). Optically stimulated luminescent dosimeters (OSLD) were inserted into the anatomical positions corresponding to each organ, and the exposure dose was measured. Dose area product (DAP) and air kerma (AK) measured by the dose meter in the equipment were compared. Continuous imaging was performed at two angles for a total of 20 minutes, with a frame per seconds of 3.75 and 7.5 fps and an FOV of 42 cm, 37 cm, and 31 cm, respectively, under the conditions of fluoflavor I, II, and III, each selected for 5 repetitions. This study was found that selecting a lower fps was the most effective way to reduce patient exposure dose, and adjusting the fluoflavor was a good alternative method for reducing patient exposure dose at high fps. Therefore the method of condition change with the greatest dose reduction effect is to set the minimum FPS and can reduce patient exposure dose according to geometric conditions and fluoflavor characteristics.

공동(air cavity)의 존재 시 실험적 선량분포와 치료계획상의 선량분포 비교 (Comparison of Experimental and Radiation Therapy Planning (RTP) Dose Distributions on Air Cavity)

  • 김연래;서태석;고신관;이정우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권3호
    • /
    • pp.261-268
    • /
    • 2010
  • 고 에너지 광자선 치료 시 공동의 존재로 인한 실험적 선량분포와 치료계획상의 선량분포의 변화를 비교, 평가 하고자 하였으며, 선형가속기의 6 MV 광자선을 이용해서 폴리스틸렌 팬텀, 자체 제작한 아크릴 팬텀으로 공동을 만들고 표면에서 공동까지의 거리는 3 cm로 하고 선원-측정기간 거리는 100 cm로 고정하였고 공동의 크기는 가로 $\times$ 세로 $\times$ 높이로 정하였다. 공동의 넓이, 높이, 존재 유무, 그리고 조사면과 공동의 크기비율에 따른 깊이에 대한 선량변화를 평판형전리함과 미소전류계를 이용하여 측정하였다. 치료계획상의 선량분포는 불균질 보정을 하고 치료계획을 하여 비교하였다. 그 결과 공동의 넓이가 커짐에 따라 선량은 점차 감소하였다. 공동의 존재 시에, 공동후면 이후 깊이선량은 공동의 비존재시보다 크게 나타났다. 공동의 크기를 $5{\times}5{\times}3\;cm^3$로 고정했을 때 조사면이 $4{\times}4\;cm^2$, $5{\times}5\;cm^2$, $6{\times}6\;cm^2$일 경우에 rebuild-up이 일어났다. 그러나 조사면이 $10{\times}10\;cm^2$에서는 선량감소만이 나타났다. 또한 조사면을 $5{\times}5\;cm^2$로 고정했을 때, 공동의 넓이가 $4{\times}4\;cm^2$, $5{\times}5\;cm^2$일 경우에는 rebuild-up현상이 일어났지만, $2{\times}2\;cm^2$, $3{\times}3\;cm^2$일 경우에는 일어나지 않았다. 모든 경우에서 치료계획상의 선량분포에서 rebuild-up 현상이 나타나지 않았다. 따라서 공동이 위치한 곳에 종양이 존재할 때는 치료계획상의 선량분포에 차이가 있으므로 주의를 할 필요가 있다.

Natural radioactivity level in fly ash samples and radiological hazard at the landfill area of the coal-fired power plant complex, Vietnam

  • Loan, Truong Thi Hong;Ba, Vu Ngoc;Thien, Bui Ngoc
    • Nuclear Engineering and Technology
    • /
    • 제54권4호
    • /
    • pp.1431-1438
    • /
    • 2022
  • In this study, natural radioactivity concentrations and dosimetric values of fly ash samples were evaluated for the landfill area of the coal-fired power plant (CFPP) complex at Binh Thuan, Vietnam. The average activity concentrations of 238U, 226Ra, 232Th and 40K were 93, 77, 92 and 938 Bq kg-1, respectively. The average results for radon dose, indoor external, internal, and total effective dose equivalent (TEDE) were 5.27, 1.22, 0.16, and 6.65 mSv y-1, respectively. The average emanation fraction for fly ash were 0.028. The excess lifetime cancer risks (ELCR) were recorded as 20.30×10-3, 4.26×10-3, 0.62×10-3, and 25.61×10-3 for radon, indoor, outdoor exposures, and total ELCR, respectively. The results indicated that the cover of shielding materials above the landfill area significantly decreased the gamma radiation from the ash and slag in the ascending order: Zeolite < PVC < Soil < Concrete. Total dose of all radionuclides in the landfill site reached its peak at 19.8 years. The obtained data are useful for evaluation of radiation safety when fly ash is used for building material as well as the radiation risk and the overload of the landfill area from operation of these plants for population and workers.

