• Title/Summary/Keyword: Area contact

Search Result 1,965, Processing Time 0.028 seconds

Estimation of Kinetic Parameters for Biomass Growth Using Micro-nano Bubbles Reactor (마이크로-나노버블 반응조를 이용한 미생물성장 동력학 계수의 추정에 관한 연구)

  • Han, Young-Rip;Jung, Byung-Gil;Jung, Yoo-Jin;Cho, Do-Hyun;Sung, Nak-Chang
    • Journal of Environmental Science International
    • /
    • v.19 no.5
    • /
    • pp.647-653
    • /
    • 2010
  • The objectives of this research are to evaluate and compare the oxygen transfer coefficients($K_{La}$) in both a general bubbles reactor and a micro-nano bubbles reactor for effective operation in sewage treatment plants, and to understand the effect on microbial kinetic parameters of biomass growth for optimal biological treatment in sewage treatment plants when the micro-nano bubbles reactor is applied. Oxygen transfer coefficients($K_{La}$) of tap water and effluent of primary clarifier were determined. The oxygen transfer coefficients of the tap water for the general bubbles reactor and micro-nano bubbles reactor were found to be 0.28 $hr^{-1}$ and 2.50 $hr^{-1}$, respectively. The oxygen transfer coefficients of the effluent of the primary clarifier for the general bubbles reactor and micro-nano bubbles reactor were found be to 0.15 $hr^{-1}$ and 0.91 $hr^{-1}$, respectively. In order to figure out kinetic parameters of biomass growth for the general bubbles reactor and micro-nano bubbles reactor, oxygen uptake rates(OURs) in the saturated effluent of the primary clarifier were measured with the general bubbles reactor and micro-nano bubbles reactor. The OURs of in the saturated effluent of the primary clarifier with the general bubbles reactor and micro-nano bubbles reactor were 0.0294 mg $O_2/L{\cdot}hr$ and 0.0465 mg $O_2/L{\cdot}hr$, respectively. The higher micro-nano bubbles reactor's oxygen transfer coefficient increases the OURs. In addition, the maximum readily biodegradable substrate utilization rates($K_{ms}$) for the general bubbles reactor and micro-nano bubbles reactor were 3.41 mg COD utilized/mg active VSS day and 7.07 mg COD utilized/mg active VSS day, respectively. The maximum specific biomass growth rates for heterotrophic biomass(${\mu}_{max}$) were calculated by both values of yield for heterotrophic biomass($Y_H$) and the maximum readily biodegradable substrate utilization rates($K_{ms}$). The values of ${\mu}_{max}$ for the general bubbles reactor and micro-nano bubbles reactor were 1.62 $day^{-1}$ and 3.36 $day^{-1}$, respectively. The reported results show that the micro-nano bubbles reactor increased air-liquid contact area. This method could remove dissolved organic matters and nutrients efficiently and effectively.

Characteristics of LSC coated Metallic Interconnect for Solid Oxide Fuel Cell (LSC가 코팅된 고체산화물 연료전지용 금속연결재의 특성 연구)

  • Pyo, Seong-Soo;Lee, Seung-Bok;Lim, Tak-Hyoung;Park, Seok-Joo;Song, Rak-Hyun;Shin, Dong-Ryul
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.172-177
    • /
    • 2010
  • This study reports the high-temperature oxidation kinetics, ASR(area specific resistance), and interfacial microstructure of metallic interconnects coated with conductive oxides in oxidation atmosphere at $800^{\circ}C$, The conductive material LSC($La_{0.8}Sr_{0.2}CoO_3$, prepared by Solid State Reaction) was coated on the Crofer22APU. The contact behavior of coating layer/metal substrate was increased by sandblast. The electrical conductivity of the LSC coated Crpfer22APU was measured by a DC two probe four wire method for 4000hr, in air at $800^{\circ}C$. Microstructure and composition of the coated layer interface were investigated by SEM/EDS. These results show that a coated LSC layer prevents the formation and growth of oxide scale such as $Cr_2O_3$ and enhances the long-term stability and electrical performance of metallic interconnects for SOFCs.