Geant4 Simulation에서 Linac 광자선을 이용한 폐 선량평가 (Evaluation of Lung Dose Using Linac Photon Beam in Geant 4 Simulation)

  • 장은성;이효영
    • 한국방사선학회논문지
    • /
    • 제12권4호
    • /
    • pp.443-450
    • /
    • 2018
  • Geant4 코드는 직선 가속기의 헤드 구조를 사용하여 이전에 구현된 BEAMnrC 데이터를 기반으로 선형가속기 (VARIAN CLINAC.)를 시뮬레이션하였다, 10MV 광자 선속에서 물팬텀의 심부선량백분율과 측면선량의 측정값과 Geant4를 비교 평가하였다. 선량 계산을 인체부위에 적용하기 위해 실제 환자의 Lung 부위를 5mm 간격으로 스캔하였다. Water phantom의 조사야($5{\times}5cm^2$), SAD 100cm에서 10MV 광자를 조사하여 Geant4 선량분포를 구하였다. 이 결과는 실제 환자의 폐(lung)에 흡수되는 선량을 측정하기는 어렵다 그래서 치료계획 시스템에 의한 선량을 비교하였다. 물 팬텀에서 측정된 심부선량 곡선과 Geant4에 의해 계산된 심부선량 곡선은 build-up 영역을 제외한 대부분의 깊이에서 ${\pm}3%$ 이내로 잘 일치하였다. 그러나 5cm와 20cm 지점에서 2.95%와 2.87%로 Geant4를 사용한 선량 계산에서 다소 높은 값을 보이고 있다. 이 두 지점은 Genat4의 geometry 파일을 통해 확인할 수 있었으며, 흉추와 흉골이 위치되어 선량이 증가된 것으로 알 수 있었다. 또한, cone beam CT를 적용한 결과에서 폐(lung)의 선량분포 오차는 3% 이내로 유사한 값을 얻었다. 따라서 Geant4를 이용하여 선량을 계산할 때 DICOM 파일에 직접 선량의 contour map이 표현될 수 있다면 Geant4의 임상적 적용이 다양하게 사용될 것이다.

영상의학과 이동검사 영역의 공간선량 분포에 대한 측정 및 분석 (The Measurement and Analysis by Free Space Scatter Dose Distribution of Diagnostic Radiology Mobile Examination Area)

  • 김성규;손상혁
    • 대한디지털의료영상학회논문지
    • /
    • 제11권1호
    • /
    • pp.5-13
    • /
    • 2009
  • There are several reasons to take X-ray in case of inpatients. Some of them who cannot ambulate or have any risk if move are taken portable X-ray at their wards. Usually, in this case, many other people-patients unneeded X-ray test, family, hospital workers etc-are indirectly exposed to X-ray by scatter ray. For that reason I try to be aware of free space scatter dose accurately and make the point at issue of portable X-ray better in this study. kVp dose meter is used for efficiency management of portable X-ray equipment. Mobile X-ray equipment, ionization chamber, electrometer, solid water phantom are used for measuring of free space scatter dose. First of all the same surroundings condition is made as taken real portable X-ray, inquired amount of X-ray both chest AP and abdomen AP most frequently examined and measured scatter ray distribution of two tests individually changing distance. In the result of measuring horizontal distribution with condition of chest AP it is found that the mAs is decreased as law of distance reverse square but no showed mAs change according to direction. Vertical distribution showed the mAs slightly higher than horizontal distribution but it isnt found out statistical characteristic. In abdomen AP, compare with chest AP, free space scatter dose is as higher as five-hundred times and horizontal, vertical distribution are quite similar to chest AP in result. In portable X-ray test, in order to reduce the secondary exposure by free space scatter dose first, cut down unnecessary portable order the second, set up the specific area at individual ward for the test the third, when moving to a ward for the X-ray test prepare a portable shielding screen. The last, expose about 2m apart from patients if unable to do above three ways.

  • PDF

Stereotactic Radiosurgery를 위한 소형 조사면의 선량측정 (Treatment Planning and Dosimetry of Small Radiation Fields for Stereotactic Radiosurgery)

  • 추성실;서창옥;노준규;정상섭
    • Radiation Oncology Journal
    • /
    • 제7권1호
    • /
    • pp.101-112
    • /
    • 1989
  • The treatment planning and dosimetry of small fields for stereotactic radiosurgery with 10 MV x-ray isocentrically mounted linear accelerator is presented. Special consideration in this study was given to the variation of absorbed dose with field size, the central axis percent depth doses and the combined moving beam dose distribution. The collimator scatter correction factors of small fields $(1\times1\~3\times3cm^2)$ were measured with ion chamber at a target chamber distance of 300cm where the projected fields were larger than the polystyrene buildup caps and it was calibrated with the tissue equivalent solid state detectors of small size (TLD, PLD, ESR and semiconductors). The central axis percent depth doses for $1\timesl\;and\;3\times3cm^2$ fields could be derived with the same acuracy by interpolating between measured values for larger fields and calculated zero area data, and it was also calibrated with semiconductor detectors. The agreement between experimental and calculated data was found to be under $2\%$ within the fields. The three dimensional dose planning of stereotactic focusing irradiation on small size tumor regions was performed with dose planning computer system (Therac 2300) and was verified with film dosimetry. The more the number of strips and the wider the angle of arc rotation, the larger were the dose delivered on tumor and the less the dose to surrounding the normal tissues. The circular cone, we designed, improves the alignment, minimizes the penumbra of the beam and formats ball shape of treatment area without stellate patterns. These dosimetric techniques can provide adequate physics background for stereotactic radiosurgery with small radiation fields and 10MV x-ray beam.

  • PDF

1형과 2형 당뇨모델 흰쥐에서 Chromium Picolinate의 당내성과 인슬린 감수성에 대한 영향 (Effect of Chromium Picolinate on Glucose Tolerance and Insulin Sensitivity in the Type I and II Diabetic Rats)

  • 신현진;홍정희;고현철;신인철;강주섭;최호순;김태화;김동선;엄애선
    • Biomolecules & Therapeutics
    • /
    • 제9권4호
    • /
    • pp.277-281
    • /
    • 2001
  • Chromium is an essential nutrient and participates in glucose and lipid metabolism in human beings and animals. The present study was conducted to assess the effects of chromium picolinate (Cr-pic) on glucose tolerance and insulin sensitivity in type I and ll diabetic rats. The experimental groups were type I diabetic (streptozotocin-induced: 40 mg/kg, i.p.) and type II diabetic (Goto-Kakizaki rats) models. Each group was subdivided into control. low-dose and high-dose of Cr-pic treated groups. The Cr-pic was orally administered with Cr-pic (100 mg/kg for low dose group and 200 mg/kg for high dose group) for 4 weeks. And then we performed intraperitoneal glucose tolerance test (IPGTT) and insulin sensitivity test (ITT). The glucose tolerance test was carried out by inection of glucose (2 g/kg, i.p.). The peripheral insulin sensitivity test was con- ducted by injection of insulin (5 units/kg, s.c.) and glucose. We performed determining of blood glucose concentration at 0, 10, 30, 60, 90, and 120 min using automated glucose analyzer. The plasma insulin concentration was determined by rat insulin EIA kit. Administration of Cr-pic improved weight gain in all group s with higher significant in the low-dose group. There was no significance between the control and the Cr-pic treated groups in the area under the blood glucose curve and serum insulin concentration plots of IPGTT and peripheral ITT in type I diabetic rats. But Cr-pic treated groups showed significantly lower levels of the area under the blood glucose currie during IPGTT and ITT and the high-dose group showed less effects compared with the low-dose group in the type II diabetic rats. The plasma insulin concentration of both diabetic groups was not influenced by Cr-pic supplementation. We can conclude that chromium picolinate may improve the endogenous and exogenous insulin action and peripheral insulin sensitivity in type II diabetic rats.