Comparative Study on the Pulse Wave Variables and Sasang Constitution in Diabetes Mellitus Patients and Healthy Subjects (당뇨병 환자와 건강인의 맥상과 사상체질에 관한 연구)

  • Park, Su-Jeong;Kim, Kyung-Yo;Lee, Si-Woo;Kwon, Young-Mi;Kil, Eun-Young;Joo, Jong-Cheon
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.21 no.6
    • /
    • pp.1601-1610
    • /
    • 2007
  • The purpose of this study was to determine whether a pulse analyzer was useful 1) to characterize the variables of pulse wave of diabetes mellitus group, compared with those of healthy subjects, and 2) to determine Sasang Constitution in diabetes mellitus group and healthy subjects. 1. The sum of pulse pressure (energy) and the ratio of systolic period area (As%), called pulse pressure-related variables, were higher in diabetes mellitus group than healthy group, while the height of dicrotic wave (h5) and the ratio of height of dicrotic wave to height of percussion wave (h5/h1), correlated with arterial compliance, were lower in diabetes mellitus group than healthy group. 2. Taeumin of diabetes mellitus group showed higher pressure-related variables than that of healthy group. 3. Soumin of diabetes mellitus group had shorter the time to dicrotic wave (t5) than that of healthy group. 4. Soyangin of diabetes mellitus group showed higher heart rates and lower values in pulse wave time-related variables, including time to dicrotic wave(t5), time to incisura (t4), total time minus time to incisura (t-t4), total time (t), width of percussion wave (w), and the ratio of width of percussion wave to total time (w/t), than that of healthy group. 5. Contact pressure (CP), sum of pulse pressure (energy), height of pre-incisura (h2), height of incisura (h4), width of percussion wave (w), time to incisura (t4), time to percussion wave (t1), variance of total time (Vt), variance of height of percussion wave(Vp) and the ratio of height of incisura to height of percussion wave (h4/h1) were used to develop the rules of Sasang Constitution Classification with about seventy five percents accuracy. These suggested that the pulse analyzer was useful to evaluate the risk degree of diabetes mellitus and to determine Sasang Constitution among either diabetes mellitus group or healthy group.

Photocatalytic Degradation of Fungicide Chlorothalonil by Mesoporous Titanium Oxo-Phosphate (Mesoporous Titanium Oxo-Phosphate에 의한 살균제 Chlorothalonil의 광분해)

  • Choi, Choong-Lyeal;Kim, Byung-Ha;Lee, Byung-Mook;Choi, Jyung;Rhee, In-Koo;Kim, Jang-Eok
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.4
    • /
    • pp.284-289
    • /
    • 2003
  • Titanium mesoporous materials have received increasing attention as a new photocatalyst in the field for photocatalytic degradation of organic compounds. The photocatalytic degradation of chlorothalonil by mesoporous titanium oxo-phoswhate (Ti-MCM) was investigated in aqueous suspension for comparison with $TiO_2$, (Degussa, P25) using as an effective photocatalyst of organic pollutants. Mesoporous form of titanium Phosphate has been prepared by reaction of sulfuric acid and titanium isopropoxide in the presence or n-hexadecyltrimethylammonium bromide. The XRD patterns of Ti-MCM are hexagonal phases with d-spacings of 4.1 nm. Its adsorption isotherm for chlorothalonil reached at reaction equilibrium within 60 min under dark condition with 28% degradation efficiency. The degradation ratio of chlorothalonil after 9 hours under the UV radiation condition (254 nm) exhibited 100% by Ti-MCM and 88% by $TiO_2$. However, these degradation kinetics in static state showed a slow tendency compared to that of stirred state because of a low contact between titanium matrices and chlorothalonil. Also, degradation efficiency of chlorothalonil was increased with decreasing initial concentration and with increasing pH of solution. As results of this study, it was clear that mesoporous titanium oxo-phosphate with high surface area and crystallinity could be used to photo- catalytic degradation of various organic pollutants.