  • PDF

Single-dose Intravenous Injection Toxicity of Water-soluble Danggui Pharmacopuncture (WDP) in Sprague-Dawley Rats

  • Park, Sunju;Park, Hae-Mo;Sun, Seung-Ho
    • 대한약침학회지
    • /
    • 제21권2호
    • /
    • pp.104-111
    • /
    • 2018
  • Objective:This study is to evaluate both the single-dose intravenous injection toxicity and the approximate lethal dose of Water-soluble Danggui Pharmacopuncture (WDP) in Sprague-Dawley (SD) rats. Methods: Toxicity experiments were conducted at Good Laboratory Practice (GLP) laboratory in Biotoxtech Co., according to the regulations of GLP. WDP injection of dose 0.125, 0.25, and 0.5 mL/animal were experimental groups and normal saline injection group was control group. WDP and normal saline were injected once to 6- week old 5 male and 5 female SD rats at the tail veins at approximately 2 mL/min. During 14 days after the injection, general symptoms were observed and weight were measured. After the observation period, hematological and blood biochemical examination, macroscopic autopsy, topical resistance test at the injection area were performed. Results: RThe WDP 0.5 mL/animal injection group in 4 cases of male rats and all cases of female rats showed hematuria 30 minutes after the administration. However, after 1 hour, no more abnormal general symptoms were observed. The WDP did not affect weight, hematological and blood biochemical examination, macroscopic autopsy, and topical resistance test at the injection area. Conclusion: WDP single dose intravenous injection results showed that WDP have no toxic effects and a lethal dose of WDP should be over 0.5 mL/animal in male and female rats under the study condition. So WDP may be safe.

Impact of testicular shielding in liposarcoma to scrotum by using radio-photoluminescence glass dosimeter (RPLGD): a case report

  • Oonsiri, Puntiwa;Saksornchai, Kitwadee;Suriyapee, Sivalee
    • Radiation Oncology Journal
    • /
    • 제36권3호
    • /
    • pp.248-253
    • /
    • 2018
  • Radiation protection in the scrotum to reduce the risk of genetic effect in the future is very important. This study aimed to measure the scrotal dose outside the treatment fields by using the radio-photoluminescence glass dosimeter (RPLGD). The characteristics of RPLGD model GD-302M were studied. Scattered dose to scrotum was measured in one liposarcoma case with the prescribed dose of 60 Gy. RPLGDs were placed in three different locations: one RPLGD was positioned at the posterior area which closer to the scrotum, and the other two RPLGDs were placed between the penis and the scrotum. Three RPLGDs were employed in each location. The scattered doses were measured in every fraction during the whole course of treatment. The entire number of 100 RPLGDs showed the uniformity within ±2%. The signal from RPLGD demonstrated linear proportion to the radiation dose (r = 0.999). The relative energy response correction factor was 1.05. The average scrotal dose was 4.1 ± 0.9 cGy per fraction. The results presented a wide range since there was a high uncertainty during RPLGD placement. The total scrotal dose for the whole course of treatment was 101.9 cGy (1.7% of the prescribed dose). The RPLGD model GD-302M could be used to measure scattered dose after applying the relative energy correction factor.

관전류 변화에 따른 면적선량과 영상 농도 평가 (Evaluation of Area Dose Product and Image Density according to the Variable Tube Current)

  • 윤영우;제재용
    • 한국방사선학회논문지
    • /
    • 제12권5호
    • /
    • pp.645-650
    • /
    • 2018
  • 본 연구는 면적선량에 따른 영상의 농도를 측정하여 피폭선량에 대한 정도관리 필요성을 제시하고자 하였다. 관전압을 80 kVp로 고정하고 관전류를 1, 25, 50, 80, 100 mAs로 조사한 결과 면적선량은 25 mAs에서 50 mAs로 증가하면 1.88배의 선량이 증가하고 50 mAs에서 100 mAs로 증가하면 2.05배 증가하였다. 하지만 필름으로 획득한 영상의 농도는 25 mAs에서 50 mAs로 증가하면 48% 증가하고, 50 mAs에서 100 mAs로 증가하면 29% 증가하였다. 또한 DR 영상의 농도는 25 mAs에서 50 mAs로 증가하면 12% 증가하고, 50 mAs에서 100 mAs로 증가하면 30% 증가하는 것으로 나타났다. 즉, 디지털 영상촬영 장비는 적정 촬영 조건에서 선량 증가에 따른 영상의 농도차이가 필름 영상보다는 적게 나타났다. 본 연구의 결과에서 디지털 영상 촬영 장비를 사용하는 의료기관에서는 방사선 선량에 대한 정도관리를 통하여 현재보다 촬영 부위별 피폭선량을 조금이나마 더 줄일 수 있을 것으로 판단되어진다.