The Persistent Paresthesia Care on Left Lingual & Buccal Shelf Regions after the Lingual & Long Buccal Nerve Block Anesthesia -A Case Report- (설신경과 장협신경 전달마취 시행 후 발생된 설부와 협선반부의 장기간 이상감각증 관리 -증례보고-)

  • Kim, Ha-Rang;Yoo, Jae-Ha;Choi, Byung-Ho;Mo, Dong-Yub;Lee, Chun-Ui;Kim, Jong-Bae
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.9 no.2
    • /
    • pp.108-115
    • /
    • 2009
  • Trauma to any nerve may lead to persistent paresthesia. Trauma to the nerve sheath can be produced by the needle. The patient frequently reports the sensation of an electric shock throughout the distribution of the nerve involved. It is difficult for the type of needle used in dental practice to actually sever a nerve trunk or even its fibers. Trauma to the nerve produced by contact with the needle is all that is needed to produce paresthesia. Hemorrhage into or around the neural sheath is another cause. Bleeding increases pressure on the nerve, leading to paresthesia. Injection of local anesthetic solutions contaminated by alcohol or sterilizing solution near a nerve produces irritation; the resulting edema increases pressure in the region of the nerve, leading to paresthesia. Persistent paresthesia can lead to injury to adjacent tissues. Biting or thermal or chemical insult can occur without a patient's awareness, until the process has progressed to a serious degree. Most paresthesias resolve in approximately 8 weeks without treatment. In most situations paresthesia is only minimal, with the patient retaining most sensory function to the affected area. In these cases there is only a very slight possibility of self injury. But, the patient complaints the discomfort symptoms of paresthesia, such as causalgia, neuralgiaform pain and anesthesia dolorosa. Most paresthesias involve the lingual nerve, with the inferior alveolar nerve a close second. This is the report of a case, that had the persistent paresthesia care on left lingual & buccal shelf regions after the lingual and long buccal nerve block anesthesia.

  • PDF

Comparing Malaysian Youths and Adults'toward Hallyu Consciousness (말레이시아 청소년과 성인들의 한류 의식 비교)

  • Cho, Kum-Ju;Jang, Won-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.9
    • /
    • pp.92-101
    • /
    • 2013
  • Hallyu in Malaysia is considered to be in the growth stage as in countries such as Philippine, Myanmar, Hungary, and Uzbekistan. In the growth stage, Hallyu becomes increasingly popular and familiar to the general public and the sales of Hallyu-related products starts to increase. The purpose of this research is to compare how Hallyu is perceived among Malaysian youths and adults. Analysis is carried out using FGD. The two groups are asked about what they think of Korea and the success of Hallyu, how much interest they have in foreign cultures in general, and how they come into contact with them. Based on these results, problems currently facing Hallyu and possible solutions are examined. The analysis shows that the interest in Hallyu among Malaysians varies according to age and gender. Both male and female participants in their 20's have shown a much greater interest in Hallyu than the participants over 30's. But Malaysians are known to be relatively open-minded about accepting foreign cultures, and this is reflected in the current study. They view the popularity of Korean drama, movies, and music as a trend, rather than being intolerant of them. There is no concern for negativity toward Hallyu in Malaysia, but it is likely that Hallyu may be replaced by another foreign culture unless its influence is constantly maintained in the area. Therefore, it is essential to develop measures and models to not only retain, but strengthen Hallyu's influence.

Generation and Current Treatment Status of Sewage at the Rural Village in Chungnam Province (충남지역 마을하수의 발생 및 처리현황)

  • Kang, Bang-Hun;Kim, Jin-Ho;Choi, Chul-Mann
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.1
    • /
    • pp.44-49
    • /
    • 2008
  • The purpose of this study is to investigate the current status, including the maintenance problems and removal efficiency, of small sewage treatment facilities in Chung-nam province(Asan, Buyeo, and Gongju city). Our results showed that inflow water quality of Asan city was 19.1 mg/L of BOD, 29.0 mg/L of COD, 13.4 mg/L of T-N and 1.5 mg/L of T-P, respectively, which was much higher than any other site. Among the factors known to be an important index of water quality, the SS and BOD removal efficiency was about 70% and 50% respectively. However, the nitrogen removal efficiency was less than 10%. The total removal efficiency of pollutant was 71.1% of SS, 52.6% of BOD, 46.2% of COD, 9.2% of T-P and 4.6% of T-N respectively. Therefore nitrogen removal processes are required to prevent serious eutrophication of small river. Removal efficiency for BOD and SS of high-efficient sewage treatment facilities (STFs) and contact oxidation process was much higher than another process. Performance of these sewage treatment facilities(STFs) is not optimal due to ineffective planning for the inflow water quality. To improve these facilities, it is proposed that a technical expert analysis of water quality at these facilities is periodically required.

A Study on the Stability of the Ca-Bentonite Colloids Using a Dynamic Light Scattering Method (동적광산란 방법을 이용한 칼슘벤토나이트 콜로이드의 안정성에 대한 연구)

  • Baik Min-Hoon;Park Jong-Hoon;Cho Won-Jin
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.3
    • /
    • pp.12-19
    • /
    • 2006
  • In this study, the stability of Ca-bentonite colloids from Gyeongju area was studied by investigating the changes in the size of the bentonite colloids using a dynamic light scattering method depending on the geochemical conditions such as pH and ionic strength. Kinetic and equilibrium coagulation behavior of the bentonite colloids was investigated by changing the pH and ionic strength of the bentonite suspensions. The results showed that the stability of the bentonite colloids strongly depended upon contact time, pH, and ionic strength. It was also shown that the bentonite colloids were unstable at higher ionic strength greater than 0.01 M $NaClO_4$ at whole pH values considered. In addition, the stability ratio Wand the critical coagulation concentration (CCC) were also calculated using the data from the kinetic coagulation experiments. The stability ratio W was decreased as the ionic strength increased and varied with pH depending on the ionic strength. The CCC of the Ca-bentonite colloids was about 0.05 M $NaClO_4$ around pH 7.

Clinical and Statistical Analysis with Age in Cases of Pediatric Burn Patients (소아 화상 환자 2,795례에 대한 연령별 임상 통계학적 분석)

  • Cho, Ki-Hyun;Jang, Young-Chul;Lee, Jong-Wook;Koh, Jang-Hyu;Seo, Dong-Kook;Choi, Jai-Ku
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.445-450
    • /
    • 2011
  • Purpose: The objective of this study is to analyze the epidemiological characteristics of pediatric burn patients and to determine the targets for a pediatric burn prevention program. Methods: A retrospective review of all medical records of acute pediatric burn patients (age < 15 years old) admitted to our hospital between January 2005 and December 2009 was performed. Results: 1472 males and 1323 females were investigated, with a male to female ratio of 1.11 : 1. The greatest number of burn patients were those with an age of 1~2 years (1,463, 52.3%). Scalding burn was the most common cause of injury, which accounted for 2183 (78.1%) patients, followed by contact burns (10.5%), flame burn (4.9%), steam burn (3.6%). Especially steam burn was the second cause of injury in the age under 1 year, while flame burn was the second cause of injury in the age over 7 years. During recent 5 years, incidence of flame burn, steam burn, electrical burn gradually decreased. Variation of seasonal incidence is minimal and most of the patients (2,716 cases, 97.2%) had burns less than 20% TBSA (Total body surface area). The median hospital stay was 18.79 days, and the rate of operation was 28.6% with a high rate in electrical burn (76.2%), flame burn (50.0%), steam burn (46.1%). 6 patients died in this series, which yielded a mortality rate of 0.2%. Conclusion: Prevention efforts should reflect recent study results. Focused prevention program and campaign to make people aware of risk factors and their avoidance is required to reduce the number of burn accidents in children.

Improvement of Electron Emission Characteristics and Emission Stability from Metal-coated Carbon Nanotubes (금속 코팅된 탄소나노튜브의 전계 방출 특성 및 신뢰성 향상)

  • Uh, H.S.;Park, S.;Kim, B.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.6
    • /
    • pp.436-441
    • /
    • 2011
  • Metal coating with several nanometer thickness was applied on the carbon nanotubes (CNTs) in order to improve electron emission characteristics and emission reliability for the potential applications in the area of various electron sources and displays. CNTs were grown on the 2-nm thick Invar (52% Fe, 42% Ni, 6% Co alloy)-catalized Si substrate by using plasma-enhanced chemical vapor deposition at $450^{\circ}C$. In order to reduce the spatial density of densely packed CNTs, as-grown CNTs were partly etched back by $N_2$ plasma and subsequently coated with 5~150 nm thick Ti by a sputtering method. 5 nm thick Ti-coated CNTs produced four times higher emission current density at the electric field of 6 V/${\mu}m$ and much lower emission current fluctuation, compared with the as-grown CNTs. These improved emission properties are mainly due to not only the work function of Ti (4.3 eV) lower than that of pristine CNTs (5 eV), but also lower contact resistance and better adhesion between CNT emitters and substrate accomplished by Ti coating.